5 resultados para Cleanroom
Resumo:
Many business-oriented software applications are subject to frequent changes in requirements. This paper shows that, ceteris paribus, increases in the volatility of system requirements decrease the reliability of software. Further, systems that exhibit high volatility during the development phase are likely to have lower reliability during their operational phase. In addition to the typically higher volatility of requirements, end-users who specify the requirements of business-oriented systems are usually less technically oriented than people who specify the requirements of compilers, radar tracking systems or medical equipment. Hence, the characteristics of software reliability problems for business-oriented systems are likely to differ significantly from those of more technically oriented systems.
Resumo:
Puhdastilojen suunnittelussa pyritään saamaan hallittu ja valvottu ilmanpuhtaus luokiteltuun tilaan.Luokittelu tapahtuu puhdastilastandardeilla, lisäksi lääkevalmisteita valmistettavassa tilassa GMP -säädösten mukaisin luokituksin. Puhdastilastandardi ISO 14644 käsittää seitsemän osaa, jossa on käsitelty puhdastilaa koskevia määräyksiä suunnittelusta käyttöön ja testaukseen. GMP-säädökset sisältävät yhdeksän kappaletta, joista kappale 3: 'Tilat ja laitteet' on keskeinen osa lääkeainevalmistuksen puhdastilasuunnittelua. Puhtaan ilman aikaansaamiseksi puhdastilaan merkittävimmät roolit ovat ilmanvaihdolla, puhdastilarakenteilla ja rakennusautomaatiolla. Ilma voidaan tuoda tilaan kolmella eri periaatteella. Ilmaa tuodaan tilaan yhdensuuntaisesti, turbulenttisesti tai sekavirtauksena HEPA -suodattimien kautta, joilla varmistetaan epäpuhtauksien korkea suodatusaste. Ilmapoistetaan rei'itettyjen, korotettujen lattioiden kautta tai tilan alaosassa olevien poistoilmasäleikköjen kautta, josta se johdetaan noin 75-90%:sti kierrätettynä takaisin tilaan. Lääketeollisuudessa rei'itettyjä, korotettuja lattioita eivoida käyttää kontaminaatiovaaran, vuoksi. Tilaan suunniteltuja olosuhteita ylläpidetään rakennusautomaation avulla ja monitorointijärjestelmällä valvotaan tilassa olevan ilman laatua. Kaikki GMP-luokituksen mukaiset puhdastilat tulee validoida. Validointiin kuuluu teknisten järjestelmien kvalifiointi ja koko prosessin validointi. Teknisten järjestel-mien kvalifiointi käsittää suunnitelmien tarkastuksen (DQ), asennus - ja käyttöönotto tarkastukset (IQ), toiminnan testauksen (OQ) ja suorituksen testauksen (PQ). Kvali-fiointi kuuluu yhtenä osa-alueena validointiin. Prosessin validointi on osa yrityksen laadunvarmistusta. Validoinnilla hankitaan dokumentoidut todisteet siitä, että tila tai prosessi todella täyttää annetut vaatimukset. Tässä työssä laadittiin esimerkinomainen kvalifiointisuunnitelma puhdastilan tekni-sille järjestelmille. Suunnitelma sisältää asennus- ja käyttöönoton mukaiset tarkastukset (IQ)ja toiminnan aikaiset testaukset (OQ).
Resumo:
Tesi in azienda che verte sugli impianti di ripartizione di farmaci in asepsi e atmosfera controllata. Sono stati analizzati: norme riguardanti progettazione e installazione di impianti farmaceutici; tecnologie di ripartizione (isolatori e RABS) con riferimento all'isolatore in azienda e all'impianto HVAC asservito; la linea di ripartizione in generale (washing machine - tunnel di depirogenazione - isolatore - coding station); test SAT di convalida per l'installazione di isolatore e impianto HVAC; sviluppo e convalida del ciclo di decontaminazione con VHP; conti di ottimizzazione dell'inertizzazione della camera di riempimento.
Resumo:
Intracochlear trauma from surgical insertion of bulky electrode arrays and inadequate pitch perception are areas of concern with current hand-assembled commercial cochlear implants. Parylene thin-film arrays with higher electrode densities and lower profiles are a potential solution, but lack rigidity and hence depend on manually fabricated permanently attached polyethylene terephthalate (PET) tubing based bulky backing devices. As a solution, we investigated a new backing device with two sub-systems. The first sub-system is a thin poly(lactic acid) (PLA) stiffener that will be embedded in the parylene array. The second sub-system is an attaching and detaching mechanism, utilizing a poly(N-vinylpyrrolidone)-block-poly(d,l-lactide) (PVP-b-PDLLA) copolymer-based biodegradable and water soluble adhesive, that will help to retract the PET insertion tool after implantation. As a proof-of-concept of sub-system one, a microfabrication process for patterning PLA stiffeners embedded in parylene has been developed. Conventional hotembossing, mechanical micromachining, and standard cleanroom processes were integrated for patterning fully released and discrete stiffeners coated with parylene. The released embedded stiffeners were thermoformed to demonstrate that imparting perimodiolar shapes to stiffener-embedded arrays will be possible. The developed process when integrated with the array fabrication process will allow fabrication of stiffener-embedded arrays in a single process. As a proof-of-concept of sub-system two, the feasibility of the attaching and detaching mechanism was demonstrated by adhering 1x and 1.5x scale PET tube-based insertion tools and PLA stiffeners embedded in parylene using the copolymer adhesive. The attached devices survived qualitative adhesion tests, thermoforming, and flexing. The viability of the detaching mechanism was tested by aging the assemblies in-vitro in phosphate buffer solution. The average detachment times, 2.6 minutes and 10 minutes for 1x and 1.5x scale devices respectively, were found to be clinically relevant with respect to the reported array insertion times during surgical implantation. Eventually, the stiffener-embedded arrays would not need to be permanently attached to current insertion tools which are left behind after implantation and congest the cochlear scala tympani chamber. Finally, a simulation-based approach for accelerated failure analysis of PLA stiffeners and characterization of PVP-b-PDLLA copolymer adhesive has been explored. The residual functional life of embedded PLA stiffeners exposed to body-fluid and thereby subjected to degradation and erosion has been estimated by simulating PLA stiffeners with different parylene coating failure types and different PLA types for a given parylene coating failure type. For characterizing the PVP-b-PDLLA copolymer adhesive, several formulations of the copolymer adhesive were simulated and compared based on the insertion tool detachment times that were predicted from the dissolution, degradation, and erosion behavior of the simulated adhesive formulations. Results indicate that the simulation-based approaches could be used to reduce the total number of time consuming and expensive in-vitro tests that must be conducted.
Resumo:
Defects of the peripheral nervous system are extremely frequent in trauma and surgeries and have high socioeconomic costs. In case of peripheral nerve injury, the first approach is primary neurorrhaphy, which is direct nerve repair with epineural microsutures of the two stumps. However, this is not feasible in case of stump retraction or in case of tissue loss (gap > 2 cm), where the main surgical options are autologous grafts, allogenic grafts, or nerve conduits. While the gold standard is the autograft, it has disadvantages related to its harvesting, with an inevitable donor site morbidity and functional deficit. Fresh nerve allografts have therefore become a viable alternative option, but they require immunosuppression, which is often contraindicated. Acellular Nerve Allografts (ANA) represent a valid alternative, they do not need immunosuppression and appear to be safe and effective based on recent studies. The purpose of this study is to propose and develop an innovative method of nerve decellularization (Rizzoli method), conforming to cleanroom requirements in order to perform the direct tissue manipulation step and the nerve decellularization process within five hours, so as to accelerate the detachment of myelin and cellular debris, without detrimental effects on nerve architecture. In this study, the safety and the efficacy of the new method are evaluated in vitro and in vivo by histological, immunohistochemical, and histomorphometric studies in rabbits and humans. The new method is rapid, safe, and cheaper if compared with available commercial ANAs. The present study shows that the method, previously optimized in vitro and in vivo on animal model presented by our group, can be applied on human nerve samples. This work represents the first step in providing a novel, safe, and inexpensive tool for use by European tissue banks to democratize the use of nerve tissue transplantation for nerve injury reconstruction.