943 resultados para Corrosion testing and monitoring


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a brief review of major techniques applied in carbon dioxide corrosion testing and monitoring. The focus is on the advantages and disadvantages of variously designed testing apparatus and monitoring devices for localized corrosion detection and assessment. Critical factors affecting the reliability and accuracy of major corrosion testing techniques are briefly discussed. It is concluded that major reasons that lead to reporting of inaccurate corrosion rates and patterns include: (i) limitations in conventional electrochemical and nonelectrochemical methods for localized corrosion measurements, and difficulties in data interpretation; (ii) challenges in simulating localized corrosion mechanisms and their changes with the extension of corrosion testing. Underdeposit corrosion testing is presented as a case to illustrate challenges in simulating localized corrosion processes and mechanisms. Experiment data have been presented to show potential difficulties of the artificial pit electrode method in evaluating underdeposit corrosion and its inhibitors. The wire beam electrode method has been used to study underdeposit corrosion with and without inhibitor present. Several interesting corrosion mechanisms have been revealed at different stages of underdeposit corrosion processes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many researchers in the field of civil structural health monitoring have developed and tested their methods on simple to moderately complex laboratory structures such as beams, plates, frames, and trusses. Field work has also been conducted by many researchers and practitioners on more complex operating bridges. Most laboratory structures do not adequately replicate the complexity of truss bridges. This paper presents some preliminary results of experimental modal testing and analysis of the bridge model presented in the companion paper, using the peak picking method, and compares these results with those of a simple numerical model of the structure. Three dominant modes of vibration were experimentally identified under 15 Hz. The mode shapes and order of the modes matched those of the numerical model; however, the frequencies did not match.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new electrochemical method was developed to investigate crevice corrosion and its inhibitors. A wire beam electrode was used to allow electrochemical parameters to be measured directly from the crevice area. As an example, oil stain was investigated using this method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

© 2015 by Nace International. This paper presents new experimental evidences on the capability of a novel electrochemical corrosion monitoring sensor, which was recently conceived, for measuring localized corrosion under disbonded pipeline coatings. The sensor's design includes an artificial crevice for simulating the conditions developed under disbonded coatings and an electrode array for measuring current density distribution over its surface. The sensor capabilities were further evaluated by studying the dependency of corrosion patterns and current density distribution on the Cathodic Protection (CP) potential applied upon immersion in an aqueous environment. At the less negative CP potential, a good correlation was found between the inhomogeneous corrosion distribution under the disbonded coating as measured by the sensor and actual metal loss and corrosion attack observed on its surface at the end of the test. At more negative CP potentials no corrosion was detected or observed on the sensor's surface. In addition, characteristic changes in the cathodic current distribution at different CP potentials illustrated the possibility of employing the sensor to obtain valuable feedback on the performance of a given CP setup, without requiring its interruption or compensation of IR-drops. Furthermore, the sensor's capability to detect some of the effects of overprotection were shown at the most negative CP potential applied.