995 resultados para Corneal diseases


Relevância:

70.00% 70.00%

Publicador:

Resumo:

As a key component of the ocular surface required for vision, the cornea has been extensively studied as a site for cell and tissue-based therapies. Historically, these treatments have consisted of donor corneal tissue transplants, but cultivated epithelial autografts have become established over the last 15 years as a routine treatment for ocular surface disease. Ultimately, these treatments are performed with the intention of restoring corneal transparency and a smooth ocular surface. The degree of success, however, is often dependent upon the inherent level of corneal inflammation at time of treatment. In this regard, the anti-inflammatory and immuno-modulatory properties of mesenchymal stromal cells (MSC) have drawn attention to these cells as potential therapeutic agents for corneal repair. The origins for MSC-based therapies are founded in part on observations of the recruitment of endogenous bone marrow-derived cells to injured corneas, however, an increasing quantity of data is emerging for MSC administered following their isolation and ex vivo expansion from a variety of tissues including bone marrow, adipose tissue, umbilical cord and dental pulp. In brief, evidence has emerged of cultured MSC, or their secreted products, having a positive impact on corneal wound healing and retention of corneal allografts in animal models. Optimal dosage, route of administration and timing of treatment, however, all remain active areas of investigation. Intriguingly, amidst these studies, have emerged reports of MSC transdifferentiation into corneal cells. Clearest evidence has been obtained with respect to expression of markers associated with the phenotype of corneal stromal cells. In contrast, the evidence for MSC conversion to corneal epithelial cell types remains inconclusive. In any case, the conversion of MSC into corneal cells seems unlikely to be an essential requirement for their clinical use. This field of research has recently become more complicated by reports of MSC-like properties for cultures established from the peripheral corneal stroma (limbal stroma). The relationship and relative value of corneal-MSC compared to traditional sources of MSC such as bone marrow are at present unclear. This chapter is divided into four main parts. After providing a concise overview of corneal structure and function, we will highlight the types of corneal diseases that are likely to benefit from the anti-inflammatory and immuno-modulatory properties of MSC. We will subsequently summarize the evidence supporting the case for MSC-based therapies in the treatment of corneal diseases. In the third section we will review the literature concerning the keratogenic potential of MSC. Finally, we will review the more recent literature indicating the presence of MSC-like cells derived from corneal tissue.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The report of this subcommittee concerns the impact of contact lenses (CLs) on the ocular surface, with a particular emphasis on CL discomfort (CLD). We define the ocular surface, its regional anatomy, and the physiological responses of each region to CL wear.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cette thèse porte sur l’étude de l’anatomie de la cornée après 3 techniques de greffe soient, la greffe totale traditionnelle (GTT) et des techniques de greffe lamellaire postérieur (GLP) telles que la greffe lamellaire endothéliale profonde (DLEK) et la greffe endothélium/membrane de Descemet (EDMG) pour le traitement des maladies de l’endothélium, telles que la dystrophie de Fuchs et de la kératopathie de l’aphaque et du pseudophaque. Dans ce contexte, cette thèse contribue également à démontrer l’utilité de la tomographie de cohérence optique (OCT) pour l’étude de l’anatomie des plaies chirurgicales la cornée post transplantation. Au cours de ce travail nous avons étudié l'anatomie de la DLEK, avant et 1, 6, 12 et 24 mois après la chirurgie. Nous avons utilisé le Stratus OCT (Version 3, Carl Zeiss, Meditec Inc.) pour documenter l’anatomie de la plaie. L'acquisition et la manipulation des images du Stratus OCT, instrument qui à été conçu originalement pour l’étude de la rétine et du nerf optique, ont été adaptées pour l'analyse du segment antérieur de l’oeil. Des images cornéennes centrales verticales et horizontales, ainsi que 4 mesures radiaires perpendiculaires à la plaie à 12, 3, 6 et 9 heures ont été obtenues. Les paramètres suivants ont été étudiés: (1) Les espaces (gap) entre les rebords du disque donneur et ceux du receveur, (2) les dénivelés de surface postérieure (step) entre le les rebords du disque donneur et ceux du receveur, (3) la compression tissulaire, (4) le décollement du greffon, 6) les élévations de la surface antérieure de la cornée et 7) la pachymétrie centrale de la cornée. Les mesures d’épaisseur totale de la cornée ont été comparées et corrélées avec celles obtenues avec un pachymètre à ultra-sons. Des mesures d’acuité visuelle, de réfraction manifeste et de topographie ont aussi été acquises afin d’évaluer les résultats fonctionnels. Enfin, nous avons comparé les données de DLEK à celles obtenues de l’EDMG et de la GTT, afin de caractériser les plaies et de cerner les avantages et inconvénients relatifs à chaque technique chirurgicale. Nos résultats anatomiques ont montré des différences importantes entre les trois techniques chirurgicales. Certains des paramètres étudiés, comme le sep et le gap, ont été plus prononcés dans la GTT que dans la DLEK et complètement absents dans l’EDMG. D’autres, comme la compression tissulaire et le décollement du greffon n’ont été observés que dans la DLEK. Ceci laisse entrevoir que la distorsion de la plaie varie proportionnellement à la profondeur de la découpe stromale du receveur, à partir de la face postérieure de la cornée. Moins la découpe s’avance vers la face antérieure (comme dans l’EDMG), moins elle affecte l’intégrité anatomique de la cornée, le pire cas étant la découpe totale comme dans la GTT. Cependant, tous les paramètres d’apposition postérieure sous-optimale et d’élévation de la surface antérieure (ce dernier observé uniquement dans la GTT) finissent par diminuer avec le temps, évoluant à des degrés variables vers un profil topographique plus semblable à celui d’une cornée normale. Ce processus paraît plus long et plus incomplet dans les cas de GTT à cause du type de plaie, de la présence de sutures et de la durée de la cicatrisation. Les valeurs moyennes d’épaisseur centrale se sont normalisées après la chirurgie. De plus, ces valeurs moyennes obtenues par OCT étaient fortement corrélées à celles obtenues par la pachymétrie à ultra-sons et nous n’avons remarqué aucune différence significative entre les valeurs moyennes des deux techniques de mesure. L’OCT s’est avéré un outil utile pour l’étude de l’anatomie microscopique des plaies chirurgicales. Les résultats d’acuité visuelle, de réfraction et de topographie des techniques de GLP ont montré qu’il existe une récupération visuelle rapide et sans changements significatifs de l’astigmatisme, contrairement à la GTT avec et sans suture. La GLP a permis une meilleure conservation de la morphologie de la cornée, et par conséquence des meilleurs résultats fonctionnels que la greffe de pleine épaisseur. Ceci nous permet d’avancer que la GLP pourrait être la technique chirurgicale à adopter comme traitement pour les maladies de l’endothélium cornéen.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In light of an increasing awareness of the presence of bone marrow (BM)-derived macrophages in the normal cornea and their uncertain role in corneal diseases, it is important that the turnover rate of these resident immune cells be established. The baseline density and distribution of macrophages in the corneal stroma was investigated in Cx3cr1gfp transgenic mice in which all monocyte-derived cells express enhanced green fluorescent protein (eGFP). To quantify turnover, BM-derived cells from transgenic eGFP mice were transplanted into whole-body irradiated wild-type recipients. Additionally, wild-type BM-derived cells were injected into irradiated Cx3cr1+/gfp recipients, creating reverse chimeras. At 2, 4 and 8 weeks post-reconstitution, the number of eGFP+ cells in each corneal whole mount was calculated using epifluorescence microscopy, immunofluorescence staining and confocal microscopy. The total density of myeloid-derived cells in the normal Cx3cr1+/gfp cornea was 366 cells/mm2. In BM chimeras 2 weeks post-reconstitution, 24% of the myeloid-derived cells had been replenished and were predominantly located in the anterior stroma. By 8 weeks post-reconstitution 75% of the myeloid-derived cells had been replaced and these cells were distributed uniformly throughout the stroma. All donor eGFP+ cells expressed low to moderate levels of CD45 and CD11b, with approximately 25% coexpressing major histocompatibility complex class II, a phenotype characteristic of previous descriptions of corneal stromal macrophages. In conclusion, 75% of the myeloid-derived cells in the mouse corneal stroma are replenished after 8 weeks. These data provide a strong basis for functional investigations of the role of resident stromal macrophages versus non-haematopoietic cells using BM chimeric mice in models of corneal inflammation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To determinate the corneal diagnoses of patients underwent Penetrating Keratoplasty (PK) in the university hospital of Sao Jose do Rio Preto, São Paulo, Brazil, and their relation to age group, gender and socioeconomic factors. Methods: Retrospective analysis of 1085 registration forms of patients underwent Penetrating Keratoplasty in the university hospital of Sao Jose do Rio Preto, São Paulo, Brazil, from 2000 to 2009. The surgical indications were then correlated to age group, gender and socioeconomic factors, by chi-square test. Results: Fifty-seven percent of all Penetrating Keratoplasties were performed in male patients, and the mean age was 52.3 years. Most surgeries (90.8%) occurred by means of public health care (SUS). The main diagnosis was leukoma (23%), representing 14% of the indications for PK in males and 9% in females. Leukoma was also the diagnosis in 40% of PK performed in patients older than 60 years and in 94.4% of these surgeries in public health care users. Conclusion: The main indication for Penetrating Keratoplasty was leukoma, predominating in males, ages above 60 years and in public health care users.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To report the successful outcome obtained after fitting a new hybrid contact lens in a cornea with an area of donor-host misalignment and significant levels of irregular astigmatism after penetrating keratoplasty (PKP). Materials and methods: A 41-year-old female with bilateral asymmetric keratoconus underwent PKP in her left eye due to the advanced status of the disease. One year after surgery, the patient referred a poor visual acuity and quality in this eye. The fitting of different types of rigid gas permeable contact lenses was performed, but with an unsuccessful outcome due to contact lens stability problems and uncomfortable wear. Scheimpflug imaging evaluation revealed that a donor-host misalignment was present at the nasal area. Contact lens fitting with a reverse geometry hybrid contact lens (Clearkone, SynergEyes Carlsbad) was then fitted. Visual, refractive, and ocular aberrometric outcomes were evaluated during a 1-year period after the fitting. Results: Uncorrected distance visual acuity improved from a prefitting value of 20/200 to a best corrected postfitting value of 20/20. Prefitting manifest refraction was +5.00 sphere and -5.50 cylinder at 75°, with a corrected distance visual acuity of 20/30. Higher order root mean square (RMS) for a 5 mm pupil changed from a prefitting value of 6.83 µm to a postfitting value of 1.57 µm (5 mm pupil). The contact lens wearing was referred as comfortable, with no anterior segment alterations. Conclusion: The SynergEyes Clearkone contact lens seems to be another potentially useful option for the visual rehabilitation after PKP, especially in cases of donor-host misalignment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To develop a rapid optimized technique of wide-field imaging of the human corneal subbasal nerve plexus. A dynamic fixation target was developed and, coupled with semiautomated tiling software, a rapid method of capturing and montaging multiple corneal confocal microscopy images was created. To illustrate the utility of this technique, wide-field maps of the subbasal nerve plexus were produced in 2 participants with diabetes, 1 with and 1 without neuropathy. The technique produced montages of the central 3 mm of the subbasal corneal nerve plexus. The maps seem to show a general reduction in the number of nerve fibers and branches in the diabetic participant with neuropathy compared with the individual without neuropathy. This novel technique will allow more routine and widespread use of subbasal nerve plexus mapping in clinical and research situations. The significant reduction in the time to image the corneal subbasal nerve plexus should expedite studies of larger groups of diabetic patients and those with other conditions affecting nerve fibers. The inferior whorl and the surrounding areas may show the greatest loss of nerve fibers in individuals with diabetic neuropathy, but this should be further investigated in a larger cohort.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Corneal degeneration may occur with a deposition of lipids or calcium, or both. Calcareous and lipid degeneration may be either primary or secondary, associated with systemic diseases such as primary hyperlipidemia, hyperlipidemia associated with hyperadrenocorticism, and hypothyroidism. The authors report a case of bilateral corneal lipid and calcium degeneration in a 7-year-old female Poodle with hyperadrenocorticism. The condition worsened with Lysodren(R) therapy but responded to surgical excision.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fibrin glue has been researched as an alternative method for tissue synthesis and is known for its capability to promote hemostasis at the application site, good approximation of wound edges and fast healing. The current study consisted in the application of fibrin glue derived from snake venom as treatment for experimental corneal ulcers. Twenty-one dogs had their corneas experimentally prepared through lamellar keratectomy (of standardized diameter and depth). Animals were divided into seven groups of three animals each. Six experimental groups were periodically evaluated and collection was carried out on the 1st, 3rd, 7th, 15 th, 30th and 60th post-operative days, whereas one control group was evaluated throughout the experiment. Analyses consisted in the clinical evolution and in the histopathological study of all operated on eyes. Results indicated that fibrin glue was efficient in repairing keratectomy wounds in dogs and contributed to an earlier healing phenomenon, avoiding edema formation and keeping corneal clearness. The use of fibrin glue derived from snake venom showed to be easy to apply, feasible with animal models and of low cost, avoiding the lesion progress and allowing fast and appropriate corneal healing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To determine the practicability and accuracy of central corneal thickness (CCT) measurements in living chicks utilizing a noncontact, high-speed optical low-coherence reflectometer (OLCR) mounted on a slit lamp. ANIMALS STUDIED Twelve male chicks (Gallus gallus domesticus). Procedures  Measurements of CCT were obtained in triplicate in 24 eyes of twelve 1-day-old anaesthetized chicks using OLCR. Every single measurement taken by OLCR consisted of the average result of 20 scans obtained within seconds. Additionally, corneal thickness was determined histologically after immersion fixation in Karnovsky's solution alone (20 eyes) or with a previous injection of the fixative into the anterior chamber before enucleation (4 eyes). RESULTS Central corneal thickness measurements using OLCR in 1-day-old living chicks provide a rapid and feasible examination technique. Mean CCT measured with OLCR (189.7 ± 3.34 μm) was significantly lower than histological measurements (242.1 ± 47.27 μm) in eyes with fixation in Karnovsky's solution (P = 0.0005). In eyes with additional injection of Karnovsky's fixative into the anterior chamber, mean histologically determined CCT was 195.2 ± 8.25 μm vs. 191.9 ± 8.90 μm with OLCR. A trend for a lower variance was found compared to the eyes that had only been immersion fixed. CONCLUSION Optical low-coherence reflectometry is an accurate examination technique to measure in vivo CCT in the eye of newborn chicks. The knowledge of the thickness of the chick cornea and the ability to obtain noninvasive, noncontact measurements of CCT in the living animal may be of interest for research and development of eye diseases in chick models.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. To compare the efficacy of two forms of eye care (hypromellose and Lacri-Lube combination vs polyethylene/Cling wrap covers) for intensive care patients. Design. Randomised-controlled trial. Setting. University affiliated, tertiary referral hospital. Patients and participants. One hundred ten patients with a reduced or absent blink reflex were followed through until they regained consciousness, were discharged from the facility during study enrolment, died or developed a positive corneal ulcer or eye infection. Interventions. All patients received standard eye cleansing every 2 h. In addition to this, group one (n=60) received a treatment combining hypromellose drops and Lacri-Lube (HL) to each eye every 2 h. Group two (n=50) had polyethylene covers only placed over the eye to create a moisture chamber. Measurements and results. Corneal ulceration was determined using corneal fluorescein stains and mobile slit lamp evaluation, performed daily. No patients had corneal ulceration in the polyethylene cover group, but 4 patients had corneal ulceration in the HL group. Conclusions. Polyethylene covers are as effective as HL in reducing the incidence of corneal damage in intensive care patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine the subbasal nerve density and tortuosity at 5 corneal locations and to investigate whether these microstructural observations correlate with corneal sensitivity. Method: Sixty eyes of 60 normal human subjects were recruited into 1 of 3 age groups, group 1: aged ,35 years, group 2: aged 35–50 years, and group 3: aged .50 years. All eyes were examined using slit-lamp biomicroscopy, noncontact corneal esthesiometry, and slit scanning in vivo confocal microscopy. Results: The mean subbasal nerve density and the mean corneal sensitivity were greatest centrally (14,731 6 6056 mm/mm2 and 0.38 6 0.21 millibars, respectively) and lowest in the nasal mid periphery (7850 6 4947 mm/mm2 and 0.49 6 0.25 millibars, respectively). The mean subbasal nerve tortuosity coefficient was greatest in the temporal mid periphery (27.3 6 6.4) and lowest in the superior mid periphery (19.3 6 14.1). There was no significant difference in mean total subbasal nerve density between age groups. However, corneal sensation (P = 0.001) and subbasal nerve tortuosity (P = 0.004) demonstrated significant differences between age groups. Subbasal nerve density only showed significant correlations with corneal sensitivity threshold in the temporal cornea and with subbasal nerve tortuosity in the inferior and nasal cornea. However, these correlations were weak. Conclusions: This study quantitatively analyzes living human corneal nerve structure and an aspect of nerve function. There is no strong correlation between subbasal nerve density and corneal sensation. This study provides useful baseline data for the normal living human cornea at central and mid-peripheral locations