986 resultados para Cr : YAG


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Infrared (1.2-1.6 mum) luminescence in a yttrium aluminium garnet (YAG) crystal, co-doped with Yb (10 at.%) and Cr (0.05 at.%) ions, was investigated under CW laser diode pumping (lambda = 940 nm). The Cr4+ emission band was observed with its peak at 1.35 mum and measured to be about 6% with respect to Yb3+ IR luminescence (lambda = 1.03 mum). Analysis of the crystal absorption and luminescence spectra allows one to conclude that Yb3+-Cr4+ energy transfer is a mechanism responsible for the B-3(2)(T-3(2))-B-3(1)((3)A(2)) emission of Cr4+ ions. This crystal is promising as an efficient source of the near infrared emission. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

介绍了近几年迅速发展的一种新型激光介质——透明Nd:YAG多晶陶瓷的发展状况,对比分析了多晶陶瓷与单晶的光谱特性、激光特性和连续实验研究情况。并对钛宝石激光器调谐至808nm,端面抽运Nd:YAG陶瓷被动调Q全固态激光器的脉冲运转进行了较为详细的理论分析和实验研究。采用初始透射率为90%的Cr^4+:YAG可饱和吸收晶体,被动调Q的阈值功率为119mW,当端面抽运功率为465mW时,获得波长为1064nm,脉宽为16ns,重复频率为18.18kHz,单脉冲能量为3.4μJ,平均输出功率为61mW的稳定调Q

Relevância:

40.00% 40.00%

Publicador:

Resumo:

报道了激光二极管(LD)抽运的Nd:YLF激光器,采用平凹腔结构,分别用两片Cr^4+:YAG可饱和吸收晶体,实现了被动调Q,输出激光波长为1053nm。采用厚度为0.5mm小信号透过率为90%的Cr^4+ YAG,在泵浦功率最大为17W时,输出脉冲宽度为60.6ns,平均功率为1.5W,重复频率为9.5kHz,单脉冲能量为157.9mJ;采用厚度为0.55mm小信号透过率为95%的Cr^4+ YAG,在泵浦功率最大为17W时,输出脉冲宽度为68.6ns,平均功率为1.35W,重复频率为14kHz,单脉冲

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The fluorescence emission spectra of Cr:Yb:YAG crystal are measured and the effective stimulated emission cross section of the crystal are obtained from -80 degrees C to +80 degrees C. A linear temperature dependence between -80 degrees C and +80 degrees C is reported for the 1.03 mu m peak stimulated emission cross section of Cr:Yb:YAG crystal. (c) 2004 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The fluorescence emission spectra of Cr:Nd:YAG crystal are measured and the effective stimulated emission cross-section of the crystal is obtained from -80 to +80 degrees C. A linear temperature dependence between -80 and +80 degrees C is reported for the 1.064-mu m peak stimulated emission cross-section of Cr:Nd:YAG crystal. (C) 2005 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

用光纤耦合激光二极管抽运Cr,Yb:YAG晶体获得了1.03 μm的自调Q激光输出,输出的调Q脉冲非常稳定,抽运阈值功率为680 mW,脉冲宽度为3.3 ns,获得的平均功率为156 mW,斜率效率为18.5%。随着抽运功率的增大,重复频率成线性增长,而脉宽略有减少,单脉冲能量和峰值功率都始终呈增大趋势。光束质量因子M2为1.17。

Relevância:

40.00% 40.00%

Publicador:

Resumo:

研究了室温下Yb:YAG的上转换荧光光谱,此荧光归因于Yb^3+离子的“合作”发光和Yb抖离子到稀土杂质离子的能量转移。测试了Yb;YAG晶体的X射线荧光,发光峰对应于电荷迁移态到Yb^3+离子的基态、激光态间的跃迁。研究了Cr,Yb:YAG晶体的荧光光谱。讨论了Cr^4+激光输出的可能性。

Relevância:

40.00% 40.00%

Publicador:

Resumo:

采用传统的X型像散腔,利用一块精心设计的半导体可饱和吸收镜(SESAM)做启动元件,实现了自启动的Kerr锁模Cr4+∶YAG激光器.输出脉冲的最窄脉宽小于80 fs,脉冲重复频率为120 MHz,脉冲峰值功率可以达到100 W以上.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to conduct an in vitro evaluation, by scanning electron microscopy (SEM), of the adhesion of blood components on root surfaces irradiated with Er,Cr:YSGG (2.78 mu m) or Er:YAG (2.94 mu m) laser, and of the irradiation effects on root surface morphology. Sixty samples of human teeth were previously scaled with manual instruments and divided into three groups of 20 samples each: G1 (control group) - no treatment; G2 - Er,Cr:YSGG laser irradiation; G3 - Er:YAG laser irradiation. After performing these treatments, blood tissue was applied to 10 samples of each group, whereas 10 samples received no blood tissue application. After performing the laboratory treatments, the samples were observed under SEM, and the resulting photomicrographs were classified according to a blood component adhesion scoring system and root morphology. The results were analyzed statistically (Kruskall-Wallis and Mann Whitney tests, alpha = 5%). The root surfaces irradiated with Er:YAG and Er,Cr:YSGG lasers presented greater roughness than those in the control group. Regarding blood component adhesion, the results showed a lower degree of adhesion in G2 than in G1 and G3 (G1 x G2: p = 0.002; G3 x G2: p = 0.017). The Er:YAG and Er,Cr:YSGG laser treatments caused more extensive root surface changes. The Er:YAG laser treatment promoted a greater degree of blood component adhesion to root surfaces, compared to the Er,Cr:YSGG treatment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The laser has been widely used in many specialties of dentistry and several wavelengths have been investigated as a substitute for high-speed handpiece. The purpose of this paper is to review the literature about the use of Er:YAG and Er,Cr:YSGG lasers in cavity preparation for dental tissues. Despite the differences in wavelength, pulse duration and energy, the morphological characteristics of the irradiated dentin surface with these lasers are comparable, as well as its effects as methods of dental caries prevention. Thus, Er:YAG and Er,Cr:YSGG lasers prepared cavities with similar effects on the dental tissue, however, further investigations about ideal irradiation conditions are needed for both lasers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dentine hypersensitivity (DH) is a painful condition and is a clinical challenge due to the different treatment strategies available. High-intensity lasers have been studied as a possible option. The aim of this randomized, controlled, double-blind clinical study was to evaluate the effects of Er:YAG and Er,Cr:YSGG lasers on DH. The study group comprised 28 subjects who met the inclusion criteria. A visual analogue scale was used to quantify sensitivity before treatment as baseline, immediately before and immediately after treatment, and 1 week and 1 month after treatment. Teeth were assigned to four groups: group 1 control (no treatment), group 2 Er:YAG laser treatment (2 Hz/32.4 mJ/5.9 J/cm(2)), group 3 Er,Cr:YSGG laser treatment (0.25 W/4.4 J/cm(2)), and group 4 Er,Cr:YSGG laser treatment (0.50 W/ 8.9 J/cm(2)). Data were collected and submitted to statistical analysis for both evaporative (air) and mechanical (probe) stimulation. For both the air and probe stimulation no differences were observed between the pretreatment sensitivities. With the evaporative stimulus, the pain level immediately after treatment was reduced; however, after this the values remained stable. Irradiation with the Er:YAG laser was associated with the lowest level of pain. With the mechanical stimulus, group 4 showed the most pronounced decrease in pain immediately after treatment; however, by the end of the study, pain levels had increased. Groups 1, 2 and 3 showed a reduction in pain that was significantly different from that in group 4 after the 4 weeks of clinical follow up. Based on the results and within the limits of this study, it can be concluded that none of the laser treatments studied was capable of completely eliminating pain, but the Er:YAG and Er,Cr:YSGG lasers are suitable for the treatment of DH.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

实验研究了激光二极管阵列(LDA)侧向抽运国产Nd∶YAG陶瓷棒的准连续及被动调Q激光输出特性。该陶瓷激光器采用LDA侧面紧密环绕均匀排布的抽运结构,陶瓷棒抽运区域长度为20 mm,其总尺寸为3 mm×35 mm,掺杂原子数分数为~1%。在千赫兹准连续运转条件下,当平-平谐振腔的输出耦合镜透过率为47.3%时,获得最大平均功率23 W的1064 nm激光输出,光束发散角为4.5 mrad,斜率效率达12%。在谐振腔内插入Cr4+∶YAG晶体作为被动调Q开关,成功地实现了陶瓷激光器千赫兹重复频率调Q激光脉冲输出,当Cr4+∶YAG晶体初始透过率为60%时,输出激光脉冲宽度(半峰全宽)可窄至14.5 ns,调Q动静比约为40%。

Relevância:

30.00% 30.00%

Publicador:

Resumo:

By use of a laser diode as a pump source, a self-Q-switched laser from a Cr,Nd:YAG crystal is demonstrated. The output Q-switched traces are very stable, the threshold pump power is 3.5 W, the pulse duration is 50 ns, and the slope efficiency is as high as 20%. In addition, the pulse width remains constant while the pulse repetition rate Varies with pump power. (C) 2000 Optical Society of America OCIS codes: 140.0140, 140.2020, 140.3380, 140.3480, 140.3540, 140.3580.