43 resultados para Coronaire


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Percutaneous transluminal coronary angioplasty (PTCA) is a widely accepted treatment of symptomatic coronary heart disease providing prompt and prolonged clinical, improvement in most patients. We have examined the value of this therapy in a group of 91 patients in their eighth decade treated by 133 consecutive angioplasties. Most patients had refractory or instable angor in spite of optimal pharmacotherapy. Multivessel disease was present in 67% and maintained left-ventricular function in 92% of the patients. The angiographic success rate of PTCA was 84%; technical failures occurred in 12% and adverse events in 14%. Two patients died. The rate of symptomatic restenosis was 24%. Survival and patients free of myocardial events were at 89% and 60%, respectively, estimated by Kaplan-Meier analysis. PTCA is an efficient and acceptable treatment for the elderly patient with severe and drug-resistant angina. Two years after PTCA the majority of patients was asymptomatic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The time-lag between coronary occlusion and irreversible damage to the myocardium is ill-defined in man. In 10 patients the changes in left ventricular function have been studied after coronary occlusion during diagnostic or therapeutic cardiac catheterization of 1-2 hours' duration. Revascularization was achieved either surgically or through intracoronary streptokinase infusion. The interval between occlusion and onset of extracorporal circulation or reopening was 61 to 119 minutes. Despite enzyme elevation (CPK, CK-MB, SGOT) and appearance of Q-waves in 5 patients, no significant alteration of left ventricular function was noted on repeat cardiac catheterization 10 to 230 days after the accident. These observations, suggest that coronary occlusion of 1-2 hours' duration fails to produce significant irreversible damage to the myocardium despite electrocardiographic and enzymatic signs of myocardial infarction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contexte: Le traitement de l'angine de poitrine par angioplastie coronaire transluminale percutanée (PTCA) est efficace et peu invasif, mais son impact sur la qualité de vie des patients a été relativement peu étudié avec des questionnaires spécifiques. Méthode: Durant 6 mois, tous les patients souffrant d'une angine de poitrine pour qui une PTCA élective était envisagée, et qui étaient disponibles pour un suivi à 6 mois ont été inclus dans l'étude. Le questionnaire spécifique «Seattle Angina Questionnaire» (SAQ) a été utilisé le jour avant et 6 mois après la procédure. La décision d'implanter un stent était laissée au cardiologue au moment de la procédure. Résultats: 112 patients ont été initialement inclus. Trente-neuf d'entre eux ont été traités avec une PTCA, et 62 avec une PTCA et l'implantation de stent. Il n'y avait pas de différence de sexe, d.âge, de sévérité de l'angine de poitrine, et de type de lésion coronaire entre les deux groupes. Un suivi à 6 mois a été possible pour 101 patients (90% de la cohorte initiale). La qualité de vie a été améliorée de façon spectaculaire dans 4 des 5 dimensions du SAQ (limites physiques, stabilité de l'angor, fréquence de l'angor, perception de l'angor, p <0,001). Seule, la satisfaction avec le traitement était pire lors du suivi qu'avant l'intervention (p = 0,03), en particulier la satisfaction avec les explications reçues, la conviction que tous les moyens avaient été utilisés pour le traitement, et la satisfaction globale. L'implantation d'un stent n'a eu aucun impact sur ces résultats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Summary Background: Percutaneous transluminal coronary angioplasty (PTCA) is an effective and minimally invasive treatment for angina pectoris, but its impact on patient's quality of life has not been extensively studied with specific questionnaires. Methods: Over a 6 month period, ail patients suffering from angina, planned for elective PTCA, and available for a 6 months follow-up, were included in the study. The specific "Seattle Angina Questionnaire" (SAQ) was administered the day before and 6 months after PTCA. The decision to implant a coronary stent was left to the cardiologist in charge of the procedure. Results: 112 patients were initially included (39 PTCA and 62 PTCA with stent im-plantation). There was no difference in gender, age, angina severity and type of coronary lesion between the two groups. Follow-up at 6 months was available for 101 patients (90%). Quality of life was dramatically improved in 4 of 5 SAQ dimensions (physical limitation, angina stability, angina frequency, disease perception, p <0.001). Only treatment satisfaction was worse at follow-up then before the procedure (p = 0.03), in particular satisfaction with received explanations, belief that everything possible was donc to treat angina, and global satisfaction. A stent implantation had no impact on these results. Conclusions: PTCA for ischaemic cardiac disease improved not only physical abilities, but also quality of life dramatically. Dissatisfaction with treatment could be corrected with better information during follow-up. SAQ is easy to use and could be selected as a monitoring instrument. Résumé Contexte: Le traitement de l'angine de poitrine par angioplastie coronaire transluminale per-cutanée (PTCA) est efficace et peu invasif, mais son impact sur la qualité de vie des patients a été relativement peu étudié avec des questionnaires spécifiques. Méthode: Durant 6 mois, tous les patients souffrant d'une angine de poitrine pour qui une PTCA élective était envisagée, et qui étaient disponibles pour un suivi à 6 mois ont été inclus dans l'étude. Le questionnaire spécifique «Seattle Angina Questionnaire» (SAQ) a été utilisé le jour avant et 6 mois après la procédure. La décision d'implanter un stent était laissée au cardiologue au moment de la procédure. Résultats: 112 patients ont été initialement inclus. Trente-neuf d'entre eux ont été traités avec une PTCA, et 62 avec une PTCA et l'implantation de stent. Il n'y avait pas de différence de sexe, d'âge, de sévérité de l'angine de poitrine, et de type de lésion coronaire entre les deux groupes. Un suivi à 6 mois a été possible pour 101 patients (90% de la cohorte initiale). La qualité de vie a été améliorée de façon spectaculaire dans 4 des 5 dimensions du SAQ (limites physiques, stabilité de l'angor, fréquence de l'angor, perception de l'angor, p <0,001). Seule, la satisfaction avec le traitement était pire lors du suivi qu'avant l'intervention (p = 0,03), en particulier la satisfaction avec les explications reçues, la conviction que tous les moyens avaient été utilisés pour le traitement, et la satisfaction globale. L'implantation d'un stent n'a eu aucun impact sur ces résultats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapport de synthèse : Mesures de l'aorte ascendante par scanner synchronisé au rythme cardiaque: une étude pilote pour établir des valeurs normatives dans le cadre des futures thérapies par transcathéter. Objectif : L'objectif de cette étude est d'établir les valeurs morphométriques normatives de l'aorte ascendante à l'aide de l'angiographie par scanner synchronisé au rythme cardiaque, afin d'aider au développement des futurs traitements par transcathéter. Matériels et méthodes : Chez soixante-dix-sept patients (âgé de 22 à 83 ans, âge moyen: 54,7 ans), une angiographie par scanner synchronisé au rythme cardiaque a été réalisée pour évaluation des vaisseaux coronaires. Les examens ont été revus afin d'étudier l'anatomie de la chambre de chasse du ventricule gauche jusqu'au tronc brachio-céphalique droit. A l'aide de programmes de reconstructions multiplanaires et de segmentation automatique, différents diamètres et longueurs considérés comme importants pour les futurs traitements par transcathéter ont été mesurés. Les valeurs sont exprimées en moyennes, médianes, maximums, minimums, écart-types et en coefficients de variation. Les variations de diamètre de l'aorte ascendante durant le cycle cardiaque ont été aussi considérées. Résultats : Le diamètre moyen de la chambre de chasse du ventricule gauche était de 20.3+/-3.4 mm. Au niveau du sinus coronaire de l'aorte, il était de 34.2+/-4.1 mm et au niveau de la jonction sinotubulaire il était de 29.7+/-3.4 mm. Le diamètre moyen de l'aorte ascendante était de 32.7+/-3.8 mm. Le coefficient de variation de ces mesures variait de 12 à 17%. La distance moyenne entre l'insertion proximale des valvules aortiques et le départ du tronc brachio-céphalique droit était de 92.6+/-11.8 mm. La distance moyenne entre l'insertion proximale des valvules aortiques et l'origine de l'artère coronaire proximale était de 12.1+/-3.7 mm avec un coefficient de variation de 31%. La distance moyenne entre les deux ostia coronaires était de 7.2+/-3.1 mm avec un coefficient de variation de 43%. La longueur moyenne du petit arc de l'aorte ascendante entre l'artère coronaire gauche et le tronc brachio-céphalique droit était de 52.9+/-9.5 mm. La longueur moyenne de la continuité fibreuse entre la valve aortique et la valvule mitrale antérieure était de 14.6+/-3.3 mm avec un coefficient de variation de 23%. L'aire moyenne de la valve aortique était de 582.0+/-131.9 mm2. La variation du diamètre antéro-postérieur et transverse de l'aorte ascendante était respectivement de 8.4% et de 7.3%. Conclusion Il existe d'importantes variations inter-individuelles dans les mesures de l'aorte ascendante avec cependant des variations intra-individuelles faibles durant le cycle cardiaque. De ce fait, une approche personnalisée pour chaque patient est recommandée dans la confection des futures endoprothèses de l'aorte ascendante. Le scanner synchronisé au rythme cardiaque jouera un rôle prépondérant dans le bilan préthérapeutique. Abstract : The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3+/-3.4, coronary sinus 34.2+/-4.1, sinotubular junction 29.7+-3.4 and mid ascending aorta 32.7+/-3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6111.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1+/-3.7, and between both coronary ostia 7.2+/-3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 X9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.óf3.3, CV 13-43%. Mean aortic valve area was 582+-131.9 mm2. The variations of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUME : Actuellement la brachythérapie endovasculaire reste le seul traitement efficace pour la resténose intrastent. Malgré ceci, la limitation majeure de cette technique est la resténose aux extrémités du stent (effet de bord) due à une couverture incomplète par la source radioactive (geographical miss). Le ballon coupant et qui ne glisse pas pourrait limiter le barotraumatisme engendré par la dilatation et qui avec la diminution de la radiation aux extrémités de la source radioactive, est à la base du geographical miss. Cette étude prospective a pour but d'examiner l'efficacité du traitement de la resténose intrastent par la combinaison d'angioplastie avec cutting ballon et β - irradiation. Le registre « Radiation in Europe NOvoste » (RENO) inclut tous les patients traités par β - irradiation coronaire avec le système Beta-CathTM System (Novoste Corporation, Brussels, Belgium) n'ayant pas été inclus dans une autre étude randomisée. Un premier sous-groupe de ces patients (groupe 1, n=166), représente les patients traités par cutting ballon et β - irradiation intra coronaire. Ce groupe a été défini d'une manière prospective et les résultats cliniques à 6 mois ont été comparés par rapport aux autres patients qui ont reçu un traitement par dilatation coronaire conventionnelle et β - irradiation (groupe 2, n=712). A 6 mois de suivi, on a retrouvé une différence significative entre les 2 groupes par rapport à la nécessité d'une nouvelle revascularisation du vaisseau préalablement traité (10,2% de récidive dans le groupe 1 contre 16,6 % dans le groupe 2 , p=0,04). Le nombre d'événements cardiaques majeurs (mortalité, infarctus du myocarde et revascularisation) a également été diminué de manière significative (10,8% contre 19,2% ; />=0,01). Cette observation a été confirmée par une analyse multivariée qui indique un risque diminué pour les événements cardiaques majeurs à 6 mois, (rapport de côtes : 0,49 ; intervalle de confiance 0,27-0,88 ; p=0,02). Comparé à l'angioplastie coronarienne avec ballon conventionnel, l'utilisation de cutting ballon avant la β - irradiation dans le traitement de la resténose intrastent démontre une meilleure évolution clinique à 6 mois. ABSTRACT: At present, vascular brachytherapy is the only efficient therapy for in-stent restenosis. Nevertheless edge restenosis often relat¬ed to geographical miss has been identified as a major limitation of the technique. The non-slippery cutting balloon has the potential to limit vascular barotraumas which, together with low-dose irradiation at both ends of the radioactive source, are the prerequisite for geographical miss. This prospective study aimed to examine the efficacy of combining cut¬ting balloon angioplasty and brachytherapy for in-stent restenosis. The Radiation in Europe NOvoste (RENO) registry prospectively tracked all patients who had been treated by coronary β-radiation with the Beta-CathTM System (Novoste Corporation. Brussels, Belgium) but were not included in a randomized radiation trial, A subgroup of patients with in-stent restenosis treated by cutting balloon angioplasty and coronary β-radiation (group 1, n = 166) was prospectively defined, and clinical outcomes of patients at 6 months were compared with those of patients treated by conventional angioplasty and coronary β -radiation (group 2, n = 712). At 6-month follow-up, there was a significant difference between groups 1 and 2 in- target vessel revascularization (10.2% versus 16.6% respectively; p = 0.04) and in the incidence of major adverse clinical events (MACE) including, death, myocardial infarction, and revascularization (10.8% versus 19.2%; p= 0.01). This observation was confirmed by a multivariate analysis indicating a. lower risk for MACE at 6 months (odds ratio: 0.49; confidence intervals: 0.27-0.88; p = 0.02). Compared to conventional angioplasty, cutting balloon angio¬plasty prior to coronary beta-radiation with the Beta-CathTM System seems to improve the 6-month clinical outcome in patients with in-stent restenosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Une lésion fonctionnelle ou structurale des artérioles intramurales influence le seuil ischémique du myocarde. Le diagnostic de dysfonction microvasculaire est retenu en présence d'une diminution du flux coronaire maximal et de coronaires angio-graphiquement normales ou presque normales. Un trouble de la microcirculation peut traduire une dysfonction endothéliale chez le sujet diabétique ou hyperlipidémique, ou une lésion structurale ou fonctionnelle dans le cadre de la cardiomyopathie hypertrophique, la sténose aortique ou l'hypertension artérielle. Après recanalisation de l'artère responsable d'un infarctus, la mesure de la fonction microcirculatoire permet d'estimer la qualité de la reperfusion myocardique. L'appréciation de la fonction microvasculaire est un enjeu majeur dans l'évaluation de l'ischémie du myocarde en l'absence de sténose coronaire. Functional or structural lesions in intramural arterioles influence the ischemic threshold of the myocardium. Microvascular dysfonction is evidenced by a decrease in coronary blood flow during maximum hyperemia in the presence of angiographically normal or near-normal coronary arteries. Microvascular dysfonction may reflect endothelial dysfonction in diabetic or hyperlipidemic patients, as well as structural and functional changes in patients with hypertrophic cardiomyopathy, aortic stenosis or hypertension. Assessing microvascular fonction after thrombolysis or primary angioplasty for acute myocardial infarction allows to estimate the quality of myocardial reperfusion. Assessing microvascular fonction is a major component of the evaluation of myocardial ischemia in the absence of coronary artery stenoses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Atherosclerosis is a chronic cardiovascular disease that involves the thicken¬ing of the artery walls as well as the formation of plaques (lesions) causing the narrowing of the lumens, in vessels such as the aorta, the coronary and the carotid arteries. Magnetic resonance imaging (MRI) is a promising modality for the assessment of atherosclerosis, as it is a non-invasive and patient-friendly procedure that does not use ionizing radiation. MRI offers high soft tissue con¬trast already without the need of intravenous contrast media; while modifica¬tion of the MR pulse sequences allows for further adjustment of the contrast for specific diagnostic needs. As such, MRI can create angiographic images of the vessel lumens to assess stenoses at the late stage of the disease, as well as blood flow-suppressed images for the early investigation of the vessel wall and the characterization of the atherosclerotic plaques. However, despite the great technical progress that occurred over the past two decades, MRI is intrinsically a low sensitive technique and some limitations still exist in terms of accuracy and performance. A major challenge for coronary artery imaging is respiratory motion. State- of-the-art diaphragmatic navigators rely on an indirect measure of motion, per¬form a ID correction, and have long and unpredictable scan time. In response, self-navigation (SM) strategies have recently been introduced that offer 100% scan efficiency and increased ease of use. SN detects respiratory motion di¬rectly from the image data obtained at the level of the heart, and retrospectively corrects the same data before final image reconstruction. Thus, SN holds po-tential for multi-dimensional motion compensation. To this regard, this thesis presents novel SN methods that estimate 2D and 3D motion parameters from aliased sub-images that are obtained from the same raw data composing the final image. Combination of all corrected sub-images produces a final image with reduced motion artifacts for the visualization of the coronaries. The first study (section 2.2, 2D Self-Navigation with Compressed Sensing) consists of a method for 2D translational motion compensation. Here, the use of com- pressed sensing (CS) reconstruction is proposed and investigated to support motion detection by reducing aliasing artifacts. In healthy human subjects, CS demonstrated an improvement in motion detection accuracy with simula¬tions on in vivo data, while improved coronary artery visualization was demon¬strated on in vivo free-breathing acquisitions. However, the motion of the heart induced by respiration has been shown to occur in three dimensions and to be more complex than a simple translation. Therefore, the second study (section 2.3,3D Self-Navigation) consists of a method for 3D affine motion correction rather than 2D only. Here, different techniques were adopted to reduce background signal contribution in respiratory motion tracking, as this can be adversely affected by the static tissue that surrounds the heart. The proposed method demonstrated to improve conspicuity and vi¬sualization of coronary arteries in healthy and cardiovascular disease patient cohorts in comparison to a conventional ID SN method. In the third study (section 2.4, 3D Self-Navigation with Compressed Sensing), the same tracking methods were used to obtain sub-images sorted according to the respiratory position. Then, instead of motion correction, a compressed sensing reconstruction was performed on all sorted sub-image data. This process ex¬ploits the consistency of the sorted data to reduce aliasing artifacts such that the sub-image corresponding to the end-expiratory phase can directly be used to visualize the coronaries. In a healthy volunteer cohort, this strategy improved conspicuity and visualization of the coronary arteries when compared to a con¬ventional ID SN method. For the visualization of the vessel wall and atherosclerotic plaques, the state- of-the-art dual inversion recovery (DIR) technique is able to suppress the signal coming from flowing blood and provide positive wall-lumen contrast. How¬ever, optimal contrast may be difficult to obtain and is subject to RR variability. Furthermore, DIR imaging is time-inefficient and multislice acquisitions may lead to prolonged scanning times. In response and as a fourth study of this thesis (chapter 3, Vessel Wall MRI of the Carotid Arteries), a phase-sensitive DIR method has been implemented and tested in the carotid arteries of a healthy volunteer cohort. By exploiting the phase information of images acquired after DIR, the proposed phase-sensitive method enhances wall-lumen contrast while widens the window of opportunity for image acquisition. As a result, a 3-fold increase in volumetric coverage is obtained at no extra cost in scanning time, while image quality is improved. In conclusion, this thesis presented novel methods to address some of the main challenges for MRI of atherosclerosis: the suppression of motion and flow artifacts for improved visualization of vessel lumens, walls and plaques. Such methods showed to significantly improve image quality in human healthy sub¬jects, as well as scan efficiency and ease-of-use of MRI. Extensive validation is now warranted in patient populations to ascertain their diagnostic perfor¬mance. Eventually, these methods may bring the use of atherosclerosis MRI closer to the clinical practice. Résumé L'athérosclérose est une maladie cardiovasculaire chronique qui implique le épaississement de la paroi des artères, ainsi que la formation de plaques (lé¬sions) provoquant le rétrécissement des lumières, dans des vaisseaux tels que l'aorte, les coronaires et les artères carotides. L'imagerie par résonance magné¬tique (IRM) est une modalité prometteuse pour l'évaluation de l'athérosclérose, car il s'agit d'une procédure non-invasive et conviviale pour les patients, qui n'utilise pas des rayonnements ionisants. L'IRM offre un contraste des tissus mous très élevé sans avoir besoin de médias de contraste intraveineux, tan¬dis que la modification des séquences d'impulsions de RM permet en outre le réglage du contraste pour des besoins diagnostiques spécifiques. À ce titre, l'IRM peut créer des images angiographiques des lumières des vaisseaux pour évaluer les sténoses à la fin du stade de la maladie, ainsi que des images avec suppression du flux sanguin pour une première enquête des parois des vais¬seaux et une caractérisation des plaques d'athérosclérose. Cependant, malgré les grands progrès techniques qui ont eu lieu au cours des deux dernières dé¬cennies, l'IRM est une technique peu sensible et certaines limitations existent encore en termes de précision et de performance. Un des principaux défis pour l'imagerie de l'artère coronaire est le mou¬vement respiratoire. Les navigateurs diaphragmatiques de pointe comptent sur une mesure indirecte de mouvement, effectuent une correction 1D, et ont un temps d'acquisition long et imprévisible. En réponse, les stratégies d'auto- navigation (self-navigation: SN) ont été introduites récemment et offrent 100% d'efficacité d'acquisition et une meilleure facilité d'utilisation. Les SN détectent le mouvement respiratoire directement à partir des données brutes de l'image obtenue au niveau du coeur, et rétrospectivement corrigent ces mêmes données avant la reconstruction finale de l'image. Ainsi, les SN détiennent un poten¬tiel pour une compensation multidimensionnelle du mouvement. A cet égard, cette thèse présente de nouvelles méthodes SN qui estiment les paramètres de mouvement 2D et 3D à partir de sous-images qui sont obtenues à partir des mêmes données brutes qui composent l'image finale. La combinaison de toutes les sous-images corrigées produit une image finale pour la visualisation des coronaires ou les artefacts du mouvement sont réduits. La première étude (section 2.2,2D Self-Navigation with Compressed Sensing) traite d'une méthode pour une compensation 2D de mouvement de translation. Ici, on étudie l'utilisation de la reconstruction d'acquisition comprimée (compressed sensing: CS) pour soutenir la détection de mouvement en réduisant les artefacts de sous-échantillonnage. Chez des sujets humains sains, CS a démontré une amélioration de la précision de la détection de mouvement avec des simula¬tions sur des données in vivo, tandis que la visualisation de l'artère coronaire sur des acquisitions de respiration libre in vivo a aussi été améliorée. Pourtant, le mouvement du coeur induite par la respiration se produit en trois dimensions et il est plus complexe qu'un simple déplacement. Par conséquent, la deuxième étude (section 2.3, 3D Self-Navigation) traite d'une méthode de cor¬rection du mouvement 3D plutôt que 2D uniquement. Ici, différentes tech¬niques ont été adoptées pour réduire la contribution du signal du fond dans le suivi de mouvement respiratoire, qui peut être influencé négativement par le tissu statique qui entoure le coeur. La méthode proposée a démontré une amélioration, par rapport à la procédure classique SN de correction 1D, de la visualisation des artères coronaires dans le groupe de sujets sains et des pa¬tients avec maladies cardio-vasculaires. Dans la troisième étude (section 2.4,3D Self-Navigation with Compressed Sensing), les mêmes méthodes de suivi ont été utilisées pour obtenir des sous-images triées selon la position respiratoire. Au lieu de la correction du mouvement, une reconstruction de CS a été réalisée sur toutes les sous-images triées. Cette procédure exploite la cohérence des données pour réduire les artefacts de sous- échantillonnage de telle sorte que la sous-image correspondant à la phase de fin d'expiration peut directement être utilisée pour visualiser les coronaires. Dans un échantillon de volontaires en bonne santé, cette stratégie a amélioré la netteté et la visualisation des artères coronaires par rapport à une méthode classique SN ID. Pour la visualisation des parois des vaisseaux et de plaques d'athérosclérose, la technique de pointe avec double récupération d'inversion (DIR) est capa¬ble de supprimer le signal provenant du sang et de fournir un contraste posi¬tif entre la paroi et la lumière. Pourtant, il est difficile d'obtenir un contraste optimal car cela est soumis à la variabilité du rythme cardiaque. Par ailleurs, l'imagerie DIR est inefficace du point de vue du temps et les acquisitions "mul- tislice" peuvent conduire à des temps de scan prolongés. En réponse à ce prob¬lème et comme quatrième étude de cette thèse (chapitre 3, Vessel Wall MRI of the Carotid Arteries), une méthode de DIR phase-sensitive a été implémenté et testé

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cette étude consiste à comparer les coûts de deux procédures de dilatation artérielle coronaire (angioplastie par ballonet et angioplastie avec pose de stent) uniquement lors de la phase de cathérisation (et non pas de l'ensemble des coûts du séjour hospitalier). La première partie traite de l'importance de la maladie coronarienne, de ses traitements et des objectifs de l'étude. La deuxième partie explique les éléments et la méthode qui composent le calcul des coûts, illustre les résultats et compare les résultats des deux procédures. La troisième partie analyse les résultats en identifiant quels types de coûts sont à l'origine de la différence du coût total et en explicitant les limites et les compléments nécessaires à l'étude.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La cardiomyopathie hypertrophique (CMH) est la maladie cardiaque monogénique la plus fréquente, touchant environ 1 individu sur 500 dans la population (1,2). L'étiologie est familiale dans la majorité des cas avec une transmission de type autosomal dominant à pénétrance variable. Deux gènes principaux sont à l'origine de la maladie chez 70% des patients avec un test génétique positif. Il s'agit des gènes qui codent pour la chaine lourde β de la myosine (MYH7) et la protéine C liant la myosine (MYBPC3) (1-3). La CMH est définie par la présence d'une hypertrophie myocardique « inadéquate » car se développant en l'absence d'une cause d'augmentation de la post-charge (HTA, sténose aortique, membrane sous-aortique), d'une pathologie infiltrative ou d'un entrainement physique (4,5). Le plus souvent asymétrique et affectant préférentiellement le septum, cette hypertrophie s'accompagne dans près de deux tiers des cas d'une obstruction dynamique sous-aortique de la chambre de chasse du ventricule gauche par la valve mitrale (systolic anterior motion ou SAM). Cette obstruction est à la fois la conséquence du rétrécissement de la chambre de chasse par l'hypertrophie septale mais également d'un malpositionnement de la valve mitrale (6-8). On parle alors de Cardiomyopathie Hypertrophique et Obstructive (CMHO). L'obstruction - présente au repos dans 50% des cas et uniquement après manoeuvres de provocation dans l'autre moitié des cas (manoeuvre de Valsalva, test de vasodilatation par nitrite d'amyle) est à l'origine d'un gradient de pression entre le ventricule gauche et l'aorte, et donc d'une surcharge de pression pour le ventricule gauche. Cette surcharge de pression est à l'origine des symptômes classiquement rencontrés soit dyspnée et angor d'effort, présyncope voire syncopes à l'effort. Un gradient sous-aortique de plus de 50 mmHg (mesuré au repos ou après provocation) est considéré comme un gradient à valeur pronostique (6-8) et justifiant un traitement si associé à des symptômes. Le traitement médical des formes obstructives repose sur l'administration de substances inotropes négatives et/ou susceptibles de favoriser la relaxation myocardique tels que les béta-bloqueurs, les antagonistes du calcium et le disopyramide - pris isolément ou en association. Pour les nombreux patients qui deviennent réfractaires ou intolérants à ces traitements, deux interventions peuvent leur être proposées pour lever l'obstruction : une myotomie-myectomie chirurgicale du septum (9,10) ou une alcoolisation du septum par voie percutanée (7,8). Les indications à ces interventions sont les suivantes (7,8,11) : 1. Symptômes (dyspnée de classe fonctionnelle NYHA III ou IV, angor de classe fonctionnelle CCS III ou IV, syncope, ou présyncope) réfractaires au traitement médical ou intolérance du patient au traitement. Une dyspnée de classe II est considérée suffisante dans le cas de jeunes patients. 2. Obstruction sous-aortique avec gradient supérieur ou égal à 50 mmHg, au repos ou après manoeuvre de provocation, associée à une hypertrophie septale et à un mouvement systolique antérieur de la valve mitrale (effet SAM) 3. Anatomiecardiaquefavorableàuntraitementinvasif(épaisseurduseptumde plus de 16 mm) Si la myectomie chirurgicale reste la méthode de référence (12-18), l'alcoolisation septale du myocarde par voie percutanée est devenue un des traitements de choix dans la thérapie de la Cardiomyopathie Hypertrophique Obstructive réfractaire. Elle consiste à repérer par coronarographie l'artère septale nourrissant le septum basal hypertrophié, puis à y introduire un petit ballon pour isoler ce territoire du reste du lit coronaire avant d'y injecter une dose d'alcool à 95% comprise entre 1 et 5 cc. On crée ainsi un infarctus chimique, technique qui fut dans le passé utilisée pour le traitement de certaines tumeurs. Les effets ne sont pas immédiats et nécessitent généralement 2-3 semaines avant de se manifester. On assiste alors à une diminution progressive de l'épaisseur du myocarde nécrosé (7), à la disparition progressive de l'obstruction et à l'amélioration / disparition des symptômes. La question de savoir qui de la chirurgie ou de l'alcoolisation est le plus efficace a été source de nombreux débats (7,11-13,18). Par rapport à la chirurgie, les avantages de la méthode percutanée sont les suivants (11,14,15,18,19) : - Efficacités hémodynamique et fonctionnelle jugées comparable à la chirurgie selon les études - Taux de morbidité et de mortalité très faible et non supérieure à la chirurgie - Absence de sternotomie - Diminution de la durée de l'hospitalisation et surtout de la période de convalescence, le patient pouvant reprendre une activité dès son retour à domicile Certains experts émettent néanmoins des doutes quant à l'innocuité à long terme de la méthode, les zones nécrotiques pouvant servir de terrain arythmogène. Pour ces raisons, la méthode n'est pas recommandée chez les patients de moins de 40 ans (6,8). Le risque majeur de l'alcoolisation du septum proximal réside dans l'induction d'un bloc atrio-ventriculaire complet chimique, le noeud atrio-ventriculaire étant justement situé dans cette région. Ce risque augmente avec la quantité d'alcool administrée et nécessite, si persistance après trois jours, l'implantation d'un pacemaker à demeure. Selon les centres, le taux d'implantation d'un stimulateur varie ainsi entre 7% et 20% (7,14,20). L'efficacité clinique et l'incidence des complications est donc en partie liée à la compétence technique et à l'expérience de l'opérateur (7,14), mais aussi aux choix des patients. Il peut donc varier grandement selon les centres médicaux. L'étude proposée vise à analyser les résultats de l'alcoolisation obtenus à Lausanne, jusqu'à présent pas encore été étudiés, et à les comparer à ceux de la littérature.