963 resultados para Body surface
Resumo:
Computed tomography (CT) is used increasingly to measure liver volume in patients undergoing evaluation for transplantation or resection. This study is designed to determine a formula predicting total liver volume (TLV) based on body surface area (BSA) or body weight in Western adults. TLV was measured in 292 patients from four Western centers. Liver volumes were calculated from helical computed tomographic scans obtained for conditions unrelated to the hepatobiliary system. BSA was calculated based on height and weight. Each center used a different established method of three-dimensional volume reconstruction. Using regression analysis, measurements were compared, and formulas correlating BSA or body weight to TLV were established. A linear regression formula to estimate TLV based on BSA was obtained: TLV = -794.41 + 1,267.28 x BSA (square meters; r(2) = 0.46; P <.0001). A formula based on patient weight also was derived: TLV = 191.80 + 18.51 x weight (kilograms; r(2) = 0.49; P <.0001). The newly derived TLV formula based on BSA was compared with previously reported formulas. The application of a formula obtained from healthy Japanese individuals underestimated TLV. Two formulas derived from autopsy data for Western populations were similar to the newly derived BSA formula, with a slight overestimation of TLV. In conclusion, hepatic three-dimensional volume reconstruction based on helical CT predicts TLV based on BSA or body weight. The new formulas derived from this correlation should contribute to the estimation of TLV before liver transplantation or major hepatic resection.
Resumo:
Previous research has provided inconsistent results regarding the spatial modulation of auditory-somatosensory interactions. The present study reports three experiments designed to investigate the nature of these interactions in the space close to the head. Human participants made speeded detection responses to unimodal auditory, somatosensory, or simultaneous auditory-somatosensory stimuli. In Experiment 1, electrocutaneous stimuli were presented to either earlobe, while auditory stimuli were presented from the same versus opposite sides, and from one of two distances (20 vs. 70cm) from the participant's head. The results demonstrated a spatial modulation of auditory-somatosensory interactions when auditory stimuli were presented from close to the head. In Experiment 2, electrocutaneous stimuli were delivered to the hands, which were placed either close to or far from the head, while the auditory stimuli were again presented at one of two distances. The results revealed that the spatial modulation observed in Experiment 1 was specific to the particular body part stimulated (head) rather than to the region of space (i.e. around the head) where the stimuli were presented. The results of Experiment 3 demonstrate that sounds that contain high-frequency components are particularly effective in eliciting this auditory-somatosensory spatial effect. Taken together, these findings help to resolve inconsistencies in the previous literature and suggest that auditory-somatosensory multisensory integration is modulated by the stimulated body surface and acoustic spectra of the stimuli presented.
Resumo:
BACKGROUND: Limited data have been published on the normal size of the ascending aorta (AA) measured using transthoracic echocardiography (TTE). METHODS: AA diameters were measured in 1799 patients with normal cardiac findings on TTE and compared with the diameters of the sinus of Valsalva (SoV). RESULTS: Mean diameters in men and women, respectively, were 3.4 and 3.1 cm for the SoV and 3.2 and 3.0 cm for the AA. The sizes of the SoV and the AA showed strong correlations with age, age squared, and body surface area. The 5th and 95th percentile curves for the SoV and AA showed faster growth of diameters in early adulthood compared with old age. The dimensions of the SoV were larger than those of the AA (mean differences, 0.19 cm in men and 0.08 cm in women), and the difference between the SoV and AA was negatively correlated with age. CONCLUSION: The findings of this study stress the importance of indexing dimensions of the SoV and the AA to age and body surface area separately for men and women.
Resumo:
Purpose: Obesity is an established independent risk factor for chronic kidney disease. Thus, measurement of glomerular filtration rate (GFR) is important in this population. Traditionally, GFR has been indexed for body surface area (BSA), but this indexation may not be appropriate in obese individuals. Therefore, the objective of the study was to compare absolute GFR with GFR indexed for BSA and with GFR indexed for height. Methods and materials: The study was conducted in 66 families from the Seychelles islands that included several members with hypertension. GFR and effective renal plasma flow (ERPF) were measured using inulin and PAH clearances, respectively. Antihypertensive treatment, if used, was withheld 2 weeks before conducting the clearances. Participants with diabetes mellitus were excluded from the analysis. BSA was calculated using the Dubois formula. We assessed trend across BMI categories using a non parametric test. Results: Participants included 174 women and 127 men. The prevalence of hypertension was 61%, of which 68% were treated. The table shows that absolute GFR, GFR indexed for height, ERPF, filtration fraction were significantly higher across BMI categories. When GFR was indexed for BSA, the association between GFR and BMI categories was lost. Conclusion: Indexing GFR for BSA in overweight and obese individuals leads to a substantial underestimation of GFR. Filtration fraction, which does not depend on BSA, is higher in obese individuals, which suggests glomerular hyperfiltration. Indexing GFR for BSA therefore would mask the underlying glomerular hyperfiltration. As the number of nephrons does not increase with weight gain, absolute GFR represents a better marker of single nephron GFR and is more appropriate.
Resumo:
Increasing air movement over poultry by using fans (ventilation) has become an accepted means of reducing environmental heat stress over the last several years. The purpose of this study was to evaluate the effect of air velocity and exposure time to ventilation on body surface and rectal temperature of broiler chickens. Male broiler chickens aged 36-42 days were placed in individual wire cages and exposed to five different air velocities (5.7, 4.2, 3.1, 2.4, or 1.8 m/sec). Throughout the experiment head, back, leg, and rectal temperatures were monitored every 10 min during a 30-min period for each air velocity. The data showed that exposure time to the wind affected (P<.05) leg and body temperature, with a rapid reduction being observed during the first 10 min. There was a reduction in leg temperature with air velocity of 2 m/sec; however, air velocity lower than 4.5 m/sec was not effective in decreasing head and back temperature. The results suggest that air velocity of 2 m/sec, in air temperature of 29 degrees C, improves heat loss in the birds. The data also indicate that exposure time to ventilation seems to be a critical point in the maintenance of bird thermal homeostasis.
Resumo:
A transferência de energia térmica da superfície corporal para a água é provavelmente o aspecto mais importante do equilíbrio térmico em mamíferos marinhos, mas os respectivos cálculos dependem do conhecimento da temperatura da superfície, T S, cuja medição direta em animais em liberdade constitui um problema difícil de resolver. Um método iterativo é proposto para a predição de T S de cetáceos em liberdade, a partir da temperatura corporal profunda, da velocidade de deslocamento e da temperatura e propriedades termodinâmicas da água.
Resumo:
The general principles of the mechanisms of heat transfer are well known, but knowledge of the transition between evaporative and non-evaporative heat loss by Holstein cows in field conditions must be improved, especially for low-latitude environments. With this aim 15 Holstein cows managed in open pasture were observed in a tropical region. The latent heat loss from the body surface of the animals was measured by means of a ventilated capsule, while convective heat transfer was estimated by the theory of convection from a horizontal cylinder and by the long-wave radiation exchange based on the Stefan-Boltzmann law. When the air temperature was between 10 and 36 degrees C the sensible heat transfer varied from 160 to -30 W m(-2), while the latent heat loss by cutaneous evaporation increased from 30 to 350 W m(-2). Heat loss by cutaneous evaporation accounted for 20-30% of the total heat loss when air temperatures ranged from 10 to 20 degrees C. At air temperatures > 30 degrees C cutaneous evaporation becomes the main avenue of heat loss, accounting for approximately 85% of the total heat loss, while the rest is lost by respiratory evaporation.
Resumo:
Peak flow rate data (Q(max)) are important for diagnosis of lower urinary tract obstruction. However, the lack of uroflowmetry studies in children, makes their interpretation difficult. With this aim, we studied 167 boys classified in four groups according to their age (G1 : n = 48, 6-7 years; G2 : n = 43, 8-9 years; G3 : n = 37, 10-11 years; G4: n = 39, 12-14 years). We studied in all children, weight, height, body surface area, peak flow rate (Q(max) and the correspondant urinary volume (Vol). Means and standard deviations of Q(max) (ml/sec) were : 15 +/- 5 (G1), 15 +/- 5 (G2), 17 +/- 5 (G3) and 22 +/- 7 (G4) respectively. Corresponding urinary volumes (Vol) (mean standard deviation - in ml) were : G1 = 123 +/- 75; G2 = 122 +/- 79; G3 = 158 +/- 96 and G4 = 162 +/- 101. We found a significant correlation (p < 0,01) between Q(max) and Vol in groups G2, G3 and G4; and between Q(max) and height in groups G1 and G4.The authors demonstrated a positive correlation between maximum flow and voided volume, and an increase of Q(max) with age.
Resumo:
Peak flow rate data (Qmax) are important for diagnosis of lower urinary tract obstruction. However, the lack of uroflowmetry studies in children, makes their interpretation difficult. With this aim, we studied 167 boys classified in four groups according to their age (G1: n = 48, 6-7 years; G2: n = 43, 8-9 years; G3: n = 37, 10-11 years; G4: n = 39, 12-14 years). We studied in all children, weight, height, body surface area, peak flow rate (Qmax) and the correspondant urinary volume (Vol). Means and standard deviations of Qmax (ml/sec) were: 15 +/- 5 (G1), 15 +/- 5 (G2), 17 +/- 5 (G3) and 22 +/- 7 (G4) respectively. Corresponding urinary volumes (Vol) (mean standard deviation-in ml) were: G1 = 123 +/- 75; G2 = 122 +/- 79; G3 = 158 +/- 96 and G4 = 162 +/- 101. We found a significant correlation (p < 0,01) between Qmax and Vol in groups G2, G3 and G4; and between Qmax and height in groups G1 and G4. The authors demonstrated a positive correlation between maximum flow and voided volume, and an increase of Qmax with age.
Resumo:
Background: The controversial effects promoted by cardiac resynchronization therapy (CRT) on the ventricular repolarization (VR) have motivated VR evaluation by body surface potential mapping (BSPM) in CRT patients. Methods: Fifty-two CRT patients, mean age 58.8 +/- 12.3 years, 31 male, LVEF 27.5 +/- 9.2, NYHA III-IV heart failure with QRS181.5 +/- 14.2 ms, underwent 87-lead BSPM in sinus rhythm (BASELINE) and biventricular pacing (BIV). Measurements of mean and corrected QT intervals and dispersion, mean and corrected T peak end intervals and their dispersion, and JT intervals characterized global and regional (RV, Intermediate, and LV regions) ventricular repolarization response. Results: Global QTm (P < 0.001) and QTcm (P < 0.05) were decreased in BIV; QTm was similar across regions in both modes (P = ns); QTcm values were lower in RV/LV than in Intermediate region in BASELINE and BIV (P < 0.001); only RV/Septum showed a significant difference (P < 0.01) in the BIV mode. QTD values both of BASELINE (P < 0.01) and BIV (P < 0.001) were greater in the Intermediate than in the LV region. CRT effect significantly reduced global/regional QTm and QTcm values. QTD was globally decreased in RV/LV (Intermediate: P = ns). BIV mode significantly reduced global T peak end mean and corrected intervals and their dispersion. JT values were not significant. Conclusions: Ventricular repolarization parameters QTm, QTcm, and QTD global/regional values, as assessed by BSPM, were reduced in patients under CRT with severe HF and LBBB. Greater recovery impairment in the Intermediate region was detected by the smaller variation of its dispersion.
Resumo:
Until today, most of the documentation of forensic relevant medical findings is limited to traditional 2D photography, 2D conventional radiographs, sketches and verbal description. There are still some limitations of the classic documentation in forensic science especially if a 3D documentation is necessary. The goal of this paper is to demonstrate new 3D real data based geo-metric technology approaches. This paper present approaches to a 3D geo-metric documentation of injuries on the body surface and internal injuries in the living and deceased cases. Using modern imaging methods such as photogrammetry, optical surface and radiological CT/MRI scanning in combination it could be demonstrated that a real, full 3D data based individual documentation of the body surface and internal structures is possible in a non-invasive and non-destructive manner. Using the data merging/fusing and animation possibilities, it is possible to answer reconstructive questions of the dynamic development of patterned injuries (morphologic imprints) and to evaluate the possibility, that they are matchable or linkable to suspected injury-causing instruments. For the first time, to our knowledge, the method of optical and radiological 3D scanning was used to document the forensic relevant injuries of human body in combination with vehicle damages. By this complementary documentation approach, individual forensic real data based analysis and animation were possible linking body injuries to vehicle deformations or damages. These data allow conclusions to be drawn for automobile accident research, optimization of vehicle safety (pedestrian and passenger) and for further development of crash dummies. Real 3D data based documentation opens a new horizon for scientific reconstruction and animation by bringing added value and a real quality improvement in forensic science.
Resumo:
In pediatric echocardiography, cardiac dimensions are often normalized for weight, height, or body surface area (BSA). The combined influence of height and weight on cardiac size is complex and likely varies with age. We hypothesized that increasing weight for height, as represented by body mass index (BMI) adjusted for age, is poorly accounted for in Z scores normalized for weight, height, or BSA. We aimed to evaluate whether a bias related to BMI was introduced when proximal aorta diameter Z scores are derived from bivariate models (only one normalizing variable), and whether such a bias was reduced when multivariable models are used. We analyzed 1,422 echocardiograms read as normal in children ≤18 years. We computed Z scores of the proximal aorta using allometric, polynomial, and multivariable models with four body size variables. We then assessed the level of residual association of Z scores and BMI adjusted for age and sex. In children ≥6 years, we found a significant residual linear association with BMI-for-age and Z scores for most regression models. Only a multivariable model including weight and height as independent predictors produced a Z score free of linear association with BMI. We concluded that a bias related to BMI was present in Z scores of proximal aorta diameter when normalization was done using bivariate models, regardless of the regression model or the normalizing variable. The use of multivariable models with weight and height as independent predictors should be explored to reduce this potential pitfall when pediatric echocardiography reference values are evaluated.
Resumo:
BACKGROUND & AIMS: The standard liver volume (SLV) is widely used in liver surgery, especially for living donor liver transplantation (LDLT). All the reported formulas for SLV use body surface area or body weight, which can be influenced strongly by the general condition of the patient. METHODS: We analyzed the liver volumes of 180 Japanese donor candidates and 160 Swiss patients with normal livers to develop a new formula. The dataset was randomly divided into two subsets, the test and validation sample, stratified by race. The new formula was validated using 50 LDLT recipients. RESULTS: Without using body weight-related variables, age, thoracic width measured using computed tomography, and race independently predicted the total liver volume (TLV). A new formula: 203.3-(3.61×age)+(58.7×thoracic width)-(463.7×race [1=Asian, 0=Caucasian]), most accurately predicted the TLV in the validation dataset as compared with any other formulas. The graft volume for LDLT was correlated with the postoperative prothrombin time, and the graft volume/SLV ratio calculated using the new formula was significantly better correlated with the postoperative prothrombin time than the graft volume/SLV ratio calculated using the other formulas or the graft volume/body weight ratio. CONCLUSIONS: The new formula derived using the age, thoracic width and race predicted both the TLV in the healthy patient group and the SLV in LDLT recipients more accurately than any other previously reported formulas.
Resumo:
ABSTRACT In animal farming, an automatic and precise control of environmental conditions needs information from variables derived from the animals themselves, i.e. they act as biosensors. Rectal temperature (RT) and respiratory rate (RR) are good indicators of thermoregulation in pigs. Since there is a growing concern on animal welfare, the search for alternatives to measure RT has become even more necessary. This research aimed to identify the most adequate body surface areas, on nursery-phase pigs, to take temperature measurements that best represent the correlation of RT and RR. The main experiment was carried out in a climate chamber with five 30-day-old littermate female Landrace x Large White piglets. Temperature conditions inside chamber were varied from 14 °C up to 35.5 °C. The measurements were taken each 30 minutes, over six different skin regions, using a temperature data logger Thermochron iButton® - DS1921G (Tb) and an infrared thermometer (Ti). As shown by the results, the tympanic region is the best one for RT and RR monitoring using an infrared thermometer (TiF). In contrast, when using temperature sensors, the ear (TbE) is preferred to be used for RT predictions and the loin region (TbC) for RR.
Resumo:
Perception of our own bodies is based on integration of visual and tactile inputs, notably by neurons in the brain’s parietal lobes. Here we report a behavioural consequence of this integration process. Simply viewing the arm can speed up reactions to an invisible tactile stimulus on the arm. We observed this visual enhancement effect only when a tactile task required spatial computation within a topographic map of the body surface and the judgements made were close to the limits of performance. This effect of viewing the body surface was absent or reversed in tasks that either did not require a spatial computation or in which judgements were well above performance limits. We consider possible mechanisms by which vision may influence tactile processing.