993 resultados para Corneal surface
Resumo:
Drosophila melanogaster is a model organism instrumental for numerous biological studies. The compound eye of this insect consists of some eight hundred individual ommatidia or facets, ca. 15 µm in cross-section. Each ommatidium contains eighteen cells including four cone cells secreting the lens material (cornea). High-resolution imaging of the cornea of different insects has demonstrated that each lens is covered by the nipple arrays--small outgrowths of ca. 200 nm in diameter. Here we for the first time utilize atomic force microscopy (AFM) to investigate nipple arrays of the Drosophila lens, achieving an unprecedented visualization of the architecture of these nanostructures. We find by Fourier analysis that the nipple arrays of Drosophila are disordered, and that the seemingly ordered appearance is a consequence of dense packing of the nipples. In contrast, Fourier analysis confirms the visibly ordered nature of the eye microstructures--the individual lenses. This is different in the frizzled mutants of Drosophila, where both Fourier analysis and optical imaging detect disorder in lens packing. AFM reveals intercalations of the lens material between individual lenses in frizzled mutants, providing explanation for this disorder. In contrast, nanostructures of the mutant lens show the same organization as in wild-type flies. Thus, frizzled mutants display abnormal organization of the corneal micro-, but not nano-structures. At the same time, nipples of the mutant flies are shorter than those of the wild-type. We also analyze corneal surface of glossy-appearing eyes overexpressing Wingless--the lipoprotein ligand of Frizzled receptors, and find the catastrophic aberration in nipple arrays, providing experimental evidence in favor of the major anti-reflective function of these insect eye nanostructures. The combination of the easily tractable genetic model organism and robust AFM analysis represents a novel methodology to analyze development and architecture of these surface formations.
Resumo:
How is the corneal epithelium restored when all of it plus the limbus have been eliminated? This investigation explored the possibility that this may be achieved through the conjunctival epithelium. The corneal epithelium of the right eye of 12 rabbits (Oryctolagus cuniculus) was totally scraped followed by surgical excision of the limbus plus 1.0-1.5 mm of the adjacent conjunctiva. Antibiotics and corticosteroids were applied for 1 week after surgery. Histological and immunohistochemical techniques were used to monitor the events taking place on the eye surface 2 weeks and 1, 3 and 6 months thereafter. Initially, the corneal surface was covered by conjunctival-like epithelium. After 1 month and more prominently at 3 and 6 months an epithelium displaying the morphological features of the cornea and reacting with the AE5 antibody was covering the central region. It is likely that the corneal epithelium originated from undifferentiated cells of the conjunctiva interacting with the corneal stroma.
Resumo:
How is the corneal epithelium restored when all of it plus the limbus have been eliminated? This investigation explored the possibility that this may be achieved through the conjunctival epithelium. The corneal epithelium of the right eye of 12 rabbits (Oryctolagus cuniculus) was totally scraped followed by surgical excision of the limbus plus 1.0-1.5 mm of the adjacent conjunctiva. Antibiotics and corticosteroids were applied for 1 week after surgery. Histological and immunohistochemical techniques were used to monitor the events taking place on the eye surface 2 weeks and 1, 3 and 6 months thereafter. Initially, the corneal surface was covered by conjunctival-like epithelium. After 1 month and more prominently at 3 and 6 months an epithelium displaying the morphological features of the cornea and reacting with the AE5 antibody was covering the central region. It is likely that the corneal epithelium originated from undifferentiated cells of the conjunctiva interacting with the corneal stroma.
Resumo:
It has often been found that corneal astigmatism exceeds the amount exhibited by the eye as a whole. This difference is usually referred to as residual astigmatism. Scrutiny of the studies of corneal astigmatismreveal that what has actually been measured is the astigmatic contributionof the anterior corneal surface alone. This anterior surface is easily measured whereas measurement of the posterior corneal surface is much more difficult. A method was therefore developed to measure the radius and toricity of the posterior corneal surface. The method relies upon photography of the first and second Purkinje images in three fixed meridians. Keratometry, comparison of anterior and posterior corneal Purkinje images and pachometricdata were applied to three meridional analysis equations, allowing the posterior corneal surface to be described in sphero-cylindrical form. Measurements were taken from 80 healthy subjects from two distinct age groups. The first consisted of 60 young subjects, mean age 22.04 years and the second consisted of 20 old subjects, mean age 74.64 years. The young group consisted of 28 myopes, 24 emmetropes and 8 hyperopes. The old group consisted of 6 myopes and 14 hyperopes. There was an equal number of males and females in each group. These groupings allowed the study of the effects of age, ametropia and gender on the posterior corneal toricity. The effect of the posterior corneal surface on residual astigmatism was assessed and was found to cause an overall reduction. This reduction was due primarily to the posterior corneal surface being consistently steeper relative to the anterior surface in the vertical meridian compared to the horizontal meridian.
Resumo:
Purpose: To evaluate changes in anterior corneal topography and higher-order aberrations (HOA) after 14-days of rigid gas-permeable (RGP) contact lens (CL) wear in keratoconus subjects comparing two different fitting approaches. Methods: Thirty-one keratoconus subjects (50 eyes) without previous history of CL wear were recruited for the study. Subjects were randomly fitted to either an apical-touch or three-pointtouch fitting approach. The lens’ back optic zone radius (BOZR) was 0.4 mm and 0.1 mm flatter than the first definite apical clearance lens, respectively. Differences between the baseline and post-CL wear for steepest, flattest and average corneal power (ACP) readings, central corneal astigmatism (CCA), maximum tangential curvature (KTag), anterior corneal surface asphericity, anterior corneal surface HOA and thinnest corneal thickness measured with Pentacam were compared. Results: A statistically significant flattening was found over time on the flattest and steepest simulated keratometry and ACP in apical-touch group (all p < 0.01). A statistically significant reduction in KTag was found in both groups after contact lens wear (all p < 0.05). Significant reduction was found over time in CCA (p = 0.001) and anterior corneal asphericity in both groups (p < 0.001). Thickness at the thinnest corneal point increased significantly after CL wear (p < 0.0001). Coma-like and total HOA root mean square (RMS) error were significantly reduced following CL wearing in both fitting approaches (all p < 0.05). Conclusion: Short-term rigid gas-permeable CL wear flattens the anterior cornea, increases the thinnest corneal thickness and reduces anterior surface HOA in keratoconus subjects. Apicaltouch was associated with greater corneal flattening in comparison to three-point-touch lens wear.
Resumo:
Purpose:To describe the indications, the surgical procedure and the clinical outcome of MLAM in the treatment of non traumatic corneal perforations and descemetoceles . Methods:A prospective, non comparative, interventional case series of eight consecutive patients (mean age 59 years old, 6 men and 2 women) with non traumatic corneal perforations or descemetoceles.The surgery consisted in a MLAM transplantation of a cryopreservated human amniotic membrane. The series included: three active herpetic keratitis, one rosacea, one perforation of an hydrops, one cicatricial pemphigoid, one perforation after an abcess in a corneal graft and one perforation after protonbeamtherapy. The clinical outcome included: the follow-up, the integrity of the eye, corneal epithelialization, inflammation and neovascularization, and the integration of the MLAM. Stromal thickness was followed precisely with the slit lamp. A corneal graft was performed at one patient after the MLAM, allowing microscopic investigation of the removed MLAM integrated in the cornea. Results:The mean follow-up was 8.78 months (range 3.57 to 30.17). Amniotic membrane transplantation was successful and reduced inflammation in 7 patients out of 8 ,after one procedure.One patient who presented a large herpetic keratitis epithelial defect with corneal anaesthesia had his MLAM dissolved after two weeks with an aqueous leakage. Epithelium healed within 3 weeks above 7 MLAM and remained stable at 3 months in 7 out of 8 patients. MLAM opacification gradually disappeared over a few months, however, stromal layers filling in the corneal perforations or above the descemetoceles remained stable. Conclusions:MLAM transplantation is a safe, effective and useful technique to cure non traumatic corneal perforations and descemetoceles. It can be performed in emergency despite the presence of an active inflammation or infection. By facilitating epithelialization, reducing inflammation and neovascularization, it allows corneal surface reconstruction in patients with persistent epithelial defects and corneal melting that usually ends in a perforation. For full visual rehabilitation, a delayed penetrating keratoplasty is required.
Resumo:
Whirligig beetles (Gyrinidae) inhabit water surfaces and possess unique eyes which are split into the overwater and underwater parts. In this study we analyze the micro- and nanostructure of the split eyes of two Gyrinidae beetles genera, Gyrinus and Orectochilus. We find that corneae of the overwater ommatidia are covered with maze-like nanostructures, while the corneal surface of the underwater eyes is smooth. We further show that the overwater nanostructures possess no anti-wetting, but the anti-reflective properties with the spectral preference in the range of 450-600 nm. These findings illustrate the adaptation of the corneal nanocoating of the two halves of an insect's eye to two different environments. The novel natural anti-reflective nanocoating we describe may find future technological applications.
Resumo:
Corneal and anterior segment imaging techniques have become a crucial tool in the clinical practice of ophthalmology, with a great variety of applications, such as corneal curvature and pachymetric analysis, detection of ectatic corneal conditions, anatomical study of the anterior segment prior to phakic intraocular lens implantation, or densitometric analysis of the crystalline lens. From the Placido-based systems that allow only a characterization of the geometry of the anterior corneal surface to the Scheimpflug photography-based systems that provide a characterization of the cornea, anterior chamber, and crystalline lens, there is a great variety of devices with the capability of analyzing different anatomical parameters with very high precision. To date, Scheimpflug photography-based systems are the devices providing the more complete analysis of the anterior segment in a non-invasive way. More developments are required in anterior segment imaging technologies in order to improve the analysis of the crystalline lens structure as well as the ocular structures behind the iris in a non-invasive way when the pupil is not dilated.
Resumo:
Purpose: To evaluate the correlation of the magnitude of corneal toricity and power vector components of both corneal surfaces measured with a Scheimpflug photography-based system. Methods: A total of 117 healthy normal eyes of 117 subjects selected randomly with ages ranging from 7 to 80 years were included. All eyes received an anterior segment and corneal analysis with the Sirius system (CSO) evaluating the anterior and posterior mean toricity for 3 and 7 mm (aAST and pAST). The vector components J0 and J45 as well as the overall strength blur (B) were calculated for each keratometric measurement using the procedure defined by Thibos and Horner. Results: The coefficient of correlation between aAST and pAST was 0.52 and 0.62 and the mean anteroposterior ratio for toricity was 0.46 ± 0.39 and 0.57 ± 0.75 for 3 and 7 mm, respectively. These ratios correlated significantly with aAST, anterior corneal J0, and manifest refraction J0 (r ≥ 0.39, P < 0.01). The coefficient of correlation was 0.69 and 0.81 between anterior and posterior J0 for 3 and 7 mm, respectively. For J45, the coefficients were 0.62 and 0.71, respectively. The linear regression analysis revealed that the pAST and power vectors could be predicted from the anterior corneal data (R2 ≥ 0.40, P < 0.01). Conclusions: The toricity and astigmatic power vector components of the posterior corneal surface in the human healthy eye are related to those of the anterior and therefore can be predicted consistently from the anterior toricity and astigmatic power vectors.
Resumo:
Purpose: To evaluate the correlation of the mean curvature and shape factors of both corneal surfaces for different corneal diameters measured with the Scheimpflug photography–based system in keratoconus eyes. Methods: A total of 61 keratoconus eyes of 61 subjects, aged 14 to 64 years, were included in this study. All eyes received a comprehensive ophthalmologic examination including anterior segment and corneal analysis with the Sirius system (CSO): anterior and posterior mean corneal radius for 3, 5, and 7 mm (aKM, pKM), anterior and posterior mean shape factor for 4.5 and 8 mm (ap, pp), central and minimal corneal thickness, and anterior chamber depth. Results: Mean aKM/pKM ratio around 1.20 (range, 0.95–1.48) was found for all corneal diameters (P = 0.24). Weak but significant correlations of this ratio with pachymetric parameters were found (r between −0.28 and −0.34, P < 0.04). The correlation coefficient between aKM and pKM was ≥0.92 for all corneal diameters. A strong and significant correlation was also found between ap and pp (r ≥ 0.86, P < 0.01). The multiple regression analysis revealed that central pKM was significantly correlated with aKM, central corneal thickness, anterior chamber depth, and spherical equivalent (R2 ≥ 0.88, P < 0.01) and that 8 mm pp was significantly correlated with 8 mm ap and age (R2 = 0.89, P < 0.01). Conclusions: Central posterior corneal curvature and shape factor in the keratoconus eye can be consistently predicted from the anterior corneal curvature and shape factor, respectively, in combination with other anatomical and ocular parameters.
Resumo:
Corneal surface laser ablation procedures for the correction of refractive error have enjoyed a resurgence of interest, especially in patients with a possible increased risk of complications after lamellar surgery. Improvements in the understanding of corneal biomechanical changes, the modulation of wound healing, laser technology including ablation profiles and different methods for epithelial removal have widened the scope for surface ablation. This article discusses photorefractive keratectomy, trans-epithelial photorefractive keratectomy, laser-assisted sub-epithelial keratomileusis and epithelial-laser-assisted in situ keratomileusis. © 2010 The Authors. Journal compilation © 2010 Royal Australian and New Zealand College of Ophthalmologists.
Resumo:
Topical ocular drug delivery has always been a challenge for pharmaceutical technology scientists. In the last two decades, many nano-systems have been studied to find ways to overcome the typical problems of topical ocular therapy, such as difficult corneal penetration and poor drug availability. In this study, methoxy poly(ethylene glycol)-hexylsubstituted poly(lactides) (MPEG-hexPLA) micelle formulations, which are promising nanocarriers for poorly water soluble drugs, were investigated for the delivery of Cyclosporin A (CsA) to the eye. As a new possible pharmaceutical excipient, the ocular compatibility of MPEG-hexPLA micelle formulations was evaluated. An in vitro biocompatibility assessment on human corneal epithelial cells was carried out using different tests. Cytotoxicity was studied by using the [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide] (MTT), and clonogenic tests and revealed that the CsA formulations and copolymer solutions were not toxic. After incubation with MPEG-hexPLA micelle formulations, the activation of caspase-dependent and -independent apoptosis as well as autophagy was evaluated using immunohistochemistry by analyzing the localization of four antibodies: (1) anti-caspase 3; (2) anti-apoptotic inducing factor (AIF); (3) anti-IL-Dnase II and (4) anti-microtubule-associated protein 1 light chain 3 (LC3). No apoptosis was induced when the cells were treated with the micelle solutions that were either unloaded or loaded with CsA. The ocular tolerance was assessed in vivo on rabbit eyes by Confocal Laser Scanning Ophthalmoscopy (CLSO), and very good tolerability was seen. The observed corneal surface was comparable to a control surface that was treated with a 0.9% NaCl solution. In conclusion, these results demonstrate that MPEG-hexPLA micelles are promising drug carriers for ocular diseases involving the activation of cytokines, such as dry eye syndrome and autoimmune uveitis, or for the prevention of corneal graft rejection.
Resumo:
Purpose: To evaluate inter- and intraobserver variability of indices crucial for detection of keratoconus progression derived from the Pentacam HR® (high-resolution) tomographer (OCULUS Optikgeräte GmbH, Wetzlar, Germany) in patients with mild to moderate keratoconus. Methods: Three repeated corneal topography measurements in the 25-picture mode by two independent observers were performed. The extent of variability across a large range of measurement parameters was analyzed including anterior and posterior corneal surface measurements, pachymetry values, corneal volume, anterior chamber volume and depth, and iridocorneal angle. The intraclass correlation coefficient (ICC) between and within each investigator was calculated to assess reproducibility and repeatability, respectively. Results: 31 eyes of 20 patients (mean age 31.6, SD ± 8.6) were included. Overall, the repeatability and reproducibility were excellent. The range of variability was reported by calculating the standard deviation of measurements. The detailed results are shown in Table 1. Conclusions: This study shows that the Pentacam HR® tomographer provides reliable measurements in patients with mild to moderate keratoconus. However, all parameters showed a certain range of variability. This should be taken into account when assessing keratoconus progression in order to distinguish true progression from variability in measurements. In addition, the excellent reproducibility suggests that the measurements can be reliably performed by different individuals from one visit to another.
Resumo:
Indolent ulcers are superficial corneal ulcers secondary to several changes on the corneal surface. They are frequently observed in middle-aged Boxer dogs, cause pain of acute onset and requires appropriate treatment. Aiming to evaluate the efficacy of clinical managements on the rate of healing of indolent ulcers, a retrospective study was conducted (1997-2008). Results demonstrated that proteinase inhibitors were the most often prescribed medication, and its administration did not interfere on the healing rate, as well as observed in dogs that received 1% atropine, antibiotics and anti-inflammatory drugs. Healing was delayed in dogs administered orally with vitamin C, but the healing process was faster on those dogs that went through corneal debridement/cauterization. In conclusion, to know the various types of treatments seems to be fundamental for the rapid resolution of the disease. It is suggested that debridement/cauterization, administration of proteinase inhibitor eye drops, prophylactic topical antibiotics and oral vitamin C, should be considered as an effective clinical management for indolent ulcers in Boxer dogs.
Resumo:
Cette thèse porte sur l’étude de l’anatomie de la cornée après 3 techniques de greffe soient, la greffe totale traditionnelle (GTT) et des techniques de greffe lamellaire postérieur (GLP) telles que la greffe lamellaire endothéliale profonde (DLEK) et la greffe endothélium/membrane de Descemet (EDMG) pour le traitement des maladies de l’endothélium, telles que la dystrophie de Fuchs et de la kératopathie de l’aphaque et du pseudophaque. Dans ce contexte, cette thèse contribue également à démontrer l’utilité de la tomographie de cohérence optique (OCT) pour l’étude de l’anatomie des plaies chirurgicales la cornée post transplantation. Au cours de ce travail nous avons étudié l'anatomie de la DLEK, avant et 1, 6, 12 et 24 mois après la chirurgie. Nous avons utilisé le Stratus OCT (Version 3, Carl Zeiss, Meditec Inc.) pour documenter l’anatomie de la plaie. L'acquisition et la manipulation des images du Stratus OCT, instrument qui à été conçu originalement pour l’étude de la rétine et du nerf optique, ont été adaptées pour l'analyse du segment antérieur de l’oeil. Des images cornéennes centrales verticales et horizontales, ainsi que 4 mesures radiaires perpendiculaires à la plaie à 12, 3, 6 et 9 heures ont été obtenues. Les paramètres suivants ont été étudiés: (1) Les espaces (gap) entre les rebords du disque donneur et ceux du receveur, (2) les dénivelés de surface postérieure (step) entre le les rebords du disque donneur et ceux du receveur, (3) la compression tissulaire, (4) le décollement du greffon, 6) les élévations de la surface antérieure de la cornée et 7) la pachymétrie centrale de la cornée. Les mesures d’épaisseur totale de la cornée ont été comparées et corrélées avec celles obtenues avec un pachymètre à ultra-sons. Des mesures d’acuité visuelle, de réfraction manifeste et de topographie ont aussi été acquises afin d’évaluer les résultats fonctionnels. Enfin, nous avons comparé les données de DLEK à celles obtenues de l’EDMG et de la GTT, afin de caractériser les plaies et de cerner les avantages et inconvénients relatifs à chaque technique chirurgicale. Nos résultats anatomiques ont montré des différences importantes entre les trois techniques chirurgicales. Certains des paramètres étudiés, comme le sep et le gap, ont été plus prononcés dans la GTT que dans la DLEK et complètement absents dans l’EDMG. D’autres, comme la compression tissulaire et le décollement du greffon n’ont été observés que dans la DLEK. Ceci laisse entrevoir que la distorsion de la plaie varie proportionnellement à la profondeur de la découpe stromale du receveur, à partir de la face postérieure de la cornée. Moins la découpe s’avance vers la face antérieure (comme dans l’EDMG), moins elle affecte l’intégrité anatomique de la cornée, le pire cas étant la découpe totale comme dans la GTT. Cependant, tous les paramètres d’apposition postérieure sous-optimale et d’élévation de la surface antérieure (ce dernier observé uniquement dans la GTT) finissent par diminuer avec le temps, évoluant à des degrés variables vers un profil topographique plus semblable à celui d’une cornée normale. Ce processus paraît plus long et plus incomplet dans les cas de GTT à cause du type de plaie, de la présence de sutures et de la durée de la cicatrisation. Les valeurs moyennes d’épaisseur centrale se sont normalisées après la chirurgie. De plus, ces valeurs moyennes obtenues par OCT étaient fortement corrélées à celles obtenues par la pachymétrie à ultra-sons et nous n’avons remarqué aucune différence significative entre les valeurs moyennes des deux techniques de mesure. L’OCT s’est avéré un outil utile pour l’étude de l’anatomie microscopique des plaies chirurgicales. Les résultats d’acuité visuelle, de réfraction et de topographie des techniques de GLP ont montré qu’il existe une récupération visuelle rapide et sans changements significatifs de l’astigmatisme, contrairement à la GTT avec et sans suture. La GLP a permis une meilleure conservation de la morphologie de la cornée, et par conséquence des meilleurs résultats fonctionnels que la greffe de pleine épaisseur. Ceci nous permet d’avancer que la GLP pourrait être la technique chirurgicale à adopter comme traitement pour les maladies de l’endothélium cornéen.