848 resultados para Conventional coronary stent
Resumo:
OBJECTIVES We sought to evaluate the strategy success and short term clinical outcomes of direct stenting via 5 French (F) diagnostic catheters using a novel bare metal stent with integrated delivery system (IDS) (Svelte Medical Systems, New Providence, NJ) and compare the results to a conventionally treated matched group. METHODS Fifteen consecutive patients with lesions deemed suitable for direct stenting using a bare metal stent were included. The primary endpoint was the strategy success defined as the ability to successfully treat a target lesion via a 5 F diagnostic catheter with a good angiographic result (TIMI III flow, residual stenosis ≤20%). Procedure and fluoroscopy times, contrast agent use, cost, and short-term clinical outcomes were compared to a matched group treated via conventional stenting. RESULTS The primary endpoint was reached in 14/15 patients (93%). There were no significant differences in procedural (58.6 min ± 12.7 vs. 57.4 min ± 14.2) or fluoroscopy times (10.0 min ± 4.3 vs.10.1 min ± 3.9) or contrast agent use (193.7 ml ± 54.8 vs. 181.4 ml ± 35.6). However, there were significant reductions in materials used in the study group compared to the control group equating to cost savings of almost US $600 per case (US $212.44 ± 258.09 vs. US $804.69 ± 468.11; P = 0.001). CONCLUSIONS Direct stenting using a novel bare metal stent with an IDS via 5 F diagnostic catheters is a viable alternative to conventional stenting in selected patients and is associated with significant cost savings.
Resumo:
BACKGROUND: Nanomedicine has the potential to revolutionize medicine and help clinicians to treat cardiovascular disease through the improvement of stents. Advanced nanomaterials and tools for monitoring cell-material interactions will aid in inhibiting stent thrombosis. Although titanium boron nitride (TiBN), titanium diboride, and carbon nanotube (CNT) thin films are emerging materials in the biomaterial field, the effect of their surface properties on platelet adhesion is relatively unexplored. OBJECTIVE AND METHODS: In this study, novel nanomaterials made of amorphous carbon, CNTs, titanium diboride, and TiBN were grown by vacuum deposition techniques to assess their role as potential stent coatings. Platelet response towards the nanostructured surfaces of the samples was analyzed in line with their physicochemical properties. As the stent skeleton is formed mainly of stainless steel, this material was used as reference material. Platelet adhesion studies were carried out by atomic force microscopy and scanning electron microscopy observations. A cell viability study was performed to assess the cytocompatibility of all thin film groups for 24 hours with a standard immortalized cell line. RESULTS: The nanotopographic features of material surface, stoichiometry, and wetting properties were found to be significant factors in dictating platelet behavior and cell viability. The TiBN films with higher nitrogen contents were less thrombogenic compared with the biased carbon films and control. The carbon hybridization in carbon films and hydrophilicity, which were strongly dependent on the deposition process and its parameters, affected the thrombogenicity potential. The hydrophobic CNT materials with high nanoroughness exhibited less hemocompatibility in comparison with the other classes of materials. All the thin film groups exhibited good cytocompatibility, with the surface roughness and surface free energy influencing the viability of cells.
Resumo:
Impaired response to antiplatelet therapy with acetylsalicylic acid (ASA) and clopidogrel (CLO) has been associated with an increased risk of stent thrombosis and ischemic events after coronary stent implantation. We sought to investigate whether patients with a low response (LR) to ASA or CLO are at increased risk for periprocedural and short-term ischemic events after coronary stent implantation.
Resumo:
This study sought to assess the impact of the SYNTAX (Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery) score (SXscore) on clinical outcomes in patients undergoing percutaneous coronary intervention.
Resumo:
Early-generation drug-eluting stents releasing sirolimus (SES) or paclitaxel (PES) are associated with increased risk of very late stent thrombosis occurring >1 year after stent implantation. It is unknown whether the risk of very late stent thrombosis persists with newer-generation everolimus-eluting stents (EES).
Resumo:
A prompt reperfusion with primary percutaneous coronary intervention represents the current gold standard treatment for patients with acute myocardial infarction. In this setting, coronary stents have been shown to improve outcomes compared to plain angioplasty and are routinely used. However, the stent selection among patients with acute myocardial infarction is still a matter of some debate. An increased risk of very late (>1-year) stent thrombosis has been associated with the use of early-generation drug-eluting stents (DES), leading to concerns regarding the long-term safety of these devices. Newer-generation DES were developed with the aim of addressing this safety issue, and were recently investigated in a few randomized studies in patients with acute myocardial infarction. The objective of the present review is to summarize the accumulated evidence, to guide the stent selection in patients with acute myocardial infarction.
Resumo:
Globalisation in coronary stent research calls for harmonization of clinical endpoint definitions and event adjudication. Little has been published about the various processes used for event adjudication or their impact on outcome reporting.
Resumo:
To assess the differential implications of cardiac biomarker type on peri-procedural myocardial infarction (PMI) reporting.
Resumo:
To evaluate the current management, and adherence to recommendations, of patients on oral anticoagulation (OAC) undergoing coronary stent implantation (PCI-S).
Resumo:
We sought to determine a potential interaction between statins and antiplatelet therapy with aspirin and clopidogrel. Previous laboratory studies have shown a possible drug-drug interaction of statins metabolized by cytochrome P450 3A4 and clopidogrel (prodrug metabolized by cytochrome P450 3A4), resulting in an impaired inhibitory effect of clopidogrel on platelet aggregation. However, conclusive prospective data assessing this potentially relevant interaction are lacking. In 73 patients, 23 with previous coronary stent thrombosis (ST) (ST group) and 50 without coronary ST (control group), platelet aggregation was measured 3 times in monthly intervals using light transmission aggregometry (adenosine diphosphate [ADP] and arachidonic acid induction). Measurements were carried out with aspirin monotherapy (100 mg/day), dual antiplatelet therapy with aspirin plus clopidogrel (75 mg/day), and additional treatment of 20 mg/day of atorvastatin or 40 mg/day of pravastatin. ADP (5 and 20 micromol)-induced platelet aggregation was significantly decreased with clopidogrel (p <0.001) but remained stable under additional treatment with atorvastatin or pravastatin in the 2 groups. Patients with previous ST showed a higher ADP-induced aggregation level than control subjects. This difference was not influenced by clopidogrel or statin treatment. In conclusion, patients with previous ST show a higher aggregation level than control subjects independent of statin treatment. Atorvastatin and pravastatin do not interfere with the antiaggregatory effect of aspirin and clopidogrel. In conclusion, drug-drug interaction between dual antiplatelet therapy and atorvastatin or pravastatin seems not to be associated with ST.
Resumo:
We describe the case of 77-year-old woman who underwent five coronary angiographies in 9 months due to in-stent re-stenosis of Cypher-Stents, and who finally required coronary artery bypass grafting surgery. Preoperative investigations revealed a significant internal carotid stenosis, which was due to a fractured and embolized Cypher-Stent.
Resumo:
BACKGROUND: Stent thrombosis is a safety concern associated with use of drug-eluting stents. Little is known about occurrence of stent thrombosis more than 1 year after implantation of such stents. METHODS: Between April, 2002, and Dec, 2005, 8146 patients underwent percutaneous coronary intervention with sirolimus-eluting stents (SES; n=3823) or paclitaxel-eluting stents (PES; n=4323) at two academic hospitals. We assessed data from this group to ascertain the incidence, time course, and correlates of stent thrombosis, and the differences between early (0-30 days) and late (>30 days) stent thrombosis and between SES and PES. FINDINGS: Angiographically documented stent thrombosis occurred in 152 patients (incidence density 1.3 per 100 person-years; cumulative incidence at 3 years 2.9%). Early stent thrombosis was noted in 91 (60%) patients, and late stent thrombosis in 61 (40%) patients. Late stent thrombosis occurred steadily at a constant rate of 0.6% per year up to 3 years after stent implantation. Incidence of early stent thrombosis was similar for SES (1.1%) and PES (1.3%), but late stent thrombosis was more frequent with PES (1.8%) than with SES (1.4%; p=0.031). At the time of stent thrombosis, dual antiplatelet therapy was being taken by 87% (early) and 23% (late) of patients (p<0.0001). Independent predictors of overall stent thrombosis were acute coronary syndrome at presentation (hazard ratio 2.28, 95% CI 1.29-4.03) and diabetes (2.03, 1.07-3.83). INTERPRETATION: Late stent thrombosis was encountered steadily with no evidence of diminution up to 3 years of follow-up. Early and late stent thrombosis were observed with SES and with PES. Acute coronary syndrome at presentation and diabetes were independent predictors of stent thrombosis.