998 resultados para Boiling water
Resumo:
This Master´s thesis investigates the performance of the Olkiluoto 1 and 2 APROS model in case of fast transients. The thesis includes a general description of the Olkiluoto 1 and 2 nuclear power plants and of the most important safety systems. The theoretical background of the APROS code as well as the scope and the content of the Olkiluoto 1 and 2 APROS model are also described. The event sequences of the anticipated operation transients considered in the thesis are presented in detail as they will form the basis for the analysis of the APROS calculation results. The calculated fast operational transient situations comprise loss-of-load cases and two cases related to a inadvertent closure of one main steam isolation valve. As part of the thesis work, the inaccurate initial data values found in the original 1-D reactor core model were corrected. The input data needed for the creation of a more accurate 3-D core model were defined. The analysis of the APROS calculation results showed that while the main results were in good accordance with the measured plant data, also differences were detected. These differences were found to be caused by deficiencies and uncertainties related to the calculation model. According to the results the reactor core and the feedwater systems cause most of the differences between the calculated and measured values. Based on these findings, it will be possible to develop the APROS model further to make it a reliable and accurate tool for the analysis of the operational transients and possible plant modifications.
Resumo:
From the 60s to the 90s, a great number of events related to the Emergency Core Cooling Systems Strainers have been happened in all kind of reactors all over the world. Thus, the Nuclear Regulatory Commission of the USA emitted some Bulletins to address the concerns about the adequacy of Emergency Core Cooling Systems (ECCS) strainer performance at boiling water reactors (BWR). In Spain the regulatory body (Consejo de Seguridad Nuclear, CSN) adopted the USA regulation and Cofrentes NPP installed new strainers with a considerable bigger size than the old strainers. The nuclear industry conducted significant and extensive research, guidance development, testing, reviews, and hardware and procedure changes during the 90s to resolve the issues related to debris blockage of BWR strainers. In 2001 the NRC and CSN closed the Bulletins. Thereafter, the strainers issues were moved to the PWR reactors. In 2004 the NRC issued a Generic Letter (GL). It requested the resolution of several effects which were not noted in the past. The GL regarded to be resolved by the PWR reactors but the NRC in USA and the CSN in Spain have requested that the BWR reactors investigate differences between the methodologies used by the BWRs and PWRs. The developments and improvements done for Cofrentes NPP are detailed. Studies for this plant show that the head loss due to the considered debris is at most half of the limited head loss for the ECCS strainer and the NPSH (Net Positive Suction Head) required for the ECCS pumps is at least three times lower than the NPSH available.
Resumo:
"Reactor technology."
Resumo:
"June 1959."
Resumo:
"Prepared under Contract AT(04-3)-165 with the United States Atomic Energy Commission."
Resumo:
Cork boiling water is an aqueous and complex dark liquor with high concentration of phenolic compounds such as phenolic acids and tannins [1, 2], which are considered biorecalcitrants [2]. Ionizing radiation has been widely studied as an alternative technology for the degradation of organic contaminants without the addition of any other (e.g.: Fenton technologies). The aim of this work was to identify the compounds present in cork boiling water and further evaluate the resulting stable degradation products after gamma irradiation. The irradiation experiments of standard solutions were carried out at room temperature using a Co-60 experimental equipment. The applied absorbed doses were 20 and 50 kGy at a dose rate of 1.5 kGy/h, determined by routine dosimeters [3]. The identification of radiolytic products was carried out by HPLC-DAD-ESI/MS. The phenolic compounds were identified by comparing their retention times and UV–vis and mass spectra with those obtained from standard compounds, when available, as well as by comparing the obtained information with available data reported in the literature. Concerning the obtained results and the literature review, the main cork wastewater components are: quinic, gallic, protocatechuic, vanillic, syringic and ellagic acids. Based on this, we used protocatechuic, vanillic and syringic acids as model compounds to study their degradation by gamma radiation in order to identify the corresponding radiolytic products. Standard aqueous solutions were irradiated and the derivatives of each model compound are represented in figure 1. The obtained results seem to demonstrate that the derivatives of the parent compounds could also be phenolic acids, since it was observed the loss of 44 u (CO2) from the [M-H]- ions. Gallic and protocatechuic acids are identified as derivatives of vanillic and syringic acids, and gallic acid as a protocatechuic acid derivative. Compound 5 ([M-H]- at m/z 169) was tentatively identified as 2,4,6-trihydroxybenzoic acid, since its fragmentation pattern (m/z 151, 125 and 107) is similar to that previously reported in literature [4]. The structure of compound 7 was proposed based on the molecular ion and its fragmentation and compound 6 remains unknown.
Resumo:
Objective: Cooling is considered a panacea in burn injury. However, burn injuries are characterized by an ischemic zone prone to progression, a phenomenon that can substantially increase morbidity. Cold-induced vasoconstriction potentially aggravates ischemia and promotes progression. Therefore we compared the effect of warm (37°C) and cold (17°C) water on burn progression. Methods: The comb burn model creates 4 rectangular burned surfaces separated by 3 unburned interspaces that become necrotic if untreated. After heating in boiling water the template was applied for 60 seconds on 24 Wistar rats randomized into 3 groups: no treatment (CON); treatment for 20 minutes with cold water (17°C: CW) or warm water (37°C: WW). Burn progression in surface (planimetry) and Departmenth (histology), as well as microcirculatory perfusion (laser Doppler flowmetry) were assessed after 1h, as well as 1, 4, and 7 days. Results: Both CW and WW delayed burn progression without reducing the final burn Departmenth (deep dermis). In contrast, only WW but not CW increased dermal perfusion (81 ± 2% (WW) vs. 62 ± 2% (CW) and 63 ± 1% (CON), p< 0·05) already 1 hour after burn induction. The difference observed after one hour led to a complete flow recovery during the observation period and translated into increased interspace survival, respectively less necrosis with WW(65 ± 4% vs. 81 + 4% (CW) and 91 ± 2% (CON), p< 0·05) after 7 days. Conclusions: Application of warm water significantly improved dermal perfusion, increased interspace survival, and delayed burn progression.However it didn't alter the ultimate burn Departmenth of the actually burned area. Therefore, warm water can create a therapeutic window for targeted nonsurgical treatment of burn progression.
Resumo:
Diplomityö käsittelee kiehutusvesilaitosten transienttien ja onnettomuuksien analysointia APROS-ohjelmiston avulla. Työ on tehty Teollisuuden Voima Oy:n (TVO) Olkiluoto 1 ja 2 laitosyksiköiden mallin pohjalta. Raportissa esitetään ohjelmiston käyttämiä yhtälöitäja laskentamalleja yleisellä tasolla. Työssä esitellään laitoksen yleispiirteet turvallisuustoimintoineen ja kuvataan ohjelmaan suureksi osaksi aiemmin luotua laskentamallia. Työssä on luetteloitu voimassa olevatlisensiointianalyysit, joiden joukosta on valittu laskentatapauksia ohjelmiston suorituskyvyn arviointia varten. Lisäksi työhön on valittu laskentatapauksia muilla kuin lisensointiin käytetyillä ohjelmilla lasketuista analyyseistä. Lisäksi on suoritettu vertailulaskuja konservatiivisen ja realistisen mallin erojen esille saamiseksi. Laskentatapauksia ovat mm. ylipainetransientti, jäähdytteen menetysonnettomuus ja oletettavissa oleva käyttöhäiriö, jossa pikasulku ei toimi (ATWS). Diplomityön edetessä laitosmallia on kehitetty edelleen lisäämällä joitakin järjestelmiä ja tarkentamalla joidenkin komponenttien kuvausta. Työssä ilmeni, että APROS soveltuu jäähdytteenmenetysonnettomuuden ja suojarakennuksen yhtäaikaiseen analyysiin. APROS.n vaste nopeisiin transientteihin jäi kuitenkin vertailutasosta. Tämän työn perusteella APROS-mallia kehitys jatkuu edelleen siten, että se soveltuisi entistä paremmin myös nopeiden transienttien ja ATWS-tilanteiden kuvaamiseen. Työssä olevaa lisensointianalyysien kuvausta tullaan käyttämään hyväksi selvitettäessä laitoksen turvallisuuden väliarviossa tarvittavien analyysien määrää ja laatua. Nyt saatuja kokemuksia voidaan hyödyntää myös mahdollisen kolmiulotteisen sydänmallin hankinnassa APROS-ohjelmistoon. Tässä diplomityössä esitettyjä parannuksia voidaan käyttää hyväksi SAFIRtutkimusohjelman hankkeiden suunnittelussa.
Resumo:
The epoxide ring in 5,6-dihydro-5,6-epoxy-1,10-phenanthroline (L) opens up in its reaction with 4-methylaniline and 4-methoxyaniline in water in equimolar proportion at room temperature without any Lewis acid catalyst to give a monohydrate of 6-(4-methyl-phenylamino)-5,6-dihydro-1,10-phenanthrolin-5-ol (L′·H2O) and 6-(4-methoxyphenyl-amino)-5,6-dihydro-1,10-phenanthrolin-5-ol (L″) respectively. Reaction time decreases from 72 to 14 h in boiling water. But the yields become less. Reaction of L with Zn(ClO4)2·6H2O in methanol in 3:1 molar ratio at room temperature affords white [ZnL3](ClO4)2·H2O. The X-ray crystal structure of the acetonitrile solvate [ZnL3](ClO4)2·MeCN has been determined which shows that the metal has a distorted octahedral N6 coordination sphere. [ZnL3](ClO4)2·2H2O reacts with 4-methylaniline and 4-methoxyaniline in boiling water in 1:3 molar proportion in the absence of any Lewis acid catalyst to produce [ZnL′3](ClO4)2·4H2O and [ZnL″3](ClO4)2·H2O, respectively in 1–4 h time in somewhat low yield. In the 1H NMR spectra of [ZnL′3](ClO4)2·4H2O and [ZnL″3](ClO4)2·H2O, only one sharp methyl signal is observed implicating that only one diastereomer out of the 23 possibilities is formed. The same diastereomers are obtained when L′·H2O and L″ are reacted directly with Zn(ClO4)2·6H2O in tetrahydrofuran at room temperature in very good yields. Reactions of L′·H2O and L″ with Ru(phen)2Cl2·2H2O (phen = 1,10-phenanthroline) in equimolar proportion in methanol–water mixture under refluxing condition lead to the isolation of two diastereomers of [Ru(phen)2L′](ClO4)2·2H2O and [Ru(phen)2L″](ClO4)2·2H2O.
Resumo:
The need to refine models for best-estimate calculations, based on good-quality experimental data, has been expressed in many recent meetings in the field of nuclear applications. The modeling needs arising in this respect should not be limited to the currently available macroscopic methods but should be extended to next-generation analysis techniques that focus on more microscopic processes. One of the most valuable databases identified for the thermalhydraulics modeling was developed by the Nuclear Power Engineering Corporation (NUPEC), Japan. From 1987 to 1995, NUPEC performed steady-state and transient critical power and departure from nucleate boiling (DNB) test series based on the equivalent full-size mock-ups. Considering the reliability not only of the measured data, but also other relevant parameters such as the system pressure, inlet sub-cooling and rod surface temperature, these test series supplied the first substantial database for the development of truly mechanistic and consistent models for boiling transition and critical heat flux. Over the last few years the Pennsylvania State University (PSU) under the sponsorship of the U.S. Nuclear Regulatory Commission (NRC) has prepared, organized, conducted and summarized the OECD/NRC Full-size Fine-mesh Bundle Tests (BFBT) Benchmark. The international benchmark activities have been conducted in cooperation with the Nuclear Energy Agency/Organization for Economic Co-operation and Development (NEA/OECD) and Japan Nuclear Energy Safety (JNES) organization, Japan. Consequently, the JNES has made available the Boiling Water Reactor (BWR) NUPEC database for the purposes of the benchmark. Based on the success of the OECD/NRC BFBT benchmark the JNES has decided to release also the data based on the NUPEC Pressurized Water Reactor (PWR) subchannel and bundle tests for another follow-up international benchmark entitled OECD/NRC PWR Subchannel and Bundle Tests (PSBT) benchmark. This paper presents an application of the joint Penn State University/Technical University of Madrid (UPM) version of the well-known subchannel code COBRA-TF, namely CTF, to the critical power and departure from nucleate boiling (DNB) exercises of the OECD/NRC BFBT and PSBT benchmarks
Resumo:
"May 1, 1962."
Resumo:
"PWRA-GNEC Report No. 1."
Resumo:
"January 28, 1960."