944 resultados para Comparison of performance


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conjugated polymers are promising materials for electrochromic device technology. Aqueous dispersions of poly(3,4-ethylenedioxythiophene)-(PEDOT) were spin coated onto transparent conducting oxide (TCO) coated glass substrates. A seven-layer electrochromic device was fabricated with the following configuration: glass/transparent conducting oxide (TCO)/PEDOT (main electrochromic layer)/gel electrolyte/prussian blue (counter electrode)/TCO/glass. The device fabricated with counter electrode (Prussian blue) showed a contrast of 18% and without counter electrode showed visible contrast of 5% at 632 nm at a voltage of 1.9 V. The comparison of the device is done in terms of the colouration efficiency of the devices with and without counter electrode.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper optical code-division multiple-access (O-CDMA) packet network is considered, which offers inherent security in the access networks. Two types of random access protocols are proposed for packet transmission. In protocol 1, all distinct codes and in protocol 2, distinct codes as well as shifted versions of all these codes are used. O-CDMA network performance using optical orthogonal codes (OOCs) 1-D and two-dimensional (2-D) wavelength/time single-pulse-per-row (W/T SPR) codes are analyzed. The main advantage of using 2-D codes instead of one-dimensional (1-D) codes is to reduce the errors due to multiple access interference among different users. In this paper, correlation receiver and chip-level receiver are considered in the analysis. Using analytical model, we compute packet-success probability, throughput and compare for OOC and SPR codes in an O-CDMA network and the analysis shows improved performance with SPR codes as compared to OOC codes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tracking systems, that continually orient photovoltaic (PV) panels towards the Sun, are expected to increase the power output from the PV panels. Tremendous amount of research is being done and funds are being spent in order to increase the efficiency of PV cells to generate more power. We report the performance of two almost identical PV systems; one at a fixed latitude tilt and the other on a two-axis tracker. We observed that the fixed axis PV panels generated 336.3 kWh, and the dual-axis Sun-tracked PV panels generated 407.2 kWh during August 2012 March 2013. The tracked panels generated 21.2% more electricity than the optimum tilt angle fixed-axis panels. The cost payback calculations indicate that the additional cost of the tracker can be recovered in 450 days.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates the enhancement of the sensitivity and adsorption efficiency of a localized surface plasmon resonance (LSPR) biosensor that includes a layer of graphene sheet on top of the gold layer. For this purpose, biomolecular interactions of biotin-streptavidin with the graphene layer on the gold thin film are monitored. The performance of the LSPR graphene biosensor is theoretically and numerically assessed in terms of sensitivity and adsorption efficiency under varying conditions, including the thickness of biomolecule layer, number of graphene layers and operating wavelength. Enhanced sensitivity and improved adsorption efficiency are obtained for the LSPR graphene biosensor in comparison with its conventional counterpart. It is found that the LSPR graphene biosensor has better sensitivity with lower operating wavelength and larger number of graphene layers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper deals with the problem of establishing stabilizing state-dependent switching laws in DC-DC converters operating at continuous conduction mode (CCM) and comparing their performance indexes. Firstly, the nature of the problem is defined, that is, the study of switched affine systems, which may not share a common equilibrium point. The concept of stability is, therefore, broadened. Then, the central theorem is proposed, from which a family of switching laws can be derived, namely the minimum law and the hold state law. Some of these are proved to stabilize the basic DC-DC converters and then, their performances are compared to another law, from a previous work, by simulation, where a great reduction in overshoot is obtained. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: An age-controlled comparison concerning patient satisfaction and electrical performance of microfibres (DTL) and rigid contact lens (Henkes) corneal ERG electrodes was carried out. METHODS: 36 test persons underwent complete ophthalmological examination and were equally distributed into 3 age groups. Electroretinograms were recorded according to ISCEV standards. Randomly, in one eye a Henkes electrode was used and in the other eye a DTL electrode. Amplitudes of a- and b-waves and implicit times were measured and compared for the two electrode types. RESULTS: 34 of 36 test persons preferred DTL electrodes. Electrical performance concerning b-wave amplitudes was comparable. Statistically significant differences were detected only for scotopic combined cone-rod stimulation in the age groups 20 - 40 and 41 - 60 years between the different electrodes. Other recordings did not show differences. A statistically significant reduction of signal amplitudes with age was detected for scotopic isolated rod signals and combined cone-rod signals. Significance level was p < 0.05. No conjunctival or corneal erosions were found after ERG recordings for either electrode. CONCLUSIONS: Electrical performance is comparable between electrodes. For scotopic stimulations age was a significant influencing factor for signal amplitude and should be respected for normative values. DTL electrodes were preferred by the vast majority of patients. No adverse clinical effects were observed for either electrode. DTL electrodes should be preferred due to hygienic reasons (single use) and patient comfort.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A sensitive, specific and timely surveillance is necessary to monitor progress towards measles elimination. We evaluated the performance of sentinel and mandatory-based surveillance systems for measles in Switzerland during a 5-year period by comparing 145 sentinel and 740 mandatory notified cases. The higher proportion of physicians who reported at least one case per year in the sentinel system suggests underreporting in the recently introduced mandatory surveillance for measles. Accordingly, the latter reported 2-36-fold lower estimates for incidence rates than the sentinel surveillance. However, these estimates were only 0.6-12-fold lower when we considered confirmed cases alone, which indicates a higher specificity of the mandatory surveillance system. In contrast, the sentinel network, which covers 3.5% of all outpatient consultations, detected only weakly and late a major national measles epidemic in 2003 and completely missed 2 of 10 cantonal outbreaks. Despite its better timeliness and greater sensitivity in case detection, the sentinel system, in the current situation of low incidence, is insufficient to perform measles control and to monitor progress towards elimination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In consequence of rapidly changing market demands companies are permanently encouraged to review their own processes and structures and to modify them. Being one of these developments, order-picking is involved as part of an intra-logistics system. But to take appropriate actions, system performance and system costs have to be measured permanently. Concerning this the use of performance measurement-systems as further development of traditional systems of key figures is suitable. In this paper various performance measurement-systems are compared and their suitability for an implementation in order-picking systems is estimated. On the basis of the result of the evaluation a first concept of a performance measurement-system for order-picking will be developed by using typical key figures that are mentioned in academic literature. Finally, hints for a necessary detailed implementation and evaluation in practice will be given.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Indicators are widely used by organizations as a way of evaluating, measuring and classifying organizational performance. As part of performance evaluation systems, indicators are often shared or compared across internal sectors or with other organizations. However, indicators can be vague and imprecise, and also can lack semantics, making comparisons with other indicators difficult. Thus, this paper presents a knowledge model based on an ontology that may be used to represent indicators semantically and generically, dealing with the imprecision and vagueness, and thus facilitating better comparison. Semantic technologies are shown to be suitable for this solution, so that it could be able to represent complex data involved in indicators comparison.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Process-oriented motor competence (MC) assessments evaluate how a movement is performed. Product-oriented assessments evaluate the outcome of a movement. Determining the concurrent validity of process and product assessments is important to address the predictive utility of motor competence for health. The current study aimed to: (1) compare process and product assessments of the standing long jump, hop and throw across age groups and (2) determine the capacity of process assessments to classify levels of MC. Participants included 170 children classified into three age groups: 4–5, 7–8 and 10–11 years old. Participants’ skills were examined concurrently using three process assessments ((Test of Gross Motor Development-2nd edition [TGMD-2]), Get Skilled; Get Active, and developmental sequences) and one product measure (throw speed, jump and hop distance). Results indicate moderate to strong correlations between (1) process assessments across skills and age groups (r range = .37–70) and (2) process and product assessments across skills and age groups (r range = .26–.88). In general, sensitivity to detect advanced skill level is lowest for TGMD-2 and highest for developmental sequences for all three skills. The use of process and product assessments is suggested to comprehensively capture levels of MC in human movement.