927 resultados para Computer-aided analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using the link-link incidence matrix to represent a simple-jointed kinematic chain algebraic procedures have been developed to determine its structural characteristics such as the type of freedom of the chain, the number of distinct mechanisms and driving mechanisms that can be derived from the chain. A computer program incorporating these graph theory based procedures has been applied successfully for the structural analysis of several typical chains.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Most of the modern distance relays are designed to avoid overreaching due to the transient d.c. component of the fault current, whereas a more likely source of transients in e.h.v. systems is the oscillatory discharge of the system charging current into the fault. Until now attempts have not been made to reproduce these transients in the laboratory. This paper describes an analogue and an accurate digital simulation of these harmonic transients. The dynamic behaviour of a typical polarised mho-type relay is analysed, and results are presented. The paper also advocates the use of active filters for filtering the harmonics associated with e.h.v. system, and hence, to improve the speed of response and accuracy of the protective relays.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper is a result of a fruitful cooperation between the computer science and the dental diagnosis experiences. The study presents a new approach of applying computer algorithms to radiographic images of dental implantation used for bone regeneration. We focus here only on the contribution of the computer assistance to the clinical research as the periodontal therapy is beyond the scope of this paper. The proposed system is based on a pattern recognition approach, directed to recognize density changes in the intra-bony affected areas of patients. It comprises different modules with new algorithms specially designed to treat the patients’ radiographic images more accurately. The system includes digitizing, detecting the complicated region of interest (ROI), defining reference area to correct any projection discrepancy of the follow up images, and finally to extract the distinguishing features of the ROI as a basis for determining the rate of new bone density accumulation. This study is applied to two typical dental cases for a patient who received two different operations. The results are very encouraging and more accurate than traditional techniques reported before.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a new module of the expert system SISTEMAT used for the prediction of the skeletons of neolignans by (13)C NMR, (1)H NMR and botanical data obtained from the literature. SISTEMAT is composed of MACRONO, SISCONST, C13MACH, H1MACH and SISOCBOT programs, each analyzing data of the neolignan in question to predict the carbon skeleton of the compound. From these results, the global probability is computed and the most probable skeleton predicted. SISTEMAT predicted the skeletons of 75% of the 20 neolignans tested, in a rapid and simple procedure demonstrating its advantage for the structural elucidation of new compounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Computer aided joint replacement surgery has become very popular during recent years and is being done in increasing numbers all over the world. The accuracy of the system depends to a major extent, on accurate registration and immobility of the tracker attachment devices to the bone. This study was designed to asses the forces needed to displace the tracker attachment devices in the bone simulators. Bone simulators were used to maintain the uniformity of the bone structure during the study. The fixation devices tested were 3mm diameter self drilling, self tapping threaded pin, 4mm diameter self tapping cortical threaded pin, 5mm diameter self tapping cancellous threaded pin and a triplanar fixation device ‘ortholock’ used with three 3mm pins. All the devices were tested for pull out, translational and rotational forces in unicortical and bicortical fixation modes. Also tested was the normal bang strength and forces generated by leaning on the devices. The forces required to produce translation increased with the increasing diameter of the pins. These were 105N, 185N, and 225N for the unicortical fixations and 130N, 200N, 225N for the bicortical fixations for 3mm, 4mm and 5mm diameter pins respectively. The forces required to pull out the pins were 1475N, 1650N, 2050N for the unicortical, 1020N, 3044N and 3042N for the bicortical fixated 3mm, 4mm and 5mm diameter pins. The ortholock translational and pull out strength was tested to 900N and 920N respectively and still it did not fail. Rotatory forces required to displace the tracker on pins was to the magnitude of 30N before failure. The ortholock device had rotational forces applied up to 135N and still did not fail. The manual leaning forces and the sudden bang forces generated were of the magnitude of 210N and 150N respectively. The strength of the fixation pins increases with increasing diameter from three to five mm for the translational forces. There is no significant difference in pull out forces of four mm and five mm diameter pins though it is more that the three mm diameter pins. This is because of the failure of material at that stage rather than the fixation device. The rotatory forces required to displace the tracker are very small and much less that that can be produced by the surgeon or assistants in single pins. Although the ortholock device was tested to 135N in rotation without failing, one has to be very careful not to put any forces during the operation on the tracker devices to ensure the accuracy of the procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An intelligent computer aided defect analysis (ICADA) system, based on artificial intelligence techniques, has been developed to identify design, process or material parameters which could be responsible for the occurrence of defective castings in a manufacturing campaign. The data on defective castings for a particular time frame, which is an input to the ICADA system, has been analysed. It was observed that a large proportion, i.e. 50-80% of all the defective castings produced in a foundry, have two, three or four types of defects occurring above a threshold proportion, say 10%. Also, a large number of defect types are either not found at all or found in a very small proportion, with a threshold value below 2%. An important feature of the ICADA system is the recognition of this pattern in the analysis. Thirty casting defect types and a large number of causes numbering between 50 and 70 for each, as identified in the AFS analysis of casting defects-the standard reference source for a casting process-constituted the foundation for building the knowledge base. Scientific rationale underlying the formation of a defect during the casting process was identified and 38 metacauses were coded. Process, material and design parameters which contribute to the metacauses were systematically examined and 112 were identified as rootcauses. The interconnections between defects, metacauses and rootcauses were represented as a three tier structured graph and the handling of uncertainty in the occurrence of events such as defects, metacauses and rootcauses was achieved by Bayesian analysis. The hill climbing search technique, associated with forward reasoning, was employed to recognize one or several root causes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A computer-aided procedure is described for analyzing the reliability of complicated networks. This procedure breaks down a network into small subnetworks whose reliability can be more readily calculated. The subnetworks which are searched for are those with only two nodes; this allows the original network to be considerably simplified.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A computer-aided procedure is described for analyzing the reliability of complicated networks. This procedure breaks down a network into small subnetworks whose reliability can be more readily calculated. The subnetworks which are searched for are those with only two nodes; this allows the original network to be considerably simplified.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper discusses a computer-aided methodology for thickness strain analysis (TSA) of sheet metal stampings using geometry and strain information that is extracted from finite element analysis (FEA) results. The system utilises both FEA results and an ultrasonic gauge capability expert system to assist press shop personnel, providing them with capabilities such as optimum measurement point location and an estimate of gauge error. Key advantages of this enhanced TSA methodology are related to overall efficiency and accuracy gains.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An ultrasonometric and computed-tomographic study of bone healing was undertaken using a model of a transverse mid-shaft osteotomy of sheep tibiae fixed with a semi-flexible external fixator. Fourteen sheep were operated and divided into two groups of seven according to osteotomy type, either regular or by segmental resection. The animals were killed on the 90th postoperative day and the tibiae resected for the in vitro direct contact transverse and axial measurement of ultrasound propagation velocity (UV) followed by quantitative computer-aided tomography (callus density and volume) through the osteotomy site. The intact left tibiae were used for control, being examined in a symmetrical diaphyseal segment. Regular osteotomies healed with a smaller and more mature callus than resection osteotomies. Axial UV was consistently and significantly higher (p?=?0.01) than transverse UV and both transverse and axial UV were significantly higher for the regular than for the segmental resection osteotomy. Transverse UV did not differ significantly between the intact and operated tibiae (p?=?0.20 for regular osteotomy; p?=?0.02 for resection osteotomy), but axial UV was significantly higher for the intact tibiae. Tomographic callus density was significantly higher for the regular than for the resection osteotomy and higher than both for the intact tibiae, presenting a strong positive correlation with UV. Callus volume presented an opposite behavior, with a negative correlation with UV. We conclude that UV is at least as precise as quantitative tomography for providing information about the healing state of both regular and resection osteotomy. (C) 2011 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 30:10761082, 2012

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Percutaneous nephrolithotomy (PCNL) for the treatment of renal stones and other related renal diseases has proved its efficacy and has stood the test of time compared with open surgical methods and extracorporal shock wave lithotripsy. However, access to the collecting system of the kidney is not easy because the available intra-operative image modalities only provide a two dimensional view of the surgical scenario. With this lack of visual information, several punctures are often necessary which, increases the risk of renal bleeding, splanchnic, vascular or pulmonary injury, or damage to the collecting system which sometimes makes the continuation of the procedure impossible. In order to address this problem, this paper proposes a workflow for introduction of a stereotactic needle guidance system for PCNL procedures. An analysis of the imposed clinical requirements, and a instrument guidance approach to provide the physician with a more intuitive planning and visual guidance to access the collecting system of the kidney are presented.