979 resultados para Coupled response measurements
Resumo:
Detection of a circumferential crack in a hollow section beam is investigated using coupled response measurements. The crack section is represented by a local flexibility matrix connecting two undamaged beam segments. This matrix defines the relationship between the displacements and forces across the crack section and is derived by applying fundamental fracture mechanics theory. The suitability of the mode coupling methodology is first demonstrated analytically. Laboratory test results are then presented for circular hollow section beams with artificially generated cracks of varying severity. It is shown that this method has the potential as a damage detection tool for mechanical structures. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
Due to the existence of global modes and local modes of the neighbouring members, damage detection on a structure is more challenging than damage on isolated beams. Detection of an artificial circumferential crack on a joint in a frame-like welded structure is studied in this paper using coupled response measurements. Similarity to real engineering structures is maintained in the fabrication of the test frame. Both the chords and the branch members have hollow sections and the branch members have smaller sizes. The crack is created by a hacksaw on a joint where a branch meets the chord. The methodology is first demonstrated on a single hollow section beam. The test results are then presented for the damaged and undamaged frame. The existence of the damage is clearly observable from the experimental results. It is suggested that this approach offers the-potential to detect damage in welded structures such as cranes, mining equipment, steel-frame bridges, naval and offshore structures. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
A few years ago, some of the authors of the paper demonstrated the resonance of optical antennas in the visible frequencies. The results of that paper were obtained using experimental techniques that were primarily developed for the measurement of antenna-coupled detectors in the infrared. In the present paper, we show the results of spatial-response mapping obtained by using a dedicated measurement station for the characterization of optical antennas in the visible. At the same time, the bottleneck in the spatial responsivity calculation represented by the beam characterization has been approached from a different perspective. The proposed technique uses a collection of knife edge measurements in order to avoid the use of any model of the laser beam irradiance. By taking all this into account we present the spatial responsivity of optical antennas measured with high spatial resolution in the visible.
Resumo:
In this work, a method of computing PD stabilising gains for rotating systems is presented based on the D-decomposition technique, which requires the sole knowledge of frequency response functions. By applying this method to a rotating system with electromagnetic actuators, it is demonstrated that the stability boundary locus in the plane of feedback gains can be easily plotted, and the most suitable gains can be found to minimise the resonant peak of the system. Experimental results for a Laval rotor show the feasibility of not only controlling lateral shaft vibration and assuring stability, but also helps in predicting the final vibration level achieved by the closed-loop system. These results are obtained based solely on the input-output response information of the system as a whole.
Resumo:
The current design life of nuclear power plant (NPP) could potentially be extended to 80 years. During this extended plant life, all safety and operationally relevant Instrumentation & Control (I&C) systems are required to meet their designed performance requirements to ensure safe and reliable operation of the NPP, both during normal operation and subsequent to design base events. This in turn requires an adequate and documented qualification and aging management program. It is known that electrical insulation of I&C cables used in safety related circuits can degrade during their life, due to the aging effect of environmental stresses, such as temperature, radiation, vibration, etc., particularly if located in the containment area of the NPP. Thus several condition monitoring techniques are required to assess the state of the insulation. Such techniques can be used to establish a residual lifetime, based on the relationship between condition indicators and ageing stresses, hence, to support a preventive and effective maintenance program. The object of this thesis is to investigate potential electrical aging indicators (diagnostic markers) testing various I&C cable insulations subjected to an accelerated multi-stress (thermal and radiation) aging.
Resumo:
Detection of a fatigue crack in a welded frame structure is studied in this paper using coupled response measurements. Similarity to real engineering structures is maintained in the fabrication of the test frame with hollow section chords and branch members. The fatigue crack was created by a special reciprocating mechanism that generates cyclic stress on a beam member of the structure. The methodology of coupled response measurements is first demonstrated on a single hollow section beam by analytical simulation and experimental validation. The issues of using this approach for fatigue crack detection in real structures are then examined. Finally, the experimental results of the frame under different scenarioes are presented. The existence of the crack is clearly observable from the FRF plots. It is suggested that this approach offers the potential to detect cracks in welded frame structures and is a useful tool for routine maintenance work and health assessment.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
With the main focus on safety, design of structures for vibration serviceability is often overlooked or mismanaged, resulting in some high profile structures failing publicly to perform adequately under human dynamic loading due to walking, running or jumping. A standard tool to inform better design, prove fitness for purpose before entering service and design retrofits is modal testing, a procedure that typically involves acceleration measurements using an array of wired sensors and force generation using a mechanical shaker. A critical but often overlooked aspect is using input (force) to output (response) relationships to enable estimation of modal mass, which is a key parameter directly controlling vibration levels in service.
This paper describes the use of wireless inertial measurement units (IMUs), designed for biomechanics motion capture applications, for the modal testing of a 109 m footbridge. IMUs were first used for an output-only vibration survey to identify mode frequencies, shapes and damping ratios, then for simultaneous measurement of body accelerations of a human subject jumping to excite specific vibrations modes and build up bridge deck accelerations at the jumping location. Using the mode shapes and the vertical acceleration data from a suitable body landmark scaled by body mass, thus providing jumping force data, it was possible to create frequency response functions and estimate modal masses.
The modal mass estimates for this bridge were checked against estimates obtained using an instrumented hammer and known mass distributions, showing consistency among the experimental estimates. Finally, the method was used in an applied research application on a short span footbridge where the benefits of logistical and operational simplicity afforded by the highly portable and easy to use IMUs proved extremely useful for an efficient evaluation of vibration serviceability, including estimation of modal masses.
Resumo:
The full-scale base-isolated structure studied in this dissertation is the only base-isolated building in South Island of New Zealand. It sustained hundreds of earthquake ground motions from September 2010 and well into 2012. Several large earthquake responses were recorded in December 2011 by NEES@UCLA and by GeoNet recording station nearby Christchurch Women's Hospital. The primary focus of this dissertation is to advance the state-of-the art of the methods to evaluate performance of seismic-isolated structures and the effects of soil-structure interaction by developing new data processing methodologies to overcome current limitations and by implementing advanced numerical modeling in OpenSees for direct analysis of soil-structure interaction.
This dissertation presents a novel method for recovering force-displacement relations within the isolators of building structures with unknown nonlinearities from sparse seismic-response measurements of floor accelerations. The method requires only direct matrix calculations (factorizations and multiplications); no iterative trial-and-error methods are required. The method requires a mass matrix, or at least an estimate of the floor masses. A stiffness matrix may be used, but is not necessary. Essentially, the method operates on a matrix of incomplete measurements of floor accelerations. In the special case of complete floor measurements of systems with linear dynamics, real modes, and equal floor masses, the principal components of this matrix are the modal responses. In the more general case of partial measurements and nonlinear dynamics, the method extracts a number of linearly-dependent components from Hankel matrices of measured horizontal response accelerations, assembles these components row-wise and extracts principal components from the singular value decomposition of this large matrix of linearly-dependent components. These principal components are then interpolated between floors in a way that minimizes the curvature energy of the interpolation. This interpolation step can make use of a reduced-order stiffness matrix, a backward difference matrix or a central difference matrix. The measured and interpolated floor acceleration components at all floors are then assembled and multiplied by a mass matrix. The recovered in-service force-displacement relations are then incorporated into the OpenSees soil structure interaction model.
Numerical simulations of soil-structure interaction involving non-uniform soil behavior are conducted following the development of the complete soil-structure interaction model of Christchurch Women's Hospital in OpenSees. In these 2D OpenSees models, the superstructure is modeled as two-dimensional frames in short span and long span respectively. The lead rubber bearings are modeled as elastomeric bearing (Bouc Wen) elements. The soil underlying the concrete raft foundation is modeled with linear elastic plane strain quadrilateral element. The non-uniformity of the soil profile is incorporated by extraction and interpolation of shear wave velocity profile from the Canterbury Geotechnical Database. The validity of the complete two-dimensional soil-structure interaction OpenSees model for the hospital is checked by comparing the results of peak floor responses and force-displacement relations within the isolation system achieved from OpenSees simulations to the recorded measurements. General explanations and implications, supported by displacement drifts, floor acceleration and displacement responses, force-displacement relations are described to address the effects of soil-structure interaction.
Resumo:
The climate over the Arctic has undergone changes in recent decades. In order to evaluate the coupled response of the Arctic system to external and internal forcing, our study focuses on the estimation of regional climate variability and its dependence on large-scale atmospheric and regional ocean circulations. A global ocean–sea ice model with regionally high horizontal resolution is coupled to an atmospheric regional model and global terrestrial hydrology model. This way of coupling divides the global ocean model setup into two different domains: one coupled, where the ocean and the atmosphere are interacting, and one uncoupled, where the ocean model is driven by prescribed atmospheric forcing and runs in a so-called stand-alone mode. Therefore, selecting a specific area for the regional atmosphere implies that the ocean–atmosphere system can develop ‘freely’ in that area, whereas for the rest of the global ocean, the circulation is driven by prescribed atmospheric forcing without any feedbacks. Five different coupled setups are chosen for ensemble simulations. The choice of the coupled domains was done to estimate the influences of the Subtropical Atlantic, Eurasian and North Pacific regions on northern North Atlantic and Arctic climate. Our simulations show that the regional coupled ocean–atmosphere model is sensitive to the choice of the modelled area. The different model configurations reproduce differently both the mean climate and its variability. Only two out of five model setups were able to reproduce the Arctic climate as observed under recent climate conditions (ERA-40 Reanalysis). Evidence is found that the main source of uncertainty for Arctic climate variability and its predictability is the North Pacific. The prescription of North Pacific conditions in the regional model leads to significant correlation with observations, even if the whole North Atlantic is within the coupled model domain. However, the inclusion of the North Pacific area into the coupled system drastically changes the Arctic climate variability to a point where the Arctic Oscillation becomes an ‘internal mode’ of variability and correlations of year-to-year variability with observational data vanish. In line with previous studies, our simulations provide evidence that Arctic sea ice export is mainly due to ‘internal variability’ within the Arctic region. We conclude that the choice of model domains should be based on physical knowledge of the atmospheric and oceanic processes and not on ‘geographic’ reasons. This is particularly the case for areas like the Arctic, which has very complex feedbacks between components of the regional climate system.
Resumo:
El presente Trabajo Fin de Máster pretende llevar a cabo el análisis del comportamiento vibratorio de resonadores de membrana, consistentes en un panel delgado y ligero montado a cierta distancia de un elemento constructivo rígido y pesado. Este tipo de sistemas resonantes son empleados habitualmente como absorbentes de media-baja frecuencia en aplicaciones de acondicionamiento acústico de salas. El análisis hará especial hincapié en la influencia del acoplamiento mecánico-acústico entre la placa vibrante (estructura) y el colchón de aire (fluido) encerrado entre la misma y la pared rígida. En primer lugar, realizaremos el análisis modal experimental del resonador objeto de ensayo a partir de las mediciones de su respuesta vibratoria, con el fin de caracterizar su comportamiento en base a sus primeros modos propios acoplados de flexión. El análisis de las señales vibratorias en el dominio de la frecuencia para la identificación de dicho modos se realizará en el entorno de programación MATLAB, haciendo uso de una herramienta propia que implementa los métodos de cálculo y los algoritmos necesarios para tal fin. Asimismo, simularemos el comportamiento del resonador mediante el método de elementos finitos (FEM), utilizando las aplicaciones ANSYS y SYSNOISE, considerando diferentes condiciones frontera en el modelo generado. Los resultados aquí obtenidos serán de utilidad para complementar aquellos obtenidos de forma experimental a la hora de extraer conclusiones prácticas del análisis realizado. SUMMARY. This Master's Thesis intends to carry out the analysis of the vibratory behaviour of resonance absorbers, consisting of a thin and lightweight panel mounted at a distance from a rigid wall. Such systems are commonly used as sound absorption systems for mid-low frequency in room acoustics applications. The analysis will emphasize the influence of mechanical-acoustic coupling between the vibrating plate (structure) and the air cushion (acoustic element) enclosed behind it. First of all, we are performing the experimental modal analysis of the resonance absorber under test from the vibrational response measurements, in order to characterize its behaviour based on its first bending coupled-modes. The analysis of vibration signals in the frequency domain for the identification of such modes will be made in MATLAB programming environment, using a proprietary tool that implements the calculation methods and algorithms needed for this purpose. Furthermore, we are simulating the behaviour of the resonance absorber applying the Finite Element Method (FEM) – using ANSYS and SYSNOISE applications - considering different boundary conditions in the model created. The results from the simulation will be useful to complement those obtained experimentally when drawing practical conclusions from this analysis.
Resumo:
Impulse response measurements are carried out in laboratory facilities at Ecophon, Sweden, simulating a typical classroom with varying suspended ceilings and furniture arrangements. The aim of these measurements is to build a reliable database of acoustical parameters in order to have enough data to validate the new acoustical simulation tool which is under development at Danmarks Tekniske Universitet, Denmark. The different classroom configurations are also simulated using ODEON Room Acoustics software and are compared with the measurements. The resulting information is essential for the development of the acoustical simulation tool because it will enable the elimination of prediction errors, especially those below the Schroeder frequency. The surface impedance of the materials used during the experiments is measured in a Kundt’s tube at DTU, in order to characterize them as accurately as possible at the time of incorporation into the model. A brief study about porous materials frequently used in classrooms is presented. Wide diferences are found between methods of measuring absorption coefficients and local or extended assumptions. RESUMEN. Mediciones de Respuesta al Impulso son llevadas a cabo en las instalaciones con que cuenta la empresa Ecophon en su sede central de Hyllinge, Suecia. En una de sus salas, se recrean diferentes configuraciones típicas de aula, variando la altura y composición de los techos, colocando paneles absorbentes de pared e incluyendo diferentes elementos mobiliario como pupitres y sillas. Tres diferentes materiales absorbentes porosos de 15, 20 y 50 mm de espesor, son utilizados como techos suspendidos así como uno de 40 mm es utilizado en forma de paneles. Todas las medidas son realizadas de acuerdo al estándar ISO 3382, utilizando 12 combinaciones de fuente sonora y micrófono para cada configuración, así como respetando las distancias entre ellos establecidas en la norma. El objetivo de toda esta serie de medidas es crear una base de datos de parámetros acústicos tales como tiempo de reverberación, índice de claridad o índice de inteligibilidad medidos bajo diferentes configuraciones con el objeto de que éstos sirvan de referencia para la validación de una nueva herramienta de simulación acústica llamada PARISM que está siendo desarrollada en este momento en la Danmarks Tekniske Universitet de Copenhague. Esta herramienta tendrá en cuenta la fase, tanto en propagación como en reflexión, así como el comportamiento angulodependiente de los materiales y la difusión producida por las superficies. Las diferentes configuraciones de aula recreadas en Hyllinge, son simuladas también utilizando el software de simulación acústica ODEON con el fin de establecer comparaciones entre medidas y simulaciones para discutir la validez de estas ultimas. La información resultante es esencial para el desarrollo de la nueva herramienta de simulación, especialmente los resultados por debajo de la frecuencia de corte de Schroeder, donde ODEON no produce predicciones precisas debido a que no tiene en cuenta la fase ni en propagación ni en reflexión. La impedancia de superficie de los materiales utilizados en los experimentos, todos ellos fabricados por la propia empresa Ecophon, es medida utilizando un tubo de Kundt. De este modo, los coeficientes de absorción de incidencia aleatoria son calculados e incorporados a las simulaciones. Además, estos coeficientes también son estimados mediante el modelo empírico de Miki, con el fin de ser comparados con los obtenidos mediante otros métodos. Un breve estudio comparativo entre coeficientes de absorción obtenidos por diversos métodos y el efecto producido por los materiales absorbentes sobre los tiempos de reverberación es realizado. Grandes diferencias son encontradas, especialmente entre los métodos de tubo de impedancia y cámara reverberante. La elección de reacción local o extendida a la hora de estimar los coeficientes también produce grandes diferencias entre los resultados. Pese a que la opción de absorción angular es activada en todas las simulaciones realizadas con ODEON para todos los materiales, los resultados son mucho más imprecisos de lo esperado a la hora de compararlos con los valores extraidos de las medidas de Respuesta al Impulso. En salas como las recreadas, donde una superficie es mucho más absorbente que las demás, las ondas sonoras tienden a incidir en la superficie altamente absorbente desde ángulos de incidencia muy pequeños. En este rango de ángulos de incidencia, las absorciones que presentan los materiales absorbentes porosos estudiados son muy pequeñas, pese a que sus valores de coeficientes de absorción de incidencia aleatoria son altos. Dado que como descriptor de las superficies en ODEON se utiliza el coeficiente de absorción de incidencia aleatoria, los tiempos de reverberación son siempre subestimados en las simulaciones, incluso con la opción de absorción angular activada. Esto es debido a que el algoritmo que ejecuta esta opción, solo tiene en cuenta el tamaño y posición de las superficies, mientras que el comportamiento angulodependiente es diferente para cada material. Es importante destacar, que cuando la opción es activada, los tiempos simulados se asemejan más a los medidos, por lo tanto esta característica sí produce ciertas mejoras pese a no modelar la angulodependencia perfectamente. Por otra parte, ODEON tampoco tiene en cuenta el fenómeno de difracción, ni acepta longitudes de superficie menores de una longitud de onda a frecuencias medias (30 cm) por lo que en las configuraciones que incluyen absorbentes de pared, los cuales presentan un grosor de 4 cm que no puede ser modelado, los tiempos de reverberación son siempre sobreestimados. Para evitar esta sobreestimación, diferentes métodos de correción son analizados. Todas estas deficiencias encontradas en el software ODEON, resaltan la necesidad de desarrollar cuanto antes la herramienta de simulación acústica PARISM, la cual será capaz de predecir el comportamiento del campo sonoro de manera precisa en este tipo de salas, sin incrementar excesivamente el tiempo de cálculo. En cuanto a los parámetros extraidos de las mediciones de Respuesta al Impulso, bajo ninguna de las configuraciones recreadas los tiempos de reverberación cumplen con las condiciones establecidas por la regulación danesa en materia de edificación. Es importante destacar que los experimentos son llevados a cabo en un edificio construido para uso industrial, en el que, pese a contar con un buen aislamiento acústico, los niveles de ruido pueden ser superiores a los existentes dentro del edificio donde finalmente se ubique el aula. Además, aunque algunos elementos de mobiliario como pupitres y sillas son incluidos, en una configuración real de aula normalmente aparecerían algunos otros como taquillas, que no solo presentarían una mayor absorción, sino que también dispersarían las ondas incidentes produciendo un mejor funcionamiento del techo absorbente. Esto es debido a que las ondas incidirían en el techo desde una mayor variedad de ángulos, y no solo desde ángulos cercanos a la dirección paralela al techo, para los cuales los materiales presentan absorciones muy bajas o casi nulas. En relación a los otros parámetros como índice de claridad o índice de inteligibilidad extraidos de las medidas, no se han podido extraer conclusiones válidas dada la falta de regulación existente. Sin embargo, el efecto que produce sobre ellos la inclusión de techos, paneles de pared y mobiliario sí es analizada, concluyendo que, como era de esperar, los mejores resultados son obtenidos cuando todos los elementos están presentes en la sala en el mismo momento.
Resumo:
Ultrasonic tomography is a powerful tool for identifying defects within an object or structure. This method can be applied on structures where x-ray tomography is impractical due to size, low contrast, or safety concerns. By taking many ultrasonic pulse velocity (UPV) readings through the object, an image of the internal velocity variations can be constructed. Air-coupled UPV can allow for more automated and rapid collection of data for tomography of concrete. This research aims to integrate recent developments in air-coupled ultrasonic measurements with advanced tomography technology and apply them to concrete structures. First, non-contact and semi-contact sensor systems are developed for making rapid and accurate UPV measurements through PVC and concrete test samples. A customized tomographic reconstruction program is developed to provide full control over the imaging process including full and reduced spectrum tomographs with percent error and ray density calculations. Finite element models are also used to determine optimal measurement configurations and analysis procedures for efficient data collection and processing. Non-contact UPV is then implemented to image various inclusions within 6 inch (152 mm) PVC and concrete cylinders. Although there is some difficulty in identifying high velocity inclusions, reconstruction error values were in the range of 1.1-1.7% for PVC and 3.6% for concrete. Based upon the success of those tests, further data are collected using non-contact, semi-contact, and full contact measurements to image 12 inch (305 mm) square concrete cross-sections with 1 inch (25 mm) reinforcing bars and 2 inch (51 mm) square embedded damage regions. Due to higher noise levels in collected signals, tomographs of these larger specimens show reconstruction error values in the range of 10-18%. Finally, issues related to the application of these techniques to full-scale concrete structures are discussed.