920 resultados para Combined sewer overflows.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Project no. 20.137."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The overarching goal of this research is to establish a successful forum for a transition from the existing paradigm of managing wastewater infrastructure to a more sustainable paradigm that achieves a more efficient utilisation of wastewater assets. A transitioning approach to support a more efficient utilisation of surface water and wastewater assets and infrastructure is proposed and developed. The determined transitioning approach possesses key stages namely developing the arena, developing the agenda, case study, and monitoring. The case study stage investigates a drainage utility identifying their improvement drivers, the removal of surface water through detailed drainage modelling and the financial examination of the costs incurred under the various scenarios conducted. Understanding the implications of removing/attenuating surface water from the network is improved through obtaining data by detailed drainage modelling. Infoworks software is used to investigate and assess the current and future operational scenarios of a wastewater system operating over one calendar year. Modelling scenarios were conducted removing surface water from selected areas focusing on the volumes requiring pumping and durations of pumping station(s) operation prior to treatment during storm conditions. The financial implication of removing surface water in combined sewer systems is examined in three main components. Firstly the costs of electricity incurred at the single sewage pumping station (SPS) investigated during the various scenarios modelled require to be addressed. Secondly the costs to retrofit sustainable urban drainage system (SUDS) solutions needs to be identified. Thirdly the implications of removing surface water for the drainage utility at the national level and the potential saving for householder’s committing to a surface water disconnection rebate scheme. When addressed at the macro level i.e., with over 2,100 pumping stations, some operating in sequence and contained within one drainage utility annually treating 315,360 megalitres the significance of the same multiple quantifiable and intangible benefits becomes amplified. The research aims, objectives and findings are presented to the identified and convened stakeholders. The transitioning approach developed encourages positive discourse between stakeholders. The level of success of the transitioning approach determined is then tested using a quantitative methodology through the completion of questionnaires. From the questionnaires completed the respondents unanimously agreed that surface water flows should be removed as well as reduced from the combined sewer system. The respondents agreed that the removal of surface water from a typical combined sewer system is justified by applying a transitioning approach focusing on the energy consumption required to pump increased volumes during storm events. This response is significant based upon the economic evidence and is contrary to the respondents previous position that finance was their most influencing factor. When provided with other potentially available benefits the respondents were even more supportive of the justification to remove surface water from the combined sewer system. The combined findings of the work presented in this thesis provide further justification that the transitioning approach applied to the removal of surface water from a typical combined sewer system, as determined in this research has been successful.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Canada releases over 150 billion litres of untreated and undertreated wastewater into the water environment every year1. To clean up urban wastewater, new Federal Wastewater Systems Effluent Regulations (WSER) on establishing national baseline effluent quality standards that are achievable through secondary wastewater treatment were enacted on July 18, 2012. With respect to the wastewater from the combined sewer overflows (CSO), the Regulations require the municipalities to report the annual quantity and frequency of effluent discharges. The City of Toronto currently has about 300 CSO locations within an area of approximately 16,550 hectares. The total sewer length of the CSO area is about 3,450 km and the number of sewer manholes is about 51,100. A system-wide monitoring of all CSO locations has never been undertaken due to the cost and practicality. Instead, the City has relied on estimation methods and modelling approaches in the past to allow funds that would otherwise be used for monitoring to be applied to the reduction of the impacts of the CSOs. To fulfill the WSER requirements, the City is now undertaking a study in which GIS-based hydrologic and hydraulic modelling is the approach. Results show the usefulness of this for 1) determining the flows contributing to the combined sewer system in the local and trunk sewers for dry weather flow, wet weather flow, and snowmelt conditions; 2) assessing hydraulic grade line and surface water depth in all the local and trunk sewers under heavy rain events; 3) analysis of local and trunk sewer capacities for future growth; and 4) reporting of the annual quantity and frequency of CSOs as per the requirements in the new Regulations. This modelling approach has also allowed funds to be applied toward reducing and ultimately eliminating the adverse impacts of CSOs rather than expending resources on unnecessary and costly monitoring.