970 resultados para CLINICAL MEASUREMENT


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reaching a consensus in terms of interchangeability and utility (i.e., disease detection/monitoring) of a medical device is the eventual aim of repeatability and agreement studies. The aim of the tolerance and relative utility indices described in this report is to provide a methodology to compare change in clinical measurement noise between different populations (repeatability) or measurement methods (agreement), so as to highlight problematic areas. No longitudinal data are required to calculate these indices. Both indices establish a metric of least to most effected across all parameters to facilitate comparison. If validated, these indices may prove useful tools when combining reports and forming the consensus required in the validation process for software updates and new medical devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STUDY DESIGN: Concurrent validity between postural indices obtained from digital photographs (two-dimensional [2D]), surface topography imaging (three-dimensional [3D]), and radiographs. OBJECTIVE: To assess the validity of a quantitative clinical postural assessment tool of the trunk based on photographs (2D) as compared to a surface topography system (3D) as well as indices calculated from radiographs. SUMMARY OF BACKGROUND DATA: To monitor progression of scoliosis or change in posture over time in young persons with idiopathic scoliosis (IS), noninvasive and nonionizing methods are recommended. In a clinical setting, posture can be quite easily assessed by calculating key postural indices from photographs. METHODS: Quantitative postural indices of 70 subjects aged 10 to 20 years old with IS (Cobb angle, 15 degrees -60 degrees) were measured from photographs and from 3D trunk surface images taken in the standing position. Shoulder, scapula, trunk list, pelvis, scoliosis, and waist angles indices were calculated with specially designed software. Frontal and sagittal Cobb angles and trunk list were also calculated on radiographs. The Pearson correlation coefficients (r) was used to estimate concurrent validity of the 2D clinical postural tool of the trunk with indices extracted from the 3D system and with those obtained from radiographs. RESULTS: The correlation between 2D and 3D indices was good to excellent for shoulder, pelvis, trunk list, and thoracic scoliosis (0.81>r<0.97; P<0.01) but fair to moderate for thoracic kyphosis, lumbar lordosis, and thoracolumbar or lumbar scoliosis (0.30>r<0.56; P<0.05). The correlation between 2D and radiograph spinal indices was fair to good (-0.33 to -0.80 with Cobb angles and 0.76 for trunk list; P<0.05). CONCLUSION: This tool will facilitate clinical practice by monitoring trunk posture among persons with IS. Further, it may contribute to a reduction in the use of radiographs to monitor scoliosis progression.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR CONSULTATION

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: Two noninvasive methods to measure dental implant stability are damping capacity assessment (Periotest) and resonance frequency analysis (Osstell). The objective of the present study was to assess the correlation of these 2 techniques in clinical use. MATERIALS AND METHODS: Implant stability of 213 clinically stable loaded and unloaded 1-stage implants in 65 patients was measured in triplicate by means of resonance frequency analysis and Periotest. Descriptive statistics as well as Pearson's, Spearman's, and intraclass correlation coefficients were calculated with SPSS 11.0.2. RESULTS: The mean values were 57.66 +/- 8.19 implant stability quotient for the resonance frequency analysis and -5.08 +/- 2.02 for the Periotest. The correlation of both measuring techniques was -0.64 (Pearson) and -0.65 (Spearman). The single-measure intraclass correlation coefficients for the ISQ and Periotest values were 0.99 and 0.88, respectively (95% CI). No significant correlation of implant length with either resonance frequency analysis or Periotest could be found. However, a significant correlation of implant diameter with both techniques was found (P < .005). The correlation of both measuring systems is moderate to good. It seems that the Periotest is more susceptible to clinical measurement variables than the Osstell device. The intraclass correlation indicated lower measurement precision for the Periotest technique. Additionally, the Periotest values differed more from the normal (Gaussian) curve of distribution than the ISQs. Both measurement techniques show a significant correlation to the implant diameter. CONCLUSION: Resonance frequency analysis appeared to be the more precise technique.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Procedures for quantitative walking analysis include the assessment of body segment movements within defined gait cycles. Recently, methods to track human body motion using inertial measurement units have been suggested. It is not known if these techniques can be readily transferred to clinical measurement situations. This work investigates the aspects necessary for one inertial measurement unit mounted on the lower back to track orientation, and determine spatio-temporal features of gait outside the confines of a conventional gait laboratory. Apparent limitations of different inertial sensors can be overcome by fusing data using methods such as a Kalman filter. The benefits of optimizing such a filter for the type of motion are unknown. 3D accelerations and 3D angular velocities were collected for 18 healthy subjects while treadmill walking. Optimization of Kalman filter parameters improved pitch and roll angle estimates when compared to angles derived using stereophotogrammetry. A Weighted Fourier Linear Combiner method for estimating 3D orientation angles by constructing an analytical representation of angular velocities and allowing drift free integration is also presented. When tested this method provided accurate estimates of 3D orientation when compared to stereophotogrammetry. Methods to determine spatio-temporal features from lower trunk accelerations generally require knowledge of sensor alignment. A method was developed to estimate the instants of initial and final ground contact from accelerations measured by a waist mounted inertial device without rigorous alignment. A continuous wavelet transform method was used to filter and differentiate the signal and derive estimates of initial and final contact times. The technique was tested with data recorded for both healthy and pathologic (hemiplegia and Parkinson’s disease) subjects and validated using an instrumented mat. The results show that a single inertial measurement unit can assist whole body gait assessment however further investigation is required to understand altered gait timing in some pathological subjects.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The two elcctrophysiological tests currently favoured in the clinical measurement of hearing threshold arc the brainstorm evoked potential (BAEP) and the slow vertex response (SVR). However, both tests possess disadvantages. The BAEP is the test of choice in younger patients as it is stable at all levels of arousal, but little information has been obtained to date at a range of frequencies. The SVR is frequency specific but is unreliable in certain adult subjects and is unstable during sleep or in young children. These deficiencies have prompted research into a third group of potentials, the middle latency response (MLR) and the 40HZ responses. This research has compared the SVR and 40HZ response in waking adults and reports that the 40HZ test can provide a viable alternative to the SVR provided that a high degree of subject relaxation is ensured. A second study examined the morphology of the MLR and 40HZ during sleep. This work suggested that these potentials arc markedly different during sleep and that methodological factors have been responsible for masking these changes in previous studies. The clinical possibilities of tone pip BAEPs were then examined as these components were proved to be the only stable responses present in sleep. It was found that threshold estimates to 5OOHz, lOOOHz and 4000Hz stimuli could be made to within 15dBSL in most cases. A final study looked more closely at methods of obtaining frequency specific information in sleeping subjects. Threshold estimates were made using established BAEP parameters and this was compared to a 40HZ procedure which recorded a series of BAEPs over a 100msec. time sweep. Results indicated that the 40mHz procedure was superior to existing techniques in estimating threshold to low frequency stimuli. This research has confirmed a role for the MLR and 40Hz response as alternative measures of hearing capability in waking subjects and proposes that the 40Hz technique is useful in measuring frequency specific thresholds although the responses recorded derive primarily from the brainstem.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A sizeable amount of the testing in eye care, requires either the identification of targets such as letters to assess functional vision, or the subjective evaluation of imagery by an examiner. Computers can render a variety of different targets on their monitors and can be used to store and analyse ophthalmic images. However, existing computing hardware tends to be large, screen resolutions are often too low, and objective assessments of ophthalmic images unreliable. Recent advances in mobile computing hardware and computer-vision systems can be used to enhance clinical testing in optometry. High resolution touch screens embedded in mobile devices, can render targets at a wide variety of distances and can be used to record and respond to patient responses, automating testing methods. This has opened up new opportunities in computerised near vision testing. Equally, new image processing techniques can be used to increase the validity and reliability of objective computer vision systems. Three novel apps for assessing reading speed, contrast sensitivity and amplitude of accommodation were created by the author to demonstrate the potential of mobile computing to enhance clinical measurement. The reading speed app could present sentences effectively, control illumination and automate the testing procedure for reading speed assessment. Meanwhile the contrast sensitivity app made use of a bit stealing technique and swept frequency target, to rapidly assess a patient’s full contrast sensitivity function at both near and far distances. Finally, customised electronic hardware was created and interfaced to an app on a smartphone device to allow free space amplitude of accommodation measurement. A new geometrical model of the tear film and a ray tracing simulation of a Placido disc topographer were produced to provide insights on the effect of tear film breakdown on ophthalmic images. Furthermore, a new computer vision system, that used a novel eye-lash segmentation technique, was created to demonstrate the potential of computer vision systems for the clinical assessment of tear stability. Studies undertaken by the author to assess the validity and repeatability of the novel apps, found that their repeatability was comparable to, or better, than existing clinical methods for reading speed and contrast sensitivity assessment. Furthermore, the apps offered reduced examination times in comparison to their paper based equivalents. The reading speed and amplitude of accommodation apps correlated highly with existing methods of assessment supporting their validity. Their still remains questions over the validity of using a swept frequency sine-wave target to assess patient’s contrast sensitivity functions as no clinical test provides the range of spatial frequencies and contrasts, nor equivalent assessment at distance and near. A validation study of the new computer vision system found that the authors tear metric correlated better with existing subjective measures of tear film stability than those of a competing computer-vision system. However, repeatability was poor in comparison to the subjective measures due to eye lash interference. The new mobile apps, computer vision system, and studies outlined in this thesis provide further insight into the potential of applying mobile and image processing technology to enhance clinical testing by eye care professionals.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Plasma clearance of (51)Cr-EDTA ((51)Cr-EDTA-Cl) is an alternative method to evaluate glomerular filtration rate (GFR). This study aimed to investigate the concordance between (51)Cr-EDTA-Cl and renal inulin clearance (In-Cl) in renal transplant recipients as well to determine the repeatability of (51)Cr-EDTA-Cl in kidney donors. Forty four kidney recipients and 22 kidney donors were enrolled. Simultaneous measurements of (51)Cr-EDTA-Cl and In-Cl were performed. A single dose of 3.7MBq of (51)Cr-EDTA was injected and the plasma disappearance curve was created by taking blood samples at 2, 4, 6 and 8 h after injection. Bland and Altman statistical approach was used to quantify the agreement between In-Cl and (51)Cr-EDTA-Cl and to determine the better concordance between all possibilities of measure for the (51)Cr-EDTA-Cl. The mean of In-Cl was 44.5 +/- 17.9 ml/min/1.73 m(2). There was a positive correlation between In-Cl and all possible measurements of (51)Cr-EDTA-Cl. (51)Cr-EDTA-Cl with two samples taken at 4 and 8 h or at 4 and 6 h presenting the narrow limits of agreement and a difference (bias) of 2.8 and 2.7 ml/min, respectively. Two plasma sampling for (51)Cr-EDTA-Cl was a reliable method to measure GFR compared with In-Cl and comprises a suitable method to be used in kidney transplanted patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There are data suggesting that women swallow liquids at a lower flow rate and ingest smaller volumes in each swallow than men. Our objective in this work was to compare swallowing in asymptomatic men and women by videofluoroscopy. We studied 18 men [age = 33-77 years, mean = 61 (10) years] and 12 women [age = 29-72 years, mean = 53 (15) years] who swallowed in duplicate 5 and 10 ml of liquid and paste barium boluses. None of the volunteers had dysphagia, neurologic diseases, or oral, pharyngeal, or esophageal diseases. The videofluoroscopic examination showed that for the 5-ml bolus, women had a longer oropharyngeal transit [liquid: men, 0.63 (0.21) s, women, 0.88 (0.39) s; paste: men, 0.64 (0.35) s, women, 0.94 (0.58) s], longer oral transit [liquid: men, 0.41 (0.21) s, women, 0.59 (0.35) s; paste: men, 0.39 (0.28) s, women, 0.59 (0.42) s], and longer pharyngeal clearance [liquid: men, 0.36 (0.11) s, women, 0.45 (0.16) s; paste: men, 0.42 (0.25) s, women, 0.56 (0.27) s] compared with men (p < 0.05). We conclude that there are differences in swallowing between men and women, with women having a longer oropharyngeal transit than men for a 5-ml bolus.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. Outcome assessment in clinical trials using the Western Ontario and McMaster University (WOMAC 3.0) Osteoarthritis Index is traditionally achieved through self-administration of the Index. However, in other areas of clinical measurement, telephone administration has been shown to be a reliable method of acquiring data that are both accurate and complete. To address this issue in knee osteoarthritis (OA), we conducted a comparative study of telephone administration by interviewer of WOMAC LK3.0 versus onsite self-completion at the hospital. Methods. Fifty consenting patients with knee OA were randomized to complete the WOMAC LK3.0 Index by telephone interview one day, followed by onsite completion the following day, or vice versa. Neither patients nor interviewers had access to any prior scores. Results. The mean age of the 50 patients was 66.3 years (range 44-82); 34 (68%) were female and 16 (32%) male. There was excellent agreement between the mean office and telephone scores, with mean differences for the WOMAC LK3.0 pain, stiffness, and function subscale scores and total score of 0.09, 0.12, 0.78, and 0.98, respectively. These differences were well within the respective protocol defined equivalence criteria of +/- 1.7, +/- 0.9, +/- 6.4, and +/- 9.1, and represented differences from office scores of 0.9, 2.6, 2.4, and 2.2%, respectively. Conclusion. The use of telephone interviews for the WOMAC LK3.0 Index is a valid method of obtaining OA outcome measurements. These observations have important implications for designing data acquisition strategies for future OA clinical trials and for longterm observational studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

STUDY DESIGN: Clinical measurement. PURPOSE: The test-retest reliability of maximal grip strength measurements (MGSM) is examined in subjects for 12 weeks post-stroke together with maximal grip strength recovery and the maximal-grip and upper-extremity strength measurements' relationship with capacity and performance test scores. METHODS: A Jamar dynamometer and the Motricity Index (MI) were used for strength measurements. The Chedoke Arm and Hand Activity Inventory and ABILHAND questionnaire for evaluating capacities and performances. RESULTS: MGSM were reliable (Intraclass Correlation Coefficients = 0.97-0.99, Minimal Detectable Differences = 2.73-4.68 kg). Among the 34 participants, 47% did not have a measurable grip strength one week post-stroke but 50% of these recovered some strength within the first eight weeks. The MGSM and MI scores were correlated with scores of tests of capacity and performance (Spearman's Rank Correlation Coefficients = 0.69-0.94). CONCLUSIONS: MGSM are reliable in the first weeks after a stroke. LEVEL OF EVIDENCE: N/A.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectifs : Ce mémoire propose de répertorier par une revue systématique les instruments de mesure clinique des conduites addictives établies et émergentes; de les comparer au moyen d’une grille d’analyse afin de de déterminer si ces conduites sont cohésives au plan conceptuel. Méthode : La stratégie analytique employée s’est déroulée en trois étapes : 1) Via les moteurs de recherche Pubmed, Psychinfo, HAPI et Embase, nous avons cherché, pour l’ensemble des conduites addictives, les questionnaires ayant fait l’objet d’une étude de validation interne au plan psychométrique. 2) Une grille d’analyse a été développée et validée, couvrant 21 paramètres tirés de 4 catégories conceptuelles : les critères diagnostiques de dépendance (DSM-IVTR), le tempérament (Cloninger et Zuckerman), le processus de production du handicap social (Fougeyrollas) et une grille d’analyse cognitivo-comportementale (Beck). 3) tous les instruments ont été analysés et comparés au moyen de cette grille qui a été développée est validée par un accord inter-juge élevé. Résultats : Nous avons répertorié 191 questionnaires répartis sur 21 conduites addictives. On constate que les conduites les plus prévalentes sont également celles pour lesquelles on retrouve le plus grand nombre de questionnaires. Les catégories que les questionnaires évaluent le plus sont celles des critères de la dépendance et l’analyse cognitivo-comportementale, les catégories beaucoup moins bien représentées étant celles du tempérament et du processus de production du handicap social. On note des tendances semblables pour les paramètres entre les questionnaires portant sur la toxicomanie et ceux portant sur les addictions sans drogues. Conclusion : Ce mémoire confirme une cohésion clinique dans la mesure des addictions, tel que déterminé par une grille validée appliquée sur un ensemble exhaustif de questionnaires répertoriés par une revue systématique.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La mesure du déjettement du tronc est un élément important pour évaluer la posture en ce qui a trait à la scoliose idiopathique. Cependant, il y a peu d'informations quant à sa mesure et les associations entre le déjettement du tronc et d'autres indicateurs ou facteurs pertinents. Les objectifs de cette étude sont : 1) d’évaluer la validité et la fiabilité de test-retest du fil à plomb pour mesurer le déjettement du tronc de C7 à S1 chez les personnes atteintes de scoliose idiopathique; et 2) d'étudier l'association entre le déjettement du tronc et les facteurs suivants : la douleur, l’angle de Cobb, le type de scoliose, la santé mentale et l’image de soi chez les personnes atteintes de scoliose idiopathique. Nous avons recruté 55 sujets âgés de 10 à 21 ans atteints de scoliose idiopathique (angle de Cobb : 15º à 60º) de la clinique de scoliose dans un hôpital pédiatrique de soins tertiaires. Le déjettement a été mesuré directement sur les sujets à deux reprises par la même physiothérapeute de même que sur les radiographies prises ce jour-là. Deux mesures ont été prises à chaque fois : une les pieds joints (FT) et l’autre en écartant les pieds (FA). Les sujets ont répondu au questionnaire adressé au patient de la Scoliosis Research Society-22, qui traite de la douleur, de l'image de soi et de la santé mentale. Le type de scoliose et l'angle de Cobb ont été mesurés sur les radiographies prises ce jour-là. Nous avons utilisé la théorie de la généralisabilité pour calculer la fidélité de test-retest pour les mesures FT et FA, en rapportant les coefficients de fiabilité (f) et les erreurs types de mesure (SEM). La validité de la mesure du fil à plomb a été calculée en comparant les mesures prises directement sur les radiographies en utilisant le coefficient de corrélation de Pearson. Les corrélations de Pearson ont été calculées entre le déjettement du tronc et la douleur, l'angle de Cobb, l'image de soi et la santé mentale. Les corrélations de Spearman ont été calculées entre le déjettement du tronc et le type de scoliose. Nous avons ensuite utilisé des modèles de régression linéaire multiple pour déterminer les associations entre ces variables. Nos résultats indiquent que les mesures de déjettement du tronc en utilisant un fil à plomb ont une forte corrélation (r = 0,87) avec la mesure obtenue par radiographie. La mesure du déjettement du tronc en utilisant un fil à plomb a démontré une excellente fidélité de test-retest (f: 0,98 pour la mesure FT et 0,99 pour la mesure FA) et les SEM étaient de 2,0 mm pour la mesure FT et 1,8 mm pour la mesure FA. Le déjettement du tronc est corrélé positivement avec l'angle de Cobb (r = 0,32, p = 0,02), mais il n'est pas corrélé à la douleur, la santé mentale, l'image de soi ou le type de scoliose. Les conclusions de notre étude ont montré que la mesure clinique du déjettement du tronc en utilisant un fil à plomb est une méthode fiable et valide et que le déjettement du tronc est associé à l'angle de Cobb. Une étude longitudinale est nécessaire pour déterminer si le déjettement du tronc est un indicateur pronostique de la progression de la scoliose. Mots-clés: la scoliose idiopathique, le déjettement du tronc, fil à plomb, posture, déplacement latéral du tronc