935 resultados para Controle de pressão de fluxo
Resumo:
Postsurgical complication of hypertension may occur in cardiac patients. To decrease the chances of complication it is necessary to reduce elevated blood pressure as soon as possible. Continuous infusion of vasodilator drugs, such as sodium nitroprusside (Nipride), would quickly lower the blood pressure in most patients. However, each patient has a different sensitivity to infusion of Nipride. The parameters and the time delays of the system are initially unknown. Moreover, the parameters of the transfer function associated with a particular patient are time varying. the objective of the study is to develop a procedure for blood pressure control i the presence of uncertainty of parameters and considerable time delays. So, a methodology was developed multi-model, and for each such model a Preditive Controller can be a priori designed. An adaptive mechanism is then needed for deciding which controller should be dominant for a given plant
Resumo:
Hypertension is a dangerous disease that can cause serious harm to a patient health. In some situations the necessity to control this pressure is even greater, as in surgical procedures and post-surgical patients. To decrease the chances of a complication, it is necessary to reduce blood pressure as soon as possible. Continuous infusion of vasodilators drugs, such as sodium nitroprusside (SNP), rapidly decreased blood pressure in most patients, avoiding major problems. Maintaining the desired blood pressure requires constant monitoring of arterial blood pressure and frequently adjusting the drug infusion rate. Manual control of arterial blood pressure by clinical personnel is very demanding, time consuming and, as a result, sometimes of poor quality. Thus, the aim of this work is the design and implementation of a database of tuned controllers based on patients models, in order to find a suitable PID to be embedded in a Programmable Integrated Circuit (PIC), which has a smaller cost, smaller size and lower power consumption. For best results in controlling the blood pressure and choosing the adequate controller, tuning algorithms, system identification techniques and Smith predictor are used. This work also introduces a monitoring system to assist in detecting anomalies and optimize the process of patient care.
Resumo:
The continuous gas lift method is the main artificial lifting method used in the oil industry for submarine wells, due to its robustness and the large range of flow rate that the well might operate. Nowadays, there is a huge amount of wells producing under this mechanism. This method of elevation has a slow dynamics due to the transients and a correlation between the injected gas rate and the of produced oil rate. Electronics controllers have been used to adjust many parameters of the oil wells and also to improve the efficiency of the gas lift injection system. This paper presents a intelligent control system applied to continuous gas injection in wells, based in production s rules, that has the target of keeping the wells producing during the maximum period of time, in its best operational condition, and doing automatically all necessary adjustments when occurs some disturbance in the system. The author also describes the application of the intelligent control system as a tool to control the flow pressure in the botton of the well (Pwf). In this case, the control system actuates in the surface control valve
Resumo:
FUNDAMENTO: A não adesão ao tratamento tem sido identificada como a causa principal da Pressão Arterial (PA) não controlada, e pode representar um risco maior em idosos. OBJETIVO: O objetivo deste estudo foi avaliar e comparar a taxa de adesão ao tratamento da hipertensão arterial por diferentes métodos, para estimar a taxa de controle da PA, e observar se há uma associação entre controle da pressão arterial e adesão. MÉTODOS: A adesão ao tratamento foi avaliada em pacientes idosos com hipertensão, acompanhados pelo serviço público de saúde, por meio de quatro métodos, incluindo o teste de Morisky-Green (referência), o questionário sobre atitudes referentes à ingestão de medicação (AMI), uma avaliação da adesão por parte do enfermeiro em consultório (AEC), e avaliação domiciliar da adesão (ADA). A ingestão de sal foi estimada pela excreção urinária de sódio de 24 horas. O controle da pressão arterial foi avaliado pelo monitorização ambulatorial da pressão arterial na vigília. RESULTADOS: A concordância entre o teste de Morisky-Green e o AMI (Kappa = 0,27) ou a AEC (Kappa = 0,05) foi pobre. Houve uma concordância moderada entre o teste de Morisky-Green e a ADA. Oitenta por cento tinham a PA controlada, incluindo 42% com efeito do jaleco branco. O grupo com menor excreção de sal relatou evitar o consumo de sal mais vezes (p < 0,001) e também teve maior adesão ao medicamento (p < 0,001) do que o grupo com maior de excreção de sal. CONCLUSÃO: Os testes avaliados não apresentaram boa concordância com o teste de Morisky-Green. A adesão ao tratamento da hipertensão foi baixa; no entanto, houve uma elevada taxa de controle da pressão arterial, quando os sujeitos com o efeito do jaleco branco foram incluídos na análise.
Resumo:
The sanitation companies from Brazil has a great challenge for the XXI century: seek to mitigate the rate of physical waste (water, chemicals and electricity) and financial waste caused by inefficient operating systems drinking water supply, considering that currently we already face, in some cases, the scarcity of water resources. The supply systems are increasingly complex as they seek to minimize waste and at the same time better serve the growing number of users. However, this technological change is to reduce the complexity of the challenges posed by the need to include users with higher quality and efficiency in services. A major challenge for companies of water supplies is to provide a good quality service contemplating reducing expenditure on electricity. In this situation we developed a research by a method that seeks to control the pressure of the distribution systems that do not have the tank in your setup and the water comes out of the well directly to the distribution system. The method of pressure control (intelligent control) uses fuzzy logic to eliminate the waste of electricity and the leaks from the production of pumps that inject directly into the distribution system, which causes waste of energy when the consumption of households is reduced causing the saturation of the distribution system. This study was conducted at Green Club II condominium, located in the city of Parnamirim, state of Rio Grande do Norte, in order to study the pressure behavior of the output of the pump that injects water directly into the distribution system. The study was only possible because of the need we had to find a solution to some leaks in the existing distribution system and the extensions of the respective condominium residences, which sparked interest in developing a job in order to carry out the experiments contained in this research
Resumo:
Em meados da década de 50 iniciou-se o desenvolvimento da citometria de fluxo, tecnologia que permite verificar características físico-químicas de células ou partículas suspensas em meio fluido. Esta tecnologia utiliza anticorpos monoclonais marcados com fluorocromos como ferramenta de investigação em diversas análises e necessita de controles isotípicos para definição da região negativa (background). Estes controles são constituídos por imunoglobulinas de mesmo isotipo e fluorocromo dos anticorpos testes, sendo o isotiocianato de fluoresceína (FITC) o marcador fluorescente mais utilizado na conjugação de anticorpos. Os controles isotípicos têm como função definir a fluorescência inespecífica (células negativas) e as regiões fluorescentes (células positivas). No presente estudo foi selecionado anticorpo monoclonal murino (AcMm) dirigido contra antígeno eritrocitário canino, produzido no Laboratório de Anticorpos Monoclonais do Hemocentro de Botucatu, o qual reage positivamente com hemácias de cães, mas nunca com leucócitos humanos, tendo, portanto, potencial utilidade como controle negativo em citometria de fluxo. A purificação do AcMm da subclasse IgG1 foi feita por cromatografia de afinidade em Proteína-A Sepharose, e o controle da purificação realizado por eletroforese em géis de ágarose e poliacrilamida (SDS-PAGE). A imunoglobulina purificada foi conjugada ao FITC e filtrado em coluna de Sephadex G-25 para separação das proteínas marcadas e não-marcadas. O AcMm conjugado foi testado contra hemácias de cães, e o êxito da conjugação comprovado por testes de fluorescência, sendo a mediana de positividade de 94,70. Frente a leucócitos humanos a mediana de positividade foi 0,03 contra 0,50 dos reagentes comerciais. Os testes estatísticos não-paramétricos de Wilcoxon e correlação de Spearman comprovaram a eficiência e validam o controle isotípico produzido em comparação aos reagentes comerciais testados.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In the Oil industry, oil and gas pipelines are commonly utilized to perform the transportation of production fluids to longer distances. The maintenance of the pipelines passes through the analysis of several tools, in which the most currently used are the pipelines inspection cells, popularly knowing as PIG. Among the variants existing in the market, the instrumented PIG has a significant relevance; acknowledging that through the numerous sensors existing in the equipment, it can detect faults or potential failure along the inspected line. Despite its versatility, the instrumented PIG suffers from speed variations, impairing the reading of sensors embedded in it. Considering that PIG moves depending on the speed of the production fluid, a way to control his speed is to control the flow of the fluid through the pressure control, reducing the flow rate of the produced flow, resulting in reduction of overall production the fluid in the ducts own or with the use of a restrictive element (valve) installed on it. The characteristic of the flow rate/pressure drop from restrictive elements of the orifice plate is deducted usually from the ideal energy equation (Bernoulli’s equation) and later, the losses are corrected normally through experimental tests. Thus, with the objective of controlling the fluids flow passing through the PIG, a valve shutter actuated by solenoid has been developed. This configuration allows an ease control and stabilization of the flow adjustment, with a consequent response in the pressure drops between upstream and downstream of the restriction. It was assembled a test bench for better definition of flow coefficients; composed by a duct with intern diameter of four inches, one set of shutters arranged in a plate and pressure gauges for checking the pressure drop in the test. The line was pressurized and based on the pressure drop it was possible to draw a curve able to characterize the flow coefficient of the control valve prototype and simulate in mockup the functioning, resulting in PIG speed reduction of approximately 68%.
Resumo:
As doenças cardiovasculares permanecem como a principal causa de morte no mundo, e têm a hipertensão arterial sistêmica (HAS) e o diabetes mellitus tipo 2 (DM2) como uns dos seus principais fatores de risco. Sabidamente, a HAS e o DM2 são doenças frequentemente associadas. A escolha dos fármacos anti-hipertensivos a serem utilizados no tratamento de pacientes hipertensos diabéticos tem como objetivo o controle da pressão arterial, a redução da morbimortalidade das complicações macro e microvasculares. Alterações na função endotelial precedem as alterações morfológicas do vaso e contribuem para o desenvolvimento das complicações macrovasculares. O objetivo deste estudo foi avaliar a associação de alterações vasculares funcionais com o uso de losartana ou anlodipino em pacientes hipertensos e diabéticos tipo 2. Foi realizado um estudo transversal com coleta de dados prospectiva. Os pacientes incluídos foram randomizados e divididos em dois grupos, sendo avaliados na sexta semana da utilização de losartana 100 mg/dia ou anlodipino 5 mg/dia, com aferição da PA, realização de monitorização ambulatorial da pressão arterial e testes para avaliação de parâmetros vasculares como tonometria de aplanação, velocidade de onda de pulso (VOP) e dilatação mediada por fluxo (DMF) da artéria braquial. Foram incluídos 42 pacientes, 21 em cada grupo. A distribuição da amostra demonstrou uma predominância do sexo feminino (71%) nos dois grupos e uma semelhança na idade média dos pacientes (54,06,9 anos, no grupo losartana e 54,94,5 anos, no grupo anlodipino). A média dos valores de pressão arterial na sexta semana foram 15319/909 mmHg no grupo losartana e 14514/848 mmHg no grupo anlodipino, não havendo diferença estatística entre os grupos. O augmentation index (AIx; 309% vs. 368%, p=0,025), assim como a augmentation pressure (166 mmHg vs. 208 mmHg, p=0,045) foram menores no grupo anlodipino do que no grupo losartana. Os valores obtidos para VOP e DMF foram semelhantes nos dois grupos. Em pacientes hipertensos e diabéticos tipo 2, o tratamento com anlodipino em dose média comparado com losartana em dose máxima associou-se a menores níveis de pressão arterial casual. Menores valores de AIx foram observados no grupo anlodipino, com um padrão de reflexão da onda de pulso mais favorável neste grupo. Os valores da VOP e DMF encontrados foram semelhantes nos dois grupos podendo sugerir influências da losartana sobre os parâmetros vasculares independentes do efeito pressórico.
Resumo:
The present work presents an algorithm proposal, which aims for controlling and improving idle time to be applied in oil production wells equipped with beam pump. The algorithm was totally designed based on existing papers and data acquired from two Potiguar Basin pilot wells. Oil engineering concepts such as submergence, pump off, Basic Sediments and Water (BSW), Inflow Performance Relationship (IPR), reservo ir pressure, inflow pressure, among others, were included into the algorithm through a mathematical treatment developed from a typical well and then extended to the general cases. The optimization will increase the well production potential maximum utilization having the smallest number of pumping unit cycles directly reflecting on operational cost and electricity consumption reduction
Resumo:
In asthmatic, the lung hyperinflation leaves the inspiratory muscle at a suboptimal position in length-tension relationship, reducing the capacity of to generate tension. The increase in transversal section area of the inspiratory muscles could reverse or delay the deterioration of inspiratory muscle function. Objective: To evaluate the evidence for the efficacy of inspiratory muscle training (IMT) with an external resistive device in patients with asthma. Methods: A systematic review with meta-analysis was carried out. The sources researched were the Cochrane Airways Group Specialised Register of trials, Cochrane Central Register of Controlled Trials (The Cochrane Library Issue 11 of 12, 2012), MEDLINE, EMBASE, PsycINFO, CINAHL, AMED, ClinicalTrials.gov and reference lists of articles. All databases were searched from their inception up to November 2012 and there was no restriction on the language of publication. Randomised controlled trials that involved the use of an external inspiratory muscle training device versus a control (sham or no inspiratory training device) were considered for inclusion. Two reviewers independently selected articles for inclusion, evaluated risk of bias in studies and extracted data. Results: A total of five studies involving 113 asthmatic patients were included. Three clinical trials were produced by the same group. The included studies showed a significant increase in maximal inspiratory pressure (MD 13.34 cmH2O, 95% CI 4.70 to 21.98), although the confidence intervals were wide. There was no statistically significant difference between the IMT group and the control group for maximal expiratory pressure, peak expiratory flow rate, forced expiratory volume in one second, forced vital capacity, sensation of dyspnea and use of beta2-agonist. There were no studies describing exacerbation events that required a course of oral and inhaled corticosteroids or emergency department visits, inspiratory muscle endurance, hospital admissions and days of work or school. Conclusions: There is no conclusive evidence in this review to support or refute inspiratory muscle training for asthma, once the evidence was limited by the small number of studies included, number of participants in them together with the risk of bias. More well conducted randomized controlled trials are needed, such trials should investigate respiratory muscle strength, exacerbation rate, lung function, symptoms, hospital admissions, use of medications and days off work or school. IMT should also be assessed in the context of more severe asthma
Resumo:
JUSTIFICATIVA E OBJETIVOS: Estudos introduziram novo método para avaliação da pré-carga, baseado na análise da variação da pressão sistólica (VPS) durante ventilação artificial. O objetivo desta pesquisa é avaliar se a VPS e sua derivada delta down (ddown) são indicadoras precoces de hipovolemia e guias de reposição volêmica com solução hiperosmótica e hiperoncótica. MÉTODO: Doze cães foram submetidos a sangramentos parciais de 5% da volemia até se atingir 20% da volemia (14 ml.kg-1). Antes (controle) e após cada sangramento foram realizadas análises hemodinâmicas, respiratórias e sangüíneas. Após, os cães foram submetidos à reposição com solução de NaCl a 7,5% em dextran 70 a 3,75% (SHD) (4 ml.kg-1) e novas análises dos atributos estudados foram realizadas aos 5 e 30 minutos após a reposição. RESULTADOS: A pressão arterial média diminuiu durante o sangramento e aumentou após a reposição, sem retornar aos valores do controle. As pressões da artéria pulmonar e do átrio direito (PAD) diminuíram antes e aumentaram após a reposição para valores semelhantes aos do controle. A pressão da artéria pulmonar ocluída (PAPO) diminuiu após o primeiro sangramento e manteve-se em valores abaixo aos do controle, mesmo após a reposição. O índice cardíaco não se alterou, mas aumentou após a reposição, para valores superiores aos do controle. O índice sistólico (IS) diminuiu antes e aumentou após a reposição, em níveis superiores aos do controle. Os índices de resistência vascular sistêmica (IRVS) e pulmonar (IRVP) não se alteraram antes, mas diminuíram após a reposição, com o IRVS em níveis inferiores aos do controle, e o IRVP em níveis semelhantes aos do controle. Os índices de trabalho sistólico dos ventrículos direito (ITSVD) e esquerdo (ITSVE) diminuíram durante o sangramento, mas aumentaram após a reposição, com o ITSVD em níveis superiores aos do controle e o ITSVE em níveis semelhantes aos do controle. A VPS e ddown aumentaram progressivamente durante o sangramento e diminuíram após a reposição, mas mantendo-se em valores superiores aos do controle. As maiores correlações de VPS e ddown foram com IS, PAPO, PAD e ITSVE. CONCLUSÕES: No cão, nas condições empregadas, a VPS e sua derivada ddown são indicadoras precoces de hipovolemia e guias sensíveis de reposição volêmica com SHD.
Resumo:
OBJETIVO: Avaliar as alterações hemodinâmicas e sistêmicas decorrentes de isquemia e reperfusão (I/R) esplâncnica em ratos. MÉTODOS: Vinte ratos foram divididos em dois grupos: grupo controle: os animais foram submetidos à cirurgia, mas não a I/R e foram tratados com solução fisiológica (5 ml/kg/h) por 150 minutos; grupo I/R: os animais foram submetidos à administração contínua de solução fisiológica e à oclusão do tronco celíaco, artéria mesentérica superior e artéria mesentérica inferior por 30 minutos, seguidos por 120 minutos de reperfusão. Avaliou-se a pressão arterial média, pressão venosa, fluxo sangüíneo na aorta e na artéria mesentérica superior, freqüência cardíaca, temperatura esofágica e hematócrito. RESULTADOS: Durante a reperfusão, no grupo I/R, houve uma diminuição progressiva da pressão arterial média, fluxo sangüíneo na aorta e artéria mesentérica superior, freqüência cardíaca e temperatura esofágica; pressão venosa e hematócrito não sofreram alteração. CONCLUSÃO: O modelo de isquemia provocado por oclusão da artéria mesentérica superior, artéria mesentérica inferior e tronco celíaco por 30 minutos seguidos por 120 minutos de reperfusão provoca alterações sistêmicas evidenciadas por hipotensão, diminuição do fluxo sangüíneo mesentérico, da freqüência cardíaca e da temperatura esofágica.