997 resultados para Commercial losses


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electric power networks, namely distribution networks, have been suffering several changes during the last years due to changes in the power systems operation, towards the implementation of smart grids. Several approaches to the operation of the resources have been introduced, as the case of demand response, making use of the new capabilities of the smart grids. In the initial levels of the smart grids implementation reduced amounts of data are generated, namely consumption data. The methodology proposed in the present paper makes use of demand response consumers’ performance evaluation methods to determine the expected consumption for a given consumer. Then, potential commercial losses are identified using monthly historic consumption data. Real consumption data is used in the case study to demonstrate the application of the proposed method.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The electric utilities have large revenue losses annually due to commercial losses, which are caused mainly by fraud on the part of consumers and faulty meters. Automatic detection of such losses where there is a complex problem, given the large number of consumers and the high cost of each inspection, not to mention the wear of the relationship between company and consumer. Given the above, this paper aims to briefly present some methodologies applied by utilities to identify consumer frauds.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Nowadays, fraud detection is important to avoid nontechnical energy losses. Various electric companies around the world have been faced with such losses, mainly from industrial and commercial consumers. This problem has traditionally been dealt with using artificial intelligence techniques, although their use can result in difficulties such as a high computational burden in the training phase and problems with parameter optimization. A recently-developed pattern recognition technique called optimum-path forest (OPF), however, has been shown to be superior to state-of-the-art artificial intelligence techniques. In this paper, we proposed to use OPF for nontechnical losses detection, as well as to apply its learning and pruning algorithms to this purpose. Comparisons against neural networks and other techniques demonstrated the robustness of the OPF with respect to commercial losses automatic identification.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Esta dissertação de mestrado tem como finalidade analisar a gestão das perdas não técnicas de energia elétrica e entender as metodologias adotadas nos projeto de combate a essas perdas desenvolvidas pelas concessionárias de distribuição. Trazendo, assim, à superfície, a importância de uma gestão eficiente das perdas comerciais para se obter uma boa manutenção dos seus índices. É no sistema de distribuição de energia onde ocorre a maior porcentagem das perdas dos sistemas elétricos de potência. Sendo, portanto, a parte do sistema elétrico com maior potencial para redução das perdas. Assim, o enfoque desta dissertação é fazer uma análise das perdas não técnicas, das formas de atuação sobre elas e das metodologias utilizadas pelas concessionárias atualmente, as quais serão apresentadas através de um estudo de caso.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Various pellet heating systems are marketed in Sweden, some of them in combination with a solar heating system. Several types of pellet heating units are available and can be used for a combined system. This article compares four typical combined solar and pellet heating systems: System 1 and 2 two with a pellet stove, system 3 with a store integrated pellet burner and system 4 with a pellet boiler. The lower efficiency of pellet heaters compared to oil or gas heaters increases the primary energy demand. Consequently heat losses of the various systems have been studied. The systems have been modeled in TRNSYS and simulated with parameters identified from measurements. For almost all systems the flue gas losses are the main heat losses except for system 3 where store heat losses prevail. Relevant are also the heat losses of the burner and the boiler to the ambient. Significant leakage losses are noticed for system 3 and 4. For buildings with an open internal design system 1 is the most efficient solution. Other buildings should preferably apply system 3. The right choice of the system depends also on whether the heater is placed inside or outside of the heated are. A large potential for system optimization exist for all studied systems, which when applied could alter the relative merits of the different system types.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Acidic soft drinks are potentially erosive for dental hard tissues. This in vitro study evaluated the effect of calcium, fluoride, iron and phosphate, supplemented alone or in combination to a commercial citric acid-based carbonated beverage on dental erosion. Ninety enamel samples (4 x 4 x 3 mm) were randomly allocated to nine groups (n = 10): G1 - pure beverage (control); G2 - with 1 mM Ca; G3 - with 0.047 mM F; G4 - with 1 mM Fe; G5 - with 1 mM P; G6 - with 1 mM Ca and 0.047 mM F; G7 - with 1 mM Ca and 1 mM P; G8 - with 1 mM Fe and 0.047 mM F; and G9 - with 1 mM Ca, 1 mM P, 0.047 mM F and 1.0 mM Fe. The samples were subjected to six pH cycles over a 24-h period. In each cycle, the samples were immersed in pure or modified beverage (1 min) and in artificial saliva (59 min). During the remaining period (18 h), the samples were maintained in artificial saliva. Enamel loss was assessed by profilometry (mm). Data were tested using ANOVA and Tukey`s tests (p < 0.05). Highest enamel losses were observed in the control group (G1) and in the groups containing Fe (G4 and G8). The groups containing Ca (G2 and G6) showed significantly less wear compared to control. In conclusion, the modification of an erosive soft drink with low concentrations of Ca with or without F may reduced its erosive potential.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Combined positron emission tomography and computed tomography (PET/CT) scanners play a major role in medicine for in vivo imaging in an increasing number of diseases in oncology, cardiology, neurology, and psychiatry. With the advent of short-lived radioisotopes other than 18F and newer scanners, there is a need to optimize radioisotope activity and acquisition protocols, as well as to compare scanner performances on an objective basis. The Discovery-LS (D-LS) was among the first clinical PET/CT scanners to be developed and has been extensively characterized with older National Electrical Manufacturer Association (NEMA) NU 2-1994 standards. At the time of publication of the latest version of the standards (NU 2-2001) that have been adapted for whole-body imaging under clinical conditions, more recent models from the same manufacturer, i.e., Discovery-ST (D-ST) and Discovery-STE (D-STE), were commercially available. We report on the full characterization both in the two- and three-dimensional acquisition mode of the D-LS according to latest NEMA NU 2-2001 standards (spatial resolution, sensitivity, count rate performance, accuracy of count losses, and random coincidence correction and image quality), as well as a detailed comparison with the newer D-ST widely used and whose characteristics are already published.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this work is to improve the thermal performance of commercial freezers using phase change materials (PCM) and the prove the importance of the correct PCM selection (melting temperature) for each application. To do this a vertical freezer with and without macro encapsulation PCM are used to assess the benefits of using PCM in minimizing temperature fluctuations and to maintain at the lowest possible temperature the freezer under heat of losses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is often assumed that total head losses in a sand filter are solely due to the filtration media and that there are analytical solutions, such as the Ergun equation, to compute them. However, total head losses are also due to auxiliary elements (inlet and outlet pipes and filter nozzles), which produce undesirable head losses because they increase energy requirements without contributing to the filtration process. In this study, ANSYS Fluent version 6.3, a commercial computational fluid dynamics (CFD) software program, was used to compute head losses in different parts of a sand filter. Six different numerical filter models of varying complexities were used to understand the hydraulic behavior of the several filter elements and their importance in total head losses. The simulation results show that 84.6% of these were caused by the sand bed and 15.4% were due to auxiliary elements (4.4% in the outlet and inlet pipes, and 11.0% in the perforated plate and nozzles). Simulation results with different models show the important role of the nozzles in the hydraulic behavior of the sand filter. The relationship between the passing area through the nozzles and the passing area through the perforated plate is an important design parameter for the reduction of total head losses. A reduced relationship caused by nozzle clogging would disproportionately increase the total head losses in the sand filter

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mycoplasmas are important avian pathogens, which cause respiratory and joint diseases that result in large economic losses in Brazilian and world-wide poultry industry. This investigation regarding the main species of mycoplasmas, Mycoplasma gallisepticum (MG) and M. synoviae (MS), responsible for the above mentioned conditions, was carried out through PCR Multiplex analysis. One thousand and forty-six (1,046) samples of tracheal swabs and piped embryos were collected from 33 farms with laying hens, breeders, broilers or hatchery, located in the Brazilian states of São Paulo, Paraná and Pernambuco, where respiratory problems or drops in egg production had occurred. The MG and MS prevalence on the farms was 72.7%. These results indicated (1) high dissemination of mycoplasmas in the evaluated farms, with predominance of MS, either as single infectious agent or associated with other mycoplasmas in 20 farms (60.6%), and (2) an increase of MS and decrease of MG infection in Brazilian commercial poultry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The state of Pernambuco is the largest producer of eggs in the North and Northeast of Brazil and second one in the broiler production. Mycoplasmas are important avian pathogens, which cause respiratory and joint diseases that result in large economic losses. The aim of the present study was to investigate the occurrence of Mycoplasma gallisepticum (MG) and Mycoplasma synoviae (MS) in broilers and commercial laying hens in the state of Pernambuco, Brazil. Tracheal fragments were analyzed from 55 healthy broilers, 35 broilers with respiratory signs and 30 commercial laying hens with respiratory signs, from 24 commercial poultry farms, each sample was composed of a pool of five birds. The bacteriological exam, PCR and nested PCR were used for the detection of Mycoplasma gallisepticum (MG) and Mycoplasma synoviae (MS). All samples were negative in bacteriological isolation. In the PCR analyses, seven samples from birds with respiratory signs were positive for MS and one was positive for MG, the latter of which was confirmed as the MG-F vaccine strain. The occurrence of MS in chickens with respiratory signs may indicate inadequate sanitary management on poultry farms, favoring the propagation of mycoplasmosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The estimation of losses plays a key role in the process of building any electrical machine. How to estimate those losses while designing any machine; by obtaining the characteristic of the electrical steel from the catalogue and calculate the losses. However, this way is inaccurate since the electrical steel performs several manufacturing processes during the process of building any machine, which affects directly the magnetic property of the electrical steel and accordingly the characteristic of the electrical steel will be affected. That means the B–H curve of the steel that was obtained from the catalogue will be changed. Moreover, during loading and rotating the machine, some important changes occur to the B–H characteristic of the electrical steel such as the stress on the laminated iron. Accordingly, the pre-estimated losses are completely far from the actual losses because they were estimated based on the data of the electrical steel obtained from the catalogue. So in order to estimate the losses precisely significant factors of the manufacturing processes must be included. The paper introduces the systematic estimation of the losses including the effect of one of the manufacturing factors. Similarly, any other manufacturing factor can be included in the pre-designed losses estimations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Permanent magnet materials are nowadays widely used in the electrical machine manufacturing industry. Eddy current loss models of permanent magnets used in electrical machines are frequently discussed in research papers. In magnetic steel materials we have, in addition to eddy current losses, hysteresis losses when AC or a rotating flux travels through the material. Should a similar phenomenon also be taken into account in calculating the losses of permanent magnets? Actually, every now and then authors seem to assume that some significant hysteresis losses are present in rotating machine PMs. This paper studies the mechanisms of possible hysteresis losses in PMs and their role in PMs when used in rotating electrical machines.