946 resultados para Cochlear implant. speech perception, users


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper studies the effect of residual hearing on post-implant speech perception in children with cochlear implants. The effect of pre-implant auditory experience and the effect of neuronal survival in the implanted ear were investigated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Most cochlear implant (CI) users, who suffer from post lingual hearing loss, are able to perceive sounds and comprehend speech after the implant. The prediction of maximal benefit over time, with the use of CI, can be useful for counseling patients about their expectations in using the new device. The measurement of satisfaction should be of primary interest in medical intervention, as the results may be used for intervention feedback. The purpose of this study is to analyze auditory performance of CI over time, as well as to evaluate users‟ satisfaction. Therefore two types of study designs were employed: a) retrospective cohort study with the analysis of medical records from 59 subjects about auditory performance before and after surgery. Results were submitted to the Kaplan -Meier estimator of cumulative probability and compared to prognostic factors of auditory performance using the logrank test. b) A sectional study design was conducted to evaluate the satisfaction of 51 subjects. The instrument consists of two specific questionnaires: Satisfaction with Amplification in Daily Life SADL and International Outcome Inventory Cochlear Implant IOI- CI. Results show statistical significant differences (p<0,001) in auditory performance before and after CI. The majority obtained satisfactory results of CI use during the first six months. Logrank tests does not indicate significant correlation between the analyzed covariates and the time in which adequate speech perception occurs. SADL e IOI-CI questionnaires indicate that most of the CI users are satisfied with their devices. The SADL detected a 27, 5% insatisfaction amongst CI users in relation to services and costs involved with the CI. The results of the IOI show 4% of insatisfaction with the use of CI and the social environment. In conclusion CI is capable to rehabilitate social auditory function in a short period of time and CI users demonstrate satisfaction with auditory, social and psychological gain offered through CI device

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Users of cochlear implant systems, that is, of auditory aids which stimulate the auditory nerve at the cochlea electrically, often complain about poor speech understanding in noisy environments. Despite the proven advantages of multimicrophone directional noise reduction systems for conventional hearing aids, only one major manufacturer has so far implemented such a system in a product, presumably because of the added power consumption and size. We present a physically small (intermicrophone distance 7 mm) and computationally inexpensive adaptive noise reduction system suitable for behind-the-ear cochlear implant speech processors. Supporting algorithms, which allow the adjustment of the opening angle and the maximum noise suppression, are proposed and evaluated. A portable real-time device for test in real acoustic environments is presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Users of cochlear implants (auditory aids, which stimulate the auditory nerve electrically at the inner ear) often suffer from poor speech understanding in noise. We evaluate a small (intermicrophone distance 7 mm) and computationally inexpensive adaptive noise reduction system suitable for behind-the-ear cochlear implant speech processors. The system is evaluated in simulated and real, anechoic and reverberant environments. Results from simulations show improvements of 3.4 to 9.3 dB in signal to noise ratio for rooms with realistic reverberation and more than 18 dB under anechoic conditions. Speech understanding in noise is measured in 6 adult cochlear implant users in a reverberant room, showing average improvements of 7.9–9.6 dB, when compared to a single omnidirectional microphone or 1.3–5.6 dB, when compared to a simple directional two-microphone device. Subjective evaluation in a cafeteria at lunchtime shows a preference of the cochlear implant users for the evaluated device in terms of speech understanding and sound quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates the conversational fluency of young cochlear implant users. The study compares objective measures and subjective impressions of conversation fluency, relates how children’s communication skills influence both objective and subjective measures of conversational fluency, and compares the performance of children who use an oral mode with those who use a total communication mode in everyday conversation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study examines specific auditory features perceived by profoundly hearing-impaired children using conventional binaural hearing aids and the Nucleus 22 Channel Cochlear Implant. The primary interest of this study was to learn which speech features were most easily perceived by users of each device.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Most clinically-employed speech materials for testing hearing impaired individuals are recordings made by adult male talkers. The author examined the possible effect of talker age and gender on the speech perception of children through the use of 1) two speech perception tests, each with four talker types (adult males, adult females, 10-12 year olds, 5-7 year olds), and 2) two groups of pediatric listeners: normal-hearing (NH) and cochlear implant users (CI).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To characterize the PI component of long latency auditory evoked potentials (LLAEPs) in cochlear implant users with auditory neuropathy spectrum disorder (ANSD) and determine firstly whether they correlate with speech perception performance and secondly whether they correlate with other variables related to cochlear implant use. Methods: This study was conducted at the Center for Audiological Research at the University of Sao Paulo. The sample included 14 pediatric (4-11 years of age) cochlear implant users with ANSD, of both sexes, with profound prelingual hearing loss. Patients with hypoplasia or agenesis of the auditory nerve were excluded from the study. LLAEPs produced in response to speech stimuli were recorded using a Smart EP USB Jr. system. The subjects' speech perception was evaluated using tests 5 and 6 of the Glendonald Auditory Screening Procedure (GASP). Results: The P-1 component was detected in 12/14 (85.7%) children with ANSD. Latency of the P-1 component correlated with duration of sensorial hearing deprivation (*p = 0.007, r = 0.7278), but not with duration of cochlear implant use. An analysis of groups assigned according to GASP performance (k-means clustering) revealed that aspects of prior central auditory system development reflected in the P-1 component are related to behavioral auditory skills. Conclusions: In children with ANSD using cochlear implants, the P-1 component can serve as a marker of central auditory cortical development and a predictor of the implanted child's speech perception performance. (c) 2012 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To analyze speech reading through Internet video calls by profoundly hearing-impaired individuals and cochlear implant (CI) users. METHODS Speech reading skills of 14 deaf adults and 21 CI users were assessed using the Hochmair Schulz Moser (HSM) sentence test. We presented video simulations using different video resolutions (1280 × 720, 640 × 480, 320 × 240, 160 × 120 px), frame rates (30, 20, 10, 7, 5 frames per second (fps)), speech velocities (three different speakers), webcameras (Logitech Pro9000, C600 and C500) and image/sound delays (0-500 ms). All video simulations were presented with and without sound and in two screen sizes. Additionally, scores for live Skype™ video connection and live face-to-face communication were assessed. RESULTS Higher frame rate (>7 fps), higher camera resolution (>640 × 480 px) and shorter picture/sound delay (<100 ms) were associated with increased speech perception scores. Scores were strongly dependent on the speaker but were not influenced by physical properties of the camera optics or the full screen mode. There is a significant median gain of +8.5%pts (p = 0.009) in speech perception for all 21 CI-users if visual cues are additionally shown. CI users with poor open set speech perception scores (n = 11) showed the greatest benefit under combined audio-visual presentation (median speech perception +11.8%pts, p = 0.032). CONCLUSION Webcameras have the potential to improve telecommunication of hearing-impaired individuals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Speech coding might have an impact on music perception of cochlear implant users. This questionnaire study compares the musical activities and perception of postlingually deafened cochlear implant users with three different coding strategies (CIS, ACE, SPEAK) using the Munich Music Questionnaire. Overall, the self-reported perception of music of CIS, SPEAK, and ACE users did not differ by very much.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Music plays an important role in the daily life of cochlear implant (CI) users, but electrical hearing and speech processing pose challenges for enjoying music. Studies of unilateral CI (UCI) users' music perception have found that these subjects have little difficulty recognizing tempo and rhythm but great difficulty with pitch, interval and melody. The present study is an initial step towards understanding music perception in bilateral CI (BCI) users. The Munich Music Questionnaire was used to investigate music listening habits and enjoyment in 23 BCI users compared to 2 control groups: 23 UCI users and 23 normal-hearing (NH) listeners. Bilateral users appeared to have a number of advantages over unilateral users, though their enjoyment of music did not reach the level of NH listeners.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The primary objective of this study was to document the benefits and possible detriments of combining ipsilateral acoustic hearing in the cochlear implant ear of a patient with preserved low frequency residual hearing post cochlear implantation. The secondary aim was to examine the efficacy of various cochlear implant mapping and hearing aid fitting strategies in relation to electro-acoustic benefits.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The primary purpose of this study was to evaluate speech perception and localization abilities in children who have received sequential cochlear implants, with the first implant received before age 4 and the second implant received before age 12. Results indicate performance in the bilateral cochlear implant condition is significantly better than listening with each implant alone for the outcome measures used in this study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate the effects of bimodal (implant plus hearing aid) listening on speech recognition in four different environment conditions. Results indicate that there was little difference in the cochlear implant only and bimodal conditions.