992 resultados para Common mode


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A linearly tunable low-voltage CMOS transconductor featuring a new adaptative-bias mechanism that considerably improves the stability of the processed-signal common,mode voltage over the tuning range, critical for very-low voltage applications, is introduced. It embeds a feedback loop that holds input devices on triode region while boosting the output resistance. Analysis of the integrator frequency response gives an insight into the location of secondary poles and zeros as function of design parameters. A third-order low-pass Cauer filter employing the proposed transconductor was designed and integrated on a 0.8-mum n-well CMOS standard process. For a 1.8-V supply, filter characterization revealed f(p) = 0.93 MHz, f(s) = 1.82 MHz, A(min) = 44.08, dB, and A(max) = 0.64 dB at nominal tuning. Mined by a de voltage V-TUNE, the filter bandwidth was linearly adjusted at a rate of 11.48 kHz/mV over nearly one frequency decade. A maximum 13-mV deviation on the common-mode voltage at the filter output was measured over the interval 25 mV less than or equal to V-TUNE less than or equal to 200 mV. For V-out = 300 mV(pp) and V-TUNE = 100 mV, THD was -55.4 dB. Noise spectral density was 0.84 muV/Hz(1/2) @1 kHz and S/N = 41 dB @ V-out = 300 mV(pp) and 1-MHz bandwidth. Idle power consumption was 1.73 mW @V-TUNE = 100 mV. A tradeoff between dynamic range, bandwidth, power consumption, and chip area has then been achieved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a new open-winding control strategy is proposed for a brushless doubly-fed reluctance generator (BDFRG) applicable for wind turbines. The BDFRG control winding is fed via a dual two-level three-phase converter using a single dc bus. Direct power control based on maximum power point tracking with common mode voltage elimination is designed, which not only the active and reactive power is decoupled, but the reliability and redundancy are all improved greatly by increasing the switching modes of operation, while DC-link voltage and rating of power devices decreased by 50% comparing to the traditional three-level converter systems. Consequently its effectiveness is evaluated by simulation tests based on a 42-kW prototype generator.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: The giant Lausannevirus was recently identified as a parasite of amoeba that replicates rapidly in these professional phagocytes. This study aimed at assessing Lausannevirus seroprevalence among asymptomatic young men in Switzerland and hopefully identifying possible sources of contact with this giant virus. Methods: The presence of anti-Lausannevirus antibodies was assessed in sera from 517 asymptomatic volunteers who filled a detailed questionnaire. The coreactivity between Lausannevirus and amoeba-resisting bacteria was assessed. Results: Lausannevirus prevalence ranged from 1.74 to 2.51%. Sporadic condom use or multiple sexual partners, although frequent (53.97 and 60.35%, respectively), were not associated with anti-Lausannevirus antibodies. On the contrary, frequent outdoor sport practice as well as milk consumption were significantly associated with positive Lausannevirus serologies (p = 0.0066 and 0.028, respectively). Coreactivity analyses revealed an association between Criblamydia sequanensis (an amoeba-resisting bacterium present in water environments) and Lausannevirus seropositivity (p = 0.001). Conclusions: Lausannevirus seroprevalence is low in asymptomatic Swiss men. However, the association between virus seropositivity and frequent sport practice suggests that this member of the Megavirales may be transmitted by aerosols and/or exposure to specific outdoor environments. Milk intake was also associated with seropositivity. Whether the coreactivity observed for C. sequanensis and Lausannevirus reflects a common mode of acquisition or some unexpected cross-reactivity remains to be determined. © 2013 S. Karger AG, Basel.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Human infection with the protozoa Trypanosoma cruzi extends through North, Central, and South America, affecting 21 countries. Most human infections in the Western Hemisphere occur through contact with infected bloodsucking insects of the triatomine species. As T. cruzi can be detected in the blood of untreated infected individuals, decades after infection took place; the infection can be also transmitted through blood transfusion and organ transplant, which is considered the second most common mode of transmission for T. cruzi. The third mode of transmission is congenital infection. Economic hardship, political problems, or both, have spurred migration from Chagas endemic countries to developed countries. The main destination of this immigration is Australia, Canada, Spain, and the United States. In fact, human infection through blood or organ transplantation, as well as confirmed or potential cases of congenital infections has been described in Spain and in the United States. Estimates reported here indicates that in Australia in 2005-2006, 1067 of the 65,255 Latin American immigrants (16 per 1000) may be infected with T. cruzi, and in Canada, in 2001, 1218 of the 131,135 immigrants (9 per 1000) whose country of origin was identified may have been also infected. In Spain, a magnet for Latin American immigrants since the 2000, 5125 of 241,866 legal immigrants in 2003 (25 per 1000), could be infected. In the United States, 56,028 to 357,205 of the 7,20 million, legal immigrants (8 to 50 per 1000), depending on the scenario, from the period 1981-2005 may be infected with T. cruzi. On the other hand, 33,193 to 336,097 of the estimated 5,6 million undocumented immigrants in 2000 (6 to 59 per 1000) could be infected. Non endemic countries receiving immigrants from the endemic ones should develop policies to protect organ recipients from T. cruzi infection, prevent tainting the blood supply with T. cruzi, and implement secondary prevention of congenital Chagas disease.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Retroperitoneal fibrosis (RF) is a rare disease, typically with an insidious clinical course. The peak incidence is seen in patients 40 to 60 years of age and mostly in man. The characteristic finding in this disease is a periaortic fibrous mass that often surrounds the ureters. Although usually regarded as an obstructive uropathy, there has been growing recognition of the condition as a generalized disease. It may have a wide variety of manifestations including mediastinitis, thyroiditis and sclerosing cholangitis. The most common mode of presentation remains abdominal or flank pain with uremia, anemia and a high sedimentation rate. Although ultrasound and renal scintigraphy may contribute to the general evaluation of patients with RF, CT-scanner is the preferred imaging method. The multiplanar imaging capability of magnetic resonance may facilitate assessment of disease extent. The pathogenesis of the disease remains unknown. Steroids and, more recently tamoxifen, appear to be effective in the treatment of the RF. In most instances, RF does not lead to long-term morbidity or affect survival. The three cases of RF reported herein illustrate the varied mode of presentation and the response to the treatment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Peroxisome proliferator activated receptors are ligand activated transcription factors belonging to the nuclear hormone receptor superfamily. Three cDNAs encoding such receptors have been isolated from Xenopus laevis (xPPAR alpha, beta, and gamma). Furthermore, the gene coding for xPPAR beta has been cloned, thus being the first member of this subfamily whose genomic organization has been solved. Functionally, xPPAR alpha as well as its mouse and rat homologs are thought to play an important role in lipid metabolism due to their ability to activate transcription of a reporter gene through the promoter of the acyl-CoA oxidase (ACO) gene. ACO catalyzes the rate limiting step in the peroxisomal beta-oxidation of fatty acids. Activation is achieved by the binding of xPPAR alpha on a regulatory element (DR1) found in the promoter region of this gene, xPPAR beta and gamma are also able to recognize the same type of element and are, as PPAR alpha, able to form heterodimers with retinoid X receptor. All three xPPARs appear to be activated by synthetic peroxisome proliferators as well as by naturally occurring fatty acids, suggesting that a common mode of action exists for all the members of this subfamily of nuclear hormone receptors.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tässädiplomityössä selvitettiin taajuusmuuttajan synnyttämien yhteismuotoisten häiriöiden syntyä, ominaisuuksia, kulkureittejä sekä erilaisia tekniikoita toteuttaa yhteismuotosuodatus taajuusmuuttajan lähdössä. Työssä suunniteltiin ja mitoitettiin yhteismuotosuodatin, josta valmistettiin prototyyppi. Suodatinta testattiin laboratoriossa ja mittauksissa käytettiin erilaisia suodattimen kapasitanssin arvoja ja neutraalin pisteen kytkennän variaatioita. Mittauksilla selvitettiin suodattimen kyky suodattaa myös yhteismuotoisten jännitteiden lisäksi eromuotoista jännitettä, akselijännitettä ja vaihevirtaa. Mittaustulosten perusteella voitiin todeta suunnitellun suodattimen parantavan merkittävästi taajuusmuuttajalta moottorille syötettävän sähkön laatua ja loiventavan ennen kaikkea yhteismuotoisen jännitepulssin nousureunaa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The work aims to analyze the possibilities of utilizing old crane driving AC induction motors in modern pulse-width-modulated variable frequency drives. Bearing currents and voltage stresses are the two main problems associated with modern IGBT inverters, and they may cause premature failure of an old induction motor. The origins of these two problems are studied. An analysis of the mechanism of bearing failure is proposed. Certain types of bearing currents are considered in detail. The most effective and economical means are chosen for bearing currents mitigation. Transient phenomena of cables and mechanism of over voltages occurring at motor terminals are studied in the work. The weakest places of the stator winding insulation system are shown and recommendations are given considering the mitigation of voltage stresses. Only the most appropriate and cost effective preventative methods are chosen for old motor drives. Rewinding of old motors is also considered.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Power electronic converter drives use, for the sake of high efficiency, pulse-width modulation that results in sequences of high-voltage high-frequency steep-edged pulses. Such a signal contains a set of high harmonics not required for control purposes. Harmonics cause reflections in the cable between the motor and the inverter leading to faster winding insulation ageing. Bearing failures and problems with electromagnetic compatibility may also result. Electrical du/dt filters provide an effective solution to problems caused by pulse-width modulation, thereby increasing the performance and service life of the electrical machines. It is shown that RLC filters effectively decrease the reflection phenomena in the cable. Improved (simple, but effective) solutions are found for both differential- and common-mode signals; these solutions use a galvanic connection between the RLC filter star point and the converter DC link. Foil chokes and film capacitors are among the most widely used components in high-power applications. In actual applications they can be placed in different parts of the cabinet. This fact complicates the arrangement of the cabinet and decreases the reliability of the system. In addition, the inductances of connection wires may prevent filtration at high frequencies. This thesis introduces a new hybrid LC filter that uses a natural capacitance between the turns of the foil choke based on integration of an auxiliary layer into it. The main idea of the hybrid LC filter results from the fact that both the foil choke and the film capacitors have the same roll structure. Moreover, the capacitance between the turns (“intra capacitance”) of the foil inductors is the reason for the deterioration of their properties at high frequencies. It is shown that the proposed filter has a natural cancellation of the intra capacitance. A hybrid LC filter may contain two or more foil layers isolated from each other and coiled on a core. The core material can be iron or even air as in the filter considered in this work. One of the foils, called the main foil, can be placed between the inverter and the motor cable. Other ones, called auxiliary foils, may be connected in star to create differential-mode noise paths, and then coupled to the DC link midpoint to guarantee a traveling path, especially for the common-mode currents. This way, there is a remarkable capacitance between the main foil and the auxiliary foil. Investigations showed that such a system can be described by a simple equivalent LC filter in a wide range of frequencies. Because of its simple hybrid construction, the proposed LC filter can be a cost-effective and competitive solution for modern power drives. In the thesis, the application field of the proposed filter is considered and determined. The basics of hybrid LC filter design are developed further. High-frequency behaviour of the proposed filter is analysed by simulations. Finally, the thesis presents experimental data proving that the hybrid LC filter can be used for du/dt of PWM pulses and reduction of common-mode currents.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The maximum realizable power throughput of power electronic converters may be limited or constrained by technical or economical considerations. One solution to this problemis to connect several power converter units in parallel. The parallel connection can be used to increase the current carrying capacity of the overall system beyond the ratings of individual power converter units. Thus, it is possible to use several lower-power converter units, produced in large quantities, as building blocks to construct high-power converters in a modular manner. High-power converters realized by using parallel connection are needed for example in multimegawatt wind power generation systems. Parallel connection of power converter units is also required in emerging applications such as photovoltaic and fuel cell power conversion. The parallel operation of power converter units is not, however, problem free. This is because parallel-operating units are subject to overcurrent stresses, which are caused by unequal load current sharing or currents that flow between the units. Commonly, the term ’circulatingcurrent’ is used to describe both the unequal load current sharing and the currents flowing between the units. Circulating currents, again, are caused by component tolerances and asynchronous operation of the parallel units. Parallel-operating units are also subject to stresses caused by unequal thermal stress distribution. Both of these problemscan, nevertheless, be handled with a proper circulating current control. To design an effective circulating current control system, we need information about circulating current dynamics. The dynamics of the circulating currents can be investigated by developing appropriate mathematical models. In this dissertation, circulating current models aredeveloped for two different types of parallel two-level three-phase inverter configurations. Themodels, which are developed for an arbitrary number of parallel units, provide a framework for analyzing circulating current generation mechanisms and developing circulating current control systems. In addition to developing circulating current models, modulation of parallel inverters is considered. It is illustrated that depending on the parallel inverter configuration and the modulation method applied, common-mode circulating currents may be excited as a consequence of the differential-mode circulating current control. To prevent the common-mode circulating currents that are caused by the modulation, a dual modulator method is introduced. The dual modulator basically consists of two independently operating modulators, the outputs of which eventually constitute the switching commands of the inverter. The two independently operating modulators are referred to as primary and secondary modulators. In its intended usage, the same voltage vector is fed to the primary modulators of each parallel unit, and the inputs of the secondary modulators are obtained from the circulating current controllers. To ensure that voltage commands obtained from the circulating current controllers are realizable, it must be guaranteed that the inverter is not driven into saturation by the primary modulator. The inverter saturation can be prevented by limiting the inputs of the primary and secondary modulators. Because of this, also a limitation algorithm is proposed. The operation of both the proposed dual modulator and the limitation algorithm is verified experimentally.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this thesis, analysis of electromagnetic compatibility of high-power photovoltaic solar plant is made. Current standards suitable for photovoltaic applications are given. Measurements of antenna factor for experimental setup are shown. Also, measurements of common mode disturbance voltages in high-power solar plant are given. Importance of DC-side filter is shown. In the last part of the work, electromagnetic simulations are made. These simulations show influence of several factors to EMC of power plant. Based on these simulations and measurements recommendations are given.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Työssä tutkitaan pienitehoisen monimoottoritaajuusmuuttajakäytön yhteismuotovirtojen aiheuttamia ongelmia. Työn tavoitteena on muodostaa monimoottorikäyttöjen toteuttajille opastus, jonka avulla sähkökäytön suunnittelun alkuvaiheessa voidaan ottaa huomioon monimoottorikäytön erikoistarpeita. Työn teoriaosuudessa esitellään taajuusmuuttajan vaihtosuuntaustekniikan aiheuttamia ongelmia, moottorikaapelin mallintamista ja vertaillaan ongelmien ratkaisukeinoja pienitehoisten taajuusmuuttajien näkökulmasta. Yhteismuotoista virtaa tutkitaan mittaamalla rakennetulla monimoottorikäytöllä sekä simuloimalla vaihdellen kaapelin pituutta ja moottorien lukumäärää. Mittaamalla vertaillaan myös virran suodatusratkaisuja. Muodostettu simulointimalli on hyvin yksinkertainen ja luotettavammat virta-arvot saadaankin mittauksella. Kuitenkin työn perusteella voidaan antaa ohjeita monimoottorikäytön suunnittelulle. Esimerkiksi jokaiselle moottorille täytyy suunnitella erillinen suojaus ja taajuusmuuttaja on syytä mitoittaa todellisen kuormavirran mukaan. Yhteismuotoisen virran aiheuttamat ongelmat ovat sitä pienempiä, mitä vähemmän moottoreita on rinnakkain ja mitä lyhyempi moottorikaapelien yhteispituus on.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fuel cells are a promising alternative for clean and efficient energy production. A fuel cell is probably the most demanding of all distributed generation power sources. It resembles a solar cell in many ways, but sets strict limits to current ripple, common mode voltages and load variations. The typically low output voltage from the fuel cell stack needs to be boosted to a higher voltage level for grid interfacing. Due to the high electrical efficiency of the fuel cell, there is a need for high efficiency power converters, and in the case of low voltage, high current and galvanic isolation, the implementation of such converters is not a trivial task. This thesis presents galvanically isolated DC-DC converter topologies that have favorable characteristics for fuel cell usage and reviews the topologies from the viewpoint of electrical efficiency and cost efficiency. The focus is on evaluating the design issues when considering a single converter module having large current stresses. The dominating loss mechanism in low voltage, high current applications is conduction losses. In the case of MOSFETs, the conduction losses can be efficiently reduced by paralleling, but in the case of diodes, the effectiveness of paralleling depends strongly on the semiconductor material, diode parameters and output configuration. The transformer winding losses can be a major source of losses if the windings are not optimized according to the topology and the operating conditions. Transformer prototyping can be expensive and time consuming, and thus it is preferable to utilize various calculation methods during the design process in order to evaluate the performance of the transformer. This thesis reviews calculation methods for solid wire, litz wire and copper foil winding losses, and in order to evaluate the applicability of the methods, the calculations are compared against measurements and FEM simulations. By selecting a proper calculation method for each winding type, the winding losses can be predicted quite accurately before actually constructing the transformer. The transformer leakage inductance, the amount of which can also be calculated with reasonable accuracy, has a significant impact on the semiconductor switching losses. Therefore, the leakage inductance effects should also be taken into account when considering the overall efficiency of the converter. It is demonstrated in this thesis that although there are some distinctive differences in the loss distributions between the converter topologies, the differences in the overall efficiency can remain within a range of a few percentage points. However, the optimization effort required in order to achieve the high efficiencies is quite different in each topology. In the presence of practical constraints such as manufacturing complexity or cost, the question of topology selection can become crucial.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pulssinleveysmoduloidun vaihtosuuntaajan hyötysuhteen parantaminen ja kytkentätaajuuden suurentaminen ovat johtaneet lähtöjännitteen suuritaajuiseen taajuussisältöön kaksitasoisessa, jännitevälipiirillisessä taajuusmuuttajatopologiassa. Kasvava tarve siirtää tehoa myös verkkoon päin on lisännyt aktiivisen verkkosillan käyttöä. Kaksitasoisen aktiivisen verkkosillan vaikutuksesta DC-välipiirin keskipisteen ja kolmivaiheisen kuorman tähtipisteen välinen jännite on nollasta poikkeava aiheuttaen suurentuneen yhteismuotoisen jännitteen taajuusmuuttajan lähtöön ja verkon puolelle. Lisäksi yhteismuotoisten jännitteiden aiheuttamat kytkentätaajuiset häiriövirrat voivat aiheuttaa vikavirtasuojien tahatonta laukeamista, vaikeuttaa EMC-standardien vaatimusten täyttämistä, lisätä moottorin käämieristyksien rasitusta ja mahdollisuutta moottorin laakerivaurioille. Diplomityössä tutkitaan aktiivisen ja passiivisen verkkosillan tuottamaa yhteismuotoista jännitettä simuloinneilla. Esitellään aikaisempaa tutkimustietoa yhteismuotoisen jännitteen ja virran vaimennusratkaisuista aktiivista verkkosiltaa käytettäessä. Tutkimustiedon pohjalta suunnitellaan koelaitteistolle soveltuva suodin. Suotimen toiminta testataan simuloinnein sekä kokeellisin mittauksin. Tehdyt mittaukset osoittavat, että suunniteltu suodin vaimentaa yhteismuotoista jännitettä noin 20 dB verkkosillan kytkentätaajuudella ja tämän jälkeen yli 20 dB/dekadi taajuuteen 100 kHz asti. Lisäksi yhteismuotoisen virran suuruus syöttökaapelin kautta pieneni ehdotetun suotimen vaikutuksesta.