926 resultados para Chlamydia rapid detection test


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Point-of-care (POC) tests offer potentially substantial benefits for the management of infectious diseases, mainly by shortening the time to result and by making the test available at the bedside or at remote care centres. Commercial POC tests are already widely available for the diagnosis of bacterial and viral infections and for parasitic diseases, including malaria. Infectious diseases specialists and clinical microbiologists should be aware of the indications and limitations of each rapid test, so that they can use them appropriately and correctly interpret their results. The clinical applications and performance of the most relevant and commonly used POC tests are reviewed. Some of these tests exhibit insufficient sensitivity, and should therefore be coupled to confirmatory tests when the results are negative (e.g. Streptococcus pyogenes rapid antigen detection test), whereas the results of others need to be confirmed when positive (e.g. malaria). New molecular-based tests exhibit better sensitivity and specificity than former immunochromatographic assays (e.g. Streptococcus agalactiae detection). In the coming years, further evolution of POC tests may lead to new diagnostic approaches, such as panel testing, targeting not just a single pathogen, but all possible agents suspected in a specific clinical setting. To reach this goal, the development of serology-based and/or molecular-based microarrays/multiplexed tests will be needed. The availability of modern technology and new microfluidic devices will provide clinical microbiologists with the opportunity to be back at the bedside, proposing a large variety of POC tests that will allow quicker diagnosis and improved patient care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Rapid diagnostic tests (RDTs) may improve the early detection of visceral leishmaniasis (VL), but their real-world performance requires additional study. Therefore, we evaluated the performance of an rK39-based RDT (Kalazar Detect™) for the detection of VL in an endemic, large urban area. Methods Data were collected from a registry of rK39 RDT performed at 11 emergency care units in Belo Horizonte, Brazil, and from a national database of reportable communicable diseases of the Sistema de Informação de Agravos de Notificação (SINAN). Results The rapid rK39 test was performed in 476 patients, with 114 (23.9%) positive results. The analysis of rK39 RDT performance was based on 381 (80%) cases reported to the SINAN database, of which 145 (38.1%) were confirmed cases. Estimates for sensitivity and specificity were 72.4% (95% CI: 64.6-79%) and 99.6% (95%CI: 97.6-99.9%), respectively. Positive and negative predictive values were estimated at 99.1% (95%CI: 94.9-99.8%) and 85.5% (95%CI: 80.8-89.1%), respectively. In addition, close agreement between the rK39 RDT and indirect immunofluorescence was observed. Conclusions In summary, the rK39 RDT showed a high specificity but only moderate sensitivity. In endemic areas for VL, treatment may be considered in cases with clinical manifestations and a positive rK39 RDT, but those with a negative test should be subjected to further investigation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid conglutination test (RCT) with performance comparable to the indirect fluorescent antibody technique (IFAT) was developed to detect antibodies against Babesia bigemina (B. bigemina-RCT). The B. bigemina-RCT is a sensitive, specific, economical, and rapidly performed serological test suitable for field application or minimally equipped laboratories. This test had a sensitivity of 90.9%, and specificity of 97.6%, compared to IFAT, which showed for the same parameters respectively, 98.3% and 99.7%. The early detection of anti- B. bigemina immunoglobulins by RCT in experimental infections was nearly parallel to that of IFAT. Cross reactions were observed with sera from calves experimentally infected with Babesia bovis (1.8%) and with Anaplasma marginale (1.2%). RCT antigen prepared with non parasitized erythrocytes (negative antigen) showed 1.5%, 3.5% and 2.2% of positive reactions with sera from animals experimentally infected with B. bigemina, B. bovis and A. marginale. However, none of the sera from animals of endemic areas for babesia infection resulted in positive reactions with the negative antigen. Considering these results and shelf life over six months, the B. bigemina-RCT could be used for epidemiological surveys and evaluation of control measures against this species of Babesia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The widespread falsification and/or adulteration of commercially available pharmaceutical preparations call for reliable methods of drug identification, preferably through selective and rapid sorting color tests that could be undertaken with minimum equipment remote from laboratory facilities. The present work deals with a convenient adaptation and refinement of a spot test devised by Feigl (1966) for urotropine, based on the hydrolytic cleavage of that substance in the presence of sulfuric acid, splitting out formaldehyde which is identified by its color reaction with chromotropic acid. A simple emergency kit was developed for the quick, efficient, inexpensive and easy performance of urotropine tests by semiskilled personnel even in the drugstore laboratory (or office) as well as in a mobile screening operation. It is shown that when the reagents are added according to the recommended sequence a self-heating system is generated, increasing substantially the reactions' rates and the test sensitivity as well. The identification limit found was 25 mug of urotropine, for both solid and liquid samples. The possible interference of 84 substances/materials was investigated. Interference was noted only for methylene blue, acriflavine, Ponceau Red, Bordeaux Red (these dyes are often included in urotropine dosage forms), pyramidone, dipyrone, quinine and tetracycline. A simple procedure for removing most of the interferences is described. Data for 8 commercial dosage forms and results obtained from their analysis are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Protein A containing Staphylococcus aureus was used to develop a coagglutination (COA) test for the detection and typing of foot and mouth disease virus (FMDV) O, A and C serotypes in infected cells and tissues. Different batches and amounts of guinea pig anti-FMDV sera were assessed to optimize the preparation of COA conjugates. The sensitivity and specificity of the COA Test for the detection of FMDV O, A and C serotypes and heterologous viruses was also characterized. Comparison between the COA Test and complement fixation test for the detection and typing of FMDV obtained from extracts of tongue epithelial tissues from infected cattle revealed high agreement in the results and indicated a potential application of the COA Test for the direct diagnosis of viruses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the impact of the routine use of rapid antigen detection test in the diagnosis and treatment of acute pharyngotonsillitis in children. METHODS: This is a prospective and observational study, with a protocol compliance design established at the Emergency Unit of the University Hospital of Universidade de São Paulo for the care of children and adolescents diagnosed with acute pharyngitis. RESULTS: 650 children and adolescents were enrolled. Based on clinical findings, antibiotics would be prescribed for 389 patients (59.8%); using the rapid antigen detection test, they were prescribed for 286 patients (44.0%). Among the 261 children who would not have received antibiotics based on the clinical evaluation, 111 (42.5%) had positive rapid antigen detection test. The diagnosis based only on clinical evaluation showed 61.1% sensitivity, 47.7% specificity, 44.9% positive predictive value, and 57.5% negative predictive value. CONCLUSIONS: The clinical diagnosis of streptococcal pharyngotonsillitis had low sensitivity and specificity. The routine use of rapid antigen detection test led to the reduction of antibiotic use and the identification of a risk group for complications of streptococcal infection, since 42.5% positive rapid antigen detection test patients would not have received antibiotics based only on clinical diagnosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE Group B streptococci (GBS) may lead to early onset neonatal sepsis with severe morbidity and mortality of newborns. Intrapartum detection of GBS is needed. The objective was to compare a PCR-based test performed in the laboratory versus labor ward. STUDY DESIGN 300 patients were included prospectively. In phase I, swabs were analyzed by selective culture and rapid PCR in the laboratory. In phase II, swabs were analyzed accordingly, but the PCR test was conducted in labor ward. Test performances were analyzed and compared. RESULTS In phase I the rapid PCR test had a sensitivity of 85.71% and a specificity of 95.9%. The GBS colonization rate was 18.67%. Overall 8.5% of the PCR results were invalid. In phase II the PCR test showed a sensitivity of 85.71% and a specificity of 95.65%. The GBS colonization rate was 23.3%. Overall 23.5% of swabs tested with PCR were invalid. Initiation of specific, short 2-hour training for operating personnel in the labor ward reduced the invalid test rate to 13.4%. CONCLUSION The rapid PCR-based test yields adequate results to identify GBS colonization when performed in labor ward. In order to reduce the number of invalid tests a short training period is needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dinoflagellates of Alexandrium genus are known to be producers of paralytic shellfish toxins that regularly impact the shellfish aquaculture industry and fisheries. Accurate detection of Alexandrium including A. minutum is crucial for environmental monitoring and sanitary issues. In this study, we firstly developed a quantitative lateral flow immunoassay (LFIA) using super-paramagnetic nanobeads for A. minutum whole cells. This dipstick assay relies on two distinct monoclonal antibodies used in a sandwich format and directed against surface antigens of this organism. No sample preparation is required. Either frozen or live cells can be detected and quantified. The specificity and sensitivity are assessed by using phytoplankton culture and field samples spiked with a known amount of cultured A. minutum cells. This LFIA is shown to be highly specific for A. minutum and able to detect reproducibly 105 cells/L within 30 min. The test is applied to environmental samples already characterized by light microscopy counting. No significant difference is observed between the cell densities obtained by these two methods. This handy super-paramagnetic lateral flow immnunoassay biosensor can greatly assist water quality monitoring programs as well as ecological research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The chromogenic βLacta test developed for the rapid detection of β-lactamase-hydrolyzing extended-spectrum cephalosporins in Enterobacteriaceae revealed good performance with extended-spectrum β-lactamase (ESBL) producers (97.5% true-positive results). However, false-negative results occurred with chromosomal AmpC hyperproducers and plasmid AmpC producers, whereas uninterpretable results were mostly due to VIM-1 carbapenemase producers and possibly low levels of expressed ESBLs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bovine coronavirus (BCoV) is a member of the group 2 of the Coronavirus (Nidovirales: Coronaviridae) and the causative agent of enteritis in both calves and adult bovine, as well as respiratory disease in calves. The present study aimed to develop a semi-nested RT-PCR for the detection of BCoV based on representative up-to-date sequences of the nucleocapsid gene, a conserved region of coronavirus genome. Three primers were designed, the first round with a 463bp and the second (semi-nested) with a 306bp predicted fragment. The analytical sensitivity was determined by 10-fold serial dilutions of the BCoV Kakegawa strain (HA titre: 256) in DEPC treated ultra-pure water, in fetal bovine serum (FBS) and in a BCoV-free fecal suspension, when positive results were found up to the 10-2, 10-3 and 10-7 dilutions, respectively, which suggests that the total amount of RNA in the sample influence the precipitation of pellets by the method of extraction used. When fecal samples was used, a large quantity of total RNA serves as carrier of BCoV RNA, demonstrating a high analytical sensitivity and lack of possible substances inhibiting the PCR. The final semi-nested RT-PCR protocol was applied to 25 fecal samples from adult cows, previously tested by a nested RT-PCR RdRp used as a reference test, resulting in 20 and 17 positives for the first and second tests, respectively, and a substantial agreement was found by kappa statistics (0.694). The high sensitivity and specificity of the new proposed method and the fact that primers were designed based on current BCoV sequences give basis to a more accurate diagnosis of BCoV-caused diseases, as well as to further insights on protocols for the detection of other Coronavirus representatives of both Animal and Public Health importance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The MRSA-Screen test (Denka Seiken Co., Ltd., Tokyo, Japan), consisting of a slide latex agglutination kit that detects PBP 2a with a monoclonal antibody, was blindly compared to the oxacillin disk diffusion test, the oxacillin-salt agar screen, and PCR of the mecA gene for the detection of methicillin resistance in Staphylococcus aureus. A total of 120 methicillin-susceptible S. aureus (MSSA) and 80 methicillin-resistant S. aureus (MRSA) isolates, defined by the absence or presence of the mecA gene, respectively, were tested. The MRSA-Screen test, the oxacillin disk diffusion test, and the oxacillin-salt agar screening test showed sensitivities of 100, 61.3, and 82.5% and specificities of 99.2, 96.7, and 98.3%, respectively. We conclude that the MRSA-Screen is a very accurate, reliable, and fast test (15 min) for differentiation of MRSA from MSSA colonies on agar plates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The susceptibility of 49 Mycobacterium tuberculosis clinical isolates to isoniazid (INH) and rifampisin (RIF) (28 multi-drug resistant-tuberculosis samples) was determined by a nitrate reductase assay (NRA) on blood agar. Agreement between the NRA and other testing methods was found to be 93.8% for both INH and RIF. The sensitivity, specificity, positive predictive value and negative predictive value for INH were 92.8%, 94.2%, 86.6% and 97%, respectively. The sensitivity, specificity, positive predictive value and negative predictive value for RIF were 90.4%, 96.4%, 95% and 93.1%. In conclusion, we show here that blood agar can be used effectively for the NRA test.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Early detection of drug resistance in Mycobacterium tuberculosis isolates allows for earlier and more effective treatment of patients. The aim of this study was to investigate the performance of the malachite green decolourisation assay (MGDA) in detecting isoniazid (INH) and rifampicin (RIF) resistance in M. tuberculosis clinical isolates. Fifty M. tuberculosis isolates, including 19 multidrug-resistant, eight INH-resistant and 23 INH and RIF-susceptible samples, were tested. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and agreement of the assay for INH were 92.5%, 91.3%, 92.5%, 91.3% and 92%, respectively. Similarly, the sensitivity, specificity, PPV, NPV and agreement of the assay for RIF were 94.7%, 100%, 100%, 96.8% and 98%, respectively. There was a major discrepancy in the tests of two isolates, as they were sensitive to INH by the MGDA test, but resistant by the reference method. There was a minor discrepancy in the tests of two additional isolates, as they were sensitive to INH by the reference method, but resistant by the MGDA test. The drug susceptibility test results were obtained within eight-nine days. In conclusion, the MGDA test is a reliable and accurate method for the rapid detection of INH and RIF resistance compared with the reference method and the MGDA test additionally requires less time to obtain results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To compare the results of rapid PCR screening for MRSA using the GeneXpert system with those of cultures in an outbreak setting. Methods: GeneXpert was used for screening MRSA in nose, throat, groin, and other clinical samples during a 6-month period. Samples were performed using a double-swab transystem. When >1 sample was found positive in a screening set, all second swabs of the set were analysed by culture. Results: From June to October 2009, 7568 rapid tests were performed, among which 432 (5.7%) were positive (nose: 149/2090, 7.1%; throat: 98/2078, 4.7%; groin: 152/2080, 7.3%; urine: 14/1090, 1.3%; wounds: 18/150, 12%; and others:1/27, 3.7%), and 84 (1.1%) were invalid. A total of 1517 samples were analyzed by both rapid PCR and culture. Rapid tests had a sensitivity of 0.896 compared to cultures, a specificity of 0.769, a PPV of 0.763, and a NPV of 0.899. The rapid test was found to be less sensitive in throat samples (0.81) than in nose or inguinal samples (0.93 for both). In 32/192 (16%) patients a positive rapid PCR result was not confirmed by culture, despite several subsequent screening samples in some patients. Cycle threshold (Ct) for SCCmec of these PCR positive reactions were all >30. Conclusions: GeneXpert MRSA was found to be suitable for the rapid detection in nose, inguinal, and throat samples, however with a lower sensitivity in the later. Negative cultures in 16% of our PCR-positive patients raised the question of false positivity or higher sensitivity of GeneXpert. Further work is needed to investigate these cases.