987 resultados para Bone level


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Alcohol consumption is a risk indicator for periodontal disease. The purpose of this study was to morphometrically evaluate the influence of alcohol consumption on alveolar bone level associated with ligature-induced periodontitis in rats. Thirty-six female rats (Wistar, 120 days-old) were randomly divided into three groups that received a daily administration of a water diet (control, n = 12), a 10% alcohol diet (10% ethanol, n = 12) or a 20% alcohol diet (20% ethanol, n = 12). Four weeks after the onset of the experiment, cotton ligatures were placed around the cervix of the upper right second molar in six rats. The other 6 rats in each group remained unligated. The rats were sacrificed four weeks after ligature placement. The maxillary bones were removed and alveolar bone loss was analyzed by measuring the distance between the cementoenamel junction and the alveolar bone crest at 2 buccal and 2 palatal sites on the upper right second molar. Analyses between the ligated and unligated groups showed that the presence of ligature induced alveolar bone loss (p < 0.05). Unligated groups showed no significant differences between each other (p > 0.05). In the ligated groups, rats receiving 20% ethanol showed significantly greater bone loss compared to control rats or rats receiving 10% ethanol. These results demonstrate that alcohol consumption may increase alveolar bone loss in female rats in a dosedependent manner.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

to compare the 10-year marginal bone loss rates around implants supporting single-unit crowns in tobacco smokers with and without a history of treated periodontitis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: To compare the 10-year peri-implant bone loss (BL) rate in periodontally compromised (PCP) and periodontally healthy patients (PHP) around two different implant systems supporting single-unit crowns. MATERIALS AND METHODS: In this retrospective, controlled study, the mean BL (mBL) rate around dental implants placed in four groups of 20 non-smokers was evaluated after a follow-up of 10 years. Two groups of patients treated for periodontitis (PCP) and two groups of PHP were created. For each category (PCP and PHP), two different types of implant had been selected. The mBL was calculated by subtracting the radiographic bone levels at the time of crown cementation from the bone levels at the 10-year follow-up. RESULTS: The mean age, mean full-mouth plaque and full-mouth bleeding scores and implant location were similar between the four groups. Implant survival rates ranged between 85% and 95%, without statistically significant differences (P>0.05) between groups. For both implant systems, PCP showed statistically significantly higher mBL rates and number of sites with BL> or =3 mm compared with PHP (P<0.0001). CONCLUSIONS: After 10 years, implants in PCP yielded lower survival rates and higher mean marginal BL rates compared with those of implants placed in PHP. These results were independent of the implant system used or the healing modality applied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study summarizes the long-term clinical observations of edentulous patients treated with mandibular implant-supported overdentures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The use of endosseous dental implants has become common practice for the rehabilitation of edentulous patients, and a two-implant overdenture has been recommended as the standard of care. The use of small-diameter implants may extend treatment options and reduce the necessity for bone augmentation. However, the mechanical strength of titanium is limited, so titanium alloys with greater tensile and fatigue strength may be preferable. Purpose: This randomized, controlled, double-blind, multicenter study investigated in a split-mouth model whether small-diameter implants made from Titanium-13Zirconium alloy (TiZr, Roxolid™) perform at least as well as Titanium Grade IV implants. Methods and Materials: Patients with an edentulous mandible received one TiZr and one Ti Grade IV small-diameter bone level implant (3.3 mm, SLActive®) in the interforaminal region. The site distribution was randomized and double-blinded. Outcome measures included change in radiological peri-implant bone level from surgery to 12 months post-insertion (primary), implant survival, success, soft tissue conditions, and safety (secondary). Results: Of 91 treated patients, 87 were available for the 12-month follow-up. Peri-implant bone level change (-0.3 ± 0.5 mm vs -0.3 ± 0.6 mm), plaque, and sulcus bleeding indices were not significantly different between TiZr and Ti Grade IV implants. Implant survival rates were 98.9 percent and 97.8 percent, success rates were 96.6 percent and 94.4 percent, respectively. Nineteen minor and no serious adverse events were related to the study devices. Conclusion: This study confirms that TiZr small-diameter bone level implants provide at least the same outcomes after 12 months as Ti Grade IV bone level implants. The improved mechanical properties of TiZr implants may extend implant therapy to more challenging clinical situations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The concept of platform switching has been introduced to implant dentistry based on clinical observations of reduced peri-implant crestal bone loss. However, published data are controversial, and most studies are limited to 12 months. The aim of the present randomized clinical trial was to test the hypothesis that platform switching has a positive impact on crestal bone-level changes after 3 years. Two implants with a diameter of 4 mm were inserted crestally in the posterior mandible of 25 patients. The intraindividual allocation of platform switching (3.3-mm platform) and the standard implant (4-mm platform) was randomized. After 3 months of submerged healing, single-tooth crowns were cemented. Patients were followed up at short intervals for monitoring of healing and oral hygiene. Statistical analysis for the influence of time and platform type on bone levels employed the Brunner-Langer model. At 3 years, the mean radiographic peri-implant bone loss was 0.69 ± 0.43 mm (platform switching) and 0.74 ± 0.57 mm (standard platform). The mean intraindividual difference was 0.05 ± 0.58 mm (95% confidence interval: -0.19, 0.29). Crestal bone-level alteration depended on time (p < .001) but not on platform type (p = .363). The present randomized clinical trial could not confirm the hypothesis of a reduced peri-implant crestal bone loss, when implants had been restored according to the concept of platform switching.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE This retrospective observational pilot study examined differences in peri-implant bone level changes (ΔIBL) between two similar implant types differing only in the surface texture of the neck. The hypothesis tested was that ΔIBL would be greater with machined-neck implants than with groovedneck implants. METHOD AND MATERIALS 40 patients were enrolled; n = 20 implants with machined (group 1) and n = 20 implants with a rough, grooved neck (group 2), all placed in the posterior mandible. Radiographs were obtained after loading (at 3 to 9 months) and at 12 to 18 months after implant insertion. Case number calculation with respect to ΔIBL was conducted. Groups were compared using a Brunner-Langer model, the Mann-Whitney test, the Wilcoxon signed rank test, and linear model analysis. RESULTS After the 12- to 18-month observation period, mean ΔIBL was -1.11 ± 0.92 mm in group 1 and -1.25 ± 1.23 mm in group 2. ΔIBL depended significantly on time (P < .001), but not on group. In both groups, mean marginal ΔIBL was significantly less than -1.5 mm. Only insertion depth had a significant influence on the amount of periimplant bone loss (P = .013). Case number estimate testing for a difference between group 1 and 2 with a power of 90% revealed a sample size per group of 1,032 subjects. CONCLUSION ΔIBL values indicated that both implant designs fulfilled implant success criteria, and the modification of implant neck texture had no significant influence on ΔIBL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To evaluate and compare crestal bone level changes and peri-implant status of implant-supported reconstructions in edentulous and partially dentate patients after a minimum of 5 years of loading. MATERIALS AND METHODS All patients who received a self-tapping implant with a microstructured surface during the years 2003 and 2004 at the Department of Prosthodontics, University of Bern, were included in this study. The implant restorations comprised fixed and removable prostheses for partially and completely edentulous patients. Radiographs were taken immediately after surgery, at impression making, and 1 and 5 years after loading. Crestal bone level (BIC) was measured from the implant shoulder to the first bone contact, and changes were calculated over time (ΔBIC). The associations between pocket depth, bleeding on probing (BOP), and ΔBIC were assessed. RESULTS Sixty-one implants were placed in 20 patients (mean age, 62 ± 7 years). At the 5-year follow-up, 19 patients with 58 implants were available. Implant survival was 98.4% (one early failure; one patient died). The average ΔBIC between surgery and 5-year follow-up was 1.5 ± 0.9 mm and 1.1 ± 0.6 mm for edentulous and partially dentate patients, respectively. Most bone resorption (50%, 0.7 mm) occurred during the first 3 months (osseointegration) and within the first year of loading (21%, 0.3 mm). Mean annual bone loss during the 5 years of loading was < 0.12 mm. Mean pocket depth was 2.6 ± 0.7 mm. Seventeen percent of the implant sites displayed BOP; the frequency was significantly higher in women. None of the variables were significantly associated with crestal bone loss. CONCLUSION Crestal bone loss after 5 years was within the normal range, without a significant difference between edentulous and partially dentate patients. In the short term, this implant system can be used successfully for various prosthetic indications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose.This retrospective cohort study evaluated factors for peri-implant bone level changes (ΔIBL) associated with an implant type with inner-cone implant-abutment connection, rough neck surface, and platform switching (AT). Materials and Methods. All AT placed at the Department of Prosthodontics of the University of Bern between January 2004 and December 2005 were included in this study. All implants were examined by single radiographs using the parallel technique taken at surgery (T0) and obtained at least 6 months after surgery (T1). Possible influencing factors were analysed first using t-test (normal distribution) or the nonparametric Wilcoxon test (not normal distribution), and then a mixed model q variance analysis was performed. Results. 43 patients were treated with 109 implants. Five implants in 2 patients failed (survival rate: 95.4%).Mean ΔIBL in group 1 (T1: 6–12 months after surgery) was −0.65 ± 0.82mm and −0.69 ± 0.82mm in group 2 (T1: >12 months after surgery) (

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE The aim of this investigation was to evaluate the performance of Straumann Bone Level SLActive implants in various clinical situations in daily dental practice for up to 3 years. METHOD AND MATERIALS This was a prospective, multicenter, non-interventional study in which implants were placed within approved indications in any situation deemed suitable by the treating clinician. No implant placement or loading protocol was specified, and implants were placed according to the routine treatment protocols at each participating center. RESULTS In this analysis, data were available from 342 implants in 233 patients in three countries (USA, Canada, and Switzerland). One or two implants were placed in the majority of patients (70.8% and 19.3%, respectively), mostly in the maxilla (71.3%); almost half (47.7%) were placed in the esthetic zone. Implant placement after 4 to > 16 weeks of healing was preferred in Switzerland (92.0%), while 42.0% of implants were placed immediately in the USA and Canada. A flapless procedure was performed in 25.2% of cases in the USA and Canada, compared to 0.5% in Switzerland. Cumulative implant survival and success rates after 3 years were 97.5% and 93.5%, respectively. CONCLUSION Straumann Bone Level Implants can achieve favorable outcomes and high survival rates after 3 years in daily dental practice. The survival and success rates were comparable with those achieved in formal controlled clinical trials.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: This study evaluated the influence of distal extension removable partial denture associated with implant in cases of different bone level of abutment tooth, using 2D finite element analysis.Materials and Methods: Eight hemiarch models were simulated: model A-presenting tooth 33 and distal extension removable partial denture replacing others teeth, using distal rest connection and no bone lost; model B-similar to model A but presenting distal guide plate connection; model C-similar to model A but presenting osseointegrated implant with ERA retention system associated under prosthetic base; model D-similar to model B but presenting osseointegrated implant as described in model C; models E, F, G, and H were similar to models A, B, C, and D but presenting reduced periodontal support around tooth 33. Using ANSYS 9.0 software, the models were loaded vertically with 50 N on each cusp tip. For results, von Mises Stress Maps were plotted.Results: Maximum stress value was encountered in model G (201.023 MPa). Stress distribution was concentrated on implant and retention system. The implant/removable partial denture association decreases stress levels on alveolar mucosa for all models.Conclusions: Use of implant and ERA system decreased stress concentrations on supporting structures in all models. Use of distal guide plate decreased stress levels on abutment tooth and cortical and trabecular bone. Tooth apex of models with reduced periodontal support presented increased stress when using distal rest. (Implant Dent 2011;20:192-201)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A role for gut hormone in bone physiology has been suspected. We evidenced alterations of microstructural morphology (trabecular and cortical) and bone strength (both at the whole-bone - and tissue-level) in double incretin receptor knock-out (DIRKO) mice as compared to wild-type littermates. These results support a role for gut hormones in bone physiology. INTRODUCTION: The two incretins, glucose-dependent insulinotropic polypeptide (GIP) and glucagon-like peptide-1 (GLP-1), have been shown to control bone remodeling and strength. However, lessons from single incretin receptor knock-out mice highlighted a compensatory mechanism induced by elevated sensitivity to the other gut hormone. As such, it is unclear whether the bone alterations observed in GIP or GLP-1 receptor deficient animals resulted from the lack of a functional gut hormone receptor, or by higher sensitivity for the other gut hormone. The aims of the present study were to investigate the bone microstructural morphology, as well as bone tissue properties, in double incretin receptor knock-out (DIRKO) mice. METHODS: Twenty-six-week-old DIRKO mice were age- and sex-matched with wild-type (WT) littermates. Bone microstructural morphology was assessed at the femur by microCT and quantitative X-ray imaging, while tissue properties were investigated by quantitative backscattered electron imaging and Fourier-transformed infrared microscopy. Bone mechanical response was assessed at the whole-bone- and tissue-level by 3-point bending and nanoindentation, respectively. RESULTS: As compared to WT animals, DIRKO mice presented significant augmentations in trabecular bone mass and trabecular number whereas bone outer diameter, cortical thickness, and cortical area were reduced. At the whole-bone-level, yield stress, ultimate stress, and post-yield work to fracture were significantly reduced in DIRKO animals. At the tissue-level, only collagen maturity was reduced by 9 % in DIRKO mice leading to reductions in maximum load, hardness, and dissipated energy. CONCLUSIONS: This study demonstrated the critical role of gut hormones in controlling bone microstructural morphology and tissue properties.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objectives: The vertical location of the implant-abutment connection influences the periimplant bone morphology. It is unknown, however, whether different microgap configurations cause different bone reactions. Therefore, in this study the bone morphologies of two different implant systems were compared.Material and methods: Three months after tooth extraction in eight mongrel dogs, two grit-blasted screw implants with internal Morse taper connection (ANK group) were placed on one side whereas the contralateral side received two oxidized screw implants with external hex (TIU group). One implant on each side was placed level with the bone (equicrestal), the second implant was inserted 1.5mm below bone level (subcrestal). After 3 months the implants were uncovered. Three months after stage two surgery, histometrical evaluations were performed in order to assess the periimplant bone levels (PBL), the first bone-to-implant contact points (BICP), the width (HBD) and the steepness (SLO) of the bone defect.Results: All implants osseointegrated clinically and histologically. Bone overgrowth of the microgap was seen in ANK implants only. No significant differences between ANK and TIU could be detected in neither vertical position for PBL and BICP. However, a tendency in favor of ANK was visible when the implants were placed subcrestally. In the parameters HBD (ANK equicrestal -0.23mm; TIU equicrestal -0.51mm; ANK subcrestal +0.19mm; TIU subcrestal -0.57mm) and SLO (ANK equicrestal 35.36 degrees; TIU equicrestal 63.22 degrees; ANK subcrestal 20.40 degrees; TIU subcrestal 44.43 degrees) more pronounced and significant differences were noted.Conclusions: Within the limits of this study, it is concluded that different microgap designs cause different shapes and sizes of the periimplant ('dish-shaped') bone defect in submerged implants both in equicrestal and subcrestal positions.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: The vertical location of the implant-abutment connection influences the subsequent reaction of the peri-implant bone. It is not known, however, whether any additional influence is exerted by different microgap configurations. Therefore, the radiographic bone reactions of two different implant systems were monitored for 6 months. Materials and Methods: In eight mongrel dogs, two implants with an internal Morse-taper connection (INT group) were placed on one side of the mandible; the contralateral side received two implants with an external-hex connection (EXT group). on each side, one implant was aligned at the bone level (equicrestal) and the second implant was placed 1.5 mm subcrestal. Healing abutments were placed 3 months after submerged healing, and the implants were maintained for another 3 months without prosthetic loading. At implant placement and after 1, 2, 3, 4, 5, and 6 months, standardized radiographs were obtained, and peri-implant bone levels were measured with regard to microgap location and evaluated statistically. Results: All implants osseointegrated clinically and radiographically. The overall mean bone loss was 0.68 +/- 0.59 mm in the equicrestal INT group, 1.32 +/- 0.49 mm in the equicrestal EXT group, 0.76 +/- 0.49 mm in the subcrestal INT group, and 1.88 +/- 0.81 mm in the subcrestal EXT group. The differences between the INT and EXT groups were statistically significant (paired t tests). The first significant differences between the internal and external groups were seen at month 1 in the subcrestal groups and at 3 months in the equicrestal groups. Bone loss was most pronounced in the subcrestal EXT group. Conclusions: Within the limits of this study, different microgap configurations can cause different amounts of bone loss, even before prosthetic loading. Subcrestal placement of a butt-joint microgap design may lead to more pronounced radiographic bone loss. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:941-946