949 resultados para Compact fluorescent lamp


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposes a way to quantify the emissions of mercury (Hg) and CO2 associated with the manufacture and operation of compact fluorescent lamps with integrated ballasts (CFLis), as well as the economic cost of using them under different operating cycles. The main purpose of this paper is to find simple criteria for reducing the polluting emissions under consideration and the economic cost of CFLi to a minimum. A lifetime model is proposed that allows the emissions and costs to be described as a function of degradation from turning CFLi on and their continuous operation. An idealized model of a CFLi is defined that combines characteristics stated by different manufacturers. In addition, two CFLi models representing poor-quality products are analyzed. It was found that the emissions and costs per unit of time of operation of the CFLi depend linearly on the number of times per unit of time it is turned on and the time of continuous operation. The optimal conditions (lowest emissions and costs) depend on the place of manufacture, the place of operation and the quality of the components of the lamp/ballast. Finally, it was also found that for each lamp, there are intervals when it is turned off during which emissions of pollutants and costs are identical regardless of how often the lamp is turned on or the time it remains on. For CO2 emissions, the lamp must be off up to 5 minutes; for the cost, up to 7 minutes and for Hg emissions, up to 43 minutes. It is advisable not to turn on a CFLi sooner than 43 minutes from the last time it was turned off.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An electronic ballast for multiple tubular fluorescent lamp systems is presented. The proposed structure has a high value for the power factor, a dimming capability, and soft switching of the semiconductor devices operated at high frequencies. A zero-current switching pulse width modulated SEPIC converter is used as the rectifying stage and it is controlled using the instantaneous average input current technique. The inverting stage consists of classical resonant half-bridge converter with series-resonant parallel-loaded filters. The dimming control technique is based on varying the switching frequency and monitoring the phase shift of the current drained by the filters and lamps in order to establish a closed loop control. Experimental results are presented that validate the theoretical analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a new methodology for the determination of fluorescent lamp models based on equivalent resistances. One important feature of the proposed methodology is concerned with the inclusion of the filaments into the model, considering the effects of dimming operation on the equivalent resistances. The classical Series-Resonant Parallel-Loaded Half-Bridge inverter is used as the power stage of the ballast. Moreover, the variation of the inverter's switching frequency is the dimming technique assumed for the analyses. Results obtained with a F32T8 lamp indicate that the accuracy of the model is very satisfactory. Thus, the lamp models obtained with the proposed methodology have the potential to serve as an important tool for ballast designers, considering the necessity for evaluating the lamp/ballast compatibility, according to issues concerned to the operating conditions of the electrodes' filaments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para a obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Automação e Electrónica Industrial

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hehkulamput tullaan kieltämään Euroopan Unionin alueella vuoden 2016 syyskuuhun mennessä. Hehkulamput korvataan suurimmaksi osaksi pienloistelampuilla, jotka omaavat hehkulamppuihin verrattuna paremman hyötysuhteen. Pienloistelamput aiheuttavat kuitenkin häiriöitä niitä syöttävään sähköverkkoon. Tässä kandidaatin työssä mitattiin 15 erilaisen pienloistelampun aiheuttamat johtuvat RF-taajuiset häiriöt. Tuloksia verrattiin CISPR 15 – standardissa esitettyihin raja-arvoihin, joita pienloistelamppujen tulisi noudattaa. Mittaukset suoritettiin käyttämällä CISPR 16 –standardin kanssa yhteensopivaa mittavastaanotinta (Rohde & Schwarz ESHS30) sekä myöskin CISPR 16 yhteensopivaa keinoverkkoa (Rohde & Schwarz ESH2Z5). Lamput mitattiin CISPR 15 –standardin mukaisesti, muutamia poikkeuksia lukuun ottamatta. Lamppuja ei mitattu käyttämällä CISPR 15 –standardissa vaadittua lampun pidintä. Eikä lamppuja myöskään esikäytetty ollenkaan. Lukuun ottamatta yhtä pienloistelamppua, kaikki jäivät raja-arvon alapuolelle. Rajan ylittäneen lampun tulos tosin mahtuu mittavastaanottimen mittavirheeseen. Joten kyseessä ei ollut suuren suuri ylitys. Muiden tutkittujen pienloistelamppujen johtuvat RF-häiriöt ovat hyväksyttävällä tasolla ja ne tuskin tulevat aiheuttamaan ongelmia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With the imposition of the suspension of production and subsequent banning of incandescent light bulbs will be necessary to replace it by other more energy-efficient. Although the main alternative is the compact fluorescent lamp, the environmental impact caused by it due to incorrect disposal and the amount of harmonics included in the network resulting in losses related to the quality of electric power system makes them sought new alternatives for lighting systems that are efficient and have low environmental impact. In this context, the LED (Lighting Emitting Diode), based on solid-state components, is presented as an option for new projects and replacement of existing lighting. In this work we studied aspects of energy, environmental and economic impacts of a possible replacement of conventional lighting systems for new technology. From laboratory tests and surveys of the costs of different types of lamps used for residential lighting, we performed a comparative analysis considering energy and economic aspects which showed that the LED technology, but has a high initial investment, it is best when power quality and environmental preservation are relevant factors in decision making for the choice of technology to be used in the lighting system

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many species of insects display a disposition to move towards light. As a consequence, nocturnal artificial lighting often contributes to an increase in insect population among humans. We tested the hypothesis that residential white lamps can evoke significantly different attraction to insects even when their light outputs are nearly indistinguishable to humans. In a two-choice experiment using insect traps equipped with either a compact fluorescent or a LED light source with similar photometric specifications, about three times more insects were captured in the trap with a compact fluorescent lamp than in the LED trap. The results suggest that LED lamps are preferable to compact fluorescent lamps when the objective is to avoid attracting nocturnal insects to households.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A literature review revealed that very little work has been conducted to investigate the possible benefits of coloured interventions on reading performance in low vision due to ARMD, under conditions that are similar to the real world reading environment. Further studies on the use of colour, as a rehabilitative intervention in low vision would therefore be useful. A series of objective, subject based, age-similar controlled experiments were used to address the primary aims. Trends in some of the ARMD data suggested better reading performance with blue or green illuminance but there were also some individuals who performed better with yellow, or with illuminance of reduced intensity. Statistically, better reading in general occurred with a specialised yellow photochromic lens and also a clear lens than with a fixed lens or a neutral density filter. No reading advantage was gained from using the coloured screen facility of a video-magnifier. Some subjects with low vision were found to have co-existent binocular vision anomalies, which may have caused reading difficulties similar to those produced by ARMD. Some individuals with ARMD benefited from the use of increased local illuminance produced by either a standard tungsten or compact fluorescent lamp. No reading improvement occurred with a daylight simulation tungsten lamp. The Intuitive Colorimeter® can be used to detect and map out colour vision discrimination deficiency in ARMD and the Humphrey 630 Visual Field Analyser can be used to analyse the biocular visual field in subjects with ARMD. Some experiments highlighted a positive effect of a blue intervention in reading with ARMD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an improved design methodology for determining the parameters used in the classical Series-Parallel Loaded Resonant (SPLR) filter employed in the switching frequency controlled dimmable electronic ballasts. According to the analysis developed in this paper, it is possible to evaluate some characteristics of the resonant filter during the dimming process, such as: range of switching frequency, phase shift and rms value of the current drained by the resonant filter + fluorescent lamp set.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an improved design methodology for the determination of the parameters used in the classical series-resonant parallel-loaded (SRPL) filter employed in the switching frequency controlled dimmable electronic ballasts. According to the analysis developed in this paper, it is possible to evaluate some important characteristics of the resonant filter during the dimming operation, such as: range of switching frequency, phase shift, and rms value of the current drained by the resonant filter + fluorescent lamp set. Experimental results are presented in order to validate the analyses developed in this paper. © 2005 IEEE.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

ABSTRACT Broiler poultry is highly dependent on artificial lightening. Power consumption costs of artificial lighting systems is the second largest expense related to broiler industry, second only to feed expenses. Therefore, the current study focused to analyze technical and economic feasibility of replacing incandescent lamps already used in aviaries with other lamp types. Costs related to power consumption, implementation and maintenance of the lighting systems were evaluated with the aid of financial mathematics using net present value, return over investment and payback. Systems composed of six lamp types were analyzed in two different configurations to meet the minimum illuminance of 5 and 20 lux and for use in conventional sheds and dark house. The lamps tested were incandescent (LI) of 100 W, compact fluorescent (CFL) of 34 W, mixed (ML) 160 W sodium vapor (SVL) of 70 W, tubular fluorescent T8 (TFL T8) of 40 W and tubular fluorescent T5 (TFL T5) of 28 W. For the systems tested, it was found that the tubular fluorescent lamps T8 and T5 showed the best results of technical and economic feasibility.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Euroopan Unioni kieltää matalan hyötysuhteen lamppujen käyttämisen sekä sisä- että ulkovalaisimissa. Näin ollen matalan hyötysuhteen lamput, kuten perinteiset hehkulamput tulee vaihtaa paremman hyötysuhteen lamppuihin, kuten energiansäästölamppuihin. Energiansäästölampuissa 230 V, 50 Hz verkkosähkö muunnetaan valonlähteelle sopivaksi tehoelektroniikan avulla. 50 Hz perustaajuisen virran lisäksi energiansäästölamput ottavat verkosta harmonisia yliaaltoja. Harmoniset yliaallot aiheuttavat lisähäviöitä verkostokomponenteissa, kuten muuntajissa ja johdoissa. Tässä kandidaatintyössä tutkitaan millaisia vaikutuksia hehkulamppujen vaihtaminen energiansäästölamppuihin aiheuttaa pienjännitteisessä jakeluverkossa. Työssä tarkastellaan lyhyesti myös energiansäästölamppujen energiatehokkuutta, sekä sitä, millaisia rajoitteita standardit asettavat harmonisille yliaalloille.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents a new static model for tubular fluorescent lamps (T12 bulb) operated at high frequencies. The main goal of this paper is to investigate the effects of ambient temperature and nominal switching frequency of operation in the static characteristics of tubular fluorescent lamps. The methodology for obtaining the model is based on several two-dimensional mathematical regressions, used to provide the behavior of the fluorescent lamp according to different independent variables, namely: power processed through the lamp and ambient temperature. In addition, the proposed model can be easily converted to a lamp equivalent resistance model, which can be useful for ballast designers. Finally, the curves obtained using the new model are compared to the correspondent experimental data, in order to verify the accuracy of the proposed methodology.