932 resultados para CT reconstruction


Relevância:

100.00% 100.00%

Publicador:

Resumo:

[ES]The purpose of this paper was to use threedimensional computed tomographic reconstruction as another tool to teach in the veterinary colleges. 2-millimeters thick transverse images of two foals and one dog were obtained. Images provided excellent detail of relevant anatomic structures and detailed information regarding the extent of disease and accurate discrimination of neoplastic versus non-neoplastic diseases. Tridimensional reconstruction can be a valuable diagnostic aid for clinical evaluation of several disturbances and could be used as a tool for teaching anatomy in veterinary schools.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Adolescent Idiopathic Scoliosis (AIS) has been associated with reduced pulmonary function believed to be due to a restriction of lung volume by the deformed thoracic cavity. A recent study by our group examined the changes in lung volume pre and post anterior thoracoscopic scoliosis correction using pulmonary function testing (1), however the anatomical changes in ribcage shape and left/right lung volume after thoracoscopic surgery which govern overall respiratory capacity are unknown. The aim of this study was to use 3D rendering from CT scan data to compare lung and ribcage anatomical changes from pre to two years post thoracoscopic anterior scoliosis correction. The study concluded that 3D volumetric reconstruction from CT scans is a powerful means of evaluating changes in pulmonary and thoracic anatomy following surgical AIS correction. Most likely, lung volume changes following thoracoscopic scoliosis correction are multifactorial and affected by changes in height (due to residual growth), ribcage shape, diaphragm positioning, Cobb angle correction in the thoracic spine. Further analysis of the 3D reconstructions will be performed to assess how each of these factors affect lung volume in this patient cohort.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: X-ray computed tomography (CT) is widely used, both clinically and preclinically, for fast, high-resolution anatomic imaging; however, compelling opportunities exist to expand its use in functional imaging applications. For instance, spectral information combined with nanoparticle contrast agents enables quantification of tissue perfusion levels, while temporal information details cardiac and respiratory dynamics. The authors propose and demonstrate a projection acquisition and reconstruction strategy for 5D CT (3D+dual energy+time) which recovers spectral and temporal information without substantially increasing radiation dose or sampling time relative to anatomic imaging protocols. METHODS: The authors approach the 5D reconstruction problem within the framework of low-rank and sparse matrix decomposition. Unlike previous work on rank-sparsity constrained CT reconstruction, the authors establish an explicit rank-sparse signal model to describe the spectral and temporal dimensions. The spectral dimension is represented as a well-sampled time and energy averaged image plus regularly undersampled principal components describing the spectral contrast. The temporal dimension is represented as the same time and energy averaged reconstruction plus contiguous, spatially sparse, and irregularly sampled temporal contrast images. Using a nonlinear, image domain filtration approach, the authors refer to as rank-sparse kernel regression, the authors transfer image structure from the well-sampled time and energy averaged reconstruction to the spectral and temporal contrast images. This regularization strategy strictly constrains the reconstruction problem while approximately separating the temporal and spectral dimensions. Separability results in a highly compressed representation for the 5D data in which projections are shared between the temporal and spectral reconstruction subproblems, enabling substantial undersampling. The authors solved the 5D reconstruction problem using the split Bregman method and GPU-based implementations of backprojection, reprojection, and kernel regression. Using a preclinical mouse model, the authors apply the proposed algorithm to study myocardial injury following radiation treatment of breast cancer. RESULTS: Quantitative 5D simulations are performed using the MOBY mouse phantom. Twenty data sets (ten cardiac phases, two energies) are reconstructed with 88 μm, isotropic voxels from 450 total projections acquired over a single 360° rotation. In vivo 5D myocardial injury data sets acquired in two mice injected with gold and iodine nanoparticles are also reconstructed with 20 data sets per mouse using the same acquisition parameters (dose: ∼60 mGy). For both the simulations and the in vivo data, the reconstruction quality is sufficient to perform material decomposition into gold and iodine maps to localize the extent of myocardial injury (gold accumulation) and to measure cardiac functional metrics (vascular iodine). Their 5D CT imaging protocol represents a 95% reduction in radiation dose per cardiac phase and energy and a 40-fold decrease in projection sampling time relative to their standard imaging protocol. CONCLUSIONS: Their 5D CT data acquisition and reconstruction protocol efficiently exploits the rank-sparse nature of spectral and temporal CT data to provide high-fidelity reconstruction results without increased radiation dose or sampling time.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Les artéfacts métalliques entraînent un épaississement artéfactuel de la paroi des tuteurs en tomodensitométrie (TDM) avec réduction apparente de leur lumière. Cette étude transversale prospective, devis mesures répétées et observateurs avec méthode en aveugle, chez 24 patients consécutifs/71 tuteurs coronariens a pour objectif de comparer l’épaisseur de paroi des tuteurs en TDM après reconstruction par un algorithme avec renforcement des bords et un algorithme standard. Une angiographie coronarienne par TDM 256 coupes a été réalisée, avec reconstruction par algorithmes avec renforcement des bords et standard. L’épaisseur de paroi des tuteurs était mesurée par méthodes orthogonale (diamètres) et circonférentielle (circonférences). La qualité d’image des tuteurs était évaluée par échelle ordinale, et les données analysées par modèles linéaire mixte et régression logistique des cotes proportionnelles. L’épaisseur de paroi des tuteurs était inférieure avec l’algorithme avec renforcement des bords comparé à l’algorithme standard, avec les méthodes orthogonale (0,97±0,02 vs 1,09±0,03 mm, respectivement; p<0,001) et circonférentielle (1,13±0,02 vs 1,21±0,02 mm, respectivement; p<0,001). Le premier causait moins de surestimation par rapport à l’épaisseur nominale comparé au second, avec méthodes orthogonale (0,89±0,19 vs 1,00±0,26 mm, respectivement; p<0,001) et circonférentielle (1,06±0,26 vs 1,13±0,31 mm, respectivement; p=0,005) et diminuait de 6 % la surestimation. Les scores de qualité étaient meilleurs avec l’algorithme avec renforcement des bords (OR 3,71; IC 95% 2,33–5,92; p<0,001). En conclusion, la reconstruction des images avec l’algorithme avec renforcement des bords génère des parois de tuteurs plus minces, moins de surestimation, et de meilleurs scores de qualité d’image que l’algorithme standard.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Les artéfacts métalliques entraînent un épaississement artéfactuel de la paroi des tuteurs en tomodensitométrie (TDM) avec réduction apparente de leur lumière. Cette étude transversale prospective, devis mesures répétées et observateurs avec méthode en aveugle, chez 24 patients consécutifs/71 tuteurs coronariens a pour objectif de comparer l’épaisseur de paroi des tuteurs en TDM après reconstruction par un algorithme avec renforcement des bords et un algorithme standard. Une angiographie coronarienne par TDM 256 coupes a été réalisée, avec reconstruction par algorithmes avec renforcement des bords et standard. L’épaisseur de paroi des tuteurs était mesurée par méthodes orthogonale (diamètres) et circonférentielle (circonférences). La qualité d’image des tuteurs était évaluée par échelle ordinale, et les données analysées par modèles linéaire mixte et régression logistique des cotes proportionnelles. L’épaisseur de paroi des tuteurs était inférieure avec l’algorithme avec renforcement des bords comparé à l’algorithme standard, avec les méthodes orthogonale (0,97±0,02 vs 1,09±0,03 mm, respectivement; p<0,001) et circonférentielle (1,13±0,02 vs 1,21±0,02 mm, respectivement; p<0,001). Le premier causait moins de surestimation par rapport à l’épaisseur nominale comparé au second, avec méthodes orthogonale (0,89±0,19 vs 1,00±0,26 mm, respectivement; p<0,001) et circonférentielle (1,06±0,26 vs 1,13±0,31 mm, respectivement; p=0,005) et diminuait de 6 % la surestimation. Les scores de qualité étaient meilleurs avec l’algorithme avec renforcement des bords (OR 3,71; IC 95% 2,33–5,92; p<0,001). En conclusion, la reconstruction des images avec l’algorithme avec renforcement des bords génère des parois de tuteurs plus minces, moins de surestimation, et de meilleurs scores de qualité d’image que l’algorithme standard.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: We present an iterative framework for CT reconstruction from transmission ultrasound data which accurately and efficiently models the strong refraction effects that occur in our target application: Imaging the female breast. Methods: Our refractive ray tracing framework has its foundation in the fast marching method (FNMM) and it allows an accurate as well as efficient modeling of curved rays. We also describe a novel regularization scheme that yields further significant reconstruction quality improvements. A final contribution is the development of a realistic anthropomorphic digital breast phantom based on the NIH Visible Female data set. Results: Our system is able to resolve very fine details even in the presence of significant noise, and it reconstructs both sound speed and attenuation data. Excellent correspondence with a traditional, but significantly more computationally expensive wave equation solver is achieved. Conclusions: Apart from the accurate modeling of curved rays, decisive factors have also been our regularization scheme and the high-quality interpolation filter we have used. An added benefit of our framework is that it accelerates well on GPUs where we have shown that clinical 3D reconstruction speeds on the order of minutes are possible.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to assess the potential of monoenergetic computed tomography (CT) images to reduce beam hardening artifacts in comparison to standard CT images of dental restoration on dental post-mortem CT (PMCT). Thirty human decedents (15 male, 58 ± 22 years) with dental restorations were examined using standard single-energy CT (SECT) and dual-energy CT (DECT). DECT data were used to generate monoenergetic CT images, reflecting the X-ray attenuation at energy levels of 64, 69, 88 keV, and at an individually adjusted optimal energy level called OPTkeV. Artifact reduction and image quality of SECT and monoenergetic CT were assessed objectively and subjectively by two blinded readers. Subjectively, beam artifacts decreased visibly in 28/30 cases after monoenergetic CT reconstruction. Inter- and intra-reader agreement was good (k = 0.72, and k = 0.73 respectively). Beam hardening artifacts decreased significantly with increasing monoenergies (repeated-measures ANOVA p < 0.001). Artifact reduction was greatest on monoenergetic CT images at OPTkeV. Mean OPTkeV was 108 ± 17 keV. OPTkeV yielded the lowest difference between CT numbers of streak artifacts and reference tissues (-163 HU). Monoenergetic CT reconstructions significantly reduce beam hardening artifacts from dental restorations and improve image quality of post-mortem dental CT.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There is evidence in the literature for both a congenital and a post-traumatic aetiology for os odontoideum. In no series published to date has CT been used to aid in the diagnosis. This is a prospective study of the history of trauma and presence of diagnostic features on CT of 18 consecutive cases with os odontoideum. Our objective was to derive clinically useful radiological features enabling accurate differentiation between congenital and post-traumatic aetiologies. A mid-sagittal CT reconstruction of the atlanto-dens joint was obtained. Hypertrophy of the anterior arch of the atlas was quantified by measurement of the arch-peg-area ratio. The presence of dysplastic features (a positive jigsaw sign) of the atlanto-axial joint were noted. These included narrowing of the cartilage space and interdigitation of the two joint surfaces. A history of a potential traumatic aetiology was only obtained in one of the 18 (6%) in our series. A significant elevation of the arch-peg ratio was found when comparing this series to 85 controls. And a positive jigsaw sign was observed in 75% of cases. These features were not seen in paediatric cases of atlanto-axial instability, including odontoid non-union. In conclusion, an elevated arch-peg ratio and the presence of a jigsaw sign are sensitive and specific diagnostic criteria for os odontoideum. This series supports a congenital aetiology for this condition.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Spectral CT using a photon counting x-ray detector (PCXD) shows great potential for measuring material composition based on energy dependent x-ray attenuation. Spectral CT is especially suited for imaging with K-edge contrast agents to address the otherwise limited contrast in soft tissues. We have developed a micro-CT system based on a PCXD. This system enables full spectrum CT in which the energy thresholds of the PCXD are swept to sample the full energy spectrum for each detector element and projection angle. Measurements provided by the PCXD, however, are distorted due to undesirable physical eects in the detector and are very noisy due to photon starvation. In this work, we proposed two methods based on machine learning to address the spectral distortion issue and to improve the material decomposition. This rst approach is to model distortions using an articial neural network (ANN) and compensate for the distortion in a statistical reconstruction. The second approach is to directly correct for the distortion in the projections. Both technique can be done as a calibration process where the neural network can be trained using 3D printed phantoms data to learn the distortion model or the correction model of the spectral distortion. This replaces the need for synchrotron measurements required in conventional technique to derive the distortion model parametrically which could be costly and time consuming. The results demonstrate experimental feasibility and potential advantages of ANN-based distortion modeling and correction for more accurate K-edge imaging with a PCXD. Given the computational eciency with which the ANN can be applied to projection data, the proposed scheme can be readily integrated into existing CT reconstruction pipelines.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Lateral or transaxial truncation of cone-beam data can occur either due to the field of view limitation of the scanning apparatus or iregion-of-interest tomography. In this paper, we Suggest two new methods to handle lateral truncation in helical scan CT. It is seen that reconstruction with laterally truncated projection data, assuming it to be complete, gives severe artifacts which even penetrates into the field of view. A row-by-row data completion approach using linear prediction is introduced for helical scan truncated data. An extension of this technique known as windowed linear prediction approach is introduced. Efficacy of the two techniques are shown using simulation with standard phantoms. A quantitative image quality measure of the resulting reconstructed images are used to evaluate the performance of the proposed methods against an extension of a standard existing technique.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2015

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To assess the diagnostic accuracy, image quality, and radiation dose of an iterative reconstruction algorithm compared with a filtered back projection (FBP) algorithm for abdominal computed tomography (CT) at different tube voltages.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To investigate whether an adaptive statistical iterative reconstruction (ASIR) algorithm improves the image quality at low-tube-voltage (80-kVp), high-tube-current (675-mA) multidetector abdominal computed tomography (CT) during the late hepatic arterial phase.