941 resultados para Comparative performance


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current gold standard for the design of orthopaedic implants is 3D models of long bones obtained using computed tomography (CT). However, high-resolution CT imaging involves high radiation exposure, which limits its use in healthy human volunteers. Magnetic resonance imaging (MRI) is an attractive alternative for the scanning of healthy human volunteers for research purposes. Current limitations of MRI include difficulties of tissue segmentation within joints and long scanning times. In this work, we explore the possibility of overcoming these limitations through the use of MRI scanners operating at a higher field strength. We quantitatively compare the quality of anatomical MR images of long bones obtained at 1.5 T and 3 T and optimise the scanning protocol of 3 T MRI. FLASH images of the right leg of five human volunteers acquired at 1.5 T and 3 T were compared in terms of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). The comparison showed a relatively high CNR and SNR at 3 T for most regions of the femur and tibia, with the exception of the distal diaphyseal region of the femur and the mid diaphyseal region of the tibia. This was accompanied by an ~65% increase in the longitudinal spin relaxation time (T1) of the muscle at 3 T compared to 1.5 T. The results suggest that MRI at 3 T may be able to enhance the segmentability and potentially improve the accuracy of 3D anatomical models of long bones, compared to 1.5 T. We discuss how the total imaging times at 3 T can be kept short while maximising the CNR and SNR of the images obtained.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eighty six full-sib Corymbia F1 hybrid families (crosses between C. torelliana and four spotted gum taxa: C. citriodora subsp. variegata, C. citriodora subsp. citriodora, C. henryi and C. maculata), were planted in six trials across six disparate sites in south-eastern Queensland to evaluate their productivity and determine their potential utility for plantation forestry. In each trial, the best-growing 20% of hybrid families grew significantly faster (P=0.05) than open-pollinated seedlots of the parent species Corymbia citriodora subsp. variegata, ranging from 107% to 181% and 127% to 287% of the height and diameter respectively. Relative performance of hybrid families growing on more than one site displayed consistency in ranking for growth across sites and analysis showed low genotype-by-environment interaction. Heritability estimates based on female and male parents across two sites at age six years for height and diameter at breast height, were high (0.62±0.28 to 0.64±0.35 and 0.31±0.21 to 0.69±0.37 respectively), and low to moderate (0.03±0.04 to 0.33±0.22) for stem straightness, branch size, incidence of ramicorns, and frost and disease resistance traits at ages one to three years. The proportion of dominance variance for height and diameter had reduced to zero by age six years. Based on these promising results, further breeding and pilot-scale family forestry and clonal forestry deployment is being undertaken. These results have also provided insights regarding the choice of a future hybrid breeding strategy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article compares the performance of Fuzzy ARTMAP with that of Learned Vector Quantization and Back Propagation on a handwritten character recognition task. Training with Fuzzy ARTMAP to a fixed criterion used many fewer epochs. Voting with Fuzzy ARTMAP yielded the highest recognition rates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Mammography is known to be one of the most difficult radiographic exams to interpret. Mammography has important limitations, including the superposition of normal tissue that can obscure a mass, chance alignment of normal tissue to mimic a true lesion and the inability to derive volumetric information. It has been shown that stereomammography can overcome these deficiencies by showing that layers of normal tissue lay at different depths. If standard stereomammography (i.e., a single stereoscopic pair consisting of two projection images) can significantly improve lesion detection, how will multiview stereoscopy (MVS), where many projection images are used, compare to mammography? The aim of this study was to assess the relative performance of MVS compared to mammography for breast mass detection. METHODS: The MVS image sets consisted of the 25 raw projection images acquired over an arc of approximately 45 degrees using a Siemens prototype breast tomosynthesis system. The mammograms were acquired using a commercial Siemens FFDM system. The raw data were taken from both of these systems for 27 cases and realistic simulated mass lesions were added to duplicates of the 27 images at the same local contrast. The images with lesions (27 mammography and 27 MVS) and the images without lesions (27 mammography and 27 MVS) were then postprocessed to provide comparable and representative image appearance across the two modalities. All 108 image sets were shown to five full-time breast imaging radiologists in random order on a state-of-the-art stereoscopic display. The observers were asked to give a confidence rating for each image (0 for lesion definitely not present, 100 for lesion definitely present). The ratings were then compiled and processed using ROC and variance analysis. RESULTS: The mean AUC for the five observers was 0.614 +/- 0.055 for mammography and 0.778 +/- 0.052 for multiview stereoscopy. The difference of 0.164 +/- 0.065 was statistically significant with a p-value of 0.0148. CONCLUSIONS: The differences in the AUCs and the p-value suggest that multiview stereoscopy has a statistically significant advantage over mammography in the detection of simulated breast masses. This highlights the dominance of anatomical noise compared to quantum noise for breast mass detection. It also shows that significant lesion detection can be achieved with MVS without any of the artifacts associated with tomosynthesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last years, several solutions have been proposed to extend PROFIBUS in order to support wired and wireless network stations in the same network. In this paper we compare two of those solutions, one in which the interconnection between wired and wireless stations is made by repeaters and another in which the interconnection is made by bridges. The comparison is both qualitative and numerical, based on simulation models of both architectures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The design and fabrication of fiber based ammonia sensors employing Bromothymol blue and Chitosan as sensing elements are presented in this paper. In the presence of ammonia gas the absorption of Bromothymol blue changes while in the case of Chitosan the refractive index changes which in turn modulates the intensity of light propagating through a fiber.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since the first PFI hospital was established in 1994, many debates centred on the value for money and risk transfer in PFIs. Little concern is shown with PFI hospitals’ performance in delivering healthcare. Exploratory research was carried out to compare PFI with non‐PFI hospital performance. Five performance indicators were analysed to compare differences between PFI and non‐PFI hospitals, namely the length of waiting, the length of stay, MRSA infection rate, C difficile infection rate and patient experience. Data was collected from various government bodies. The results show that only some indexes measuring patient experience emerge statistically significant. This leads to a conclusion that PFI hospitals may not perform better than non‐PFI hospitals but they are not worse than non‐PFI hospitals in the delivery of services. However, future research needs to pay attention to reliability and validity of data sets currently available to undertake comparison.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Tropical Rainfall Measuring Mission 3B42 precipitation estimates are widely used in tropical regions for hydrometeorological research. Recently, version 7 of the product was released. Major revisions to the algorithm involve the radar refl ectivity - rainfall rates relationship, surface clutter detection over high terrain, a new reference database for the passive microwave algorithm, and a higher quality gauge analysis product for monthly bias correction. To assess the impacts of the improved algorithm, we compare the version 7 and the older version 6 product with data from 263 rain gauges in and around the northern Peruvian Andes. The region covers humid tropical rainforest, tropical mountains, and arid to humid coastal plains. We and that the version 7 product has a significantly lower bias and an improved representation of the rainfall distribution. We further evaluated the performance of versions 6 and 7 products as forcing data for hydrological modelling, by comparing the simulated and observed daily streamfl ow in 9 nested Amazon river basins. We find that the improvement in the precipitation estimation algorithm translates to an increase in the model Nash-Sutcliffe effciency, and a reduction in the percent bias between the observed and simulated flows by 30 to 95%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Genotyping of hepatitis C virus (HCV) has become an essential tool for prognosis and prediction of treatment duration. The aim of this study was to compare two HCV genotyping methods: reverse hybridization line probe assay (LiPA v.1) and partial sequencing of the NS5B region. Methods Plasma of 171 patients with chronic hepatitis C were screened using both a commercial method (LiPA HCV Versant, Siemens, Tarrytown, NY, USA) and different primers targeting the NS5B region for PCR amplification and sequencing analysis. Results Comparison of the HCV genotyping methods showed no difference in the classification at the genotype level. However, a total of 82/171 samples (47.9%) including misclassification, non-subtypable, discrepant and inconclusive results were not classified by LiPA at the subtype level but could be discriminated by NS5B sequencing. Of these samples, 34 samples of genotype 1a and 6 samples of genotype 1b were classified at the subtype level using sequencing of NS5B. Conclusions Sequence analysis of NS5B for genotyping HCV provides precise genotype and subtype identification and an accurate epidemiological representation of circulating viral strains.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper discusses the use of comparative performance measurement by means of Data Envelopment Analysis in the context of the regulation of English and Welsh water companies. Specifically, the use of Data Envelopment Analysis to estimate potential cost savings in sewerage is discussed as it fed into the price review of water companies carried out by the regulator of water companies in 1994. The application is used as a vehicle for highlighting generic issues in terms of assessing the impact of factors on the ranking of units on performance, the insights gained from using alternative methods to assess comparative performance, and the issue of assessing comparative performance when few in number but highly complex entities are involved. The paper should prove of interest to those interested in regulation and, more generally, in the use of methods of comparative performance measurement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The use of PHMB as a disinfectant in contact lens multipurpose solutions has been at the centre of much debate in recent times, particularly in relation to the issue of solution induced corneal staining. Clinical studies have been carried out which suggest different effects with individual contact lens materials used in combination with specific PHMB containing care regimes. There does not appear to be, however, a reliable analytical technique that would detect and quantify with any degree of accuracy the specific levels of PHMB that are taken up and released from individual solutions by the various contact lens materials. Methods: PHMB is a mixture of positively charged polymer units of varying molecular weight that has maximum absorbance wavelength of 236 nm. On the basis of these properties a range of assays including capillary electrophoresis, HPLC, a nickelnioxime colorimetric technique, mass spectrophotometry, UV spectroscopy and ion chromatography were assessed paying particular attention to each of their constraints and detection levels. Particular interest was focused on the relative advantage of contactless conductivity compared to UV and mass spectrometry detection in capillary electrophoresis (CE). This study provides an overview of the comparative performance of these techniques. Results: The UV absorbance of PHMB solutions, ranging from 0.0625 to 50 ppm was measured at 236 nm. Within this range the calibration curve appears to be linear however, absorption values below 1 ppm (0.0001%) were extremely difficult to reproduce. The concentration of PHMB in solutions is in the range of 0.0002–0.00005% and our investigations suggest that levels of PHMB below 0.0001% (levels encountered in uptake and release studies) can not be accurately estimated, in particular when analysing complex lens care solutions which can contain competitively absorbing, and thus interfering, species in the solution. The use of separative methodologies, such as CE using UV detection alone is similarly limited. Alternative techniques including contactless conductivity detection offer greater discrimination in complex solutions together with the opportunity for dual channel detection. Preliminary results achieved by TraceDec1 contactless conductivity detection, (Gain 150%, Offset 150) in conjunction with the Agilent capillary electrophoresis system using a bare fused silica capillary (extended light path, 50 mid, total length 64.5 cm, effective length 56 cm) and a cationic buffer at pH 3.2, exhibit great potential with reproducible PHMB split peaks. Conclusions: PHMB-based solutions are commonly associated with the potential to invoke corneal staining in combination with certain contact lens materials. However this terminology ‘PHMBbased solution’ is used primarily because PHMB itself has yet to be adequately implicated as the causative agent of the staining and compromised corneal cell integrity. The lack of well characterised adequately sensitive assays, coupled with the range of additional components that characterise individual care solutions pose a major barrier to the investigation of PHMB interactions in the lenswearing eye.