958 resultados para Clinical analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Children who have suffered physical or sexual abuse are as vulnerable as adult trauma victims to experience "secondary trauma", in which the reactions of the family or broader system exacerbate the child's difficulties. Three clinical cases (a 7 yr old male, an 8 yr old male, and a 7 yr old female) are presented that suggest that this secondary trauma can be made worse by either excessive or insufficient provision of individual child psychotherapy, and the way the system interprets and reacts to these clinical decisions. Types of secondary trauma and their interactions with clinical decisions are discussed. Ways of framing clinical decisions to minimize the potential secondary trauma are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Successful fertilization depends upon the activation of metaphase II arrested oocytes by sperm-borne oocyte activating factor (SOAF). Failure of oocyte activation is considered as the cause of treatment failure in a proportion of infertile couples. SOAF induces the release of intracellular calcium in oocyte which leads to meiotic resumption and pronuclear formation. Calcium release is either in the form of single calcium transient in echinoderm and amphibian oocytes or several calcium oscillations in ascidian and mammalian oocytes. Although the SOAF attributes are established, it is not clear which sperm protein(s) play such role. Sperm postacrosomal WW binding protein (PAWP) satisfies a developmental criteria set for a candidate SOAF. This study shows that recombinant human PAWP protein or its transcript acts upstream of calcium release and fully activates the amphibian and mammalian oocytes. Interference trials provided evidence for the first time that PAWP mediates sperm-induced intracellular calcium release through a PPXY/WWI domain module in Xenopus, mouse and human oocytes. Clinical applications of PAWP were further investigated by prospective study on the sperm samples from patients undergoing intracytoplasmic sperm injection (ICSI). PAWP expression level, analyzed by flow cytometry, was correlated to ICSI success rate and embryonic development. This study also explored the developmental expression of the other SOAF candidate, PLCζ in male reproductive system and its function during fertilization. Our findings showed for the first time that PLCζ most likely binds to the sperm head surface during epididymal passage and is expressed in epididymis. We demonstrated that PLCζ is also compartmentalized early in spermiogenesis and thus could play an important role during spermiogenesis. Detailed analysis of in vitro fertilization revealed that PLCζ disappears from sperm head during acrosome reaction and is not detectable during sperm incorporation into the oocyte cytoplasm. In conclusion, this dissertation provides evidence for the essential non-redundant role of sperm PAWP in amphibian and mammalian fertilization; recommends PAWP as a biomarker for prediction of ICSI outcomes in infertile couples; and proposes that sperm PLCζ may have functions other than inducing oocyte activation during fertilization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La reconstruction en deux étapes par expanseur et implant est la technique la plus répandue pour la reconstruction mammmaire post mastectomie. La formation d’une capsule périprothétique est une réponse physiologique universelle à tout corps étranger présent dans le corps humain; par contre, la formation d’une capsule pathologique mène souvent à des complications et par conséquent à des résultats esthétiques sous-optimaux. Le microscope électronique à balayage (MEB) est un outil puissant qui permet d’effectuer une évaluation sans pareille de la topographie ultrastructurelle de spécimens. Le premier objectif de cette thèse est de comparer le MEB conventionnel (Hi-Vac) à une technologie plus récente, soit le MEB environnemental (ESEM), afin de déterminer si cette dernière mène à une évaluation supérieure des tissus capsulaires du sein. Le deuxième objectif est d‘appliquer la modalité de MEB supérieure et d’étudier les modifications ultrastructurelles des capsules périprothétiques chez les femmes subissant différents protocoles d’expansion de tissus dans le contexte de reconstruction mammaire prothétique. Deux études prospectives ont été réalisées afin de répondre à nos objectifs de recherche. Dix patientes ont été incluses dans la première, et 48 dans la seconde. La modalité Hi-Vac s’est avérée supérieure pour l’analyse compréhensive de tissus capsulaires mammaires. En employant le mode Hi-Vac dans notre protocole de recherche établi, un relief 3-D plus prononcé à été observé autour des expanseurs BIOCELL® dans le groupe d’approche d’intervention retardée (6 semaines). Des changements significatifs n’ont pas été observés au niveau des capsules SILTEX® dans les groupes d’approche d’intervention précoce (2 semaines) ni retardée.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La reconstruction en deux étapes par expanseur et implant est la technique la plus répandue pour la reconstruction mammmaire post mastectomie. La formation d’une capsule périprothétique est une réponse physiologique universelle à tout corps étranger présent dans le corps humain; par contre, la formation d’une capsule pathologique mène souvent à des complications et par conséquent à des résultats esthétiques sous-optimaux. Le microscope électronique à balayage (MEB) est un outil puissant qui permet d’effectuer une évaluation sans pareille de la topographie ultrastructurelle de spécimens. Le premier objectif de cette thèse est de comparer le MEB conventionnel (Hi-Vac) à une technologie plus récente, soit le MEB environnemental (ESEM), afin de déterminer si cette dernière mène à une évaluation supérieure des tissus capsulaires du sein. Le deuxième objectif est d‘appliquer la modalité de MEB supérieure et d’étudier les modifications ultrastructurelles des capsules périprothétiques chez les femmes subissant différents protocoles d’expansion de tissus dans le contexte de reconstruction mammaire prothétique. Deux études prospectives ont été réalisées afin de répondre à nos objectifs de recherche. Dix patientes ont été incluses dans la première, et 48 dans la seconde. La modalité Hi-Vac s’est avérée supérieure pour l’analyse compréhensive de tissus capsulaires mammaires. En employant le mode Hi-Vac dans notre protocole de recherche établi, un relief 3-D plus prononcé à été observé autour des expanseurs BIOCELL® dans le groupe d’approche d’intervention retardée (6 semaines). Des changements significatifs n’ont pas été observés au niveau des capsules SILTEX® dans les groupes d’approche d’intervention précoce (2 semaines) ni retardée.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Visual perception is dependent on both light transmission through the eye and neuronal conduction through the visual pathway. Advances in clinical diagnostics and treatment modalities over recent years have increased the opportunities to improve the optical path and retinal image quality. Higher order aberrations and retinal straylight are two major factors that influence light transmission through the eye and ultimately, visual outcome. Recent technological advancements have brought these important factors into the clinical domain, however the potential applications of these tools and considerations regarding interpretation of data are much underestimated. The purpose of this thesis was to validate and optimise wavefront analysers and a new clinical tool for the objective evaluation of intraocular scatter. The application of these methods in a clinical setting involving a range of conditions was also explored. The work was divided into two principal sections: 1. Wavefront Aberrometry: optimisation, validation and clinical application The main findings of this work were: • Observer manipulation of the aberrometer increases variability by a factor of 3. • Ocular misalignment can profoundly affect reliability, notably for off-axis aberrations. • Aberrations measured with wavefront analysers using different principles are not interchangeable, with poor relationships and significant differences between values. • Instrument myopia of around 0.30D is induced when performing wavefront analysis in non-cyclopleged eyes; values can be as high as 3D, being higher as the baseline level of myopia decreases. Associated accommodation changes may result in relevant changes to the aberration profile, particularly with respect to spherical aberration. • Young adult healthy Caucasian eyes have significantly more spherical aberration than Asian eyes when matched for age, gender, axial length and refractive error. Axial length is significantly correlated with most components of the aberration profile. 2. Intraocular light scatter: Evaluation of subjective measures and validation and application of a new objective method utilising clinically derived wavefront patterns. The main findings of this work were: • Subjective measures of clinical straylight are highly repeatable. Three measurements are suggested as the optimum number for increased reliability. • Significant differences in straylight values were found for contact lenses designed for contrast enhancement compared to clear lenses of the same design and material specifications. Specifically, grey/green tints induced significantly higher values of retinal straylight. • Wavefront patterns from a commercial Hartmann-Shack device can be used to obtain objective measures of scatter and are well correlated with subjective straylight values. • Perceived retinal stray light was similar in groups of patients implanted with monofocal and multi focal intraocular lenses. Correlation between objective and subjective measurements of scatter is poor, possibly due to different illumination conditions between the testing procedures, or a neural component which may alter with age. Careful acquisition results in highly reproducible in vivo measures of higher order aberrations; however, data from different devices are not interchangeable which brings the accuracy of measurement into question. Objective measures of intraocular straylight can be derived from clinical aberrometry and may be of great diagnostic and management importance in the future.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Hypereosinophilic syndrome (HES) is a heterogeneous group of rare disorders defined by persistent blood eosinophilia > or =1.5 x 10(9)/L, absence of a secondary cause, and evidence of eosinophil-associated pathology. With the exception of a recent multicenter trial of mepolizumab (anti-IL-5 mAb), published therapeutic experience has been restricted to case reports and small case series. OBJECTIVE: The purpose of the study was to collect and summarize baseline demographic, clinical, and laboratory characteristics in a large, diverse cohort of patients with HES and to review responses to treatment with conventional and novel therapies. METHODS: Clinical and laboratory data from 188 patients with HES, seen between January 2001 and December 2006 at 11 institutions in the United States and Europe, were collected retrospectively by chart review. RESULTS: Eighteen of 161 patients (11%) tested were Fip1-like 1-platelet-derived growth factor receptor alpha (FIP1L1-PDGFRA) mutation-positive, and 29 of 168 patients tested (17%) had a demonstrable aberrant or clonal T-cell population. Corticosteroid monotherapy induced complete or partial responses at 1 month in 85% (120/141) of patients with most remaining on maintenance doses (median, 10 mg prednisone equivalent daily for 2 months to 20 years). Hydroxyurea and IFN-alpha (used in 64 and 46 patients, respectively) were also effective, but their use was limited by toxicity. Imatinib (used in 68 patients) was more effective in patients with the FIP1L1-PDGFRA mutation (88%) than in those without (23%; P < .001). CONCLUSION: This study, the largest clinical analysis of patients with HES to date, not only provides useful information for clinicians but also should stimulate prospective trials to optimize treatment of HES.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We described here a new method for the determination of total calcium in plasma. The method is based on the precipitation of calcium with excess oxalate and the measurement of residual oxalate by flow injection analysis with Ru(bpy)(3)(2+) electrochemiluminescent detection. It has the advantages of extremely stable reagent, user-friendly instrument, high selectivity, good analytical recovery, wide dynamic range, and nice correlation with atomic absorption spectroscopy. The calibration plot for calcium is linear over a concentration range from 0.5 mmol L-1 to 4.8 mmol L-1, which is wider than those obtained by most other methods. The analytical recoveries for plasma calcium are 98.4-101.2% with coefficients of variation (CVs) of 1.96-2.52%. The within-day CVs range from 0.76% to 0.95%, and between-day CVs were from 1.12% to 1.46%. The time for each injection is one minute. Because the proposed method can be readily carried out on increasingly popular instruments for Ru(bpy)(3)(2+) ECL immunoassays and DNA probe assays, Ru(bpy)32+ ECL method is suitable for routine clinical analysis of calcium.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this paper, we propose a multispectral analysis system using wavelet based Principal Component Analysis (PCA), to improve the brain tissue classification from MRI images. Global transforms like PCA often neglects significant small abnormality details, while dealing with a massive amount of multispectral data. In order to resolve this issue, input dataset is expanded by detail coefficients from multisignal wavelet analysis. Then, PCA is applied on the new dataset to perform feature analysis. Finally, an unsupervised classification with Fuzzy C-Means clustering algorithm is used to measure the improvement in reproducibility and accuracy of the results. A detailed comparative analysis of classified tissues with those from conventional PCA is also carried out. Proposed method yielded good improvement in classification of small abnormalities with high sensitivity/accuracy values, 98.9/98.3, for clinical analysis. Experimental results from synthetic and clinical data recommend the new method as a promising approach in brain tissue analysis.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Rocha AL, Shirasu BK, Hayacibara RM, Magro-Filho O, Zanoni JN, Araujo MG. Clinical and histological evaluation of subepithelial connective tissue after collagen sponge implantation in the human palate. J Periodont Res 2012; 47: 758765. (c) 2012 John Wiley & Sons A/S Background and Objective: Successful root-coverage treatment depends on the thickness of the donor tissue. This study aimed to evaluate the thickness of donor tissue after augmentation of the connective tissue in the palatal area by implantation of lyophilized collagen sponge (Hemospon (R)). Material and Methods: Ten patients with an indication for root coverage, whose palate was deficient in adequate connective tissue, were recruited. The procedure was carried out in two stages. In the first stage, the palatal thickness in the donor site was measured at three standardized points (points 1, 2 and 3), from the distal of the canine to the distal of the first molar, and the lyophilized collagen sponge was inserted. In the second stage, the palatal thickness over the implant was measured (at points 1, 2 and 3), two biopsies of the palatal mucosa were collected one over the implant (experimental sample) and the other on the contralateral side (control sample) and then root-coverage treatment was performed. Analyses consisted of clinical assessment of the palatal measurements before and after sponge implantation, and histological assessment of the experimental and control biopsy samples. Data were analyzed using the Wilcoxon test. Results: Both analyses showed a significant increase in mean thickness, of 1.08 mm of neoformed tissue in the clinical analysis (the tissue at point 2 was the thickest of the three points) and of 0.53 mm in the histological analysis. Conclusion: The insertion of lyophilized collagen sponge induced a significant increase in the thickness of palatal connective tissue.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In the period from July 2009 to October 2010, fecal samples from 61 animals and 154 humans from the municipality of Aracatuba (São Paulo State, Brazil) were studied. Fecal samples from animals were collected in the Municipal Animal Shelter and the Veterinary Hospital of the Universidade Estadual Paulista. Human fecal specimens were collected in playschools in the outskirts of the city by the private network of clinical analysis laboratories of the municipal. Diagnosis was done by optical microscopy using the Faust and Hoffmann, Pons and Janer techniques. The genotypes of Giardia intestinalis were characterized by PCR-RFLP and confirmed by sequencing the ß-giardin gene. Human specimens were positive in 25.3% (39/154) of the cases with 26.8% (36/134) of the specimens from children and 15% (3/20) from adults being positive. The frequency of G. intestinalis among the animals was 23.0% (14/61). A total of 32 isolates of G. intestinalis obtained from human feces and six from dogs and cats were characteristic of the A genotype (AI and AII/AIII). The results of this study in respect to frequency of giardiasis are similar to reported in most studies in Brazil. The prevalence observed in animal populations conforms to worldwide infection rates. G. intestinalis genotypes considered zoonotic were detected in both pets and humans from the city of Aractuba, suggesting a possible zoonotic transmission of the parasite in the northwestern region of São Paulo State. The absence of these genotypes in farm animals may imply that they are not involved in the chain of transmission to humans in this region.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The purpose of this study was to warn the dental community about a possible problem in function with partial implant-supported prostheses used for long periods. The misalignment between natural teeth and the implant-supported prosthesis on teeth 11 and 12, observed in a 14-year clinical follow-up, illustrates the fact. The metal-ceramic crowns were placed in 1995 after a rigorous occlusal adjustment. Evaluations were made at 4, 6, 9, and 14 years, when it was noticed that the restorations were positioned palatally and extruded in comparison with the natural teeth. After 9 years, a greater discrepancy was noticed, with anterior occlusion and esthetic changes. The possible causes have been discussed: occlusal problems, parafunctional habits, and natural movement. The first 2 options were discarded after clinical analysis and diagnosis. Therefore, the natural movement probably deriving from an interaction of mechanical and genetic factors might have been the cause. The implants do not have periodontal ligaments but rather ankylosis, so they do not suffer those movements. This case emphasizes the need to inform patients that implants can last more than 10 years in function, but this is not the case with restorations, which lose function and esthetics and must be replaced.