900 resultados para Conventional water treatment


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study examines a matrix of synthetic water samples designed to include conditions that favour brominated disinfection by-product (Br-DBP) formation, in order to provide predictive models suitable for high Br-DBP forming waters such as salinity-impacted waters. Br-DBPs are known to be more toxic than their chlorinated analogues, in general, and their formation may be favoured by routine water treatment practices such as coagulation/flocculation under specific conditions; therefore, circumstances surrounding their formation must be understood. The chosen factors were bromide concentration, mineral alkalinity, bromide to dissolved organic carbon (Br/DOC) ratio and Suwannee River natural organic matter concentration. The relationships between these parameters and DBP formation were evaluated by response surface modelling of data generated using a face-centred central composite experimental design. Predictive models for ten brominated and/or chlorinated DBPs are presented, as well as models for total trihalomethanes (tTHMs) and total dihaloacetonitriles (tDHANs), and bromide substitution factors for the THMs and DHANs classes. The relationships described revealed that increasing alkalinity and increasing Br/DOC ratio were associated with increasing bromination of THMs and DHANs, suggesting that DOC lowering treatment methods that do not also remove bromide such as enhanced coagulation may create optimal conditions for Br-DBP formation in waters in which bromide is present.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coal seam gas production has resulted in the production of large volumes of associated water which contains dissolved salts dominated by sodium chloride and sodium bicarbonate. Ion exchange using synthetic resins has been proposed as a method for desalination of coal seam water to make it suitable for various beneficial reuse options. This study investigated the behaviour of solutions of sodium chloride and sodium bicarbonate with respect to exchange with Lanxess S108H strong acid cation (SAC) resin. Equilibrium isotherms were created for solutions of NaCl and NaHCO3 and an actual sample of coal seam water from the Surat Basin in southern Queensland. The exchange of sodium ions arising from sodium bicarbonate was found to be considerably more favourable than exchange of sodium ions from sodium chloride solutions. This latter behaviour was attributed to the secondary decomposition of bicarbonate species under acidic conditions which resulted in the evolution of carbon dioxide and formation of water. The isotherm profiles could not be satisfactorily fitted by a single isotherm model such as the Langmuir expression. Instead, two Langmuir equations had to be simultaneously applied in order to fit the sections of the isotherm attributable to sodium ion exchange from sodium bicarbonate and sodium chloride. The shape of the isotherm profile was dependent upon the ratio of sodium chloride to sodium bicarbonate in solution and there was a high degree of correlation between simulated and actual coal seam water solutions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reverse osmosis is the dominant technology utilized for desalination of saline water produced during the extraction of coal seam gas. Alternatively, ion exchange is of interest due to potential cost advantages. However, there is limited information regarding the column performance of strong acid cation resin for removal of sodium ions from both model and actual coal seam water samples. In particular, the impact of bed depth, flow rate, and regeneration was not clear. Consequently, this study applied Bed Depth Service Time (BDST) models to reveal that increasing sodium ion concentration and flow rates diminished the time required for breakthrough to occur. The loading of sodium ions on fresh resin was calculated to be ca. 71.1 g Na/kg resin. Difficulties in regeneration of the resin using hydrochloric acid solutions were discovered, with 86% recovery of exchange sites observed. The maximum concentration of sodium ions in the regenerant brine was found to be 47,400 mg/L under the conditions employed. The volume of regenerant waste formed was 6.2% of the total volume of water treated. A coal seam water sample was found to load the resin with only 53.5 g Na/kg resin, which was consistent with not only the co-presence of more favoured ions such as calcium, magnesium, barium and strontium, but also inefficient regeneration of the resin prior to the coal seam water test.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Urban water bodies frequently receive untreated sewage and water levels in such water bodies are maintained by daily inputs of sewage. They function as “variable-zone” anaerobic-aerobic lagoons suffering several macrophyte, biotic and abiotic stresses. We have studied two such lakes in Bangalore (Bellandur-360 ha and Varthur-220 ha) to understand whether such an occurrence could be made beneficial (maintaining water levels as well as treatment). Such hypertrophic water body receives sewage at 180-250mg/L and is discharged at 25-80mg/L COD/BOD in different seasons. In an earlier study we reported macrophyte altering the purification function of the water body. In this paper we studied the impact of phytoplankton dynamics and macrophyte cover on the functions such as organic load removal. Algal community analysis, algal biomass, macrophyte cover, water quality, nutrient status was studied seasonally during 2009-2010. Oxygen deficiency and sometimes anoxia, recorded from surface samples resulted in high quantities of NH4+-N (30-40mg/L) and phosphate (0.5-4mg/L)-characteristics of anoxic hypertrophic urban lakes. The productiveness favoured high phytoplanktonic community characterized by small cells (<10μm; Chlorella sp. - highest numbers). The lake could be clearly demarcated into an initial anaerobic zone (40% area), a facultative zone (20%) and an aerobic zone (40%) based on redox values and GIS/bathymetry. During summer the lake is covered by floating macrophytes converting the lake into an anoxic/anaerobic water pool subduing the water purification function as well as aesthetics. When macrophytes are controlled such sewage fed water bodies can be used for treating urban wastewater while also maintaining water sustainability in these semi-arid ecosystems. This paper reports the community dynamics of phytoplankton, their function and competition with macrophytes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Household-level water treatment and safe storage systems (HWTS) are simple, local, user-friendly, and low cost options to improve drinking water quality at the point of use. However, despite conclusive evidence of the health and economic benefits of HWTS, and promotion efforts in over 50 countries in the past 20 years, implementation outcomes have been slow, reaching only 5-10 million regular users. This study attempts to understand the barriers and drivers affecting HWTS implementation. Using a case study example of a biosand filter program in southern India, system dynamics modelling is shown to be a useful tool to map the inter-relationships of different critical factors and to understand the dissemination dynamics. It is found that the co-existence of expanding quickly and achieving financial sustainability appears to be difficult to achieve under the current program structure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract: Starting in the 1980s, household-level water treatment and safe storage systems (HWTS) have been developed as simple, local, user-friendly, and low cost options to improve drinking water quality at the point of use. However, despite conclusive evidence of the health and economic benefits of HWTS, and promotion efforts in over 50 countries in the past 20 years, implementation outcomes have been slow, reaching only 5-10 million regular users. This study attempts to understand the barriers and drivers affecting HWTS implementation. Although existing literature related to HWTS and innovation diffusion theories proposed ample critical factors and recommendations, there is a lack of holistic and systemic approach to integrate these findings. It is proposed that system dynamics modelling can be a promising tool to map the inter-relationships of different critical factors and to understand the structure of HWTS dissemination process, which may lead to identifying high impact, leveraged mitigation strategies to scale-up HWTS adoption and sustained use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The direct measurement of in situ respiring bacteria using 5-cyano-2,3-ditolyl tetrazolium chloride (CTC) shows that, especially for Gram-negative bacteria, large numbers of viable but non-culturable (VBNC) bacteria are present in finished water from a conventional water treatment plant, and the regrowth of bacteria along distribution networks can be seen rapidly by using this very sensitive technique. The level of bacterial inactivation with chlorine is much less important than has been previously supposed (based on experiments with non-injured laboratory strains of bacteria and classical culture techniques). Threshold values of VBNC bacteria leaving water treatment plants or regrowing along distribution systems have to be determined for better control of coliform regrowth and health- risks associated with the consumption of drinking water.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Stocks Reservoir is situated amidst the Forest of Bowland in the upper reaches of the old river valley of the Hodder. The reservoir was built in 1927 for the Fylde Water Board who primarily supplied water to Blackpool. The objective of this study is to assess the degree and likelihood of fish ingress onto the fish plates at the present and proposed stocking densities. An additional aim is to evaluate the operational implications, and if necessary suggest methods of alleviating the problem. Three spheres of study have been undertaken to achieve these objectives, these being: 1. To selectively stock the reservoir and monitor the angling club catches in order to assess the total population, relating it to fish plate losses and proposed stocking densities. 2. To monitor the fish taken from the fish plates and assess the reasons for their ingress. 3. To study the draw off tower and fish plates, and suggest ways of ameliorating or halting the loss of fish and consequent operational problems.