930 resultados para Contaminant removal effectiveness
Resumo:
The ventilation efficiency concept is an attempt to quantify a parameter that can easily distinguish the different options for air diffusion in the building spaces. Thirteen strategies of air diffusion were measured in a test chamber through the application of the tracer gas method, with the objective to validate the calculation by Computational fluid dynamics (CFD). Were compared the Air Change Efficiency (ACE) and the Contaminant Removal Effectiveness (CRE), the two indicators most internationally accepted. The main results from this work shows that the values of the numerical simulations are in good agreement with experimental measurements and also, that the solutions to be adopted for maximizing the ventilation efficiency should be the schemes that operate with low speeds of supply air and small differences between supply air temperature and the room temperature.
Resumo:
Indoor Air 2016 - The 14th International Conference Indoor Air Quality and Climate
Resumo:
Buildings account for 40% of total energy consumption in the European Union. The reduction of energy consumption in the buildings sector constitute an important measure needed to reduce the Union's energy dependency and greenhouse gas emissions. The Portuguese legislation incorporate this principles in order to regulate the energy performance of buildings. This energy performance should be accompanied by good conditions for the occupants of the buildings. According to EN 15251 (2007) the four factors that affect the occupant comfort in the buildings are: Indoor Air Quality (IAQ), thermal comfort, acoustics and lighting. Ventilation directly affects all except the lighting, so it is crucial to understand the performance of it. The ventilation efficiency concept therefore earn significance, because it is an attempt to quantify a parameter that can easily distinguish the different options for air diffusion in the spaces. The two indicators most internationally accepted are the Air Change Efficiency (ACE) and the Contaminant Removal Effectiveness (CRE). Nowadays with the developed of the Computational Fluid Dynamics (CFD) the behaviour of ventilation can be more easily predicted. Thirteen strategies of air diffusion were measured in a test chamber through the application of the tracer gas method, with the objective to validate the calculation by the MicroFlo module of the IES-VE software for this two indicators. The main conclusions from this work were: that the values of the numerical simulations are in agreement with experimental measurements; the value of the CRE is more dependent of the position of the contamination source, that the strategy used for the air diffusion; the ACE indicator is more appropriate for quantifying the quality of the air diffusion; the solutions to be adopted, to maximize the ventilation efficiency should be, the schemes that operate with low speeds of supply air and small differences between supply air temperature and the room temperature.
Resumo:
Many factors affect the airflow patterns, thermal comfort, contaminant removal efficiency and indoor air quality at individual workstations in office buildings. In this study, four ventilation systems were used in a test chamber designed to represent an area of a typical office building floor and reproduce the real characteristics of a modern office space. Measurements of particle concentration and thermal parameters (temperature and velocity) were carried out for each of the following types of ventilation systems: (a) conventional air distribution system with ceiling supply and return; (b) conventional air distribution system with ceiling supply and return near the floor; (c) underfloor air distribution system; and (d) split system. The measurements aimed to analyse the particle removal efficiency in the breathing zone and the impact of particle concentration on an individual at the workstation. The efficiency of the ventilation system was analysed by measuring particle size and concentration, ventilation effectiveness and the indoor/outdoor ratio. Each ventilation system showed different airflow patterns and the efficiency of each ventilation system in the removal of the particles in the breathing zone showed no correlation with particle size and the various methods of analyses used. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Electrokinetics has emerged as a potential technique for in situ soil remediation and especially unique because of the ability to work in low permeability soil. In electrokinetic remediation, non-polar contaminants like most organic compounds are transported primarily by electroosmosis, thus the process is effective only if the contaminants are soluble in pore fluid. Therefore, enhancement is needed to improve mobility of these hydrophobic compounds, which tend to adsorb strongly to the soil. On the other hand, as a novel and rapidly growing science, the applications of ultrasound in environmental technology hold a promising future. Compared to conventional methods, ultrasonication can bring several benefits such as environmental friendliness (no toxic chemical are used or produced), low cost, and compact instrumentation. It also can be applied onsite. Ultrasonic energy applied into contaminated soils can increase desorption and mobilization of contaminants and porosity and permeability of soil through developing of cavitation. The research investigated the coupling effect of the combination of these two techniques, electrokinetics and ultrasonication, in persistent organic pollutant removal from contaminated low permeability clayey soil (with kaolin as a model medium). The preliminary study checked feasibility of ultrasonic treatment of kaolin highly contaminated by persistent organic pollutants (POPs). The laboratory experiments were conducted in various conditions (moisture, frequency, power, duration time, initial concentration) to examine the effects of these parameters on the treatment process. Experimental results showed that ultrasonication has a potential to remove POPs, although the removal efficiencies were not high with short duration time. The study also suggested intermittent ultrasonication over longer time as an effective means to increase the removal efficiencies. Then, experiments were conducted to compare the performances among electrokinetic process alone and electrokinetic processes combined with surfactant addition and mainly with ultrasonication, in designed cylinders (with filtercloth separating central part and electrolyte parts) and in open pans. Combined electrokinetic and ultrasonic treatment did prove positive coupling effect compared to each single process alone, though the level of enhancement is not very significant. The assistance of ultrasound in electrokinetic remediation can help reduce POPs from clayey soil by improving the mobility of hydrophobic organic compounds and degrading these contaminants through pyrolysis and oxidation. Ultrasonication also sustains higher current and increases electroosmotic flow. Initial contaminant concentration is an essential input parameter that can affect the removal effectiveness.
Resumo:
This paper presents the results of a research on direct drinking water treatment through an ultrafiltration pilot plant unit using spiral-wound membranes (3500 MWCO). The source of water is the Guarapiranga Reservoir, an eutrophicated water body located in the metropolitan region of Sao Paulo, Brazil. The data were collected during a period of almost 3400 h, from August 2005 to January 2006. The main objective of the study was to evaluate the membrane production capacity and contaminant removal efficiency. It was verified that the system was able to produce a high quality permeate with a flow close to the specified by the membrane manufacturer. The average permeate flow was 19.7 L.h(-1).m(-2), at 467 kPa and 25 degrees C, with a global water recovery of almost 85%. The removal efficiencies for TOC, UV light absorption, and turbidity were 85%, 56%, and 95%, respectively. The results provide substantial evidence of the technical feasibility of spiral-wound UF membranes for direct drinking water treatment from euthrophicated sources, as an alternative for conventional drinking water treatment systems.
Resumo:
The thesis deals with a benchmark study of dissolved and sedimentary sulphur compounds which play prominent roles in the prevailing redox conditions in the selected sites of Cochin estuarine system. Sulphur and its analogues play prominent roles in estuarine biochemical processes. A complete knowledge on the sulphur involvement in these processes is restricted due to the lacking of data on the organic sulphur compounds. Sulphate and sulphide in surface and bottom water and Sulphate, acid volatile sulphide and total sulphur in sediments were studied and correlated to know their interrelations in determining the redox condition of the environment. It also characterises the sediments of the sites on the basis of total organic carbon: total sulphur ratio. The study had attempted to decrease the concentration levels of sulphur in the sedimentary environment by the application of a remedial measure. Knowledge of sulphur uptake by plants from prior literatures has prompted to use phytoremediation for decreasing the sulphur concentration. Phytoremediation is an emerging technology that uses plants to clean up or remediate contaminated soil, sludges, sediments, and ground water through contaminant removal, degradation or containment. The plant selected was wheat grass since earlier studies have shown that wheat grass is effective in remediating pollutants particularly trace metals. So reduction in the concentration of selected trace metals was also focussed.
Resumo:
Multiple regression analysis is a statistical technique which allows to predict a dependent variable from m ore than one independent variable and also to determine influential independent variables. Using experimental data, in this study the multiple regression analysis is applied to predict the room mean velocity and determine the most influencing parameters on the velocity. More than 120 experiments for four different heat source locations were carried out in a test chamber with a high level wall mounted air supply terminal at air change rates 3-6 ach. The influence of the environmental parameters such as supply air momentum, room heat load, Archimedes number and local temperature ratio, were examined by two methods: a simple regression analysis incorporated into scatter matrix plots and multiple stepwise regression analysis. It is concluded that, when a heat source is located along the jet centre line, the supply momentum mainly influences the room mean velocity regardless of the plume strength. However, when the heat source is located outside the jet region, the local temperature ratio (the inverse of the local heat removal effectiveness) is a major influencing parameter.
Resumo:
In this paper, the global market potential of solar thermal, photovoltaic (PV) and combined photovoltaic/thermal (PV/T) technologies in current time and near future was discussed. The concept of the PV/T and the theory behind the PV/T operation were briefly introduced, and standards for evaluating technical, economic and environmental performance of the PV/T systems were addressed. A comprehensive literature review into R&D works and practical application of the PV/T technology was illustrated and the review results were critically analysed in terms of PV/T type and research methodology used. The major features, current status, research focuses and existing difficulties/barriers related to the various types of PV/T were identified. The research methods, including theoretical analyses and computer simulation, experimental and combined experimental/theoretical investigation, demonstration and feasibility study, as well as economic and environmental analyses, applied into the PV/T technology were individually discussed, and the achievement and problems remaining in each research method category were described. Finally, opportunities for further work to carry on PV/T study were identified. The review research indicated that air/water-based PV/T systems are the commonly used technologies but their thermal removal effectiveness is lower. Refrigerant/heat-pipe-based PV/Ts, although still in research/laboratory stage, could achieve much higher solar conversion efficiencies over the air/water-based systems. However, these systems were found a few technical challenges in practice which require further resolutions. The review research suggested that further works could be undertaken to (1) develop new feasible, economic and energy efficient PV/T systems; (2) optimise the structural/geometrical configurations of the existing PV/T systems; (3) study long term dynamic performance of the PV/T systems; (4) demonstrate the PV/T systems in real buildings and conduct the feasibility study; and (5) carry on advanced economic and environmental analyses. This review research helps finding the questions remaining in PV/T technology, identify new research topics/directions to further improve the performance of the PV/T, remove the barriers in PV/T practical application, establish the standards/regulations related to PV/T design and installation, and promote its market penetration throughout the world.
Resumo:
Objectives: The objective of this study was to evaluate the accuracy and reproducibility of three complete denture biofilm indices (Prosthesis Hygiene Index; Jeganathan et al. Index; Budtz-J circle divide rgensen Index) by means of a computerised comparison method. Background: Clinical studies into denture hygiene have employed a large number of biofilm indices among their outcome variables. However, the knowledge about the validity of these indices is still scarce. Materials and methods: Sixty-two complete denture wearers were selected. The internal surfaces of the upper complete dentures were stained (5% erythrosine) and photographed. The slides were projected on paper, and the biofilm indices were applied over the photos by means of a scoring method. For the computerised method, the areas (total and biofilm-covered) were measured by dedicated software (Image Tool). In addition, to compare the results of the computerised method and Prosthetic Hygiene Index, a new scoring scale (including four and five graded) was introduced. For the Jeganathan et al. and Budtz-J circle divide rgensen indices, the original scales were used. Values for each index were compared with the computerised method by the Friedman test. Their reproducibility was measured by means of weighed kappa. Significance for both tests was set at 0.05. Results: The indices tested provided similar mean measures but they tended to overestimate biofilm coverage when compared with the computerised method (p < 0.001). Agreement between the Prosthesis Hygiene Index and the computerised method was not significant, regardless of the scale used. Jeghanathan et al. Index showed weak agreement, and consistent results were found for Budtz-Jorgensen Index (kappa = 0.19 and 0.39 respectively). Conclusion: Assessment of accuracy for the biofilm indices showed instrument bias that was similar among the tested methods. Weak inter-instrument reproducibility was found for the indices, except for the Budtz-J circle divide rgensen Index. This should be the method of choice for clinical studies when more sophisticated approaches are not possible.
Resumo:
An exploratory investigation was conducted on the effects of application of ozone on the removal of organic and inorganic contaminants and the reduction of settleable solids in urban lake sediments. Homogenized sediment samples were treated in a batch reactor with an external recirculation loop and ozone feed from a Venturi injector. The ozone generating system was fed with ambient air with small footprint and operational simplicity. Ozone mass application (g/h) and contact time (min) were varied over wide ranges during testing. The effects of the ozone mass applied per unit time and the contact time on contaminant removal efficiencies were analyzed and a trade-off between the costs of ozonation and of solids treatment and disposal was proposed. The minimum ozone mass application required for total contaminant removal apparently depended on the type of organic contaminant present. An apparent influence of inorganic contaminant speciation on the removal efficiency was found and discussed.
Resumo:
Oil spills cause serious damage to the cost life and environments. Those impacts affect ecologic and socio-economic resources (like fishing and tourism). Within this background, response actions have two main objectives: the contaminant removal, with the less additional impacts, and enhance environment restoration in order to make this process complete in the shortest time possible. The present work proposes to contribute for the emergency environmental management in cases of oil spills by systematization of relevant information for oil spill environmental sensitivity maps. The next stage was to insert all these data on a geographic database, which allows data access by web. Beside that, this work aimed to recommend suitable clean-up techniques for the ecosystems located on the study area, composed by the municipalities: Praia Grande, Mongaguá, Itanhaém and Peruíbe, belonging to Baixada Santista and Iguape, Cananéia and Ilha Comprida, south cost of São Paulo state. This area is situated between two important Brazilian ports: Santos and Paranaguá, and that make it under considerable accident risks. The results were all data inserted on the geodatabase and available to user recover the information by web consulting. With that, this work wishes to contribute to individual emergencial planning of the region.
Resumo:
This in vitro study aimed to assess the speed and caries removal effectiveness of four different new and conventional dentine excavation methods. Eighty deciduous molars were assigned to four groups. Teeth were sectioned longitudinally through the lesion centre. Images of one half per tooth were captured by light microscope and confocal laser scanning microscopy (CLSM) to assess the caries extension. The halves were then reassembled and caries removed using round carbide bur (group 1), Er:YAG laser (group 2), hand excavator (group 3) and a polymer bur (group 4). The time needed for the whole excavation in each tooth was registered. After excavation, the halves were photographed by light microscope. Caries extension obtained from CLSM images were superimposed on the post-excavation images, allowing comparison between caries extension and removal. The regions where caries and preparation limits coincided, as well as the areas of over- and underpreparation, were measured. Steel bur was the fastest method, followed by the polymer bur, hand excavator and laser. Steel bur exhibited also the largest overpreparation area, followed by laser, hand excavator and polymer bur. The largest underpreparation area was found using polymer bur, followed by laser, hand excavator and steel bur. Hand excavator presented the longest coincidence line, followed by polymer and steel burs and laser. Overall, hand excavator seemed to be the most suitable method for carious dentine excavation in deciduous teeth, combining good excavation time with effective caries removal.
Resumo:
A new method has recently been proposed by us for accurate measurement of the solar cell temperature in any operational regime, in particular, at a maximum power point (MPP) of the I-V curve (T-p-n(MPP)). For this, fast switching of a cell from MPP to open circuit (OC) regime is carried out and open circuit voltage V-oc is measured immediately (within about 1 millisecond), so that this value becomes to be an indicator of T-p-n(MPP). In the present work, we have considered a practical case, when a solar cell is heated not only by absorption of light incident upon its surface (called "photoactive" absorption of power), but also by heat transferred from structural elements surrounding the cell and heated by absorption of direct or diffused sunlight ("non-photoactive" absorption of power with respect to a solar cell). This process takes place in any concentrator module with non-ideal concentrators. Low overheating temperature of the p-n junction (or p-n junctions in a multijunction cell) is a cumulative parameter characterizing the quality of a solar module by the factor of heat removal effectiveness and, at the same time, by the factor of low "non-photoactive" losses.
Resumo:
Wetlands are extremely valuable natural features that have decreased significantly in number over time in Illinois and the United States ... Their important functions include flood protection, water conservation in times of drought, groundwater recharge, improvement of water quality through sediment reduction and contaminant removal, and providing habitat for native animals and plants, including many sensitive and state-listed threatened and endangered species ... Due to a federal "no net loss" policy on wetlands adopted through executive order by President George H. Bush in 1990, as well as a prevailing heightened interest in conservation in general, there is currently considerable interest in the restoration and creation of wetlands. Both Section-404 of the Clean Water Act of 1972 and the Swampbuster Provision of the Food Securities Act of 1985 require compensation or mitigation for the loss of wetlands. A number of federal and state programs such as Section 319 of the Clean Water Act and the Conservation Reserve Program within the Natural Resources Conservation Service (NRCS) encourage wetland restoration and creation. In addition, various conservation organizations, such as The Nature Conservancy and Ducks Unlimited are very active in wetland restoration. Despite wetland restoration efforts and the national goal of no net loss, wetlands and wetland functions continue to be lost due to degradation of existing wetlands ... Unfortunately, no reliable information exists on the quality of existing wetlands or on trends in wetland quality over time ... The functional quality of existing wetlands is likely decreasing in many areas due to the combined effects of habitat fragmentation, alteration of hydrology, invasive species, and continued input of nutrients and pollutants. Furthermore, it is still debatable whether created or restored wetlands can adequately replace the suite of ecological functions provided by natural wetlands ... and the failure of many wetland compensation projects contributes to a continued national net loss of wetland functions ... The need for post-construction site monitoring and assessment of created and restored wetlands to evaluate functional success is widely recognized. ... At this time, there is little agreement on how to assess the success on quality of wetland restorations or creations.