270 resultados para Computerised videotape


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Using a computer-based videotape analysis system, a randomized series of golf swings was presented to 10 professional and 10 amateur golf coaches in an attempt to determine differences m their internal model of golf swing kinematics. A global measure was obtained by having coaches independently inspect the swings of eight golfers and estimate their golf handicaps. A micro level of analysis was undertaken by requiring participants to indicate what they considered to be 'ideal' swing characteristics using 17 predetermined limb, club, and body position angles for various phases of the swing Videotaped swings for a highly skilled and beginner level golfer were used for this task. Although the training requirements for professional coaches are much more demanding and their playing ability higher, evidence of internal model differences was not found in the handicap estimation task. It was also established that a golfer's swing may be perceived to have deficiencies but still produce sufficient accuracy to engender a low handicap On the second task, only one of the 17 estimated swing angles showed a significant difference between the coach groups. When, however, the two coach groups indicated their preferred angles for the highly skilled golfer and the beginner, 6 of the 17 angles were significantly different. The implications of these findings are that the two coach groups had similar ability to identify fundamental characteristics of the golf swing, but their model of the ideal swing was influenced by the observed golfer's skill level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There have been powerful incentives for Tasmanian Small and Medium-sized Enterprises (SMEs) to adopt information technology to enable them to remain competitive and to comply with legislative regulations. This research study was undertaken to establish whether SMEs implementing computerised accounting systems have a subsequent change in their external accountancy fees. The research study employed a quantitative methodology using survey questionnaires. The study found that in less than 3% of cases SMEs reported a decrease in accountancy fees, in almost 45% of cases the organisation actually experienced a slight to substantial fee increase while 52% reported no change in accountancy fees.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Echocardiography is the commonest form of non-invasive cardiac imaging and is fundamental to patient management. However, due to its methodology, it is also operator dependent. There are well defined pathways in training and ongoing accreditation to achieve and maintain competency. To satisfy these requirements, significant time has to be dedicated to scanning patients, often in the time pressured clinical environment. Alternative, computer based training methods are being considered to augment echocardiographic training. Numerous advances in technology have resulted in the development of interactive programmes and simulators to teach trainees the skills to perform particular procedures, including transthoracic and transoesophageal echocardiography. 82 sonographers and TOE proceduralists utilised an echocardiographic simulator and assessed its utility using defined criteria. 40 trainee sonographers assessed the simulator and were taught how to obtain an apical 2 chamber (A2C) view and image the superior vena cava (SVC). 100% and 88% found the simulator useful in obtaining the SVC or A2C view respectively. All users found it easy to use and the majority found it helped with image acquisition and interpretation. 42 attendees of a TOE training day utilising the simulator assessed the simulator with 100% finding it easy to use, as well as the augmented reality graphics benefiting image acquisition. 90% felt that it was realistic. This study revealed that both trainee sonographers and TOE proceduralists found the simulation process was realistic, helped in image acquisition and improved assessment of spatial relationships. Echocardiographic simulators may play an important role in the future training of echocardiographic skills.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 2004, my thirtieth year of life, I began to develop and produce a documentary about the lived experience of being intersex. At the time, I didn’t ever expect the film would be autobiographical in nature. I’d known I was intersex since I was 17, and aware of my difference for many years prior, and I’d been making and presenting documentaries for almost as long, yet the idea to expose myself so publicly was frightening to me. However, I realised I couldn’t expect others to step in front of the lens when I didn’t have the courage to do so myself. The final result was Orchids: My Intersex Adventure, which maps my intersex journey from shame, stigma and secrecy to self‐acceptance. The film has now been broadcast on television sets around the world. It has also won many awards and appeared in numerous film festivals....

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous studies have revealed considerable interobserver and intraobserver variation in the histological classification of preinvasive cervical squamous lesions. The aim of the present study was to develop a decision support system (DSS) for the histological interpretation of these lesions. Knowledge and uncertainty were represented in the form of a Bayesian belief network that permitted the storage of diagnostic knowledge and, for a given case, the collection of evidence in a cumulative manner that provided a final probability for the possible diagnostic outcomes. The network comprised 8 diagnostic histological features (evidence nodes) that were each independently linked to the diagnosis (decision node) by a conditional probability matrix. Diagnostic outcomes comprised normal; koilocytosis; and cervical intraepithelial neoplasia (CIN) 1, CIN II, and CIN M. For each evidence feature, a set of images was recorded that represented the full spectrum of change for that feature. The system was designed to be interactive in that the histopathologist was prompted to enter evidence into the network via a specifically designed graphical user interface (i-Path Diagnostics, Belfast, Northern Ireland). Membership functions were used to derive the relative likelihoods for the alternative feature outcomes, the likelihood vector was entered into the network, and the updated diagnostic belief was computed for the diagnostic outcomes and displayed. A cumulative probability graph was generated throughout the diagnostic process and presented on screen. The network was tested on 50 cervical colposcopic biopsy specimens, comprising 10 cases each of normal, koilocytosis, CIN 1, CIN H, and CIN III. These had been preselected by a consultant gynecological pathologist. Using conventional morphological assessment, the cases were classified on 2 separate occasions by 2 consultant and 2 junior pathologists. The cases were also then classified using the DSS on 2 occasions by the 4 pathologists and by 2 medical students with no experience in cervical histology. Interobserver and intraobserver agreement using morphology and using the DSS was calculated with K statistics. Intraobserver reproducibility using conventional unaided diagnosis was reasonably good (kappa range, 0.688 to 0.861), but interobserver agreement was poor (kappa range, 0.347 to 0.747). Using the DSS improved overall reproducibility between individuals. Using the DSS, however, did not enhance the diagnostic performance of junior pathologists when comparing their DSS-based diagnosis against an experienced consultant. However, the generation of a cumulative probability graph also allowed a comparison of individual performance, how individual features were assessed in the same case, and how this contributed to diagnostic disagreement between individuals. Diagnostic features such as nuclear pleomorphism were shown to be particularly problematic and poorly reproducible. DSSs such as this therefore not only have a role to play in enhancing decision making but also in the study of diagnostic protocol, education, self-assessment, and quality control. (C) 2003 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prescribing of drugs in the therapeutic classes that are affected by the government's limited list was investigated in a computerised group practice of just over 3,000 patients. Prescribable drugs in categories that are affected by the list were identified for two consecutive six month periods before and one six month period after the introduction of the list. A significant decrease in the prescribing of cough and cold remedies, vitamins, and antacids occurred after the list was introduced, whereas no change occurred in the prescribing of laxatives, benzodiazepines, or analgesics. The prescribing of iron and penicillin increased significantly after the list was introduced, whereas the use of H2 antagonists and non-steroidal anti-inflammatory drugs showed no significant change.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims - To study the interchangeability of the measurements of the optic disc topography obtained by one computerised image analyser and one confocal laser tomographic scanner. Methods - One eye of 28 patients with glaucoma or glaucoma suspects was studied. All cases had simultaneous stereoscopic disc photographs taken with the fundus camera Topcon TRC-SS and optic disc examination with the Heidelberg retina tomograph (HRT) during the same visit. The optic disc photographs were digitised and analysed with the Topcon ImageNet (TI) system. Three variables of the optic disc topography provided by the TI and the HRT were compared - cup volume (CV), rim area (RA), and cup area to disc area ratio (CA/DA). Results - The mean values of CV and RA provided by the TI (0.52 (SD 0.32) mm and 1.58 (0.39) mm , respectively) were greater (p <0.01) than the mean values of CV and RA determined by the HRT (0.32 (0.25) mm , and 1.33 (0.47) mm , respectively). The mean value of CA/DA provided by the TI (0.42 (0.14)) and the HRT (0.42 (0.18)) was similar (p = 0.93). Correlation coefficients between measurements obtained by the two methods ranged from 0.53 to 0.73. Conclusion - There was a significant discrepancy in the measurements of rim area and cup volume of the optic disc obtained by a computerised image analyser and a laser scanning tomograph.