888 resultados para CENTRAL VENOUS-PRESSURE
Resumo:
PURPOSE Blood loss and blood substitution are associated with higher morbidity after major abdominal surgery. During major liver resection, low local venous pressure, has been shown to reduce blood loss. Ambiguity persists concerning the impact of local venous pressure on blood loss during open radical cystectomy. We aimed to determine the association between intraoperative blood loss and pelvic venous pressure (PVP) and determine factors affecting PVP. MATERIAL AND METHODS In the frame of a single-center, double-blind, randomized trial, PVP was measured in 82 patients from a norepinephrine/low-volume group and in 81 from a control group with liberal hydration. For this secondary analysis, patients from each arm were stratified into subgroups with PVP <5 mmHg or ≥5 mmHg measured after cystectomy (optimal cut-off value for discrimination of patients with relevant blood loss according to the Youden's index). RESULTS Median blood loss was 800 ml [range: 300-1600] in 55/163 patients (34%) with PVP <5 mmHg and 1200 ml [400-3000] in 108/163 patients (66%) with PVP ≥5 mmHg; (P<0.0001). A PVP <5 mmHg was measured in 42/82 patients (51%) in the norepinephrine/low-volume group and 13/81 (16%) in the control group (P<0.0001). PVP dropped significantly after removal of abdominal packing and abdominal lifting in both groups at all time points (at begin and end of pelvic lymph node dissection, end of cystectomy) (P<0.0001). No correlation between PVP and central venous pressure could be detected. CONCLUSIONS Blood loss was significantly reduced in patients with low PVP. Factors affecting PVP were fluid management and abdominal packing.
Resumo:
Objective. The information derived from central venous catheters is underused. We developed an EKG-R synchronization and averaging system to obtained distinct CVP waveforms and analyzed components of these. Methods. Twenty-five paralyzed surgical patients undergoing CVP monitoring under mechanical ventilation were studied. CVP and EKG signals were analyzed employing our system, the mean CVP and CVP at end-diastole during expiration were compared, and CVP waveform components were measured using this system. Results. CVP waveforms were clearly visualized in all patients. They showed the a peak to be 1.8+/- 0.7 mmHg, which was the highest of three peaks, and the x trough to be lower than the y trough (-1.6+/- 0.7mmHgand-0.9+/- 0.5mmHg, respectively), withameanpulsepressureof3.4mmHg.ThedifferencebetweenthemeanCVPandCVPatend-diastoleduringexpirationwas0.58+/- 0.81 mmHg. Conclusions. The mean CVP can be used as an index of right ventricular preload in patients under mechanical ventilation with regular sinus rhythm. Our newly developed system is useful for clinical monitoring and for education in circulatory physiology.
Resumo:
The effects of adrenergic stimulation on mean circulatory filling pressure (MCFP), central venous pressure (P-CV) and stroke volume (Vs), as well as the effects of altered MCFP through changes of blood volume were investigated in rattlesnakes (Crotalus durissus). MCFP is an estimate of the upstream pressure driving blood towards the heart and is determined by blood volume and the activity of the smooth muscle cells in the veins (venous tone). MCFP can be determined as the plateau in P-CV during a total occlusion of blood flow from the heart.Vs decreased significantly when MCFP was lowered by reducing blood volume in anaesthetised snakes, whereas increased MCFP through infusion of blood (up to 3 ml kg(-1)) only led to a small rise in Vs. Thus, it seems that end-diastolic volume is not affected by an elevated MCFP in rattlesnakes. To investigate adrenergic regulation on venous tone, adrenaline as well as phenylephrine and isoproterenol (alpha- and beta-adrenergic agonists, respectively) were infused as bolus injections (2 and 10 mu g kg(-1)). Adrenaline and phenylephrine caused large increases in MCFP and P-CV, whereas isoproterenol decreased both parameters. This was also the case in fully recovered snakes. Therefore, adrenaline affects venous tone through both alpha- and beta-adrenergic receptors, but the alpha-adrenergic receptor dominates at the dosages used in the present study. Injection of the nitric oxide donor SNP caused a significant decrease in P-CV and MCFP. Thus, nitric oxide seems to affect venous tone.
Resumo:
PURPOSE: To evaluate a widely used nontunneled triple-lumen central venous catheter in order to determine whether the largest of the three lumina (16 gauge) can tolerate high flow rates, such as those required for computed tomographic angiography. MATERIALS AND METHODS: Forty-two catheters were tested in vitro, including 10 new and 32 used catheters (median indwelling time, 5 days). Injection pressures were continuously monitored at the site of the 16-gauge central venous catheter hub. Catheters were injected with 300 and 370 mg of iodine per milliliter of iopamidol by using a mechanical injector at increasing flow rates until the catheter failed. The infusion rate, hub pressure, and location were documented for each failure event. The catheter pressures generated during hand injection by five operators were also analyzed. Mean flow rates and pressures at failure were compared by means of two-tailed Student t test, with differences considered significant at P < .05. RESULTS: Injections of iopamidol with 370 mg of iodine per milliliter generate more pressure than injections of iopamidol with 300 mg of iodine per milliliter at the same injection rate. All catheters failed in the tubing external to the patient. The lowest flow rate at which catheter failure occurred was 9 mL/sec. The lowest hub pressure at failure was 262 pounds per square inch gauge (psig) for new and 213 psig for used catheters. Hand injection of iopamidol with 300 mg of iodine per milliliter generated peak hub pressures ranging from 35 to 72 psig, corresponding to flow rates ranging from 2.5 to 5.0 mL/sec. CONCLUSION: Indwelling use has an effect on catheter material property, but even for used catheters there is a substantial safety margin for power injection with the particular triple-lumen central venous catheter tested in this study, as the manufacturer's recommendation for maximum pressure is 15 psig.
Resumo:
It has been established that mixed venous oxygen saturation (SvO2) reflects the balance between systemic oxygen deliver y and consumption. Literature indicates that it is a valuable clinical indicator and has good prognostic value early in patient course. This article aims to establish the usefulness of SvO2 as a clinical indicator. A secondary aim was to determine whether central venous oxygen saturation (ScvO2) and SvO2 are interchangeable. Of particular relevance to cardiac nurses is the link between decreased SvO2 and cardiac failure in patients with myocardial infarction, and with decline in myocardial function, clinical shock and arrhythmias. While absolute values ScvO2 and SvO2 are not interchangeable, ScvO2 and SvO2are equivalent in terms of clinical course. Additionally, ScvO2 monitoring is a safer and less costly alternative to SvO2 monitoring. It can be concluded that continuous ScvO2 monitoring should potentially be undertaken in patients at risk of haemodynamic instability.
Resumo:
Background: A bundled approach to central venous catheter care is currently being promoted as an effective way of preventing catheter-related bloodstream infection (CR-BSI). Consumables used in the bundled approach are relatively inexpensive which may lead to the conclusion that the bundle is cost-effective. However, this fails to consider the nontrivial costs of the monitoring and education activities required to implement the bundle, or that alternative strategies are available to prevent CR-BSI. We evaluated the cost-effectiveness of a bundle to prevent CR-BSI in Australian intensive care patients. ---------- Methods and Findings: A Markov decision model was used to evaluate the cost-effectiveness of the bundle relative to remaining with current practice (a non-bundled approach to catheter care and uncoated catheters), or use of antimicrobial catheters. We assumed the bundle reduced relative risk of CR-BSI to 0.34. Given uncertainty about the cost of the bundle, threshold analyses were used to determine the maximum cost at which the bundle remained cost-effective relative to the other approaches to infection control. Sensitivity analyses explored how this threshold alters under different assumptions about the economic value placed on bed-days and health benefits gained by preventing infection. If clinicians are prepared to use antimicrobial catheters, the bundle is cost-effective if national 18-month implementation costs are below $1.1 million. If antimicrobial catheters are not an option the bundle must cost less than $4.3 million. If decision makers are only interested in obtaining cash-savings for the unit, and place no economic value on either the bed-days or the health benefits gained through preventing infection, these cost thresholds are reduced by two-thirds.---------- Conclusions: A catheter care bundle has the potential to be cost-effective in the Australian intensive care setting. Rather than anticipating cash-savings from this intervention, decision makers must be prepared to invest resources in infection control to see efficiency improvements.
Resumo:
Background: Greater research utilisation in cancer nursing practice is needed, in order to provide well-informed and effective nursing care to people affected by cancer. This paper aims to report on the implementation of evidence-based practice in a tertiary cancer centre. Methods: Using a case report design, this paper reports on the use of the Collaborative Model for Evidence Based Practice (CMEBP) in an Australian tertiary cancer centre. The clinical case is the uptake of routine application of chlorhexidine-impregnated sponge dressings for preventing centrally inserted catheter-related bloodstream infections. In this case report, a number of processes that resulted in a service-wide practice change are described. Results: This model was considered a feasible method for successful research utilisation. In this case report, chlorhexidine-impregnated sponge dressings were proposed and implemented in the tertiary cancer centre with an aim of reducing the incidence of centrally inserted catheter-related bloodstream infections and potentially improving patient health outcomes. Conclusion: The CMEBP is feasible and effective for implementing clinical evidence into cancer nursing practice. Cancer nurses and health administrators need to ensure a supportive infrastructure and environment for clinical inquiry and research utilisation exists, in order to enable successful implementation of evidence-based practice in their cancer centres.
Resumo:
Background Guidelines and clinical practice for the prevention of complications associated with central venous catheters (CVC) around the world vary greatly. Most institutions recommend the use of heparin to prevent occlusion, however there is debate regarding the need for heparin and evidence to suggest 0.9% sodium chloride (normal saline) may be as effective. The use of heparin is not without risk, may be unnecessary and is also associated with increased cost. Objectives To assess the clinical effects (benefits and harms) of intermittent flushing of heparin versus normal saline to prevent occlusion in long term central venous catheters in infants and children. Search Methods The Cochrane Vascular Trials Search Co-ordinator searched the Specialised Register (last searched April 2015) and the Cochrane Register of Studies (Issue 3, 2015). We also searched the reference lists of retrieved trials. Selection criteria Randomised controlled trials that compared the efficacy of normal saline with heparin to prevent occlusion of long term CVCs in infants and children aged up to 18 years of age were included. We excluded temporary CVCs and peripherally inserted central catheters (PICC). Data Collection and Analysis Two review authors independently assessed trial inclusion criteria, trial quality and extracted data. Rate ratios were calculated for two outcome measures - occlusion of the CVC and central line-associated blood stream infection. Other outcome measures included duration of catheter placement, inability to withdraw blood from the catheter, use of urokinase or recombinant tissue plasminogen, incidence of removal or re-insertion of the catheter, or both, and other CVC-related complications such as dislocation of CVCs, other CVC site infections and thrombosis. Main Results Three trials with a total of 245 participants were included in this review. The three trials directly compared the use of normal saline and heparin, however, between studies, all used different protocols for the standard and experimental arms with different concentrations of heparin and different frequency of flushes reported. In addition, not all studies reported on all outcomes. The quality of the evidence ranged from low to very low because there was no blinding, heterogeneity and inconsistency between studies was high and the confidence intervals were wide. CVC occlusion was assessed in all three trials (243 participants). We were able to pool the results of two trials for the outcomes of CVC occlusion and CVC-associated blood stream infection. The estimated rate ratio for CVC occlusion per 1000 catheter days between the normal saline and heparin group was 0.75 (95% CI 0.10 to 5.51, two studies, 229 participants, very low quality evidence). The estimated rate ratio for CVC-associated blood stream infection was 1.48 (95% CI 0.24 to 9.37, two studies, 231 participants; low quality evidence). The duration of catheter placement was reported to be similar between the two study arms, in one study (203 participants). Authors' Conclusions The review found that there was not enough evidence to determine the effects of intermittent flushing of heparin versus normal saline to prevent occlusion in long term central venous catheters in infants and children. Ultimately, if this evidence were available, the development of evidenced-based clinical practice guidelines and consistency of practice would be facilitated.
Resumo:
Background People admitted to intensive care units and those with chronic health care problems often require long-term vascular access. Central venous access devices (CVADs) are used for administering intravenous medications and blood sampling. CVADs are covered with a dressing and secured with an adhesive or adhesive tape to protect them from infection and reduce movement. Dressings are changed when they become soiled with blood or start to come away from the skin. Repeated removal and application of dressings can cause damage to the skin. The skin is an important barrier that protects the body against infection. Less frequent dressing changes may reduce skin damage, but it is unclear whether this practice affects the frequency of catheter-related infections. Objectives To assess the effect of the frequency of CVAD dressing changes on the incidence of catheter-related infections and other outcomes including pain and skin damage. Search methods In June 2015 we searched: The Cochrane Wounds Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE and EBSCO CINAHL. We also searched clinical trials registries for registered trials. There were no restrictions with respect to language, date of publication or study setting. Selection criteria All randomised controlled trials (RCTs) evaluating the effect of the frequency of CVAD dressing changes on the incidence of catheter-related infections on all patients in any healthcare setting. Data collection and analysis We used standard Cochrane review methodology. Two review authors independently assessed studies for inclusion, performed risk of bias assessment and data extraction. We undertook meta-analysis where appropriate or otherwise synthesised data descriptively when heterogeneous. Main results We included five RCTs (2277 participants) that compared different frequencies of CVAD dressing changes. The studies were all conducted in Europe and published between 1995 and 2009. Participants were recruited from the intensive care and cancer care departments of one children's and four adult hospitals. The studies used a variety of transparent dressings and compared a longer interval between dressing changes (5 to15 days; intervention) with a shorter interval between changes (2 to 5 days; control). In each study participants were followed up until the CVAD was removed or until discharge from ICU or hospital. - Confirmed catheter-related bloodstream infection (CRBSI) One trial randomised 995 people receiving central venous catheters to a longer or shorter interval between dressing changes and measured CRBSI. It is unclear whether there is a difference in the risk of CRBSI between people having long or short intervals between dressing changes (RR 1.42, 95% confidence interval (CI) 0.40 to 4.98) (low quality evidence). - Suspected catheter-related bloodstream infection Two trials randomised a total of 151 participants to longer or shorter dressing intervals and measured suspected CRBSI. It is unclear whether there is a difference in the risk of suspected CRBSI between people having long or short intervals between dressing changes (RR 0.70, 95% CI 0.23 to 2.10) (low quality evidence). - All cause mortality Three trials randomised a total of 896 participants to longer or shorter dressing intervals and measured all cause mortality. It is unclear whether there is a difference in the risk of death from any cause between people having long or short intervals between dressing changes (RR 1.06, 95% CI 0.90 to 1.25) (low quality evidence). - Catheter-site infection Two trials randomised a total of 371 participants to longer or shorter dressing intervals and measured catheter-site infection. It is unclear whether there is a difference in risk of catheter-site infection between people having long or short intervals between dressing changes (RR 1.07, 95% CI 0.71 to 1.63) (low quality evidence). - Skin damage One small trial (112 children) and three trials (1475 adults) measured skin damage. There was very low quality evidence for the effect of long intervals between dressing changes on skin damage compared with short intervals (children: RR of scoring ≥ 2 on the skin damage scale 0.33, 95% CI 0.16 to 0.68; data for adults not pooled). - Pain Two studies involving 193 participants measured pain. It is unclear if there is a difference between long and short interval dressing changes on pain during dressing removal (RR 0.80, 95% CI 0.46 to 1.38) (low quality evidence). Authors' conclusions The best available evidence is currently inconclusive regarding whether longer intervals between CVAD dressing changes are associated with more or less catheter-related infection, mortality or pain than shorter intervals.
Resumo:
Background Around the world, guidelines and clinical practice for the prevention of complications associated with central venous catheters (CVC) vary greatly. To prevent occlusion, most institutions recommend the use of heparin when the CVC is not in use. However, there is debate regarding the need for heparin and evidence to suggest normal saline may be as effective. The use of heparin is not without risk, may be unnecessary and is also associated with increased costs. Objectives To assess the clinical effects (benefits and harms) of heparin versus normal saline to prevent occlusion in long-term central venous catheters in infants, children and adolescents. Design A Cochrane systematic review of randomised controlled trials was undertaken. - Data sources: The Cochrane Vascular Group Specialised Register (including MEDLINE, CINAHL, EMBASE and AMED) and the Cochrane Register of Studies were searched. Hand searching of relevant journals and reference lists of retrieved articles was also undertaken. - Review Methods: Data were extracted and appraisal undertaken. We included studies that compared the efficacy of normal saline with heparin to prevent occlusion. We excluded temporary CVCs and peripherally inserted central catheters. Rate ratios per 1000 catheter days were calculated for two outcomes, occlusion of the CVC, and CVC-associated blood stream infection. Results Three trials with a total of 245 participants were included in this review. The three trials directly compared the use of normal saline and heparin. However, between studies, all used different protocols with various concentrations of heparin and frequency of flushes. The quality of the evidence ranged from low to very low. The estimated rate ratio for CVC occlusion per 1000 catheter days between the normal saline and heparin group was 0.75 (95% CI 0.10 to 5.51, two studies, 229 participants, very low quality evidence). The estimated rate ratio for CVC-associated blood stream infection was 1.48 (95% CI 0.24 to 9.37, two studies, 231 participants; low quality evidence). Conclusions It remains unclear whether heparin is necessary for CVC maintenance. More well-designed studies are required to understand this relatively simple, but clinically important question. Ultimately, if this evidence were available, the development of evidenced-based clinical practice guidelines and consistency of practice would be facilitated.
Resumo:
BACKGROUND: Central Venous Catheterisation (CVC) has occasionally been associated with cases of retained guidewires in patients after surgery. In theory, this is a completely avoidable complication; however, as with any human procedure, operator error leading to guidewires being occasionally retained cannot be fully eliminated. OBJECTIVE: The work described here investigated the issue in an attempt to better understand it both from an operator and a systems perspective, and to ultimately recommend appropriate safe design solutions that reduce guidewire retention errors. METHODS: Nine distinct methods were used: observations of the procedure, a literature review, interviewing CVC end-users, task analysis construction, CVC procedural audits, two human reliability assessments, usability heuristics and a comprehensive solution survey with CVC end-users. RESULTS: The three solutions that operators rated most highly, in terms of both practicality and effectiveness, were: making trainees better aware of the potential guidewire complications and strongly emphasising guidewire removal in CVC training, actively checking that the guidewire is present in the waste tray for disposal, and standardising purchase of central line sets so that differences that may affect chances of guidewire loss is minimised. CONCLUSIONS: Further work to eliminate/engineer out the possibility of guidewires being retained is proposed.
Resumo:
The impact of the alternative sigma factor sigma B (SigB) on pathogenesis of Staphylococcus aureus is not conclusively clarified. In this study, a central venous catheter (CVC) related model of multiorgan infection was used to investigate the role of SigB for the pathogenesis of S. aureus infections and biofilm formation in vivo. Analysis of two SigB-positive wild-type strains and their isogenic mutants revealed uniformly that the wild-type was significantly more virulent than the SigB-deficient mutant. The observed difference in virulence was apparently not linked to the capability of the strains to form biofilms in vivo since wild-type and mutant strains were able to produce biofilm layers inside of the catheter. The data strongly indicate that the alternative sigma factor SigB plays a role in CVC-associated infections caused by S. aureus.