999 resultados para Co Poisoning


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Guidance for primarycareon how to deal withpatients presenting with possible symptoms of carbon monoxide (CO) poisoning. Produced by the Health Protection Agency and adapted by the Public Health Agency.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Guidance for primary�care�on how to deal with�patients presenting with possible symptoms of carbon monoxide (CO) poisoning. Produced by the Health Protection Agency and adapted by the Public Health Agency.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Even if there is clinical evidence that carbon monoxide poisoning determines cardiac damage, the literature on the cardiac pathomorphology in such cases is scarce. We investigated the immunohistochemical expression of two known markers of fresh cardiac damage, fibronectin and the terminal complement complex C5b-9, in both cardiac ventricles in 26 cases of CO intoxication (study group, 15 ♀, 11 ♂, mean age 47 years, mean COHb level 65.9%, min. 51%, max. 85%) compared to a group of 23 cases of hanging (n = 23, 4♀, 19♂, mean age 42 years) as well as to 25 cases of myocardial infarction (n = 25, 13♀, 12♂, mean age 64 years). Fresh cardiac damage was detected with the antibody fibronectin in cases of CO poisoning and was prevalently localised at the right ventricle.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Introduction: Carbon monoxide (CO) poisoning is one of the mostcommon causes of fatal poisoning. Symptoms of CO poisoning arenonspecific and the documentation of elevated carboxyhemoglobin(HbCO) levels in arterial blood sample is the only standard ofconfirming suspected exposure. The treatment of CO poisoning requiresnormobaric or hyperbaric oxygen therapy, according to the symptomsand HbCO levels. A new device, the Rad-57 pulse CO-oximeter allowsnoninvasive transcutaneous measurement of blood carboxyhemoglobinlevel (SpCO) by measurement of light wavelength absorptions.Methods: Prospective cohort study with a sample of patients, admittedbetween October 2008 - March 2009 and October 2009 - March 2010,in the emergency services (ES) of a Swiss regional hospital and aSwiss university hospital (Burn Center). In case of suspected COpoisoning, three successive noninvasive measurements wereperformed, simultaneously with one arterial blood HbCO test. A controlgroup includes patients admitted in the ES for other complaints (cardiacinsufficiency, respiratory distress, acute renal failure), but necessitatingarterial blood testing. Informed consent was obtained from all patients.The primary endpoint was to assess the agreement of themeasurements made by the Rad-57 (SpCO) and the blood levels(HbCO).Results: 50 patients were enrolled, among whom 32 were admittedfor suspected CO poisoning. Baseline demographic and clinicalcharacteristics of patients are presented in table 1. The median age was37.7 ans ± 11.8, 56% being male. Median laboratory carboxyhemoglobinlevels (HbCO) were 4.25% (95% IC 0.6-28.5) for intoxicated patientsand 1.8% (95% IC 1.0-5.3) for control patients. Only five patientspresented with HbCO levels >= 15%. The results disclose relatively faircorrelations between the SpCO levels obtained by the Rad-57 and thestandard HbCO, without any false negative results. However, theRad-57 tend to under-estimate the value of SpCO for patientsintoxicated HbCO levels >10% (fig. 1).Conclusion: Noninvasive transcutaneous measurement of bloodcarboxyhemoglobin level is easy to use. The correlation seems to becorrect for low to moderate levels (<15%). For higher values, weobserve a trend of the Rad-57 to under-estimate the HbCO levels. Apartfrom this potential limitation and a few cases of false-negative resultsdescribed in the literature, the Rad-57 may be useful for initial triageand diagnosis of CO.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of the study is to present the application of a headspace-gas chromatography-mass spectrometry (HS-GC-MS) method for the determination of the carbon monoxide (CO) blood concentration and to compare it with carboxyhemoglobin (HbCO) saturation. In postmortem cases, the HbCO measured by spectrophotometry frequently leads to inaccurate results due to inadequate samples or analyses. The true role of CO intoxication in the death of a person could be misclassified. The estimation of HbCO from HS-GC-MS CO measurements provides helpful information by determining the total CO levels (CO linked to hemoglobin (HbCO) and CO dissociated from hemoglobin). The CO concentrations were converted in HbCO saturation levels to define cutoff blood CO values. CO limits were defined as less than 1 μmol/mL for living persons, less than 1.5 μmol/mL for dead persons without CO exposure, and greater than 3 μmol/mL for dead persons with clear CO poisoning.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the present paper we investigated the effect of adsorbed PVA on Pt electrodes on classic electrochemical processes such as hydrogen UPD, oxygen reduction and CO electro-oxidation. Upon adsorption PVA blocks roughly 50% of the hydrogen sites and can not be removed from the Pt surface through cycling in the potential range of 0.05-1.0 V vs. RHE. Potentiodynamic experiments under controlled hydrodynamic conditions provided by rotating disk electrode experiments showed a negative impact of the adsorbed PVA on the oxygen reduction reaction (ORR). Cyclic-voltammetry results revealed that not even CO was able to remove PVA from the Pt surface. Regarding the oxidation of CO, the adsorbed polymer positively shifted the CO oxidation peak potential, therefore higher potentials are required to free the Pt surface from CO poisoning. In situ Fourier transform infrared spectroscopy evidenced that the presence of PVA shifted the linearly bound CO frequency toward higher wavenumbers, a process found to be independent of the Pt surface orientation. In situ electrochemical X-ray absorption spectroscopy results showed that PVA also impacted the electronic properties of platinum by decreasing the occupancy of the Pt conducting 5d band. Our findings clearly support the efforts toward understanding the nature of the interaction between polymers and metallic surfaces as well as the impact on technological applications (e.g. in PEMFCs). © 2013 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aiming to reduce the cost of electrocatalysts and a greater resistance to CO poisoning this work was to study the adsorption and oxidation of carbon monoxide on ordered intermetallic phases AuIn, AuSb2, AuSn, PdSb and PdSn using voltammetric techniques in alkaline electrolyte solution. The results suggest that the AuSn and PdSn intermetallics has some form of resistance to CO poisoning. It is assumed that this behavior is a result of electronic effect and the effect of the third body has been achieved by adding a second metal to Au and Pd. However, further studies should be conducted to confirm this hypothesis as to test these materials as electrocatalysts in the reaction of oxidation of fuels

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The performance of an ABPBI-based High Temperature H-2/O-2 PEMFC system was studied under different experimental conditions. Increasing the temperature from 130 to 170 degrees C improved the cell performance, even though further increase was not beneficial for the system. Humidification of the H-2 stream ameliorated this behaviour, even though operating above 170 degrees C is not advisable in terms of cell performance. A significant electrolyte dehydration seems to negatively affect the fuel cell performance, especially in the case of the anode. In the presence of 2% vol. CO in the H-2 stream, the temperature exerted a positive effect on the cell performance, reducing the strong adsorption of this poison on the platinum sites. Moreover, humidification of the H-2 + CO stream increased the maximum power densities of the cell, further alleviating the CO poisoning effects. Actual CO-O-2 fuel cell results confirmed the significant beneficial effect of the relative humidity on the kinetics of the CO oxidation process. Copyright (C) 2011, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work, a working model is proposed of molecular sieve silica (MSS) multistage membrane systems for CO cleanup at high temperatures (up to 500 degrees C) in a simulated fuel cell fuel processing system. Gases are described as having little interactions with each other relative to the pore walls due to low isosteric heat of adsorption on silica surfaces and high temperatures. The Arrhenius function for activated transport of pure gases was used to predict mixture concentration in the permeate and retentate streams. Simulation predicted CO could be reduced to levels below the required 50 ppmv for polymer electrolyte membrane fuel cell anodes at a stage H-2/CO selectivity of higher than 40 in 4 series membrane units. Experimental validation showed predicting mixture concentrations required only pure gas permeation data. This model has significant application for setting industrial stretch targets and as a robust basis for complex membrane model configurations. (c) 2006 American Institute of Chemical Engineers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The production of hyperglycemia during the acute phase of scorpion poisoning produced by T. bahiensis in dogs is confirmed now. The highest degree on average, was reached 10 minutes after the injection of venom. In our hands, the previous bilateral adrenalectomy did not avoid the hyperglycemia. The average of the blood sugar level has been similar to that observed in dogs with adrenal glands, the highest blood sugar level was also registered after 10 minutes. The hyperglycemia obtained in adrenolectomized dogs is, probably, due to the liberation of Sympatin (Nor-adrenalin and adrenalin) as a consequence of the central excitation by the poison on the hepatic nerves and other ganglionar terminations of the Sympathetic Nervous System. Our present researches suggest that the venom has adrenergic action besides the central action.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study reports the occurrence of lead poisoning in a male, 2 year-old mongrel dog attended at UNESP Botucatu Veterinary Hospital. The animal was brought to the hospital with claim of gastrointestinal and nervous disturbs for 10 days, worsening in the last 24 hours. After unsuccessfully attempts to control status epileticus, the animal died. Hematological evaluation revealed significant rubricytosis and basophilic stippling, highly suggestive of lead poisoning. Serum lead concentration confirmed toxic levels of this element. Necropsy evidenced the presence of foreign bodies in stomach (one stone and two metallic objects) and, microscopically, characteristic inclusions in renal parenchyma. Fragments obtained from liver and kidneys revealed lead concentrations of 0, 8 μg/g and 25 μg/g, respectively, which in association to clinical signs of saturnism, determined the diagnosis of lead poisoning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The copolymer poly (L-co-D,L lactic acid), PLDLA, has gained prominence in the field of temporary prostheses due to the fact that their time of degradation is quite compatible with the requirement in the case of osseous fracture. In this work the in vivo degradation of devices from copolymer, as a system of plates and screws, used in fixation of the tibia of rabbits was studied. The devices were implanted in 15 adult rabbits, albinos, New Zealand race, and they were used as control devices of alloys of titanium (Ti-6Al-4V/ V grade). The use of copolymers, synthesized in the laboratory, was tested in the repair of fracture in rabbits'tibias, being assessed in the following times: 2 weeks, 2 months and 3 months. Morphological analysis of tissue surrounding the plate and screw system, for 2 weeks of implantation, showed the presence of osteoblasts, indicating a pre bone formation. After 2 months there was new bone formation in the region in contact with the polymer. This bone growth occurred simultaneously with the process of PLDLA degradation, invading the region where there was polymer and after 3 months there was an intense degradation of the copolymer and hence greater tissue invasion compared to 2 months which characterized bone formation in a region where the polymer degraded. The in vivo degradation study of the devices for PLDLA by means of histological evaluations during the period of consolidation of the fracture showed the efficiency of plate and screw system, and it was possible to check formation of bone tissue at the implantation site, without the presence of inflammatory reaction