1000 resultados para CIE coordinates


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Al(2)O(3):Eu(3+)(1%) samples were prepared by combustion, ceramic, and Pechini methods annealed from 400 to 1400 degrees C. XRD patterns indicate that samples heated up to 1000 degrees C present disordered character of activated alumina (gamma-Al(2)O(3)). However, alpha-Al(2)O(3) phase showed high crystallinity and thermostability at 1200-1400 degrees C. The sample characterizations were also carried out by means of infrared spectroscopy (IR), scanning electron microscopy (SEM) and specific surface areas analysis (BET method). Excitation spectra of Al(2)O(3):Eu(3+) samples present broaden bands attributed to defects of Al(2)O(3) matrices and to LMCT state of O -> Eu(3+), however, the narrow bands are assigned to (7)F(0) -> (5)D(J),(5)H(J) and (5)L(J) transitions of Eu(3+) ion. Emission spectra of samples calcined up to 1000 degrees C show broaden bands for (5)D(0) -> (7)F(J) transitions of Eu(3+) ion suggesting that the rare earth ion is in different symmetry sites showed by inhomogeneous line broadening of bands, confirming the predominance of the gamma-alumina phase. For all samples heated from 1200 to 1400 degrees C the spectra exhibit narrow (5)D(0) -> (7)F(J) transitions of Eu(3+) ion indicating the conversion of gamma to alpha-Al(2)O(3) phases, a high intensity narrow peak around 695 nm assigned to R lines of Cr(3+) ion is shown. Al(2)O(3):Eu(3+) heated up to 1100 degrees C presents an increase in the Omega(2) intensity parameter with the increase of temperatures enhancing the covalent character of metal-donor interaction. The disordered structural systems present the highest values of emission quantum efficiencies (eta). CIE coordinates of Al(2)O(3):Eu(3+) are also discussed. (C) 2007 Elsevier Inc. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the present work, the basic concepts of radiometric, photometric and colorimetric calibration are presented, which were applied to three light-emitting diodes (LEDs) used to compose the different color sensations that the human eye perceives in the visible region of the electromagnetic spectrum. In this sense, an experimental setup comprising a LED drive circuit and a home-made integrating sphere was assembled for the initial radiometric and photometric calibration as well as to obtain a set of intensity and spectral combinations associated to different colorimetric CIE (Commission Internationale de l'Eclairage) coordinates. The reader can, therefore, understand, in a simple manner, the process of color composition inside a color monitor or display picture element (pixel ). © Sociedade Brasileira de Física.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to analyze the color alterations performed by the CIE L*a*b* system in the digital imaging of shade guide tabs, which were obtained photographically according to the automatic and manual modes. This study also sought to examine the observers' agreement in quantifying the coordinates. Four Vita Lumin Vaccum shade guide tabs were used: A3.5, B1, B3 and C4. An EOS Canon digital camera was used to record the digital images of the shade tabs, and the images were processed using Adobe Photoshop software. A total of 80 observations (five replicates of each shade according to two observers in two modes, specifically, automatic and manual) were obtained, leading to color values of L*, a* and b*. The color difference (AE) between the modes was calculated and classified as either clinically acceptable or unacceptable. The results indicated that there was agreement between the two observers in obtaining the L*, a* and b* values related to all guides. However, the B1, B3, and C4 shade tabs had AE values classified as clinically acceptable (Delta E = 0.44, Delta E = 2.04 and Delta E = 2.69, respectively). The A3.5 shade tab had a AE value classified as clinically unacceptable (Delta E = 4.17), as it presented higher values for luminosity in the automatic mode (L* = 54.0) than in the manual mode (L* = 50.6). It was concluded that the B1, B3 and C4 shade tabs can be used at any of the modes in digital camera (manual or automatic), which was a different finding from that observed for the A3.5 shade tab.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this study was to assess the color change of three types of composite resins exposed to coffee and cola drink, and the effect of repolishing on the color stability of these composites after staining. MATERIALS AND METHODS: Fifteen specimens (15 mm diameter and 2 mm thick) were fabricated from microhybrid (Esthet-X; Dentsply and Filtek Z-250; 3M ESPE) and high-density hybrid (Surefil; Dentsply) composites, and were finished and polished with aluminum oxide discs (Sof-Lex; 3M ESPE). Color of the specimens was measured according to the CIE L*a*b* system in a refection spectrophotometer (PCB 6807; BYK Gardner). After baseline color measurements, 5 specimens of each resin were immersed in different staining solutions for 15 days: G1 - distilled water (control), G2 - coffee, G3 - cola soft drink. Afterwards, new color measurement was performed and the specimens were repolished and submitted to new color reading. Color stability was determined by the difference (ΔE) between the coordinates L*, a*, and b* obtained from the specimens before and after immersion into the solutions and after repolishing. RESULTS: There was no statistically signifcant difference (ANOVA, Tukey's test; p>0.05) among the ΔE values for the different types of composites after staining or repolishing. For all composite resins, coffee promoted more color change (ΔE>3.3) than distilled water and the cola soft drink. After repolishing, the ΔE values of the specimens immersed in coffee decreased to clinically acceptable values (ΔE<3.3), but remained signifcantly higher than those of the other groups. CONCLUSIONS: No signifcant difference was found among composite resins or between color values before and after repolishing of specimens immersed in distilled water and cola. Immersing specimens in coffee caused greater color change in all types of composite resins tested in this study and repolishing contributed to decrease staining to clinically acceptable ΔE values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The generator-coordinate method is a flexible and powerful reformulation of the variational principle. Here we show that by introducing a generator coordinate in the Kohn-Sham equation of density-functional theory, excitation energies can be obtained from ground-state density functionals. As a viability test, the method is applied to ground-state energies and various types of excited-state energies of atoms and ions from the He and the Li isoelectronic series. Results are compared to a variety of alternative DFT-based approaches to excited states, in particular time-dependent density-functional theory with exact and approximate potentials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The liver abscess is the most frequent extraintestinal complication of intestinal amoebiasis: its diagnosis is suggested by the clinical picture but it must be confirmed by paraclinic tests. Themost stringent diagnosis requires identification of E. histolytica. But this is possible only in a few cases. Serological tests greatly improve the diagnosis of this severe complication of amoebiasis. We compared the Enzyme Linfed Immunosorbent Assay and the Counterimmunoeletrophoresis techniques. Both techniques were used to detect amoebic antibodies in 50 control patients, 30 patients with liver abscess and 30 patients with intestinal amoebiasis. All the sera from control patients gave negative results iin both techniques. When analysing the sera from patients with intestinal amoebiasis, 10% of them were positive by ELISA but non by CIE. The sera of patients with liver abscess, we found that 90% were positive by the ELISA method and 66.6% by the CIE technique. In patients with amoebic liver abscess, the results showed that the ELISA was more sensitive than the CIE, as it presented a higher sensitivity (100%) than that of the CIE technique (66%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sementes de azedinha (Oxalis hirsutissima Mart. & Zuc.) apresentam um baixo percentual de germinação, dificultando a propagação dessa espécie medicinal, tão utilizada pelas populações tradicionais da região contra as inflamações oculares. Sementes coletadas de uma população nativa em Poconé, no Estado de Mato Grosso, foram submetidas a dois ensaios de quebra de dormência. No primeiro foram usados 12 tratamentos: pré-embebição em água por 24, 36, 48, 69 e 96 horas, imersão em acetona por 10 e 40 minutos, imersão em ácido clorídrico por 10 e 40 segundos, imersão em álcool etílico 96° por 10 e 40 segundos, e sem pré-tratamento. No segundo ensaio foram usados 14 tratamentos: imersão em água quente (70 ºC) por 20, 40, 60 e 300 segundos; em água muito quente (85 ºC) por 20, 40, 120 e 300 segundos, em água fervendo (100 °C) por 10, 20,40, 120 e 300 segundos, e sem pré-tratamento. A imersão em ácido clorídrico por 40 segundos diferiu estatisticamente dos demais, e mesmo assim a porcentagem de germinação foi baixa (47%). A imersão em água quente (70 ºC) por 300 segundos e em água muito quente (85 ºC) por 40 segundos mostraram os melhores resultados, com 89 e 92% de germinação, respectivamente. A água fervendo (100 ºC) por 300 segundos reduziu a percentagem de germinação a 4%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foram estudadas as mudanças micromorfotógicas e químicas que ocorrem na madeira de "açacu" Hura crepitans L. através de vários estágios de deterioração provocada pelos fungos Pycnoporus sanguineus (L.: F.) Murr, Antrodia albida (F.) Donk e Tyromyces sp. coletados nos arredores do município de Manaus, AM, Brasil. O microscópio eletrônico de varredura foi utilizado para a observação da extensão do ataque dos fungos aos diversos elementos xilemáticos de Hura crepitans. A otimização das condições de cultivo para os fungos foi estudada no que diz respeito ao efeito da temperatura e pH no crescimento micelial utilizando diferentes meios de cultura. Os fungos tendem a preferir um ambiente com pH entre 5.0-8.0 sendo o pH 6.0 o ótimo. A temperatura ótima ficou na faixa de 30-35 ºC. Ocorreu a perda progressiva do teor de lignina. Os polissacarídeos são degradados simultaneamente com a lignina, sendo que esta é degradada no estágio inicial com razão superior a dos polissacarídeos especialmente para P. sanguineus e Tyromyces sp. A medida que a lignina é removida, a estrutura fibrilar da celulose na parede celular torna-se evidente. Os elementos de vaso são completamente destruídos no estágio inicial da deterioração. Ocorre o estreitamento da parede celular dos elementos fibrosos adjacentes aos raios com ataque à parede primária e secundária. No estágio mais avançado de deterioração ocorre a destruição dos raios e a formação de cristais (presumivelmente oxalato de cálcio).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Uma nova espécie de Parabahita Linnavuori, 1959 é descrita e ilustrada: Parabahita caudata sp. nov. (Brasil, Rondônia)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Uma nova espécie de Amastris Stal, 1862, A. duckei sp.n., da Amazônia brasileira é descrita e ilustrada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sol-gel method was employed in the synthesis of di-urethane cross-linked poly( caprolactone) (PCL(530)/siloxane biohybrid ormolytes incorporating either a mixture of lithium triflate (LiCF3SO3) and the ionic liquid (IL) 1-ethyl-3-methyl imidazolium tetrafluoroborate ([Emim]BF4), or solely with [Emim]BF4 or LiCF3SO3. The ormolyte doped with [Emim]BF4 is thermally more stable and exhibits higher ionic conductivity (4 x 10-4 and 2 x 10-3 S cm-1 at 36 and 98 ºC, respectively) than those containing the LiCF3SO3/[Emim]BF4 mixture or just LiCF3SO3. The three ormolytes were employed in the production of glass/ITO/ormolyte/WO3/ITO/glass electrochromic devices (ECDs) designated as ECD@Y with Y = Li-[Emim]BF4, [Emim]BF4 and Li. The three ECDs displayed fast switching speed (ca. 30 s). ECD@Li-[Emim]BF4 exhibited an electrochromic contrast of 18.4 % and an optical density change of 0.11 in the visible region, the coloration efficiency attained at 555 nm was 159 and 80.2 cm-2 C-1 in the “on” and “off” states, respectively, and the open circuit memory was 48 hours. In the “on” state the CIE 1931 color space coordinates were x = 0.29 and y = 0.30, corresponding to blue color.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This chapter described the global and local coordinate systems utilized in the formulation of spatial multibody systems. Global coordinate system is considered in the present work to denote the inertia frame. Additionally, body-fixed coordinate systems, also called local coordinate systems, are utilized to describe local properties of points that belong to a particular body. Furthermore, the process of transforming local coordinates into global coordinates is characterized by considering a transformation matrix. In the present work, Cartesian coordinates are utilized to locate the center of mass of each rigid body, as well as the location of any point that belongs to a body.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This chapter describes the how the vector of coordinates are defined in the formulation of spatial multibody systems. For this purpose, the translational motion is described in terms of Cartesian coordinates, while rotational motion is specified using the technique of Euler parameters. This approach avoids the computational difficulties associated with the singularities in the case of using Euler angles or Bryant angles. Moreover, the formulation of the velocities vector and accelerations vector is presented and analyzed here. These two sets of vectors are defined in terms of translational and rotational coordinates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We aimed to determine whether human subjects' reliance on different sources of spatial information encoded in different frames of reference (i.e., egocentric versus allocentric) affects their performance, decision time and memory capacity in a short-term spatial memory task performed in the real world. Subjects were asked to play the Memory game (a.k.a. the Concentration game) without an opponent, in four different conditions that controlled for the subjects' reliance on egocentric and/or allocentric frames of reference for the elaboration of a spatial representation of the image locations enabling maximal efficiency. We report experimental data from young adult men and women, and describe a mathematical model to estimate human short-term spatial memory capacity. We found that short-term spatial memory capacity was greatest when an egocentric spatial frame of reference enabled subjects to encode and remember the image locations. However, when egocentric information was not reliable, short-term spatial memory capacity was greater and decision time shorter when an allocentric representation of the image locations with respect to distant objects in the surrounding environment was available, as compared to when only a spatial representation encoding the relationships between the individual images, independent of the surrounding environment, was available. Our findings thus further demonstrate that changes in viewpoint produced by the movement of images placed in front of a stationary subject is not equivalent to the movement of the subject around stationary images. We discuss possible limitations of classical neuropsychological and virtual reality experiments of spatial memory, which typically restrict the sensory information normally available to human subjects in the real world.