288 resultados para Borg MOEA
Resumo:
This study contributes a rigorous diagnostic assessment of state-of-the-art multiobjective evolutionary algorithms (MOEAs) and highlights key advances that the water resources field can exploit to better discover the critical tradeoffs constraining our systems. This study provides the most comprehensive diagnostic assessment of MOEAs for water resources to date, exploiting more than 100,000 MOEA runs and trillions of design evaluations. The diagnostic assessment measures the effectiveness, efficiency, reliability, and controllability of ten benchmark MOEAs for a representative suite of water resources applications addressing rainfall-runoff calibration, long-term groundwater monitoring (LTM), and risk-based water supply portfolio planning. The suite of problems encompasses a range of challenging problem properties including (1) many-objective formulations with 4 or more objectives, (2) multi-modality (or false optima), (3) nonlinearity, (4) discreteness, (5) severe constraints, (6) stochastic objectives, and (7) non-separability (also called epistasis). The applications are representative of the dominant problem classes that have shaped the history of MOEAs in water resources and that will be dominant foci in the future. Recommendations are provided for which modern MOEAs should serve as tools and benchmarks in the future water resources literature.
Resumo:
The use of adaptive wing/aerofoil designs is being considered as promising techniques in aeronautic/aerospace since they can reduce aircraft emissions, improve aerodynamic performance of manned or unmanned aircraft. The paper investigates the robust design and optimisation for one type of adaptive techniques; Active Flow Control (AFC) bump at transonic flow conditions on a Natural Laminar Flow (NLF) aerofoil designed to increase aerodynamic efficiency (especially high lift to drag ratio). The concept of using Shock Control Bump (SCB) is to control supersonic flow on the suction/pressure side of NLF aerofoil: RAE 5243 that leads to delaying shock occurrence or weakening its strength. Such AFC technique reduces total drag at transonic speeds due to reduction of wave drag. The location of Boundary Layer Transition (BLT) can influence the position the supersonic shock occurrence. The BLT position is an uncertainty in aerodynamic design due to the many factors, such as surface contamination or surface erosion. The paper studies the SCB shape design optimisation using robust Evolutionary Algorithms (EAs) with uncertainty in BLT positions. The optimisation method is based on a canonical evolution strategy and incorporates the concepts of hierarchical topology, parallel computing and asynchronous evaluation. Two test cases are conducted; the first test assumes the BLT is at 45% of chord from the leading edge and the second test considers robust design optimisation for SCB at the variability of BLT positions and lift coefficient. Numerical result shows that the optimisation method coupled to uncertainty design techniques produces Pareto optimal SCB shapes which have low sensitivity and high aerodynamic performance while having significant total drag reduction.
Resumo:
Generating manipulator trajectories considering multiple objectives and obstacle avoidance is a non-trivial optimization problem. In this paper a multi-objective genetic algorithm based technique is proposed to address this problem. Multiple criteria are optimized considering up to five simultaneous objectives. Simulation results are presented for robots with two and three degrees of freedom, considering two and five objectives optimization. A subsequent analysis of the spread and solutions distribution along the converged non-dominated Pareto front is carried out, in terms of the achieved diversity.
Resumo:
Porvoon kartta. - 1 kartta : vär. ; 40 x 53,7 cm, lehti 45 x 60 cm. - Mittakaava [1:4000]. - Sisältää luettelot kortteleista ja julkisista rakennuksista.
Resumo:
Mittakaava laskettu janamittakaavasta
Resumo:
Kartan esitystekniikka: maastokartta
Resumo:
Objective: To examine the interpretation of the verbal anchors used in the Borg rating of perceived exertion (RPE) scales in different clinical groups and a healthy control group. Design: Prospective experimental study. Setting: Rehabilitation center. Participants: Nineteen subjects with brain injury, 16 with chronic low back pain (CLBP), and 20 healthy controls. Interventions: Not applicable. Main Outcome Measures: Subjects used a visual analog scale (VAS) to rate their interpretation of the verbal anchors from the Borg RPE 6-20 and the newer 10-point category ratio scale. Results: All groups placed the verbal anchors in the order that they occur on the scales. There were significant within-group differences (P > .05) between VAS scores for 4 verbal anchors in the control group, 8 in the CLBP group, and 2 in the brain injury group. There was no significant difference in rating of each verbal anchor between the groups (P > .05). Conclusions: All subjects rated the verbal anchors in the order they occur on the scales, but there was less agreement in rating of each verbal anchor among subjects in the brain injury group. Clinicians should consider the possibility of small discrepancies in the meaning of the verbal anchors to subjects, particularly those recovering from brain injury, when they evaluate exercise perceptions.
Resumo:
In the competitive judo, the form as a trainer organizes the process of his/her athlete's training is a very important task for a good acting and a better use of the technical procedures. There is great importance in determining the exercise intensity for the judocas training due to the interest for the high income in several competitions, and few studies returned for this research area, involving those athletes' different physiologic conditions. Therefore, it is necessary to improve protocols of physical evaluation for this modality, increasing his/her applicability. The present study aimed at to verify the validity of a protocol of specific aerobic test of the judo (technique ipon-seoi-nague), no exhausting, adapted of the method of CHASSAIN (1986), using deltas of variations of the lactacidemia and of the Scale of Perception of Effort of Borg, in athletes well. The test adapted to the judo constituted of four exercise series with two efforts similar (double) of 180 seconds with one interval of 90 seconds among them. The series of exercises were accomplished in consecutive days. The intensities of the double tests were of 85%, 95%, 105% and 115% of the minimum lactato for each participant. This work used the technique ipon-seoi-nague, obeying the reasons effort-pause individualized for each athlete, that you/they correspond to the intensities of exercises proposed by the protocol of CHASSAIN (1986). In that way, the athletes applied a blow (maximum speed) and they rested some seconds, depending on the regime effort-pause of the session. At the end of each collection collection of blood (25NL) of each participant's earlobe was accomplished, seeking to measure the concentration of sanguine lactato. The collections were accomplished at the end of the first and of the second efforts, in each one of the series. For the analysis of the Perception of the athletes' Effort, the Scale of Perception... (Complete abstract click electronic access below)
Resumo:
O presente estudo objetivou verificar a validade de um protocolo de teste aeróbio específico do judô (técnica ipon-seoi-nague), não exaustivo, adaptado do método de CHASSAIN (1986), utilizando deltas de variações da escala de percepção de Borg e da freqüência cardíaca em atletas bem treinados. O teste adaptado ao judô constituiu de quatro séries de exercício com dois esforços iguais (duplos) de 180 segundos com um intervalo de 90 segundos entre eles. As séries de exercícios foram realizadas em dias consecutivos. As intensidades dos testes duplos foram de 85%, 95%,105% e 115% do lactato mínimo para cada participante. Este trabalho utilizou a técnica ipon-seoi-nague, sendo que as razões esforço-pausa foram específicas para cada atleta, e correspondem às intensidades de exercício propostas pelo protocolo de Chassain (1986). A escala de percepção de esforço de Borg foi mostrada ao final do primeiro e do segundo esforços, em cada uma das séries, para que o atleta determinasse o nível de cansaço. Para análise da freqüência cardíaca foi utilizado um freqüencímetro, Polar Vantage NV, obtendo freqüência cardíaca concomitantemente a escala de Borg, ao final de bloco de esforço. Dessa maneira, foram obtidos dois deltas de variações entre o primeiro e o segundo esforços, para escala de percepção de Borg (ΔBORG) e FC (ΔFC). Uma vez que foram utilizadas quatro intensidades, foi possível determinar quatro ΔBORG e quatro ΔFC. Assim, a partir de duas regressões lineares (uma para o Borg e outra para a FC), foi possível determinar as razões esforço:pausas críticas do exercício na técnica específica do Judô, a partir da determinação das intensidades nas quais a variação de Borg e da FC foi igual a zero (ΔBORG=0 e ΔFC=0). Para validar esses procedimentos adaptados de Chassain (1986) ao Judô, foi realizado o teste de Lactato Mínimo Adaptado, conforme sugerido por Azevedo (2002).
Manipulation effects of prior exercise intensity feedback by the Borg scale during open-loop cycling
Resumo:
Objective To verify the effects of exercise intensity deception by the Borg scale on the ratings of perceived exertion (RPE), heart rate (HR) and performance responses during a constant power output open-loop exercise. Methods Eight healthy men underwent a maximal incremental test on a cycle ergometer to identify the peak power output (PPO) and heart rate deflection point (HRDP). Subsequently, they performed a constant power output trial to exhaustion set at the HRDP intensity, in deception (DEC) and informed (INF) conditions: DEC-subjects were told that they would be cycling at an intensity corresponding to two categories below the RPE quantified at the HRDP; INF-subjects were told that they would cycle at the exact intensity corresponding to the RPE quantified at the HRDP. Results The PPO and power output at the HRDP obtained in maximal incremental tests were 247.5 +/- 32.1 W and 208.1 +/- 27.1 W, respectively. No significant difference in the time to exhaustion was found between DEC (525 +/- 244 s) or INF (499 +/- 224 s) trials. The slope and the first and second measurements of the RPE and HR parameters showed no significant difference between trials. Conclusions Psychophysiological variables such as RPE and HR as well as performance were not affected when exercise intensity was deceptively manipulated via RPE scores. This may suggest that unaltered RPE during exercise is a regulator of performance in this open-loop exercise.
Resumo:
Includes index.