963 resultados para Bus-bar Coupling


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Large amplitude bus bar aeolian vibration may lead to post insulator damage. Different damping applications are used to decrease the risk of large amplitude aeolian vibration. In this paper the post insulator load caused by the bus bar aeolian vibration and the effect of damping methods are evaluated. The effects of three types of bus bar connectors and three types of primary structures are studied. Two actual damping devices, damping cable and their combinations are studied. The post insulator loads are studied with strain gage based custom made force sensors installed on the both ends of the post insulator and with the displacement sensor installed on the midpoint of the bus bar. The post insulator loads are calculated from the strain values and the damping properties are determined from the displacement history. The bus bar is deflected with a hanging weight. The weight is released and the bus bar is left to free damped vibration. Both actual bus bar vibration dampers RIBE and SBI were very effective against the aeolian vibration. Combining vibration damper with damping cable will increase the damping ratio but it may be unnecessary considering the extra effort. Bus bar connector type or primary structure have no effect on the vertical load. The bending moment at the post insulator with double sided bus bar connector is significantly higher than at the post insulator with single sided bus bar connector. No reliable conclusions about bus bar connector type effect can be done, but the roller bearing type or central bearing type connector may reduce the bending moment. The RHS steel frame as primary structure may increase the bending moment peak values since it is the least rigid primary structure type and it may start to vibrate as a response to the awakening force of the vibrating bus bar.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The e(+)e(-)-->b (B) over bar nu(ν) over bar process, where nu is an electron, muon, or tau-lepton neutrino, is analyzed in detail for the general form of the coupling constant of a Higgs boson with b quarks, with the (m(b)/v)(a + igamma(5)b) parameterization of the Hb (b) over bar interaction. This process is shown to be highly sensitive to this coupling constant. Experiments at the future with roots = 500-GeV linear collider will provide limits of 2 and 20% for deviations of the parameters a and b, respectively, from their Standard Model values. Results concerning the e(+)e(-)-->b (b) over bar nu(ν) over bar process in combination with the independent measurements of the partial width Gamma(H --> b (b) over bar) can testify to the CP origin of the Higgs sector of the theory. (C) 2003 MAIK Nauka/Interperiodica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A complete analysis of the sensitivity to new Hbb̄ couplings from the process e+e- → bb̄vv̄ at the next generation of linear colliders was performed. These new couplings were predicted by many extensions of the Standard Model. The results are comparable to the study performed previously where a global fit analysis for L=500 fb-1 and √s=500 GeV resulted in a relative accuracy of 2.2% in the gHbb Yukawa coupling.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eventually, violations of voltage limits at buses or admissible loadings of transmission lines and/or power transformers may occur by the power system operation. If violations are detected in the supervision process, corrective measures may be carried out in order to eliminate them or to reduce their intensity. Loading restriction is an extreme solution and should only be adopted as the last control action. Previous researches have shown that it is possible to control constraints in electrical systems by changing the network topology, using the technique named Corrective Switching, which requires no additional costs. In previous works, the proposed calculations for verifying the ability of a switching variant in eliminating an overload in a specific branch were based on network reduction or heuristic analysis. The purpose of this work is to develop analytical derivation of linear equations to estimate current changes in a specific branch (due to switching measures) by means of few calculations. For bus-bar coupling, derivations will be based on short-circuit theory and Relief Function methodology. For bus-bar splitting, a Relief Function will be derived based on a technique of equivalent circuit. Although systems of linear equations are used to substantiate deductions, its formal solution for each variant, in real time does not become necessary. A priority list of promising variants is then assigned for final check by an exact load flow calculation and a transient analysis using ATP Alternative Transient Program. At last, results obtained by simulation in networks with different features will be presented

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Most algorithms for state estimation based on the classical model are just adequate for use in transmission networks. Few algorithms were developed specifically for distribution systems, probably because of the little amount of data available in real time. Most overhead feeders possess just current and voltage measurements at the middle voltage bus-bar at the substation. In this way, classical algorithms are of difficult implementation, even considering off-line acquired data as pseudo-measurements. However, the necessity of automating the operation of distribution networks, mainly in regard to the selectivity of protection systems, as well to implement possibilities of load transfer maneuvers, is changing the network planning policy. In this way, some equipments incorporating telemetry and command modules have been installed in order to improve operational features, and so increasing the amount of measurement data available in real-time in the System Operation Center (SOC). This encourages the development of a state estimator model, involving real-time information and pseudo-measurements of loads, that are built from typical power factors and utilization factors (demand factors) of distribution transformers. This work reports about the development of a new state estimation method, specific for radial distribution systems. The main algorithm of the method is based on the power summation load flow. The estimation is carried out piecewise, section by section of the feeder, going from the substation to the terminal nodes. For each section, a measurement model is built, resulting in a nonlinear overdetermined equations set, whose solution is achieved by the Gaussian normal equation. The estimated variables of a section are used as pseudo-measurements for the next section. In general, a measurement set for a generic section consists of pseudo-measurements of power flows and nodal voltages obtained from the previous section or measurements in real-time, if they exist -, besides pseudomeasurements of injected powers for the power summations, whose functions are the load flow equations, assuming that the network can be represented by its single-phase equivalent. The great advantage of the algorithm is its simplicity and low computational effort. Moreover, the algorithm is very efficient, in regard to the accuracy of the estimated values. Besides the power summation state estimator, this work shows how other algorithms could be adapted to provide state estimation of middle voltage substations and networks, namely Schweppes method and an algorithm based on current proportionality, that is usually adopted for network planning tasks. Both estimators were implemented not only as alternatives for the proposed method, but also looking for getting results that give support for its validation. Once in most cases no power measurement is performed at beginning of the feeder and this is required for implementing the power summation estimations method, a new algorithm for estimating the network variables at the middle voltage bus-bar was also developed

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We perform an update of our previous analysis of the constraints on possible deviations of Hb (b) over bar coupling parametrized as (m(b)/v)(a+igamma(5)b), arising from a scalar-pseudoscalar mixing, where the process e(+)e(-)-->b (b) over bar nu(ν) over bar was used. In this paper we include a complete simulation of the process e(+)e(-)-->b (b) over bare(+)e(-) and combine these results to obtain tighter bounds on the deviations of the parameters a and b from their standard model values that could be measured at the Next Linear Collider.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Este trabalho propõe uma estratégia fuzzy, do tipo Rede de Controladores Locais, aplicável à melhoria da estabilidade dinâmica em sistemas elétricos de potência, visando compensar possíveis perdas de sintonia devido à ocorrência de variações nas condições operacionais da planta. A adaptação dos ganhos do controlador fuzzy é efetuada on-line, interpolando-se os ganhos de um conjunto finito de controladores locais fixos. Ao ocorrer variações nas condições operacionais da planta, os ganhos da lei de controle são ajustados automaticamente de modo a manter satisfatório o desempenho do sistema de controle. O desempenho do controle foi avaliado através de estudos de simulação, utilizando-se um modelo dinâmico não-linear, do tipo máquina barra infinita. Os resultados mostram que o emprego da estratégia proposta permite obter melhorias no desempenho dinâmico do sistema.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In weak grids, an important problem with voltage stability and protections coordination of power plants exists. This problem appears because all the generation groups are connected to the same bus bar. As a result, if a fault occurs in any of the generation groups, or in the bus bar that connect them, the system voltage will have large oscillations. Hence, in weak grids the correct adjustment of AVR (Automatic Voltage Regulator) is critical. In this work an experimental study of differents AVR adjustments against fault in weak grids is described.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work the failure analysis carried out in III-V concentrator multijunction solar cells after a temperature accelerated life test is presented. All the failures appeared have been catastrophic since all the solar cells turned into low shunt resistances. A case study in failure analysis based on characterization by optical microscope, SEM, EDX, EQE and XPS is presented in this paper, revealing metal deterioration in the bus bar and fingers as well as cracks in the semiconductor structure beneath or next to the bus bar. In fact, in regions far from the bus bar the semiconductor structure seems not to be damaged. SEM images have dismissed the presence of metal spikes inside the solar cell structure. Therefore, we think that for these particular solar cells, failures appear mainly as a consequence of a deficient electrolytic growth of the front metallization which also results in failures in the semiconductor structure close to the bus bars.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We explicitly construct a stationary coupling attaining Ornstein`s (d) over bar -distance between ordered pairs of binary chains of infinite order. Our main tool is a representation of the transition probabilities of the coupled bivariate chain of infinite order as a countable mixture of Markov transition probabilities of increasing order. Under suitable conditions on the loss of memory of the chains, this representation implies that the coupled chain can be represented as a concatenation of i.i.d. sequences of bivariate finite random strings of symbols. The perfect simulation algorithm is based on the fact that we can identify the first regeneration point to the left of the origin almost surely.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We evaluate the mass of the B(s0) scalar meson and the coupling constant in the B(s0)BK vertex in the framework of QCD sum rules. We consider the B(s0) as a tetraquark state to evaluate its mass. We get m(Bs0) = (5.85 +/- 0.13) GeV, which is in agreement, considering the uncertainties, with predictions supposing it as a b (s) over bar state or a B (K) over bar bound state with J(P) = 0(+). To evaluate the g(Bs0BK) coupling, we use the three-point correlation functions of the vertex, considering B(s0) as a normal b (s) over bar state. The obtained coupling constant is: g(Bs0BK) = (16.3 +/- 3.2) GeV. This number is in agreement with light-cone QCD sum rules calculation. We have also compared the decay width of the B(s0) -> BK process considering the B(s0) to be a b (s) over bar state and a BK molecular state. The width obtained for the BK molecular state is twice as big as the width obtained for the b (s) over bar state. Therefore, we conclude that with the knowledge of the mass and the decay width of the B(s0) meson, one can discriminate between the different theoretical proposals for its structure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two integrable quantum spin ladder systems will be introduced associated with the fundamental su(2 \2) solution of the Yang-Baxter equation. The first model is a generalized quantum Ising system with Ising rung interactions. In the second model the addition of extra interactions allows us to impose Heisenberg rung interactions without violating integrability. The existence of a Bethe ansatz solution for both models allows us to investigate the elementary excitations for antiferromagnetic rung couplings. We find that the first model does not show a gap whilst in the second case there is a gap for all positive values of the rung coupling.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We use the recently obtained theoretical expression for the complete QCD static energy at next-to-next-to-next-to leading-logarithmic accuracy to determine r(0)Lambda((MS) over bar) by comparison with available lattice data, where r(0) is the lattice scale and Lambda((MS) over bar) is the QCD scale. We obtain r(0)Lambda((MS) over bar) = 0.622(-0.015)(+0.019) for the zero-flavor case. The procedure we describe can be directly used to obtain r(0)Lambda((MS) over bar) in the unquenched case, when unquenched lattice data for the static energy at short distances becomes available. Using the value of the strong coupling alpha(s) as an input, the unquenched result would provide a determination of the lattice scale r(0).