999 resultados para Commercial Catalogs


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper mainly aimed to evaluate the physical and mechanical properties of LVL panels made from Eucalyptus grandis, from reforestation at the region of Senges, in Parana state, Brazil. LVL panels were manufactured using 23 veneers (2,4mm thick each one) in commercial dimension of 2.500 mm long and 1,200 mm wide. The properties of static bending were analyzed (strength and rigidity) in beams of the LVL, in the flatwise and edgewise positions. The properties of compression parallel to grain and shear parallel in the plans L-X and L-Y and density in this LVL panels were also analyzed according to ASTM-D 5456/4761 and ASTM-D 198 codes. The mean values to flatwise bending MOE and MOR were 13114 MPa and 88.76 MPa, respectively, and for edgewise bending MOE and MOR were 15871 MPa and 88.63 MPa, respectively. The density (12%) of the LVL panels and of the veneers were 690 kg/m(3) and 649 kg/m(3). The mean values to parallel compression MOE and MOR were 16856 MPa and 58.05 MPa, respectively. The mean values of the maximum resistance to shear parallel in the plans L-X and L-Y were 5.96 MPa and 591 MPa, respectively. All these values reached partially or they passed the medium limits of reference (normative codes, researches and commercial catalogs) established for LVL panels and original solid wood, attesting overall the quality of those panels produced with this wood.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Being the hydrotherapy a treatment in water of great importance for children and adults with motor disability, providing safety and comfort is a very important task that is difficult to health professional without the aid of some specialized equipment. Generally imported devices are used for such purposes, these highly complex apparatus have a high cost and limit the patient's movement in water and exercise possibilities in some cases. In this work a solution will be presented to replace such equipment, using catalogs and computer modeling a prototype will be studied and new equipment will be developed to assist entry into the pool and it would also allow mobility to the patient in an aqueous medium. This safely mobility in the water increase the possibilities of exercises and the accessories founded in commercial catalogs make this project feasible from an economic aspect

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Being the hydrotherapy a treatment in water of great importance for children and adults with motor disability, providing safety and comfort is a very important task that is difficult to health professional without the aid of some specialized equipment. Generally imported devices are used for such purposes, these highly complex apparatus have a high cost and limit the patient's movement in water and exercise possibilities in some cases. In this work a solution will be presented to replace such equipment, using catalogs and computer modeling a prototype will be studied and new equipment will be developed to assist entry into the pool and it would also allow mobility to the patient in an aqueous medium. This safely mobility in the water increase the possibilities of exercises and the accessories founded in commercial catalogs make this project feasible from an economic aspect

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Second Edition. Pp.5-61 General Surgical Necessities, Gauze, Antiseptic Sundries, Surgical Sundries, Rubber Bandages, Catheters, Bougies, Splints, Tents, Emergency Bags, Surgeon's Needles, Operating Instruments, Amputating, Forceps, Aspiration, Cases, Catheters and Directors, Pocket Case Instruments, Dissecting and Post-Mortem Pp.62-118 General Operating - Osteotomy, Mastoid, Trephining, Eye Instruments, Aural, Nasal, Mouth and Throat, Tooth Forceps, Laryngoscopic Sets, Hydraulic Air Compressor, Variocele, Genito Urinary Pp. 119-167 Genito Urinary-Lithotrity, Alimentary, Anal and Rectal, Gynaecological, Pessaries, Microscopes, Syringes Pp.168-205 Chemical Apparatus and Glassware, Physician's Cabinets, Office Furniture, Operating Chairs and Tables, Hospital Beds, Cautery, Electrolytic, Batteries Pp.206-246 Cases, Varicose, Braces, Abdominal Supporters, Trusses, Invalid Chairs and Supplies, Sterilizers, Saddle-Bags, Deformity Apparatus Advertisements: Bandages, Abdominal Supporters, Rubber Supplies, Bags, Batteries, Cotton, Microscopes, Hypodermic Tablets, Atomizers, Furniture, Sterilizers, Syringes

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Section "A": Dissecting and Post-Mortem Instruments Diagnostic Instruments and Apparatus Microscopes and Microscopic Accessories Laboratory Apparatus and Glass Ware Apparatus for Blood and Urine Analysis Apparatus for Phlebotomy, Cupping and Leeching Apparatus for Infusion and Transfusion Syringes for Aspiration and Injection Osteological Preparations Section "B": Anaesthetic, General Operating, Osteotomy, Trepanning, Bullet, Pocket Case, Cautery, Ligatures, Sutures, Dressings, Etc. Section "B" continued Section "C": Eye, Ear, Nasal, Dermal, Oral, Tonsil, Tracheal, Laryngeal,Esophageal, Stomach, Intestinal, Gall Bladder Section "C": continued Section "D": Rectal, Phimosis, Prostatic, Vesical, Urethral, Ureteral, Instruments Section "E": Gynecic, Hysterectomy, Obstetrical, Instrument Satchels, Medicine Cases Section "F": Electric Cautery Transformers, Electro-Cautery Burners and Accessories, Electric Current Controllers, Electro-Diagnostic Outfits, Electrolysis Instruments Electro-Therapeutic Lamps, Faradic Batteries, Galvanic Batteries Section "G": Office Furniture, Office Sterilizing Apparatus, Hospital Supplies, Surgical Rubber Goods, Sick Room Utensils, Invalid Rolling Chairs, Invalid Supplies Section "H": Artificial Limbs, Deformity Apparatus, Fracture Apparatus, Splints, Splint Material, Elastic Hosiery, Abdominal Supporters, Crutches, Trusses, Suspensories, Etc. Index

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Copy in Dept. of Rare Books and Special Collections bound in original black leather stamped in gold. P. 9-10 lacking.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Includes general index and index to advertisers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A servo-controlled automatic machine can perform tasks that involve synchronized actuation of a significant number of servo-axes, namely one degree-of-freedom (DoF) electromechanical actuators. Each servo-axis comprises a servo-motor, a mechanical transmission and an end-effector, and is responsible for generating the desired motion profile and providing the power required to achieve the overall task. The design of a such a machine must involve a detailed study from a mechatronic viewpoint, due to its electric and mechanical nature. The first objective of this thesis is the development of an overarching electromechanical model for a servo-axis. Every loss source is taken into account, be it mechanical or electrical. The mechanical transmission is modeled by means of a sequence of lumped-parameter blocks. The electric model of the motor and the inverter takes into account winding losses, iron losses and controller switching losses. No experimental characterizations are needed to implement the electric model, since the parameters are inferred from the data available in commercial catalogs. With the global model at disposal, a second objective of this work is to perform the optimization analysis, in particular, the selection of the motor-reducer unit. The optimal transmission ratios that minimize several objective functions are found. An optimization process is carried out and repeated for each candidate motor. Then, we present a novel method where the discrete set of available motor is extended to a continuous domain, by fitting manufacturer data. The problem becomes a two-dimensional nonlinear optimization subject to nonlinear constraints, and the solution gives the optimal choice for the motor-reducer system. The presented electromechanical model, along with the implementation of optimization algorithms, forms a complete and powerful simulation tool for servo-controlled automatic machines. The tool allows for determining a wide range of electric and mechanical parameters and the behavior of the system in different operating conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Balsamic vinegar (BV) is a typical and valuable Italian product, worldwide appreciated thanks to its characteristic flavors and potential health benefits. Several studies have been conducted to assess physicochemical and microbial compositions of BV, as well as its beneficial properties. Due to highly-disseminated claims of antioxidant, antihypertensive and antiglycemic properties, BV is a known target for frauds and adulterations. For that matter, product authentication, certifying its origin (region or country) and thus the processing conditions, is becoming a growing concern. Striving for fraud reduction as well as quality and safety assurance, reliable analytical strategies to rapidly evaluate BV quality are very interesting, also from an economical point of view. This work employs silica plate laser desorption/ionization mass spectrometry (SP-LDI-MS) for fast chemical profiling of commercial BV samples with protected geographical indication (PGI) and identification of its adulterated samples with low-priced vinegars, namely apple, alcohol and red/white wines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

• We developed the first microsatellites for Passiflora setacea and characterized new sets of markers for P. edulis and P. cincinnata, enabling further genetic diversity studies to support the conservation and breeding of passion fruit species. • We developed 69 microsatellite markers and, in conjunction with assessments of cross-amplification using primers available from the literature, present 43 new polymorphic microsatellite loci for three species of Passiflora. The mean number of alleles per locus was 3.1, and the mean values of the expected and observed levels of heterozygosity were 0.406 and 0.322, respectively. • These microsatellite markers will be valuable tools for investigating the genetic diversity and population structure of wild and commercial species of passion fruit (Passiflora spp.) and may be useful for developing conservation and improvement strategies by contributing to the understanding of the mating system and hybridization within the genus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Passiflora species are distributed throughout Latin America, and Brazil and Colombia serve as the centers of diversity for this genus. We performed cross-species amplification to evaluate 109 microsatellite loci in 14 Passiflora species and estimated the diversity and genetic structure of Passiflora cincinnata, Passiflora setaceae and Passiflora edulis. A total of 127 accessions, including 85 accessions of P. edulis, a commercial species, and 42 accessions of 13 wild species, were examined. The cross-species amplification was effective for obtaining microsatellite loci (average cross-amplification of 70%). The average number of alleles per locus (five) was relatively low, and the average diversity ranged from 0.52 in P. cincinnata to 0.32 in P. setacea. The Bayesian analyses indicated that the P. cincinnata and P. setacea accessions were distributed into two groups, and the P. edulis accessions were distributed into five groups. Private alleles were identified, and suggestions for core collections are presented. Further collections are necessary, and the information generated may be useful for breeding and conservation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel capillary electrophoresis method using capacitively coupled contactless conductivity detection is proposed for the determination of the biocide tetrakis(hydroxymethyl)phosphonium sulfate. The feasibility of the electrophoretic separation of this biocide was attributed to the formation of an anionic complex between the biocide and borate ions in the background electrolyte. Evidence of this complex formation was provided by (11) B NMR spectroscopy. A linear relationship (R(2) = 0.9990) between the peak area of the complex and the biocide concentration (50-900 μmol/L) was found. The limit of detection and limit of quantification were 15.0 and 50.1 μmol/L, respectively. The proposed method was applied to the determination of tetrakis(hydroxymethyl)phosphonium sulfate in commercial formulations, and the results were in good agreement with those obtained by the standard iodometric titration method. The method was also evaluated for the analysis of tap water and cooling water samples treated with the biocide. The results of the recovery tests at three concentration levels (300, 400, and 600 μmol/L) varied from 75 to 99%, with a relative standard deviation no higher than 9%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sunlight exposure causes several types of injury to humans, especially on the skin; among the most common harmful effects due to ultraviolet (UV) exposure are erythema, pigmentation and lesions in DNA, which may lead to cancer. These long-term effects are minimized with the use of sunscreens, a class of cosmetic products that contains UV filters as the main component in the formulation; such molecules can absorb, reflect or diffuse UV rays, and can be used alone or as a combination to broaden the protection on different wavelengths. Currently, worldwide regulatory agencies define which ingredients and what quantities must be used in each country, and enforce companies to conduct tests that confirm the Sun Protection Factor (SPF) and the UVA (Ultraviolet A) factor. Standard SPF determination tests are currently conducted in vivo, using human subjects. In an industrial mindset, apart from economic and ethical reasons, the introduction of an in vitro method emerges as an interesting alternative by reducing risks associated to UV exposure on tests, as well as providing assertive analytical results. The present work aims to describe a novel methodology for SPF determination directly from sunscreen formulations using the previously described cosmetomics platform and mass spectrometry as the analytical methods of choice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Owing to improvements in its mechanical properties and to the availability of shade and translucence resources, resin composite has become one of the most widely used restorative materials in present day Dentistry. The aim of this study was to assess the relation between the surface hardness of seven different commercial brands of resin composites (Charisma, Fill Magic, Master Fill, Natural Look, Opallis, Tetric Ceram, and Z250) and the different degrees of translucence (translucid, enamel and dentin). Vickers microhardness testing revealed significant differences among the groups. Z250 was the commercial brand that showed the best performance in the hardness test. When comparing the three groups assessed within the same brand, only Master Fill and Fill Magic presented statistically significant differences among all of the different translucencies. Natural Look was the only one that showed no significant difference among any of the three groups. Charisma, Opallis, Tetric Ceram and Z250 showed significant differences among some of the tested groups. Based on the results found in this study, it was not possible to establish a relation between translucence and the microhardness of the resin composites assessed. Depending on the material assessed, however, translucence variation did affect the microhardness values of the resin composites.