982 resultados para COCHLEAR IMPLANT


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Spectral peak resolution was investigated in normal hearing (NH), hearing impaired (HI), and cochlear implant (CI) listeners. The task involved discriminating between two rippled noise stimuli in which the frequency positions of the log-spaced peaks and valleys were interchanged. The ripple spacing was varied adaptively from 0.13 to 11.31 ripples/octave, and the minimum ripple spacing at which a reversal in peak and trough positions could be detected was determined as the spectral peak resolution threshold for each listener. Spectral peak resolution was best, on average, in NH listeners, poorest in CI listeners, and intermediate for HI listeners. There was a significant relationship between spectral peak resolution and both vowel and consonant recognition in quiet across the three listener groups. The results indicate that the degree of spectral peak resolution required for accurate vowel and consonant recognition in quiet backgrounds is around 4 ripples/octave, and that spectral peak resolution poorer than around 1–2 ripples/octave may result in highly degraded speech recognition. These results suggest that efforts to improve spectral peak resolution for HI and CI users may lead to improved speech recognition

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to explore the potential advantages, both theoretical and applied, of preserving low-frequency acoustic hearing in cochlear implant patients. Several hypotheses are presented that predict that residual low-frequency acoustic hearing along with electric stimulation for high frequencies will provide an advantage over traditional long-electrode cochlear implants for the recognition of speech in competing backgrounds. A simulation experiment in normal-hearing subjects demonstrated a clear advantage for preserving low-frequency residual acoustic hearing for speech recognition in a background of other talkers, but not in steady noise. Three subjects with an implanted "short-electrode" cochlear implant and preserved low-frequency acoustic hearing were also tested on speech recognition in the same competing backgrounds and compared to a larger group of traditional cochlear implant users. Each of the three short-electrode subjects performed better than any of the traditional long-electrode implant subjects for speech recognition in a background of other talkers, but not in steady noise, in general agreement with the simulation studies. When compared to a subgroup of traditional implant users matched according to speech recognition ability in quiet, the short-electrode patients showed a 9-dB advantage in the multitalker background. These experiments provide strong preliminary support for retaining residual low-frequency acoustic hearing in cochlear implant patients. The results are consistent with the idea that better perception of voice pitch, which can aid in separating voices in a background of other talkers, was responsible for this advantage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The differences in spectral shape resolution abilities among cochlear implant ~CI! listeners, and between CI and normal-hearing ~NH! listeners, when listening with the same number of channels ~12!, was investigated. In addition, the effect of the number of channels on spectral shape resolution was examined. The stimuli were rippled noise signals with various ripple frequency-spacings. An adaptive 4IFC procedure was used to determine the threshold for resolvable ripple spacing, which was the spacing at which an interchange in peak and valley positions could be discriminated. The results showed poorer spectral shape resolution in CI compared to NH listeners ~average thresholds of approximately 3000 and 400 Hz, respectively!, and wide variability among CI listeners ~range of approximately 800 to 8000 Hz!. There was a significant relationship between spectral shape resolution and vowel recognition. The spectral shape resolution thresholds of NH listeners increased as the number of channels increased from 1 to 16, while the CI listeners showed a performance plateau at 4–6 channels, which is consistent with previous results using speech recognition measures. These results indicate that this test may provide a measure of CI performance which is time efficient and non-linguistic, and therefore, if verified, may provide a useful contribution to the prediction of speech perception in adults and children who use CIs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to evaluate the neural response in double-array cochlear implant as well as to describe the refractory recovery and the spread of excitation functions. In a prospective study 11 patients were implanted with the double-array cochlear implant. Neural response telemetry (NRT) was performed intra-operatively. NRT threshold could be registered in 6 of the 11 patients, at least in one electrode. The remaining five patients did not show measurable neural response intra-operatively. It was noted that although recovery and spread of excitation functions could be recorded in all the tested electrodes with measurable neural responses, the responses were shown to be different from the usual register in patients with other etiologies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conclusion. The study shows that there are differences in the measurement of the action potentials with and without the stylet in the Nucleus Freedom Contour Advance that are higher in the apex than in the base of the cochlea. Objectives. To determine if there are differences in the intraoperative impedances and in the neural response telemetry threshold values in the Nucleus Freedom Contour Advance before and after stylet removal. Subjects and methods. This was a prospective clinical study. Intraoperative impedances and neural response telemetry in users of the Freedom Contour Advance Cochlear Implant were measured before and after stylet removal. Results. There was a significant reduction in the impedance values of an average 1.5 k Omega +/- 2.3 in common ground mode and 1.3 k Omega +/- 2.3 for all monopolar modes after the stylet removal (p < 0.001). When analyzing the apical, medium, and basal electrodes, there was a statistically significant reduction in the neural response thresholds after stylet removal only in the apical electrodes (p = 0.001).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cochlear implant is the method of choice in the treatment of deep sensorineural hypoacusis, particularly in patients where conventional amplification devices do not imply noticeable clinical improvement. Imaging findings are crucial in the indication or contraindication for such surgical procedure. In the assessment of the temporal bone, radiologists should be familiar with relative or absolute contraindication factors, as well as with factors that might significantly complicate the implantation. Some criteria such as cochlear nerve aplasia, labyrinthine and/or cochlear aplasia are still considered as absolute contraindications, in spite of studies bringing such criteria into question. Cochlear dysplasias constitute relative contraindications, among them labyrinthitis ossificans is highlighted. Other alterations may be mentioned as complicating agents in the temporal bone assessment, namely, hypoplasia of the mastoid process, aberrant facial nerve, otomastoiditis, otosclerosis, dehiscent jugular bulb, enlarged endolymphatic duct and sac. The experienced radiologist assumes an important role in the evaluation of this condition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper provides an in-depth examination of the experiences of one cochlear implant recipient who participated in a psychosocial group rehabilitation program that was aimed at overcoming the communication and psychosocial handicaps that may accompany hearing loss.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study investigates how children with cochlear implants from simultaneous communications backgrounds and from oral education backgrounds experience communication breakdowns. The study examines each group's response to communication breakdowns and the repair strategies of each group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Access to thesis is restricted. Contact Archives and Rare Books. This paper presents a case study involving a prelingually hearing impaired child with a Nucleus 22 cochlear implant and changes in the child’s ability to use spoken language when the implant was not functioning properly. This study investigates the usefulness of acoustic analyses of vowel productions to document changes in speech production during times when the implant was not working.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Most cochlear implant (CI) users perceive music poorly. Little is known, however, about the musical enjoyment received by CI users. The author examined possible relationships between musical enjoyment and music perception tasks through the use of 1) multiple musical tests, and 2) two groups of listeners: normal-hearing (NH) listeners with a CI-simulation and actual CI users. The two groups’ performances are compared to determine whether NH participants listening to music via CI-simulation software are a good model for actual CI users for perceiving music.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates the conversational fluency of young cochlear implant users. The study compares objective measures and subjective impressions of conversation fluency, relates how children’s communication skills influence both objective and subjective measures of conversational fluency, and compares the performance of children who use an oral mode with those who use a total communication mode in everyday conversation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The primary objective of this study was to document the benefits and possible detriments of combining ipsilateral acoustic hearing in the cochlear implant ear of a patient with preserved low frequency residual hearing post cochlear implantation. The secondary aim was to examine the efficacy of various cochlear implant mapping and hearing aid fitting strategies in relation to electro-acoustic benefits.