42 resultados para Conservante
Resumo:
Invokaatio: D.O.M.A.
Resumo:
Schinus terebinthifolius Raddi is used in the treatment of skin and mucosal injuries, infections of respiratory, digestive and genitourinary systems. Currently one of the biggest problems faced for the industry of phytopharmaceuticals with regard to the quality of raw materials is the microbial contamination. The aim this study was to evaluate the antimicrobial action of the hidroalcoholic extract of aroeira, beyond testing the effectiveness of the preservative system in hidrogel to the base of this extract. The extracts were prepared by maceration in the ratio of 1:10 of solvent plant/with alcohol 40%. The methods for microbial count were pour plate and test for specific microorganisms, analyzing in third copy each one of the samples. The antimicrobial activity of aroeira extracts was performed using an agar diffusion method, using strains of S. aureus, P. aeruginosa, E. coli, B. subtilis, C. albicans, C. tropicalis, C. krusei, C. guilliermondii, T. rubrum, M. gypseum, A. flavus and A. niger. The formula with aroeira was evaluated by the challenge test. This method consisted of artificial contamination the sample with separate inóculos of A. niger, C. albicans, E. coli e S. aureus aeruginosa and determinations of survivors for the method of counting for pour plate , during times 0, 24h, 48h, 7 days, 14 days, 21 days and 28 days. How much to the results, one verified that the extract of aroeira in the 13,5 concentration mg/mL presented antimicrobial activity for cepas of E. coli, B. subtilis, P. aeruginosa e S. aureus, producing inhibition zone, on average with 13 mm of diameter. However it did not present no fungi activity. The formula with aroeira containig both methylparaben and propylparaben showed a good efficacy in challenge test front to strains of A. niger, C. albicans, E. coli, S. aureus. The A criteria of European Pharmacopoeia, adopted in this work, was verified that this product revealed the good preservative efficacy for the challenge test, time interval of the 28 days. However, it is interesting to extend this study, in order to carry through the sped up stability and the test of shelf, to establish the validity of this formularization
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Ciências Farmacêuticas - FCFAR
Resumo:
Com o objetivo de acompanhar a estabilidade físico-química e microbiológica da carne mecanicamente separada (CMS) de diferentes origens e estocada durante 99 dias a -18 °C, foi realizada prévia mistura de conservante (nitrito de sódio) e antioxidante (eritorbato de sódio) em CMS obtida de duas linhagens de aves: galinhas matrizes de corte e galinhas poedeiras comerciais brancas. Na CMS de cada linhagem foram realizados três diferentes tratamentos: 1) controle (sem aditivos); 2) adição de 150 ppm de nitrito; e 3) adição de 150 ppm de nitrito e 500 ppm de eritorbato. Os resultados encontrados demonstraram que a adição de nitrito isoladamente não impediu a oxidação lipídica, avaliada através do índice de TBARS, nem a alteração na cor, avaliada em colorímetro. Por outro lado, a adição de nitrito juntamente com eritorbato foi efetiva na redução dos problemas de oxidação lipídica na CMS de galinhas matrizes, e em menor grau, na CMS de poedeiras. A adição de nitrito e eritorbato na CMS também melhorou a preservação da cor vermelha desejável (a*) ao longo do tempo. A avaliação da estabilidade microbiológica da CMS, realizada no primeiro e último dia de estocagem congelada, para microrganismos mesófilos, Escherichia coli, Staphylococcus aureus, Clostridium perfringens e Pseudomonas spp., e quinzenalmente para microrganismos psicrotróficos, indicou que não houve uma variação significativa nas contagens em função do tratamento utilizado (diferentes aditivos adicionados). Não foi detectada Salmonella spp. em nenhuma das amostras analisadas. Em função da melhoria da estabilidade oxidativa, recomenda-se a adição de nitrito (150 ppm) e eritorbato (500 ppm) em CMS de galinhas matrizes a ser estocada congelada por um período prolongado.
Resumo:
O consumo de pizzas prontas aumentou nos últimos anos dado à praticidade do produto e ao baixo custo, sabor agradável e valor nutritivo. Porém, esse produto sofre intensa manipulação durante o seu processamento, contribuindo para sua contaminação, diminuindo a qualidade e aumentando os riscos de doenças veiculadas por esse alimento. Aliado à necessidade de produtos práticos e convenientes, o consumidor demanda alimentos cada vez mais seguros, despertando o interesse pelo uso de conservantes naturais. Dentre eles, o óleo essencial de orégano apresenta ação antimicrobiana, sendo essa especiaria utilizada na culinária de vários países. O objetivo deste trabalho foi o desenvolvimento de filme de base celulósica, incorporado com óleo essencial de orégano para conservação de pizza pronta refrigerada. Esse óleo incorporado ao filme nas concentrações de 25 e 50% p/p apresentou efeito inibitório in vitro para Penicillium spp. e Staphylococcus aureus. Quando aplicado em pizza observou-se diminuição dos compostos ρ-cimeno e γ-terpineno e consequente aumento da concentração de timol e carvacrol, mas provavelmente em quantidade insuficiente para o efeito inibitório dos microrganismos. Com relação à resistência mecânica, os filmes incorporados com 25 e 50% de óleo tiveram sua resistência diminuída, tendo a tenacidade do filme de 50% aumentada com relação ao controle (0%). O uso de filme incorporado com o óleo de orégano desperta grande interesse na aplicação em pizzas, uma vez que o orégano já é um ingrediente do produto, portanto não compromete o sabor e odor da pizza.
Resumo:
A exposição a formaldeído é reconhecidamente um dos mais importantes factores de risco presente nos laboratórios hospitalares de anatomia patológica. Neste contexto ocupacional, o formaldeído é utilizado em solução, designada comummente por formol. Trata-se de uma solução comercial de formaldeído, normalmente diluída a 10%, sendo pouco onerosa e, por esse motivo, a eleita para os trabalhos de rotina em anatomia patológica. A solução é utilizada como fixador e conservante do material biológico, pelo que as peças anatómicas a serem processadas são previamente impregnadas. No que concerne aos efeitos cancerígenos, a primeira avaliação efectuada pela International Agency for Research on Cancer data de 1981, actualizada em 1982, 1987, 1995 e 2004, considerando-o como um agente cancerígeno do grupo 2A (provavelmente carcinogénico). No entanto, a mais recente avaliação, em 2006, considera o formaldeído no Grupo 1 (agente carcinogénico) com base na evidência de que a exposição a este agente é susceptível de causar cancro nasofaríngeo em humanos. Constituiu objectivo principal do estudo desenvolvido caracterizar a exposição profissional a formaldeído em laboratórios hospitalares de anatomia patológica. O estudo incidiu sobre 10 laboratórios hospitalares de anatomia patológica situados em Portugal Continental. Foi avaliada a exposição dos trabalhadores considerando três grupos profissionais (Técnicos de Anatomia Patológica, Médicos Anatomo-Patologistas e Auxiliares) por comparação com dois referenciais de exposição (VLE-CM e VLE-MP) e, ainda, considerados os valores de concentração máxima em 83 actividades desenvolvidas nos laboratórios pertencentes à amostra. Foram aplicados simultaneamente dois métodos distintos de avaliação ambiental: um dos métodos (Método 1) fez uso de um equipamento de leitura directa com o princípio de medição por Photo Ionization Detection, com uma lâmpada de 11,7 eV, realizando-se, simultaneamente, o registo da actividade de trabalho − foram assim obtidos dados para o referencial de exposição da concentração máxima (CM); o outro método (Método 2) traduziu-se na aplicação do método NIOSH 2541, implicando o uso de bombas de amostragem eléctricas de baixo caudal e posterior processamento analítico das amostras por cromatografia gasosa − este método, por sua vez, facultou dados para o referencial de exposição da concentração média ponderada (CMP). A aplicação simultânea dos dois métodos de avaliação ambiental resultou na obtenção de resultados distintos, mas não contraditórios, no que concerne à avaliação da exposição profissional a formaldeído. Para as actividades estudadas (n=83) verificou-se que cerca de 93% dos valores são superiores ao valor limite de exposição definido para a concentração máxima (VLE-CM=0,3 ppm). O “exame macroscópico” foi a actividade mais estudada e onde se verificou a maior prevalência de resultados superiores ao valor limite (92,8%). O valor médio mais elevado da concentração máxima (2,04 ppm) verificou-se no grupo de exposição dos Técnicos de Anatomia Oatológica. No entanto, a maior amplitude de resultados observou-se no grupo dos Médicos Anatomo-Patologistas (0,21 ppm a 5,02 ppm). No que respeita ao referencial da Concentração Média Ponderada, todos os valores obtidos nos 10 laboratórios estudados para os três grupos de exposição foram inferiores ao valor limite de exposição definido pela Occupational Safety and Health Administration (TLV-TWA=0,75 ppm). Dado não se perspectivar a curto prazo a eliminação do formaldeído, devido ao grande número de actividades que envolvem ainda a utilização da sua solução comercial (formol), pode concluir-se que a exposição a este agente neste contexto ocupacional específico é preocupante, carecendo de uma intervenção rápida com o objectivo de minimizar a exposição e prevenir os potenciais efeitos para a saúde dos trabalhadores expostos.
Resumo:
RESUMO - A exposição a formaldeído é reconhecidamente um dos mais importantes factores de risco presente nos laboratórios hospitalares de anatomia patológica. Neste contexto ocupacional, o formaldeído é utilizado em solução, designada comummente por formol. Trata-se de uma solução comercial de formaldeído, normalmente diluída a 10%, sendo pouco onerosa e, por esse motivo, a eleita para os trabalhos de rotina em anatomia patológica. A solução é utilizada como fixador e conservante do material biológico, pelo que as peças anatómicas a serem processadas são previamente impregnadas. No que concerne aos efeitos para a saúde do formaldeído, os efeitos locais parecem apresentar um papel mais importante comparativamente com os efeitos sistémicos, devido à sua reactividade e rápido metabolismo nas células da pele, tracto gastrointestinal e pulmões. Da mesma forma, a localização das lesões correspondem principalmente às zonas expostas às doses mais elevadas deste agente químico, ou seja, o desenvolvimento dos efeitos tóxicos dependerá mais da intensidade da dose externa do que da duração da exposição. O efeito do formaldeído no organismo humano mais facilmente detectável é a acção irritante, transitória e reversível sobre as mucosas dos olhos e aparelho respiratório superior (naso e orofaringe), o que acontece em geral para exposições frequentes e superiores a 1 ppm. Doses elevadas são citotóxicas e podem conduzir a degenerescência e necrose das mucosas e epitélios. No que concerne aos efeitos cancerígenos, a primeira avaliação efectuada pela International Agency for Research on Cancer data de 1981, actualizada em 1982, 1987, 1995 e 2004, considerando-o como um agente cancerígeno do grupo 2A (provavelmente carcinogénico). No entanto, a mais recente avaliação, em 2006, considera o formaldeído no Grupo 1 (agente carcinogénico) com base na evidência de que a exposição a este agente é susceptível de causar cancro nasofaríngeo em humanos. Constituiu objectivo principal deste estudo caracterizar a exposição profissional a formaldeído nos laboratórios hospitalares de anatomia patológica Portugueses. Pretendeu-se, ainda, descrever os fenómenos ambientais da contaminação ambiental por formaldeído e explorar eventuais associações entre variáveis. Considerou-se uma amostra de 10 laboratórios hospitalares de anatomia patológica, avaliada a exposição dos três grupos profissionais por comparação com os dois referenciais de exposição e, ainda, conhecidos os valores de concentração máxima em 83 actividades. Foram aplicados simultaneamente dois métodos distintos de avaliação ambiental: um dos métodos (Método 1) fez uso de um equipamento de leitura directa com o princípio de medição por Photo Ionization Detection, com uma lâmpada de 11,7 eV e, simultaneamente, realizou-se o registo da actividade. Este método disponibilizou dados para o referencial de exposição da concentração máxima; o outro método (Método 2) traduziu-se na aplicação do método NIOSH 2541, implicando o uso de bombas de amostragem eléctricas de baixo caudal e posterior processamento analítico das amostras por cromatografia gasosa. Este método, por sua vez, facultou dados para o referencial de exposição da concentração média ponderada. As estratégias de medição de cada um dos métodos e a definição dos grupos de exposição existentes neste contexto ocupacional, designadamente os Técnicos de Anatomia Patológica, os Médicos Anatomo-Patologistas e os Auxiliares, foram possíveis através da informação disponibilizada pelas técnicas de observação da actividade da análise (ergonómica) do trabalho. Estudaram-se diversas variáveis independentes, nomeadamente a temperatura ambiente e a humidade relativa, a solução de formaldeído utilizada, as condições de ventilação existentes e o número médio de peças processadas por dia em cada laboratório. Para a recolha de informação sobre estas variáveis foi preenchida, durante a permanência nos laboratórios estudados, uma Grelha de Observação e Registo. Como variáveis dependentes seleccionaram-se três indicadores de contaminação ambiental, designadamente o valor médio das concentrações superiores a 0,3 ppm em cada laboratório, a Concentração Média Ponderada obtida para cada grupo de exposição e o Índice do Tempo de Regeneração de cada laboratório. Os indicadores foram calculados e definidos através dos dados obtidos pelos dois métodos de avaliação ambiental aplicados. Baseada no delineado pela Universidade de Queensland, foi ainda aplicada uma metodologia de avaliação do risco de cancro nasofaríngeo nas 83 actividades estudadas de modo a definir níveis semi-quantitativos de estimação do risco. Para o nível de Gravidade considerou-se a informação disponível em literatura científica que define eventos biológicos adversos, relacionados com o modo de acção do agente químico e os associa com concentrações ambientais de formaldeído. Para o nível da Probabilidade utilizou-se a informação disponibilizada pela análise (ergonómica) de trabalho que permitiu conhecer a frequência de realização de cada uma das actividades estudadas. A aplicação simultânea dos dois métodos de avaliação ambiental resultou na obtenção de resultados distintos, mas não contraditórios, no que concerne à avaliação da exposição profissional a formaldeído. Para as actividades estudadas (n=83) verificou-se que cerca de 93% dos valores são superiores ao valor limite de exposição definido para a concentração máxima (VLE-CM=0,3 ppm). O “exame macroscópico” foi a actividade mais estudada e onde se verificou a maior prevalência de resultados superiores ao valor limite (92,8%). O valor médio mais elevado da concentração máxima (2,04 ppm) verificou-se no grupo de exposição dos Técnicos de Anatomia Patológica. No entanto, a maior amplitude de resultados observou-se no grupo dos Médicos Anatomo-Patologistas (0,21 ppm a 5,02 ppm). No que respeita ao referencial da Concentração Média Ponderada, todos os valores obtidos nos 10 laboratórios estudados para os três grupos de exposição foram inferiores ao valor limite de exposição definido pela Occupational Safety and Health Administration (TLV-TWA=0,75 ppm). Verificou-se associação estatisticamente significativa entre o número médio de peças processadas por laboratório e dois dos três indicadores de contaminação ambiental utilizados, designadamente o valor médio das concentrações superiores a 0,3 ppm (p=0,009) e o Índice do Tempo de Regeneração (p=0,001). Relativamente à temperatura ambiente não se observou associação estatisticamente significativa com nenhum dos indicadores de contaminação ambiental utilizados. A humidade relativa apresentou uma associação estatisticamente significativa apenas com o indicador de contaminação ambiental da Concentração Média Ponderada de dois grupos de exposição, nomeadamente com os Médicos Anatomo-Patologistas (p=0,02) e os Técnicos de Anatomia Patológica (p=0,04). A aplicação da metodologia de avaliação do risco nas 83 actividades estudadas permitiu verificar que, em cerca de dois terços (35%), o risco foi classificado como (pelo menos) elevado e, ainda, constatar que 70% dos laboratórios apresentou pelo menos 1 actividade com a classificação de risco elevado. Da aplicação dos dois métodos de avaliação ambiental e das informações obtidas para os dois referenciais de exposição pode concluir-se que o referencial mais adequado é a Concentração Máxima por estar associado ao modo de actuação do agente químico. Acresce, ainda, que um método de avaliação ambiental, como o Método 1, que permite o estudo das concentrações de formaldeído e simultaneamente a realização do registo da actividade, disponibiliza informações pertinentes para a intervenção preventiva da exposição por permitir identificar as actividades com a exposição mais elevada, bem como as variáveis que a condicionam. As peças anatómicas apresentaram-se como a principal fonte de contaminação ambiental por formaldeído neste contexto ocupacional. Aspecto de particular interesse, na medida que a actividade desenvolvida neste contexto ocupacional e, em particular na sala de entradas, é centrada no processamento das peças anatómicas. Dado não se perspectivar a curto prazo a eliminação do formaldeído, devido ao grande número de actividades que envolvem ainda a utilização da sua solução comercial (formol), pode concluir-se que a exposição a este agente neste contexto ocupacional específico é preocupante, carecendo de uma intervenção rápida com o objectivo de minimizar a exposição e prevenir os potenciais efeitos para a saúde dos trabalhadores expostos. ---------------- ABSTRACT - Exposure to formaldehyde is recognized as one of the most important risk factors present in anatomy and pathology laboratories from hospital settings. In this occupational setting, formaldehyde is used in solution, typically diluted to 10%, and is an inexpensive product. Because of that, is used in routine work in anatomy and pathology laboratories. The solution is applied as a fixative and preservative of biological material. Regarding formaldehyde health effects, local effects appear to have a more important role compared with systemic effects, due to his reactivity and rapid metabolism in skin, gastrointestinal tract and lungs cells. Likewise, lesions location correspond mainly to areas exposed to higher doses and toxic effects development depend more on external dose intensity than exposure duration. Human body formaldehyde effect more easily detectable is the irritating action, transient and reversible on eyes and upper respiratory tract (nasal and throat) membranes, which happen in general for frequent exposure to concentrations higher than 1 ppm. High doses are cytotoxic and can lead to degeneration, and also to mucous membranes and epithelia necrosis. With regard to carcinogenic effects, first assessment performed by International Agency for Research on Cancer in 1981, updated in 1982, 1987, 1995 and 2004, classified formaldehyde in Group 2A (probably carcinogenic). However, most recent evaluation in 2006, classifies formaldehyde carcinogenic (Group 1), based on evidence that exposure to this agent is likely to cause nasopharyngeal cancer in humans. This study principal objective was to characterize occupational exposure to formaldehyde in anatomy and pathology hospital laboratories, as well to describe formaldehyde environmental contamination phenomena and explore possible associations between variables. It was considered a sample of 10 hospital pathology laboratories, assessed exposure of three professional groups for comparison with two exposure metrics, and also knows ceiling concentrations in 83 activities. Were applied, simultaneously, two different environmental assessment methods: one method (Method 1) using direct reading equipment that perform measure by Photo Ionization Detection, with 11,7 eV lamps and, simultaneously, make activity description and film. This method provided data for ceiling concentrations for each activity study (TLV-C). In the other applied method (Method 2), air sampling and formaldehyde analysis were performed according to NIOSH method (2541). This method provided data average exposure concentration (TLV-TWA). Measuring and sampling strategies of each methods and exposure groups definition (Technicians, Pathologists and Assistants) was possible by information provided by activities (ergonomic) analysis. Several independent variables were studied, including temperature and relative humidity, formaldehyde solution used, ventilation conditions, and also anatomic pieces mean value processed per day in each laboratory. To register information about these variables was completed an Observation and Registration Grid. Three environmental contamination indicators were selected has dependent variables namely: mean value from concentrations exceeding 0,3 ppm in each laboratory, weighted average concentration obtained for each exposure group, as well each laboratory Time Regeneration Index. These indicators were calculated and determined through data obtained by the two environmental assessment methods. Based on Queensland University proposal, was also applied a methodology for assessing nasopharyngeal cancer risk in 83 activities studied in order to obtain risk levels (semi-quantitative estimation). For Severity level was considered available information in scientific literature that defines biological adverse events related to the chemical agent action mode, and associated with environment formaldehyde concentrations. For Probability level was used information provided by (ergonomic) work analysis that helped identifies activity frequency. Environmental assessment methods provide different results, but not contradictory, regarding formaldehyde occupational exposure evaluation. In the studied activities (n=83), about 93% of the values were above exposure limit value set for ceiling concentration in Portugal (VLE-CM = 0,3 ppm). "Macroscopic exam" was the most studied activity, and obtained the higher prevalence of results superior than 0,3 ppm (92,8%). The highest ceiling concentration mean value (2,04 ppm) was obtain in Technicians exposure group, but a result wider range was observed in Pathologists group (0,21 ppm to 5,02 ppm). Concerning Method 2, results from the three exposure groups, were all lower than limit value set by Occupational Safety and Health Administration (TLV-TWA=0,75ppm). There was a statistically significant association between anatomic pieces mean value processed by each laboratory per day, and two of the three environmental contamination indicators used, namely average concentrations exceeding 0,3 ppm (p=0,009) and Time Regeneration Index (p=0,001). Temperature was not statistically associated with any environmental contamination used indicators. Relative humidity had a statistically significant association only with one environmental contamination indicator, namely weighted average concentration, particularly with Pathologists group (p=0,02) and Technicians group (p=0,04). Risk assessment performed in the 83 studied activities showed that around two thirds (35%) were classified as (at least) high, and also noted that 70% of laboratories had at least 1 activity with high risk rating. The two environmental assessment methods application, as well information obtained from two exposure metrics, allowed to conclude that most appropriate exposure metric is ceiling concentration, because is associated with formaldehyde action mode. Moreover, an environmental method, like Method 1, which allows study formaldehyde concentrations and relates them with activity, provides relevant information for preventive information, since identifies the activity with higher exposure, as well variables that promote exposure. Anatomic pieces represent formaldehyde contamination main source in this occupational setting, and this is of particular interest because all activities are focused on anatomic pieces processing. Since there is no prospect, in short term, for formaldehyde use elimination due to large number of activities that still involve solution use, it can be concluded that exposure to this agent, in this particular occupational setting, is preoccupant, requiring an rapid intervention in order to minimize exposure and prevent potential health effects in exposed workers.
Resumo:
O controlo da qualidade em ressonância magnética (RM) passa pela realização de diversos testes ao equipamento e calibrações diárias, onde os fantomas desempenham um papel fundamental. Este trabalho teve como objetivo principal o desenvolvimento de um fantoma cerebral para um sistema de RM de intensidade 3.0 Tesla. Com base na literatura existente, escolheram-se como reagentes o cloreto de gadolínio (III) (GdCl3), a agarose, e o gelificante carragena, tendo sido ainda acrescentado o conservante químico azida de sódio (NaN3) de forma a inibir a degradação da solução. Realizaram-se vários testes com diferentes concentrações dos materiais selecionados até obter as misturas adequadas a suscetibilidade magnética das substâncias branca e cinzenta cerebrais. Os tempos de relaxação T1 das diversas substâncias desenvolvidas foram medidos, apresentando o fantoma final uns tempos de T1 de 702±10 ms, quando a concentração de GdCl3 foi de 100 µmol (substância branca) e 1179±23 ms quando a concentração foi de 15 µmol (substância cinzenta). Os valores de T1 do fantoma foram comparados estatisticamente com os tempos de relaxação conseguidos a partir de um cérebro humano, obtendo-se uma correlação de 0.867 com significância estatística. No intuito de demonstrar a aplicabilidade do fantoma, este foi sujeito a um protocolo de RM, do qual constaram as sequências habitualmente usadas no estudo cerebral. Como principais resultados constatou-se que, nas sequências ponderadas em T1, o fantoma apresenta uma forte associação positiva (rs > 0.700 p = 0.072) com o cérebro de referência, ainda que não sejam estatisticamente significativos. As sequências ponderadas em T2 demonstraram uma correlação positiva moderada e fraca, sendo a ponderação densidade protónica a única a apresentar uma associação negativa. Desta forma, o fantoma revelou-se um ótimo substituto do cérebro humano. Este trabalho culminou na criação de um modelo cerebral tridimensional onde foram individualizadas as regiões das substâncias branca e cinzenta, de forma a posteriormente serem preenchidas pelas correspondentes substâncias desenvolvidas, obtendo-se um fantoma cerebral antropomórfico.
Resumo:
O camu-camu [Myrciaria dubia (Humb., Bonpl. & Kunth) McVaugh], da família Myrtaceae, é encontrado em áreas inundáveis da Região Amazônica e utilizado como conservante em antioxidantes por seu alto teor de ácido ascórbico. O objetivo deste trabalho foi avaliar porta-enxertos desta família, adaptados a terra firme, visando à propagação vegetativa de camu-camu. Selecionaram-se duzentas e quarenta mudas de camu-camu, goiabeira (Psidium guajava L.) e pitangueira (Eugenia uniflora L.), que receberam quatro tipos de enxertia, originando doze tratamentos de sessenta plantas, com cinco repetições. Apenas o porta-enxerto de camu-camu se mostrou compatível. A incompatibilidade entre camu-camu e os porta-enxertos de goiabeira e pitangueira foi demonstrada por análises anatômicas.
Resumo:
A preocupação quanto a conservação de peças anatômicas existe a mais de 5 mil anos, pois o uso de peças cadavéricas são indispensáveis para o ensino, contribuindo com a melhora das habilidades aplicativas, assimilativas e compreensivas da disciplina. Esse trabalho propõe maior utilização das técnicas apresentadas em laboratórios de anatomia, visando abolir o uso do formol como conservante, permitindo um ambiente agradável para a prática da relação ensino-aprendizagem. Para isso foram utilizadas quatro técnicas anatômicas, a criodesidratação, glicerinação, injeção de látex e injeção de vinilite seguido de corrosão, que foram executadas utilizando cães, gatos e órgãos provenientes de doações. Com a criodesidratação e glicerinação os materiais anatômicos ficaram consideravelmente mais leves do que eram quando mantidos em formol, mantendo-se inodoros, diferente do evidenciado na utilização de formol e outros conservantes. As estruturas de estudo das peças ficaram intactas, de fácil visualização e o armazenamento passou a ser feito em caixas fechadas sem qualquer tipo de liquido, mantendo-se assim por até 3 anos. As técnicas de injeção de látex e vinilite seguido de corrosão mostraram total eficiência preenchendo os sistemas injetados, podendo visualizar as ramificações e todo caminho percorrido no sistema circulatório. As quatro técnicas anatômicas estudadas nesse trabalho mostraram ser suficientes para atender as necessidades dos estudantes quanto ao estudo da anatomia, devido à perfeita evidenciação de estruturas externas e internas dos animais.
Resumo:
Resumo: Para avaliar o perfil bioquímico, inclusive proteínas, do soro lácteo de búfalas Murrah primíparas e pluríparas sadias foram analisadas amostras de leite de 30 fêmeas bubalinas durante uma lactação completa. Os animais foram distribuídos em três grupos: G1 - 10 búfalas primíparas, G2 - 10 búfalas pluríparas com duas a três lactações e G3 - 10 búfalas pluríparas com mais de três lactações. O período de lactação foi dividido em: fase inicial (I: primeiro ao terceiro mês de lactação), fase intermediária (T: quarto ao sexto mês de lactação) e fase final (F: sétimo ao nono mês de lactação). Antes da colheita das amostras de leite foram realizados o exame físico da glândula mamária, o teste da caneca de fundo escuro e o California Mastitis Test (CMT). Após a assepsia dos quartos mamários, foram colhidas mensalmente, durante uma lactação completa, amostras de 20mL de leite de cada quarto mamário, em frascos plásticos esterilizados e sem conservante, para a realização do isolamento microbiológico, determinação do perfil bioquímico e fracionamento proteico por meio de eletroforese em gel de poliacrilamida contendo dodecil sulfato de sódio (SDS-PAGE), e amostras de 30mL de leite de cada quarto mamário, em frascos plásticos esterilizados contendo conservante bronopol, para contagem de células somáticas (CCS). Das 1.042 amostras de leite colhidas dos três grupos experimentais durante a lactação, 923 amostras de leite apresentaram reação negativa ao CMT e isolamento microbiológico negativo e foram selecionadas para as análises do perfil bioquímico e fracionamento proteico em SDS-PAGE. Notou-se influência da ordem de parto e da fase da lactação no perfil bioquímico e no proteinograma do soro lácteo de búfalas da raça Murrah sadias. As búfalas primíparas (G1) apresentaram maior atividade das enzimas gamaglutamiltransferase (GGT: 2.346U/L) e fosfatase alcalina (ALP: 181U/L) e maiores concentrações de fósforo (P: 56,6mg/dL), potássio (K: 32,0mg/dL) e α-lactoalbumina (458mg/dL). As fêmeas com duas a três lactações (G2) apresentaram maior CCS (70.700 células/mL) e maiores concentrações de proteína total (1,55g/dL), albumina (100mg/dL), magnésio (Mg: 8,80mg/dL), cloretos (Cl: 176mg/dL), ferro (Fe: 10,7μg/dL), sódio (Na: 178mMol/L) e lactoferrina (59,5mg/dL). As fêmeas com mais de três lactações (G3) apresentaram maiores concentrações de cálcio total (Ca: 41,8mg/dL), cálcio ionizado (Cai: 2,92mMol/L), imunoglobulina A (IgA: 1,32mg/dL), albumina sérica (99,1mg/dL), imunoglobulina G (IgG: 49,7mg/dL) e b-lactoglobulina (1.068mg/dL). Durante a lactação foi observado aumento da CCS, aumento das atividades das enzimas GGT e ALP, aumento das concentrações de proteína total, albumina, P, Mg, Cl, Na, lactoferrina, albumina sérica, IgG, α-lactoalbumina e redução das concentrações de Ca, Fe, Cai, K, IgA e b-lactoglobulina no soro lácteo das búfalas. Os resultados obtidos podem ser utilizados como referências para a espécie bubalina e auxiliar no diagnóstico e no prognóstico de doenças de ocorrência comum na fase de lactação.
Resumo:
Este trabalho teve como objetivo avaliar os parâmetros de qualidade e a aceitabilidade de passas de pêssego submetidas à pré-secagem osmótica. Foram realizados três tratamentos, sendo dois para efeito comparativo, pêssegos não revestidos antes da desidratação osmótica (Tratamento 1) e revestidos com cobertura de alginato (Tratamento 2) e um terceiro tratamento, sem revestimento, com emprego de conservante químico na solução osmótica para verificar a conservação da passa à temperatura ambiente. Os frutos foram branqueados, desidratados osmoticamente em solução de sacarose a 60°Brix a 45°C por 5 horas e secos em estufa ventilada a 65°C até umidade final de 22% determinada pelo controle de peso. A cobertura com alginato reduziu a incorporação de sólidos e aumentou a perda de umidade. As passas elaboradas nos Tratamentos 1 e 2 foram submetidas à avaliação sensorial, tendo apresentado boa aceitação geral. Os frutos armazenados à temperatura ambiente apresentaram contaminação microbiológica após 40 dias independentemente do tipo de embalagem utilizada (saco plástico, embalagem de polietileno ou celofane), enquanto as passas elaboradas com conservante (Tratamento 3) não apresentaram sintomas visuais de crescimento microbiano nesse mesmo período.
Resumo:
Com o objetivo de acompanhar a estabilidade físico-química e microbiológica da carne mecanicamente separada (CMS) de diferentes origens e estocada durante 99 dias a -18 °C, foi realizada prévia mistura de conservante (nitrito de sódio) e antioxidante (eritorbato de sódio) em CMS obtida de duas linhagens de aves: galinhas matrizes de corte e galinhas poedeiras comerciais brancas. Na CMS de cada linhagem foram realizados três diferentes tratamentos: 1) controle (sem aditivos); 2) adição de 150 ppm de nitrito; e 3) adição de 150 ppm de nitrito e 500 ppm de eritorbato. Os resultados encontrados demonstraram que a adição de nitrito isoladamente não impediu a oxidação lipídica, avaliada através do índice de TBARS, nem a alteração na cor, avaliada em colorímetro. Por outro lado, a adição de nitrito juntamente com eritorbato foi efetiva na redução dos problemas de oxidação lipídica na CMS de galinhas matrizes, e em menor grau, na CMS de poedeiras. A adição de nitrito e eritorbato na CMS também melhorou a preservação da cor vermelha desejável (a*) ao longo do tempo. A avaliação da estabilidade microbiológica da CMS, realizada no primeiro e último dia de estocagem congelada, para microrganismos mesófilos, Escherichia coli, Staphylococcus aureus, Clostridium perfringens e Pseudomonas spp., e quinzenalmente para microrganismos psicrotróficos, indicou que não houve uma variação significativa nas contagens em função do tratamento utilizado (diferentes aditivos adicionados). Não foi detectada Salmonella spp. em nenhuma das amostras analisadas. Em função da melhoria da estabilidade oxidativa, recomenda-se a adição de nitrito (150 ppm) e eritorbato (500 ppm) em CMS de galinhas matrizes a ser estocada congelada por um período prolongado.