935 resultados para COLORED GLASS
Resumo:
We present the first measurements of the rho(770)(0),K(*)(892),Delta(1232)(++),Sigma(1385), and Lambda(1520) resonances in d+Au collisions at
Resumo:
Dissertação para obtenção do Grau de Mestre em Arte e Ciência do Vidro
Resumo:
El calidoscopi és una joguina que converteix fragments de vidre acolorit en patrons infinitament variats mitjançant l'ús de miralls. Hi ha quelcom satisfactori en els patrons –els necessitem per crear significat, i trobem bellesa en la seva simetria. No obstant, els sistemes complexos desobeeixen les fórmules simples. Per exemple, és impossible descriure una cosa tan prosaica com el comportament del fum mentre ascendeix fent servir les matemàtiques clàssiques. Agafant en préstec idees de diferents disciplines, podem considerar l'alfabetització informacional com una invitació per als nostres estudiants per jugar amb la imprevisible varietat de l'experiència humana i descobrir patrons que els resultin plens de significat.
Resumo:
The dataset is composed of 57 samples from 15 stations. The phytoplankton samples were collected by 5l Niskin bottles attached to the CTD system. The sampling depths were selected according to the CTD profiles and the in situ fluorometer readings. The samples (50 ml sea water) were preserved with prefiltered (0.2 micron) glutardialdehyde solution (1.5 ml of commercial glutardialdehyde (25%)) into dark colored glass bottles. Preserved samples were poured into 10 or 25 ml settling chambers (Hydro-Bios) for cells to settle on the bottom over a day. Species identification and enumeration were done under an inverted microscope (Olympus IX71). At least 400 specimen were tried to be counted in each sample.
Resumo:
The dataset is composed of 34 samples from 23 stations. The phytoplankton samples were collected by 5l Niskin bottles attached to the CTD system. The sampling depths were selected according to the CTD profiles and the in situ fluorometer readings. The samples (50 ml sea water) were preserved with prefiltered (0.2 micron) glutardialdehyde solution (1.5 ml of commercial glutardialdehyde (25%)) into dark colored glass bottles. Preserved samples were poured into 10 or 25 ml settling chambers (Hydro-Bios) for cells to settle on the bottom over a day. Species identification and enumeration were done under an inverted microscope (Olympus IX71). At least 400 specimen were tried to be counted in each sample.
Resumo:
The dataset is composed of 22 samples from 14 stations. The phytoplankton samples were collected by 5l Niskin bottles attached to the CTD system. The sampling depths were selected according to the CTD profiles and the in situ fluorometer readings. The samples (50 ml sea water) were preserved with prefiltered (0.2 micron) glutardialdehyde solution (1.5 ml of commercial glutardialdehyde (25%)) into dark colored glass bottles. Preserved samples were poured into 10 or 25 ml settling chambers (Hydro-Bios) for cells to settle on the bottom over a day. Species identification and enumeration were done under an inverted microscope (Olympus IX71). At least 400 specimen were tried to be counted in each sample.
Resumo:
The dataset is composed of 46 samples from 9 stations. The phytoplankton samples were collected by 5l Niskin bottles attached to the CTD system. The sampling depths were selected according to the CTD profiles and the in situ fluorometer readings. The samples (50 ml sea water) were preserved with prefiltered (0.2 micron) glutardialdehyde solution (1.5 ml of commercial glutardialdehyde (25%)) into dark colored glass bottles. Preserved samples were poured into 10 or 25 ml settling chambers (Hydro-Bios) for cells to settle on the bottom over a day. Species identification and enumeration were done under an inverted microscope (Olympus IX71). At least 400 specimen were tried to be counted in each sample.
Resumo:
The dataset is composed of 48 samples from 17 stations. The phytoplankton samples were collected by 5l Niskin bottles attached to the CTD system. The sampling depths were selected according to the CTD profiles and the in situ fluorometer readings. The samples (50 ml sea water) were preserved with prefiltered (0.2 micron) glutardialdehyde solution (1.5 ml of commercial glutardialdehyde (25%)) into dark colored glass bottles. Preserved samples were poured into 10 or 25 ml settling chambers (Hydro-Bios) for cells to settle on the bottom over a day. Species identification and enumeration were done under an inverted microscope (Olympus IX71). At least 400 specimen were tried to be counted in each sample.
Resumo:
The dataset is composed of 20 samples from 14 stations. The phytoplankton samples were collected by 5l Niskin bottles attached to the CTD system. The sampling depths were selected according to the CTD profiles and the in situ fluorometer readings. The samples (50 ml sea water) were preserved with prefiltered (0.2 micron) glutardialdehyde solution (1.5 ml of commercial glutardialdehyde (25%)) into dark colored glass bottles. Preserved samples were poured into 10 or 25 ml settling chambers (Hydro-Bios) for cells to settle on the bottom over a day. Species identification and enumeration were done under an inverted microscope (Olympus IX71). At least 400 specimen were tried to be counted in each sample.
Resumo:
The problem addressed here originates in the industry of flat glass cutting and wood panel sawing, where smaller items are cut from larger items accordingly to predefined cutting patterns. In this type of industry the smaller pieces that are cut from the patterns are piled around the machine in stacks according to the size of the pieces, which are moved to the warehouse only when all items of the same size have been cut. If the cutting machine can process only one pattern at a time, and the workspace is limited, it is desirable to set the sequence in which the cutting patterns are processed in a way to minimize the maximum number of open stacks around the machine. This problem is known in literature as the minimization of open stacks (MOSP). To find the best sequence of the cutting patterns, we propose an integer programming model, based on interval graphs, that searches for an appropriate edge completion of the given graph of the problem, while defining a suitable coloring of its vertices.
Resumo:
PURPOSE: To meta-analyze the literature on the clinical performance of Class V restorations to assess the factors that influence retention, marginal integrity, and marginal discoloration of cervical lesions restored with composite resins, glass-ionomer-cement-based materials [glass-ionomer cement (GIC) and resin-modified glass ionomers (RMGICs)], and polyacid-modified resin composites (PMRC). MATERIALS AND METHODS: The English literature was searched (MEDLINE and SCOPUS) for prospective clinical trials on cervical restorations with an observation period of at least 18 months. The studies had to report about retention, marginal discoloration, marginal integrity, and marginal caries and include a description of the operative technique (beveling of enamel, roughening of dentin, type of isolation). Eighty-one studies involving 185 experiments for 47 adhesives matched the inclusion criteria. The statistical analysis was carried out by using the following linear mixed model: log (-log (Y /100)) = β + α log(T ) + error with β = log(λ), where β is a summary measure of the non-linear deterioration occurring in each experiment, including a random study effect. RESULTS: On average, 12.3% of the cervical restorations were lost, 27.9% exhibited marginal discoloration, and 34.6% exhibited deterioration of marginal integrity after 5 years. The calculation of the clinical index was 17.4% of failures after 5 years and 32.3% after 8 years. A higher variability was found for retention loss and marginal discoloration. Hardly any secondary caries lesions were detected, even in the experiments with a follow-up time longer than 8 years. Restorations placed using rubber-dam in teeth whose dentin was roughened showed a statistically significantly higher retention rate than those placed in teeth with unprepared dentin or without rubber-dam (p < 0.05). However, enamel beveling had no influence on any of the examined variables. Significant differences were found between pairs of adhesive systems and also between pairs of classes of adhesive systems. One-step self-etching had a significantly worse clinically index than two-step self-etching and three-step etch-and-rinse (p = 0.026 and p = 0.002, respectively). CONCLUSION: The clinical performance is significantly influenced by the type of adhesive system and/or the adhesive class to which the system belongs. Whether the dentin/enamel is roughened or not and whether rubberdam isolation is used or not also significantly influenced the clinical performance. Composite resin restorations placed with two-step self-etching and three-step etch-and-rinse adhesive systems should be preferred over onestep self-etching adhesive systems, GIC-based materials, and PMRCs.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
On fine scales, caustics produced with white light show vividly colored diffraction fringes. For caustics described by the elementary catastrophes of singularity theory, the colors are characteristic of the type of singularity. We study the diffraction colors of the fold and cusp catastrophes. The colors can be simulated computationally as the superposition of monochromatic patterns for different wavelengths. Far from the caustic, where the luminosity contrast is negligible, the fringe colors persist; an asymptotic theory explains why. Experiments with caustics produced by refraction through irregular bathroom-window glass show good agreement with theory. Colored fringes near the cusp reveal fine lines that are not present in any of the monochromatic components; these lines are explained in terms of partial decoherence between rays with widely differing path differences.
Resumo:
Several medical and dental schools have described their experience in the transition from conventional to digital microscopy in the teaching of general pathology and histology disciplines; however, this transitional process has scarcely been reported in the teaching of oral pathology. Therefore, the objective of the current study is to report the transition from conventional glass slide to virtual microscopy in oral pathology teaching, a unique experience in Latin America. An Aperio ScanScope® scanner was used to digitalize histological slides used in practical lectures of oral pathology. The challenges and benefits observed by the group of Professors from the Piracicaba Dental School (Brazil) are described and a questionnaire to evaluate the students' compliance to this new methodology was applied. An improvement in the classes was described by the Professors who mainly dealt with questions related to pathological changes instead of technical problems; also, a higher interaction with the students was described. The simplicity of the software used and the high quality of the virtual slides, requiring a smaller time to identify microscopic structures, were considered important for a better teaching process. Virtual microscopy used to teach oral pathology represents a useful educational methodology, with an excellent compliance of the dental students.
Resumo:
The purpose of this study was to evaluate the clinical performance of glass ionomer cement (GIC) restorations comparing two minimally invasive methods in permanent teeth after 12 months. Fifty pregnant women (second trimester of pregnancy), mean age 22 ± 5.30 years, were treated by two previously trained operators. The treatment approaches tested were: chemomechanical method (CarisolvTM; MediTeam) and atraumatic restorative treatment (ART). A split-mouth study design was used in which the two treatments were randomly placed in 50 matched pairs of permanent teeth. The chemomechanical method (CM) was the test group and the ART was the control group. The treatments were performed in Public Health Centers. The tested restorative material was a high-strength GIC (Ketac Molar; 3M/ESPE). The restorations were placed according to the ART guidelines. Two calibrated independent examiners evaluated the restorations in accordance with ART criteria. The inter-examiner kappa was 0.97. Data were analyzed using 95% confidence interval on the binomial distribution and Fisher's exact test at 5% significance level. In a 12-month follow-up, 86% of the restorations were evaluated. In the test group (CM), 100% (CI=93.3-100%) of the restorations were considered successful. In the control group (ART) 97.6% (CI=87.4-99.9%) of the restorations were considered successful and 2.4% unsuccessful (marginal defect >0.5 mm). There was no statistically significant difference between the 12-mounth success rate for both groups (Fisher's exact test: P=0.49) and between the two operators (Fisher's exact test: P=1.00). Both minimally invasive methods, chemomechanical method and ART, showed a similar clinical performance after 12 months of follow up.