250 resultados para Comparability
Resumo:
The drive for comparability of financial information is to enable users to distinguish similarities and differences in economic activities for an entity over time and between entities so that their resource allocation decisions are facilitated. With the increased globalisation of economic activities, the enhanced international comparability of financial statements is often used as an argument to advance the convergence of local accounting standards to international financial reporting standards (IFRS). Differences in the underlying economic substance of transactions between jurisdictions plus accounting standards allowing alternative treatments may render this expectation of increased comparability unrealistic. Motivated by observations that, as a construct, comparability is under-researched and not well understood, we develop a comparability framework that distinguishes between four types of comparability. In applying this comparability framework to pension accounting in the Australian and USA contexts, we highlight a dilemma: while regulators seek to increase the likelihood that similar events are accounted for similarly, an unintended consequence may be that preparers are forced to apply similar accounting treatment to events that are, in substance, different.
Resumo:
In this paper we discuss the relationship and characterization of stochastic comparability, duality, and Feller–Reuter–Riley transition functions which are closely linked with each other for continuous time Markov chains. A necessary and sufficient condition for two Feller minimal transition functions to be stochastically comparable is given in terms of their density q-matrices only. Moreover, a necessary and sufficient condition under which a transition function is a dual for some stochastically monotone q-function is given in terms of, again, its density q-matrix. Finally, for a class of q-matrices, the necessary and sufficient condition for a transition function to be a Feller–Reuter–Riley transition function is also given.
Resumo:
A critical analysis of the public debate among German historians, philosophers and other intellectuals in the mid-1980s about the uniqueness or comparability of the Holocaust in relation to other instances of genocide.
Resumo:
Objective. The goal of this study was to check whether leakage results of the same specimens measured by 2 different leakage models are similar.Study design. Canine root canals were prepared and filled with cold gutta-percha cones and 1 of 4 sealers (20 canals for each sealer). The 80 specimens were first connected to a fluid transport model where air-bubble movement was measured. The same specimens were later connected to a glucose penetration model where the concentration of glucose was measured. In both models, a headspace pressure of 30 kPa was used to accelerate leakage.Results. In both models, 4 sealers ranked the same regarding the leakage they allowed, and a significant correlation between the results of the 2 models was confined (Spearman test coefficient = 0.65; P = .000001).Conclusion. Under the conditions of this study, leakage results of 80 specimens recorded in the fluid transport model and glucose penetration model were similar.
Resumo:
Incluye Bibliografía
Resumo:
Five test runs were performed to assess possible bias when performing the loss on ignition (LOI) method to estimate organic matter and carbonate content of lake sediments. An accurate and stable weight loss was achieved after 2 h of burning pure CaCO3 at 950 °C, whereas LOI of pure graphite at 530 °C showed a direct relation to sample size and exposure time, with only 40-70% of the possible weight loss reached after 2 h of exposure and smaller samples losing weight faster than larger ones. Experiments with a standardised lake sediment revealed a strong initial weight loss at 550 °C, but samples continued to lose weight at a slow rate at exposure of up to 64 h, which was likely the effect of loss of volatile salts, structural water of clay minerals or metal oxides, or of inorganic carbon after the initial burning of organic matter. A further test-run revealed that at 550 °C samples in the centre of the furnace lost more weight than marginal samples. At 950 °C this pattern was still apparent but the differences became negligible. Again, LOI was dependent on sample size. An analytical LOI quality control experiment including ten different laboratories was carried out using each laboratory's own LOI procedure as well as a standardised LOI procedure to analyse three different sediments. The range of LOI values between laboratories measured at 550 °C was generally larger when each laboratory used its own method than when using the standard method. This was similar for 950 °C, although the range of values tended to be smaller. The within-laboratory range of LOI measurements for a given sediment was generally small. Comparisons of the results of the individual and the standardised method suggest that there is a laboratory-specific pattern in the results, probably due to differences in laboratory equipment and/or handling that could not be eliminated by standardising the LOI procedure. Factors such as sample size, exposure time, position of samples in the furnace and the laboratory measuring affected LOI results, with LOI at 550 °C being more susceptible to these factors than LOI at 950 °C. We, therefore, recommend analysts to be consistent in the LOI method used in relation to the ignition temperatures, exposure times, and the sample size and to include information on these three parameters when referring to the method.