903 resultados para Coronary Sinus


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present the case of a 54-year-old female with a previous history of lung fibrosis secondary to methotrexate used for rheumatoid arthritis who was referred to cardiology evaluation due to precordial pain. Echocardiography showed biatrial enlargement with an enlarged coronary sinus and tubular image posterior to the heart. On the coronary angiogram, the right coronary artery was enlarged, and a distal fistula was identified. The patient underwent a contrast enhanced cardiac computed tomography which demonstrated an aneurysmatic right coronary artery with a distal fistula to the right atrium and coronary sinus. As the chest pain did not recur and there was a high risk of the intervention to correct coronary fistula, the patient remained on conservative treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

1. The protection offered by intermittent perfusion of of cardioplegic solution through the coronary sinus was investigated in isovolumic blood-perfused dog heart preparations submitted to 60 min of ischemia and 45 min of reperfusion.2. The preparations were divided into three treatment groups: a) coronary sinus, consisting of preparations (N = 10) perfused through the coronary sinus under 40 cm water pressure; b) aortic, consisting of preparations (N = 10) perfused through the aortic stump under 100 mmHg pressure; c) control, consisting of hearts (N = 9) that were not perfused with cardioplegic solution.3. Properties of contractile capacity and relaxation were markedly impaired in the control group but were preserved to a comparable extent in the groups perfused with cardioplegic solution through the aorta and coronary sinus. Developed pressure decreased in the control group (before ischemia: 70 +/- 5.5 mmHg; after reperfusion: 35 +/- 12 mmHg; P < 0.05) and didn't vary in the aortic group (from 69 +/- 4 mmHg to 65 +/- 13 mmHg; P > 0.05) and coronary sinus group (from 69 +/- 4.6 mmHg to 60 +/- 10 mmHg; P > 0.05). Myocardial relaxation was evaluated by the +/- dp/dt ratio. In the control group there was impairment of myocardial relaxation as indicated by an increase of this index after reperfusion (from 1.05 +/- 0.05 to 1.46 +/- 0.23; P < 0.05), whereas in the aortic (from 1.10 +/- 0.13 to 1.15 +/- 0.20; P > 0.05) and the coronary sinus (from 1.03 +/- 0.14 to 1.08 +/- 0.16; P > 0.05) groups there was no variation. Ultrastructural changes in the myocardium were negligible in all three groups at the end of reperfusion.4. We conclude that intermittent perfusion of a hypothermic cardioplegic solution through the coronary sinus is effective for the protection of the myocardium during total ischemia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The coronary sinus was investigated in 34 normal adult dogs, in order to verify its formation, tributaries, length and the valves, as well as the relationship of the venous walls to the epicardium and to the myocardium. The valve of the coronary sinus was observed in only 4 cases (1.7 %). In 30 cases (98.3 %) the ostium of the coronary sinus was lacking a valve. The valve of Vieussens double, was found at the level of the transition between the great cardiac vein and the coronary sinus, as well as others parietal venous valves. A comparison with the human pattern was made, particularly regarding the action of the valve of the coronary sinus and the formation of the sinus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The relationship between coronary sinus blood oxygen tension (CSPO 2) and myocardial oxygen tension (MPO 2) variations during cardiac ischemia and reperfusion was studied in anesthetized open-chest dogs. Oxygen tension was measured by a polarographic method. Ischemia resulted in a slightly decreased CSPO 2 and a more pronounced reduction of MPO 2. After reperfusion the CSPO 2 rose rapidly and transiently before it returned gradually to the control level. By contrast, during the recovery period, the MPO 2 increased slowly, with recovery occurring long after the peak of CSPO 2. These data suggest that during the reperfusion phase, the CSPO 2 variation is probably due to opening of the myocardial arteriovenous shunts instead of an increase of flow through the myocardial capillary bed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors studied the formation, tributaries, lenght and the ostium of the coronary sinus, as well as the relationship of the venous walls to the myocardium and to the epicardium. The observations were made out of 143 hearts of subjects of different ages, and it was found that the most frequent display of the coronary sinus valve was a semilunar form (52 adults, 15 youngsters, 2 children, 3 newborn); it was also found valves in a cribiform or septal form. The absence of the valve of coronary sinus was noted in 53 cases (42 adults, 9 youngsters, 2 newborn). The valve of Vieussens was found, in some cases, at the level of the transition between the great cardiac vein and the coronary sinus, as well as others single or double parietal venous valves. The action of the valve of coronary sinus is also discussed by the authors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the safety and outcomes of mitral isthmus (MI) linear ablation with temporary spot occlusion of the coronary sinus (CS). Background: CS blood flow cools local tissue precluding transmurality and bidirectional block across MI lesion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Persistent atrial fibrillation (AF) ablation may lead to partial disconnection of the coronary sinus (CS). As a result, disparate activation sequences of the local CS versus contiguous left atrium (LA) may be observed during atrial tachycardia (AT). We aimed to evaluate the prevalence of this phenomenon and its impact on activation mapping.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE This study tested the hypotheses that intermittent coronary sinus occlusion (iCSO) reduces myocardial ischaemia, and that the amount of ischaemia reduction is related to coronary collateral function. DESIGN Prospective case-control study with intraindividual comparison of myocardial ischaemia during two 2-min coronary artery balloon occlusions with and without simultaneous iCSO by a balloon-tipped catheter. SETTING University Hospital. PATIENTS 35 patients with chronic stable coronary artery disease. INTERVENTION 2-min iCSO. MAIN OUTCOME MEASURES Myocardial ischaemia as assessed by intracoronary (i.c.) ECG ST shift at 2 min of coronary artery balloon occlusion. Collateral flow index (CFI) without iCSO, that is, the ratio between mean distal coronary occlusive (Poccl) and mean aortic pressure (Pao) both minus central venous pressure. RESULTS I.c. ECG ST segment shift (elevation in all) at the end of the procedure with iCSO versus without iCSO was 1.33±1.25 mV versus 1.85±1.45 mV, p<0.0001. Regression analysis showed that the degree of i.c. ECG ST shift reduction during iCSO was related to CFI, best fitting a Lorentzian function (r(2)=0.61). Ischaemia reduction with iCSO was greatest at a CFI of 0.05-0.20, whereas in the low and high CFI range the effect of iCSO was absent. CONCLUSIONS ICSO reduces myocardial ischaemia in patients with chronic coronary artery disease. Ischaemia reduction by iCSO depends on coronary collateral function. A minimal degree of collateral function is necessary to render iCSO effective. ICSO cannot manifest an effect when collateral function prevents ischaemia in the first place.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Atrial tachycardias (AT) during or after ablation of atrial fibrillation frequently pose a diagnostic challenge. We hypothesized that both the patterns and the timing of coronary sinus (CS) activation could facilitate AT mapping. METHODS AND RESULTS A total of 140 consecutive postpersistent atrial fibrillation ablation patients with sustained AT were investigated by conventional mapping. CS activation pattern was defined as chevron or reverse chevron when the activations recorded on both the proximal and the distal CS dipoles were latest or earliest, respectively. The local activation of mid-CS was timed with reference to Ppeak-Ppeak (P-P) interval in lead V1. A ratio, mid-CS activation time to AT cycle length, was computed. Of 223 diagnosed ATs, 124 were macroreentrant (56%) and 99 were centrifugal (44%). When CS activation was chevron/reverse chevron (n=44; 20%), macroreentries were mostly roof dependent. With reference to P-P interval, mid-CS activation timing showed specific consistency for peritricuspid and perimitral AT. Proximal to distal CS activation pattern and mid-CS activation at 50% to 70% of the P-P interval (n=30; 13%) diagnosed peritricuspid AT with 81% sensitivity and 89% specificity. Distal to proximal CS activation and mid-CS activation at 10% to 40% of the P-P interval (n=44; 20%) diagnosed perimitral AT with 88% sensitivity and 75% specificity. CONCLUSIONS The analysis of the patterns and timing of CS activation provides a rapid stratification of most likely macroreentrant ATs and points toward the likely origin of centrifugal ATs. It can be included in a stepwise diagnostic approach to rapidly select the most critical mapping maneuvers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS In 1999 the consensus statement "living anatomy of the atrioventricular junctions" was published. With that new nomenclature the former posteroseptal accessory pathway (APs) are termed paraseptal APs. The aim of this study was to identify ECG features of manifest APs located in this complex paraseptal space. METHODS AND RESULTS ECG characteristics of all patients who underwent radiofrequency ablation of an AP during a 3 year period were analyzed. Of the 239 patients with one or more APs, 30 patients had a paraseptal AP with preexcitation. Compared to APs within the coronary sinus (CS) or the middle cardiac vein (MCV) the right sided paraseptal APs significantly more often showed an isoelectric delta wave in lead II and/or a negative delta wave in aVR. The left sided paraseptal APs presented a negative delta wave in II significantly more often compared to the right sided APs. CONCLUSIONS According to the site of radiofrequency ablation, paraseptal APs are classified into 4 subgroups: paraseptal right, paraseptal left, inside the CS or inside the MCV. Subtle differences in preexcitation patterns of the delta wave as well as of the QRS complex exist. However, the definitive localization of APs remains reserved to the periinterventional intracardiac electrogram analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS To investigate a pressure-controlled intermittent coronary sinus occlusion (PICSO) system in an ischaemia/reperfusion model. METHODS AND RESULTS We randomly assigned 18 pigs subjected to 60 minutes ischaemia by left anterior descending (LAD) coronary artery balloon occlusion to PICSO (n=12, groups A and B) or to controls (n=6, group C). PICSO started 10 minutes before (group A), or 10 minutes after (group B) reperfusion and was maintained for 180 minutes. A continuous drop of distal LAD pressure was observed in group C. At 180 minutes of reperfusion, LAD diastolic pressure was significantly lower in group C compared to groups A and B (p=0.02). LAD mean pressure was significantly less than the systemic arterial mean pressure in group C (p=0.02), and the diastolic flow slope was flat, compared to groups A and B (p=0.03). IgG and IgM antibody deposition was significantly higher in ischaemic compared to non-ischaemic tissue in group C (p<0.05). Significantly more haemorrhagic lesions were seen in the ischaemic myocardium of group C, compared to groups A and B (p=0.002). The necrotic area differed non-significantly among groups. CONCLUSIONS PICSO was safe and effective in improving coronary perfusion pressure and reducing antibody deposition consistent with reduced microvascular obstruction and ischaemia/reperfusion injury.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Heart failure (HF) prevention strategies require biomarkers that identify disease manifestation. Increases in B-type natriuretic peptide (BNP) correlate with increased risk of cardiovascular events and HF development. We hypothesize that coronary sinus serum from a high BNP hypertensive population reflects an active pathological process and can be used for biomarker exploration. Our aim was to discover differentially expressed disease-associated proteins that identify patients with ventricular dysfunction and HF.

METHODS AND RESULTS: Coronary sinus serum from 11 asymptomatic, hypertensive patients underwent quantitative differential protein expression analysis by 2-dimensional difference gel electrophoresis. Proteins were identified using mass spectrometry and then studied by enzyme-linked immunosorbent assay in sera from 40 asymptomatic, hypertensive patients and 105 patients across the spectrum of ventricular dysfunction (32 asymptomatic left ventricular diastolic dysfunction, 26 diastolic HF, and 47 systolic HF patients). Leucine-rich α2-glycoprotein (LRG) was consistently overexpressed in high BNP serum. LRG levels correlate significantly with BNP in hypertensive, asymptomatic left ventricular diastolic dysfunction, diastolic HF, and systolic HF patient groups (P≤0.05). LRG levels were able to identify HF independent of BNP. LRG correlates with coronary sinus serum levels of tumor necrosis factor-α (P=0.009) and interleukin-6 (P=0.021). LRG is expressed in myocardial tissue and correlates with transforming growth factor-βR1 (P<0.001) and α-smooth muscle actin (P=0.025) expression.

CONCLUSIONS: LRG was identified as a serum biomarker that accurately identifies patients with HF. Multivariable modeling confirmed that LRG is a stronger identifier of HF than BNP and this is independent of age, sex, creatinine, ischemia, β-blocker therapy, and BNP.