1000 resultados para Coagglutination Test
Resumo:
Protein A containing Staphylococcus aureus was used to develop a coagglutination (COA) test for the detection and typing of foot and mouth disease virus (FMDV) O, A and C serotypes in infected cells and tissues. Different batches and amounts of guinea pig anti-FMDV sera were assessed to optimize the preparation of COA conjugates. The sensitivity and specificity of the COA Test for the detection of FMDV O, A and C serotypes and heterologous viruses was also characterized. Comparison between the COA Test and complement fixation test for the detection and typing of FMDV obtained from extracts of tongue epithelial tissues from infected cattle revealed high agreement in the results and indicated a potential application of the COA Test for the direct diagnosis of viruses.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Foram utilizadas 82 LCR de transplantados renais (24 pacientes), 43 LCR de pacientes com críptococose comprovada (controles positivos), 35 LCR de pacientes com outras doenças (histoplasmose, paracoccidioidomicose e infecções bacterianas) como controles negativos. Os primeiros foram cultivados em ágar Sabouraud com sementes de girassol e juntamente com os demais examinado pelo teste de látex para pesquisa de antígeno circulante de C. neoformans, qualitativamente. O teste de Coaglutinação foi realizado qualitativamente e quantitativamente, encontrando-se títulos até a diluição 1:2048. Não foram detectadas reações falso-positivas ou falso-negativas entre os controles. Como prova de valor diagnóstico demonstrou: sensibilidade - 92,1%; especificidade - 92,6% e eficiência - 92,3%. Provou também ser um teste rápido, exato e econômico, embora sua escolha dependa do pré-tratamento de LCR (80ºC por 3 a 5 minutos) e soros (diluição ou álcali-precipitação) para evitar autoaglutinação e aumentar a sensibilidade da reação.
Resumo:
A simple and rapid staphylococcal coagglutination test for the detection of Toxoplasma gondii antigens in mice urine is described. A suspension of protein-A containing Staphylococcus aureus coated with rabbit hyperimmune serum was used as reagent. The sensitivity of the antigen assay was found to be at least 118 ng of the antigen protein per ml. No coagglutination was observed when the reagent was challenged against antigenic solutions of other parasites. The suitability of the method for detecting antigens of T. gondii in urine samples was studied by experimental toxoplasma infection in mice. Before the staphylococcal test, the urine samples were double serially diluted in 0.1 M PBS. From the second day on all samples from infected mice were positive at 1/16 dilution. At this dilution, all samples from non infected mice were negative or did not produce coagglutination. This method might be used in the rapid etiological diagnosis also in human cases of acute toxoplasmosis.
Resumo:
A longitudinal study was performed with sera and urine of patients with acquired immune deficiency syndrome (AIDS), taken before, during and after clinically Toxoplasma infection. The tested patients were followed for an average of two years. The titres of the specific IgG and IgM antibodies were measured by an indirect fluorescent antibody test (IFAT), and the appearance of circulating antigens of T. gondii was determined in 36 urine samples of 13 patients with neurotoxoplasmosis by means of the coagglutination test. The presence of T. gondii antigens in the urine of AIDS patients by this test was correlated with the immunoblot technique, with clinical symptoms and also with pathological findings. Our results indicate that the detection of T. gondii antigens in the urine of AIDS patients can be regarded as a rapid and efficient method for the diagnosis of acute toxoplasmosis
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of the study was to develop a culturally adapted translation of the 12-item smell identification test from Sniffin' Sticks (SS-12) for the Estonian population in order to help diagnose Parkinson's disease (PD). A standard translation of the SS-12 was created and 150 healthy Estonians were questioned about the smells used as response options in the test. Unfamiliar smells were replaced by culturally familiar options. The adapted SS-12 was applied to 70 controls in all age groups, and thereafter to 50 PD patients and 50 age- and sex-matched controls. 14 response options from 48 used in the SS-12 were replaced with familiar smells in an adapted version, in which the mean rate of correct response was 87% (range 73-99) compared to 83% with the literal translation (range 50-98). In PD patients, the average adapted SS-12 score (5.4/12) was significantly lower than in controls (average score 8.9/12), p < 0.0001. A multiple linear regression using the score in the SS-12 as the outcome measure showed that diagnosis and age independently influenced the result of the SS-12. A logistic regression using the SS-12 and age as covariates showed that the SS-12 (but not age) correctly classified 79.0% of subjects into the PD and control category, using a cut-off of <7 gave a sensitivity of 76% and specificity of 86% for the diagnosis of PD. The developed SS-12 cultural adaption is appropriate for testing olfaction in Estonia for the purpose of PD diagnosis.
Resumo:
to investigate the pulmonary response to exercise of non-morbidly obese adolescents, considering the gender. a prospective cross-sectional study was conducted with 92 adolescents (47 obese and 45 eutrophic), divided in four groups according to obesity and gender. Anthropometric parameters, pulmonary function (spirometry and oxygen saturation [SatO2]), heart rate (HR), blood pressure (BP), respiratory rate (RR), and respiratory muscle strength were measured. Pulmonary function parameters were measured before, during, and after the exercise test. BP and HR were higher in obese individuals during the exercise test (p = 0.0001). SatO2 values decreased during exercise in obese adolescents (p = 0.0001). Obese males had higher levels of maximum inspiratory and expiratory pressures (p = 0.0002) when compared to obese and eutrophic females. Obese males showed lower values of maximum voluntary ventilation, forced vital capacity, and forced expiratory volume in the first second when compared to eutrophic males, before and after exercise (p = 0.0005). Obese females had greater inspiratory capacity compared to eutrophic females (p = 0.0001). Expiratory reserve volume was lower in obese subjects when compared to controls (p ≤ 0,05). obese adolescents presented changes in pulmonary function at rest and these changes remained present during exercise. The spirometric and cardiorespiratory values were different in the four study groups. The present data demonstrated that, in spite of differences in lung growth, the model of fat distribution alters pulmonary function differently in obese female and male adolescents.
Resumo:
To assess binocular detection grating acuity using the LEA GRATINGS test to establish age-related norms in healthy infants during their first 3 months of life. In this prospective, longitudinal study of healthy infants with clear red reflex at birth, responses to gratings were measured at 1, 2, and 3 months of age using LEA gratings at a distance of 28 cm. The results were recorded as detection grating acuity values, which were arranged in frequency tables and converted to a one-octave scale for statistical analysis. For the repeated measurements, analysis of variance (ANOVA) was used to compare the detection grating acuity results between ages. A total of 133 infants were included. The binocular responses to gratings showed development toward higher mean values and spatial frequencies, ranging from 0.55 ± 0.70 cycles per degree (cpd), or 1.74 ± 0.21 logMAR, in month 1 to 3.11 ± 0.54 cpd, or 0.98 ± 0.16 logMAR, in month 3. Repeated ANOVA indicated differences among grating acuity values in the three age groups. The LEA GRATINGS test allowed assessment of detection grating acuity and its development in a cohort of healthy infants during their first 3 months of life.
Resumo:
This study sought to analyse the behaviour of the average spinal posture using a novel investigative procedure in a maximal incremental effort test performed on a treadmill. Spine motion was collected via stereo-photogrammetric analysis in thirteen amateur athletes. At each time percentage of the gait cycle, the reconstructed spine points were projected onto the sagittal and frontal planes of the trunk. On each plane, a polynomial was fitted to the data, and the two-dimensional geometric curvature along the longitudinal axis of the trunk was calculated to quantify the geometric shape of the spine. The average posture presented at the gait cycle defined the spine Neutral Curve. This method enabled the lateral deviations, lordosis, and kyphosis of the spine to be quantified noninvasively and in detail. The similarity between each two volunteers was a maximum of 19% on the sagittal plane and 13% on the frontal (p<0.01). The data collected in this study can be considered preliminary evidence that there are subject-specific characteristics in spinal curvatures during running. Changes induced by increases in speed were not sufficient for the Neutral Curve to lose its individual characteristics, instead behaving like a postural signature. The data showed the descriptive capability of a new method to analyse spinal postures during locomotion; however, additional studies, and with larger sample sizes, are necessary for extracting more general information from this novel methodology.
Resumo:
Objective To assess the neurodevelopmental functions (cognition, language and motor function) of survivors of twin-twin transfusion syndrome (TTTS). Method Observational cross-sectional study of a total of 67 monochorionic diamniotic twins who underwent fetoscopic laser coagulation (FLC) for treatment of TTTS. The study was conducted at the Center for Investigation in Pediatrics (CIPED), Universidade Estadual de Campinas. Ages ranged from one month and four days to two years four months. Bayley Scales of Infant and Toddler Development Screening Test-III, were used for evaluation. Results Most children reached the competent category and were classified as having appropriate performance. The preterm children scored worse than term infants for gross motor subtest (p = 0.036). Conclusion The majority of children reached the expected development according to their age. Despite the good neurodevelopment, children classified at risk should be monitored for development throughout childhood.
Resumo:
This work investigated the cytotoxic and genotoxic potential of water from the River Paraíba do Sul (Brazil) using Allium cepa roots. An anatomo-morphological parameter (root length), mitotic indices, and frequency of micronuclei were analysed. Eight bulbs were chosen at random for treatment for 24 to 120 hours with the River water collected in the years of 2005 and 2006 from sites in the cities of Tremembé and Aparecida (São Paulo state, Brazil). Daily measurements of the length of the roots grown from each bulb were carried out throughout the experiment. Mitotic index (MI) and frequency of micronuclei (MN) were determined for 2000 cells per root, using 3-5 root tips from other bulbs (7-10). Only in the roots treated with samples of the River water collected in 2005 in Tremembé city was there a decrease in the root length growth compared to the respective control. However, a reduction in MI values was verified for both sites analysed for that year. Considering the data involving root length growth and especially MI values, a cytotoxic potential is suggested for the water of the River Paraíba do Sul at Tremembé and Aparecida, in the year of 2005. On the other hand, since in this year the MN frequency was not affected with the river water treatments, genotoxicity is not assumed for the river water sampled at the aforementioned places.
Resumo:
PURPOSE: To compare intraocular pressure (IOP) rise in normal individuals and primary open-angle glaucoma patients and the safety and efficacy of ibopamine eye drops in different concentrations as a provocative test for glaucoma. METHODS: Glaucoma patients underwent (same eye) the ibopamine provocative test with two concentrations, 1% and 2%, in a random sequence at least 3 weeks apart, but not more than 3 months. The normal individuals were randomly submitted to one of the concentrations of ibopamine (1% and 2%). The test was considered positive if there was an IOP rise greater than 3 or 4 mmHg at 30 or 45 minutes to test which subset of the test has the best sensitivity (Se)/specificity (Sp). RESULTS: There was no statistically significant difference in any of the IOP measurements, comparing 1% with 2% ibopamine. The IOP was significantly higher at 30 and 45 minutes with both concentrations (p<0.001). The best sensitivity/specificity ratio was achieved with the cutoff point set as greater than 3 mmHg at 45 minutes with 2% ibopamine (area under the ROC curve: 0.864, Se: 84.6%; Sp:73.3%). All patients described a slight burning after ibopamine's instillation. CONCLUSION: 2% ibopamine is recommended as a provocative test for glaucoma. Because both concentrations have similar ability to rise IOP, 1% ibopamine may be used to treat ocular hypotony.
Resumo:
Standardized olfactory tests are now available to quantitatively assess disorders of olfaction. A Brazilian-Portuguese version of the University of Pennsylvania Smell Identification Test (UPSIT) is currently being developed specifically for the Brazilian population. The most recent Brazilian-Portuguese version of the UPSIT (UPSIT-Br2) was administered to 88 Brazilian subjects who had no history of neurological or otorhinolaryngological disease. UPSIT-Br2 scores decreased with age, were lower in men than in women, and were lower in subjects with lower income. The degree to which the poorer performance of subjects with lower socio-economic status reflects lack of familiarity with test items is not known. Although this version of the UPSIT provides a sensitive and useful test of smell function for the Brazilian population, a revision of some test items is needed to achieve comparable norms to those found using the North American UPSIT in the United States.