892 resultados para Clinical methods


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. Clinicians commonly assess posture in persons with musculoskeletal disorders and tend to do so subjectively. Evidence-based practice requires the use of valid, reliable and sensitive tools to monitor treatment effectiveness. The purpose of this article was to determine which methods were used to assess posture quantitatively in a clinical setting and to identify psychometric properties of posture indices measured from these methods or tools. Methods. We conducted a comprehensive literature review. Pertinent databases were used to search for articles on quantitative clinical assessment of posture. Searching keywords were related to posture and assessment, scoliosis, back pain, reliability, validity and different body segments. Results. We identified 65 articles with angle and distance posture indices that corresponded to our search criteria. Several studies showed good intra- and inter-rater reliability for measurements taken directly on the persons (e.g., goniometer, inclinometer, flexible curve and tape measurement) or from photographs, but the validity of these measurements was not always demonstrated. Conclusion. Taking measurements of all body angles directly on the person is a lengthy process and may affect the reliability of the measurements. Measurement of body angles from photographs may be the most accurate and rapid way to assess global posture quantitatively in a clinical setting.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A sizeable amount of the testing in eye care, requires either the identification of targets such as letters to assess functional vision, or the subjective evaluation of imagery by an examiner. Computers can render a variety of different targets on their monitors and can be used to store and analyse ophthalmic images. However, existing computing hardware tends to be large, screen resolutions are often too low, and objective assessments of ophthalmic images unreliable. Recent advances in mobile computing hardware and computer-vision systems can be used to enhance clinical testing in optometry. High resolution touch screens embedded in mobile devices, can render targets at a wide variety of distances and can be used to record and respond to patient responses, automating testing methods. This has opened up new opportunities in computerised near vision testing. Equally, new image processing techniques can be used to increase the validity and reliability of objective computer vision systems. Three novel apps for assessing reading speed, contrast sensitivity and amplitude of accommodation were created by the author to demonstrate the potential of mobile computing to enhance clinical measurement. The reading speed app could present sentences effectively, control illumination and automate the testing procedure for reading speed assessment. Meanwhile the contrast sensitivity app made use of a bit stealing technique and swept frequency target, to rapidly assess a patient’s full contrast sensitivity function at both near and far distances. Finally, customised electronic hardware was created and interfaced to an app on a smartphone device to allow free space amplitude of accommodation measurement. A new geometrical model of the tear film and a ray tracing simulation of a Placido disc topographer were produced to provide insights on the effect of tear film breakdown on ophthalmic images. Furthermore, a new computer vision system, that used a novel eye-lash segmentation technique, was created to demonstrate the potential of computer vision systems for the clinical assessment of tear stability. Studies undertaken by the author to assess the validity and repeatability of the novel apps, found that their repeatability was comparable to, or better, than existing clinical methods for reading speed and contrast sensitivity assessment. Furthermore, the apps offered reduced examination times in comparison to their paper based equivalents. The reading speed and amplitude of accommodation apps correlated highly with existing methods of assessment supporting their validity. Their still remains questions over the validity of using a swept frequency sine-wave target to assess patient’s contrast sensitivity functions as no clinical test provides the range of spatial frequencies and contrasts, nor equivalent assessment at distance and near. A validation study of the new computer vision system found that the authors tear metric correlated better with existing subjective measures of tear film stability than those of a competing computer-vision system. However, repeatability was poor in comparison to the subjective measures due to eye lash interference. The new mobile apps, computer vision system, and studies outlined in this thesis provide further insight into the potential of applying mobile and image processing technology to enhance clinical testing by eye care professionals.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective To evaluate the reliability of two- and three-dimensional ultrasonographic measurement of the thickness of the lower uterine segment (LUS) in pregnant women by transvaginal and transabdominal approaches. Methods This was a study of 30 pregnant women who bad bad at least one previous Cesarean section and were between 36 and 39 weeks` gestation, with singleton pregnancies in cephalic presentation. Sonographic examinations were performed by two observers using both 4-7-MHz transabdominal and 5-8-MHz transvaginal volumetric probes. LUS measurements were performed using two- and three-dimensional ultrasound, evaluating the entire LUS thickness transabdominally and the LUS muscular thickness transvaginally. Each observer measured the LUS four times by each method. Reliability was analyzed by comparing the mean of the absolute differences, the intraclass correlation coefficients, the 95% limits of agreement and the proportion of differences <1 mm. Results Transvaginal ultrasound provided greater reliability in LUS measurements than did transabdominal ultrasound. The use of three-dimensional ultrasound improved significantly the reliability of the LUS muscular thickness measurement obtained transvaginally. Conclusions Ultrasonographic measurement of the LUS muscular thickness transvaginally appears more reliable than does that of the entire LUS thickness transabdominally. The use of three-dimensional ultrasound should be considered to improve measurement reliability. Copyright (c) 2009 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Os métodos clínicos que são realizados com recurso a tecnologias de imagiologia têm registado um aumento de popularidade nas últimas duas décadas. Os procedimentos tradicionais usados em cirurgia têm sido substituídos por métodos minimamente invasivos de forma a conseguir diminuir os custos associados e aperfeiçoar factores relacionados com a produtividade. Procedimentos clínicos modernos como a broncoscopia e a cardiologia são caracterizados por se focarem na minimização de acções invasivas, com os arcos em ‘C’ a adoptarem um papel relevante nesta área. Apesar de o arco em ‘C’ ser uma tecnologia amplamente utilizada no auxílio da navegação em intervenções minimamente invasivas, este falha na qualidade da informação fornecida ao cirurgião. A informação obtida em duas dimensões não é suficiente para proporcionar uma compreensão total da localização tridimensional da região de interesse, revelando-se como uma tarefa essencial o estabelecimento de um método que permita a aquisição de informação tridimensional. O primeiro passo para alcançar este objectivo foi dado ao definir um método que permite a estimativa da posição e orientação de um objecto em relação ao arco em ‘C’. De forma a realizar os testes com o arco em ‘C’, a geometria deste teve que ser inicialmente definida e a calibração do sistema feita. O trabalho desenvolvido e apresentado nesta tese foca-se num método que provou ser suficientemente sustentável e eficiente para se estabelecer como um ponto de partida no caminho para alcançar o objectivo principal: o desenvolvimento de uma técnica que permita o aperfeiçoamento da qualidade da informação adquirida com o arco em ‘C’ durante uma intervenção clínica.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Optical immersion clearing is a technique that has been widely studied for more than two decades and that is used to originate a temporary transparency effect in biological tissues. If applied in cooperation with clinical methods it provides optimization of diagnosis and treatment procedures. This technique turns biological tissues more transparent through two main mechanisms — tissue dehydration and refractive index (RI) matching between tissue components. Such matching is obtained by partial replacement of interstitial water by a biocompatible agent that presents higher RI and it can be completely reversible by natural rehydration in vivo or by assisted rehydration in ex vivo tissues. Experimental data to characterize and discriminate between the two mechanisms and to find new ones are necessary. Using a simple method, based on collimated transmittance and thickness measurements made from muscle samples under treatment, we have estimated the diffusion properties of glucose, ethylene glycol (EG) and water that were used to perform such characterization and discrimination. Comparing these properties with data from literature that characterize their diffusion in water we have observed that muscle cell membrane permeability limits agent and water diffusion in the muscle. The same experimental data has allowed to calculate the optical clearing (OC) efficiency and make an interpretation of the internal changes that occurred in muscle during the treatments. The same methodology can now be used to perform similar studies with other agents and in other tissues in order to solve engineering problems at design of inexpensive and robust technologies for a considerable improvement of optical tomographic techniques with better contrast and in-depth imaging.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Mild cognitive impairment (MCI) has been defined as a transitional state between normal aging and dementia. In many cases, MCI represents an early stage of developing cognitive impairment. Patients diagnosed with MCI do not meet the criteria for dementia as their general intellect and everyday activities are preserved, although minor changes in instrumental activities of daily living (ADL) may occur. However, they may exhibit significant behavioral and psychological signs and symptoms (BPS), also frequently observed in patients with Alzheimer's disease (AD). Hence, we wondered to what extent specific BPS are associated with cognitive decline in participants with MCI or AD. METHODS: Our sample consisted of 164 participants, including 46 patients with amnestic (single or multi-domain) MCI and 54 patients with AD, as well as 64 control participants without cognitive disorders. Global cognitive performance, BPS, and ADL were assessed using validated clinical methods at baseline and at two-year follow-up. RESULTS: The BPS variability over the follow-up period was more pronounced in the MCI group than in patients with AD: some BPS improve, others occur newly or worsen, while others still remain unchanged. Moreover, specific changes in BPS were associated with a rapid deterioration of the global cognitive level in MCI patients. In particular, an increase of euphoria, eating disorders, and aberrant motor behavior, as well as worsened sleep quality, predicted a decline in cognitive functioning. CONCLUSIONS: Our findings confirm a higher variability of BPS over time in the MCI group than in AD patients. Moreover, our results provide evidence of associations between specific BPS and cognitive decline in the MCI group that might suggest a risk of conversion of individuals with amnestic MCI to AD.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The reference intervals for biochemical variables and red blood cell indices of healthy intensively bred channel catfish Ictalurus punctatus were determined. The blood variables were determined using standardized clinical methods. The reference intervals (25th and 75th percentiles) were established using a non-parametric method. Reference intervals for plasma glucose, serum total protein, sodium, potassium, calcium, magnesium, chloride concentration, primary and secondary red blood cell indices were established. The haematological and biochemical reference intervals established may allow important clinical decisions about channel catfish. (c) 2007 the Authors Journal compilation (C) 2007 the Fisheries Society of the British Isles.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To compare a single intraoperative sub-Tenon's capsule triamcinolone acetonicle injection with steroid drops in the treatment of ocular inflammation after cataract surgery.Design: Randomized, double-masked controlled trial.Participants: A total of 100 patients were randomized prospectively into 2 groups: 50 patients treated with 1% prednisolone eyedrops (control group A) and 50 patients treated with sub-Tenon's capsule triamcinolone (treatment group B).Methods: All patients underwent phacoemulsification and intraocular posterior lens implantation. After surgery, patients were randomized to receive either (group B) an intraoperative 40 mg triamcinolone acetonicle sub-Tenon's capsule injection or (group A) 1% prednisolone acetate eyedrops, according to the following schedule: 1 drop 4 times daily (week 1), 3 times daily (week 2), 2 times daily (week 3), once daily (week 4). To mask the study, group B received vehicle drops administered on a similar schedule, and group A received an intraoperative sub-Tenon's capsule injection of a 1 ml balanced salt solution.Main Outcome Measures: the main outcome measures included inflammation (cell, flare, ciliary flush), intraocular pressure, and lack of response.Results: Triamcinolone was shown to have anti-inflammatory efficacy clinically equivalent to conventional 1% prednisolone eyedrops in reducing intraocular inflammation, as measured by clinical methods. Triamcinolone was found to be as safe as the prednisolone in terms of adverse effects, changes in visual acuity, intraocular pressure, and biomicroscopic and ophthalmoscopic variables. on the third, seventh, fourteenth, and twenty-eighth postoperative days, a significantly lower intraocular pressure (P<0.01) was noted in the triamcinolone group than in the prednisolone group.Conclusions: A single intraoperative 40-mg triamcinolone acetonide sub-Tenon's capsule injection demonstrated a clinically equivalent therapeutic response and ocular tolerance compared with 1% prednisolone drops in controlling postoperative inflammation after uncomplicated cataract surgery and merits further investigation. (C) 2004 by the American Academy of Ophthalmology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

C-reactive protein (CRP) is an acute phase protein whose levels are increased in many disorders. There exists, in particular, a great deal of interest in the correlation between blood serum levels and the severity of risk for cardiovascular disease. A sensitive, label-free, non-amplified and reusable electrochemical impedimetric biosensor for the detection of CRP in blood serum was developed herein based on controlled and coverage optimised antibody immobilization on standard polycrystalline gold electrodes. Charge transfer resistance changes were highly target specific, linear with log. CRP. concentration across a 0.5-50. nM range and associated with a limit of detection of 176. pM. Significantly, the detection limits are better than those of current CRP clinical methods and the assays are potentially cheap, relatively automated, reusable, multiplexed and highly portable. The generated interfaces were capable not only of comfortably quantifying CRP across a clinically relevant range of concentrations but also of doing this in whole blood serum with interfaces that were, subsequently, reusable. The importance of optimising receptor layer resistance in maximising assay sensitivity is also detailed. © 2012.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In view of the growing prevalence of Alzheimer's disease (AD) worldwide, there is an urgent need for the development of better diagnostic tools and more effective therapeutic interventions. At the earliest stages of AD, no significant cognitive or functional impairment is detected by conventional clinical methods. However, new technologies based on structural and functional neuroimaging, and on the biochemical analysis of cerebrospinal fluid (CSF) may reveal correlates of intracerebral pathology in individuals with mild, predementia symptoms. These putative correlates are commonly referred to as AD-related biomarkers. The relevance of the early diagnosis of AD relies on the hypothesis that pharmacological interventions with disease-modifying compounds are likely to produce clinically relevant benefits if started early enough in the continuum towards dementia. Here we review the clinical characteristics of the prodromal and transitional states from normal cognitive ageing to dementia in AD. We further address recent developments in biomarker research to support the early diagnosis and prediction of dementia, and point out the challenges and perspectives for the translation of research data into clinical practice.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Lumbar discectomy is the surgical procedure most frequently performed for patients suffering from low back pain and sciatica. Disc herniation as a consequence of degenerative or traumatic processes is commonly encountered as the underlying cause for the painful condition. While discectomy provides favourable outcome in a majority of cases, there are conditions where unmet requirements exist in terms of treatment, such as large disc protrusions with minimal disc degeneration; in these cases, the high rate of recurrent disc herniation after discectomy is a prevalent problem. An effective biological annular repair could improve the surgical outcome in patients with contained disc herniations but otherwise minor degenerative changes. An attractive approach is a tissue-engineered implant that will enable/stimulate the repair of the ruptured annulus. The strategy is to develop three-dimensional scaffolds and activate them by seeding cells or by incorporating molecular signals that enable new matrix synthesis at the defect site, while the biomaterial provides immediate closure of the defect and maintains the mechanical properties of the disc. This review is structured into (1) introduction, (2) clinical problems, current treatment options and needs, (3) biomechanical demands, (4) cellular and extracellular components, (5) biomaterials for delivery, scaffolding and support, (6) pre-clinical models for evaluation of newly developed cell- and material-based therapies, and (7) conclusions. This article highlights that an interdisciplinary approach is necessary for successful development of new clinical methods for annulus fibrosus repair. This will benefit from a close collaboration between research groups with expertise in all areas addressed in this review.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Vol. 1: 2nd impression with correction and additions, Apr., 1938.