999 resultados para Body camera


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mobile technologies have brought about major changes in police equipment and police work. If a utopian narrative remains strongly linked to the adoption of new technologies, often formulated as 'magic bullets' to real occupational problems, there are important tensions between their 'imagined' outcomes and the (unexpected) effects that accompany their daily 'practical' use by police officers. This article offers an analysis of police officers' perceptions and interactions with security devices. In so doing, it develops a conceptual typology of strategies for coping with new technology inspired by Le Bourhis and Lascoumes: challenging, neutralizing and diverting. To that purpose, we adopt an ethnographic approach that focuses on the discourses, practices and actions of police officers in relation to three security devices: the mobile digital terminal, the mobile phone and the body camera. Based on a case study of a North American municipal police department, the article addresses how these technological devices are perceived and experienced by police officers on the beat.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Whole-body (WB) planar imaging has long been one of the staple methods of dosimetry, and its quantification has been formalized by the MIRD Committee in pamphlet no 16. One of the issues not specifically addressed in the formalism occurs when the count rates reaching the detector are sufficiently high to result in camera count saturation. Camera dead-time effects have been extensively studied, but all of the developed correction methods assume static acquisitions. However, during WB planar (sweep) imaging, a variable amount of imaged activity exists in the detector's field of view as a function of time and therefore the camera saturation is time dependent. A new time-dependent algorithm was developed to correct for dead-time effects during WB planar acquisitions that accounts for relative motion between detector heads and imaged object. Static camera dead-time parameters were acquired by imaging decaying activity in a phantom and obtaining a saturation curve. Using these parameters, an iterative algorithm akin to Newton's method was developed, which takes into account the variable count rate seen by the detector as a function of time. The algorithm was tested on simulated data as well as on a whole-body scan of high activity Samarium-153 in an ellipsoid phantom. A complete set of parameters from unsaturated phantom data necessary for count rate to activity conversion was also obtained, including build-up and attenuation coefficients, in order to convert corrected count rate values to activity. The algorithm proved successful in accounting for motion- and time-dependent saturation effects in both the simulated and measured data and converged to any desired degree of precision. The clearance half-life calculated from the ellipsoid phantom data was calculated to be 45.1 h after dead-time correction and 51.4 h with no correction; the physical decay half-life of Samarium-153 is 46.3 h. Accurate WB planar dosimetry of high activities relies on successfully compensating for camera saturation which takes into account the variable activity in the field of view, i.e. time-dependent dead-time effects. The algorithm presented here accomplishes this task.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of screening techniques, such as an alternative light source (ALS), is important for finding biological evidence at a crime scene. The objective of this study was to evaluate whether biological fluid (blood, semen, saliva, and urine) deposited on different surfaces changes as a function of the age of the sample. Stains were illuminated with a Megamaxx™ ALS System and photographed with a Canon EOS Utility™ camera. Adobe Photoshop™ was utilized to prepare photographs for analysis, and then ImageJ™ was used to record the brightness values of pixels in the images. Data were submitted to analysis of variance using a generalized linear mixed model with two fixed effects (surface and fluid). Time was treated as a random effect (through repeated measures) with a first-order autoregressive covariance structure. Means of significant effects were compared by the Tukey test. The fluorescence of the analyzed biological material varied depending on the age of the sample. Fluorescence was lower when the samples were moist. Fluorescence remained constant when the sample was dry, up to the maximum period analyzed (60 days), independent of the substrate on which the fluid was deposited, showing the novelty of this study. Therefore, the forensic expert can detect biological fluids at the crime scene using an ALS even several days after a crime has occurred.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The stylistic strategies, in particular those concerning camera placement and movement, of The Shield (FX, 2002-08) seem to directly fit into an aesthetic tradition developed by US cop dramas like Hill Street Blues (NBC, 1981-87), Homicide: Life on the Street (NBC, 1993-99) and NYPD Blue (ABC, 1993-2005). In these precinct dramas, decisions concerning spatial arrangements of camera and performer foreground a desire to present and react to action while it is happening, and with a minimum of apparent construction. As Jonathan Bignell (2009) has argued, the intimacy and immediacy of this stylistic approach, which has at its core an attempt at a documentary-like realism, is important to the police drama as a genre, while also being tendencies that have been taken as specific characteristics of television more generally. I explore how The Shield develops this tradition of a reactive camera style in its strategy of shooting with two cameras rather than one, with specific attention to how this shapes the presentation of performance. Through a detailed examination of the relationship between performer and camera(s) the chapter considers the way the series establishes access to the fictional world, which is crucial to the manner of police investigation central to its drama, and the impact of this on how we engage with performance. The cameras’ placement appears to balance various impulses, including: the demands of attending to an ensemble cast, spontaneous performance style, and action that is physically dynamic and involving. In a series that makes stylistic decisions around presentation of the body on-screen deliberately close yet obstructive, involving yet fleeting, the chapter explores the affect of this on the watching experience.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Activities involving fauna monitoring are usually limited by the lack of resources; therefore, the choice of a proper and efficient methodology is fundamental to maximize the cost-benefit ratio. Both direct and indirect methods can be used to survey mammals, but the latter are preferred due to the difficulty to come in sight of and/or to capture the individuals, besides being cheaper. We compared the performance of two methods to survey medium and large-sized mammal: track plot recording and camera trapping, and their costs were assessed. At Jatai Ecological Station (S21 degrees 31`15 ``- W47 degrees 34`42 ``-Brazil) we installed ten camera traps along a dirt road directly in front of ten track plots, and monitored them for 10 days. We cleaned the plots, adjusted the cameras, and noted down the recorded species daily. Records taken by both methods showed they sample the local richness in different ways (Wilcoxon, T=231; p;;0.01). The track plot method performed better on registering individuals whereas camera trapping provided records which permitted more accurate species identification. The type of infra-red sensor camera used showed a strong bias towards individual body mass (R(2)=0.70; p=0.017), and the variable expenses of this method in a 10-day survey were estimated about 2.04 times higher compared to track plot method; however, in a long run camera trapping becomes cheaper than track plot recording. Concluding, track plot recording is good enough for quick surveys under a limited budget, and camera trapping is best for precise species identification and the investigation of species details, performing better for large animals. When used together, these methods can be complementary.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fat body cells of virgin females and queens of Pachycondyla striata ants belonging to the subfamily Ponerinae are illustrated from morphologic, ultramorphologic and morphometric viewpoints. Camera lucida drawing techniques were used, as well as scanning electronic microscopy (SEM). Measurements of trophocytes and oenocytes areas in the tissue were recorded. The results showed that in P. striata queens and virgin females the trophocytes are arranged in cord-like formations in association with oenocytes. Trophocytes of both castes had round shapes, with rather vacuolized cytoplasm, whereas oenocytes, being smaller than trophocytes, had more homogeneous cytoplasm. It was also observed that both trophocytes and oenocytes of virgin females were larger than those found in the same queen cellular types.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The neutron-rich lead isotopes, up to Pb-216, have been studied for the first time, exploiting the fragmentation of a primary uranium beam at the FRS-RISING setup at GSI. The observed isomeric states exhibit electromagnetic transition strengths which deviate from state-of-the-art shell-model calculations. It is shown that their complete description demands the introduction of effective three-body interactions and two-body transition operators in the conventional neutron valence space beyond Pb-208.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Joseph Nicolas Cugnot built the first primitive car in 1769 and approximately one hundred year later the first automotive race took place. Thanks to this, for the first time the aerodynamics principles began to be applied to cars. The aerodynamic study of a car is important to improve the performance on the road, or on the track. It purposely enhances the stability in the turns and increases the maximum velocity. However, it is also useful, decrease the fuel consumption, in order to reduce the pollution. Given that cars are a very complex body, the aerodynamic study cannot be conducted following an analytical method, but it is possible, in general, to choose between two different approaches: the numerical or the experimental one. The results of numerical studies depend on the computers’ potential and on the method use to implement the mathematical model. Today, the best way to perform an aerodynamic study is still experimental, which means that in the first phase of the design process the study is performed in a wind tunnel and in later phases directly on track. The automotive wind tunnels are singular mainly due to the test chamber, which typically contains a ground simulation system. The test chamber can have different types of walls: open walls, closed walls, adaptive walls or slotted walls. The best solution is to use the slotted walls because they minimize the interference between the walls and the streamlines, the interaction between the flow and the environment, and also to contain the overall costs. Furthermore, is necessary minimize the boundary layer at the walls, without accelerating the flow, in order to provide the maximum section of homogeneous flow. This thesis aims at redefining the divergent angle of the Dallara Automobili S.P.A. wind tunnel’s walls, in order to improve the overall homogeneity. To perform this study it was necessary to acquire the pressure data of the boundary layer, than it was created the profile of the boundary layer velocity and, to minimize the experimental errors, it was calculated the displacement thickness. The results obtained shows, even if the instrument used to the experiment was not the best one, that the boundary layer thickness could be minor in case of a low diffusion angle. So it is convenient to perform another experiment with a most sensitive instrument to verified what is the better wall configuration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Vitrectomy is a standard ophthalmic procedure to remove the vitreous body from the eye. The biomechanics of the vitreous affects its duration (by changing the removal rate) and the mechanical forces transmitted via the vitreous on the surrounding tissues during the procedure. Biomechanical characterization of the vitreous is essential for optimizing the design and control of instruments that operate within the vitreous for improved precision, safety, and efficacy. The measurements are carried out using a magnetic microprobe inserted into the vitreous, a method known as magnetic microrheology. The location of the probe is tracked by a microscope/camera while magnetic forces are exerted wirelessly by applied magnetic fields. In this work, in vitro artificial vitreous, ex vivo human vitreous and ex vivo porcine vitreous were characterized. In addition, in vivo rabbit measurements were performed using a suturelessly injected probe. Measurements indicate that viscoelasticity parameters of the ex vivo human vitreous are an order of magnitude different from those of the ex vivo porcine vitreous. The in vivo intra-operative measurements show typical viscoelastic behavior of the vitreous with a lower compliance than the ex vivo measurements. The results of the magnetic microrheology measurements were validated with those obtained by a standard atomic force microscopy (AFM) method and in vitro artificial vitreous. This method allows minimally-invasive characterization of localized mechanical properties of the vitreous in vitro, ex vivo, and in vivo. A better understanding of the characteristics of the vitreous can lead to improvements in treatments concerning vitreal manipulation such as vitrectomy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to establish the skin temperature (Tsk) thermal profile for the Brazilian population and to compare the differences between female and male Brazilian adults. A total of 117 female and 103 male were examined with a thermographic camera. The Tsk of 24 body regions of interest (ROI) were recorded and analyzed. Male Tsk results were compared to female and 10 ROI were evaluated with respect to the opposite side of the body (right vs. left) to identify the existence of significant contralateral Tsk differences (?Tsk). When compared right to left, the largest contralateral ?Tsk was 0.3 °C. The female vs. male analysis yielded significant differences (p menor que0.05) in 13 of the 24 ROI. Thigh regions, both ventral and dorsal, had the highest ?Tsk by sex (? 1.0 °C). Tsk percentile below P5 or P10 and over P9o or P95 may be used to characterize hypothermia and hyperthermia states, respectively. Thermal patterns and Tsk tables 2 were established for Brazilian adult men and women for each ROI. There is a low Tsk variation between sides of the body and gender differences were only significant for some ROIs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nowadays, the use of RGB-D sensors have focused a lot of research in computer vision and robotics. These kinds of sensors, like Kinect, allow to obtain 3D data together with color information. However, their working range is limited to less than 10 meters, making them useless in some robotics applications, like outdoor mapping. In these environments, 3D lasers, working in ranges of 20-80 meters, are better. But 3D lasers do not usually provide color information. A simple 2D camera can be used to provide color information to the point cloud, but a calibration process between camera and laser must be done. In this paper we present a portable calibration system to calibrate any traditional camera with a 3D laser in order to assign color information to the 3D points obtained. Thus, we can use laser precision and simultaneously make use of color information. Unlike other techniques that make use of a three-dimensional body of known dimensions in the calibration process, this system is highly portable because it makes use of small catadioptrics that can be placed in a simple manner in the environment. We use our calibration system in a 3D mapping system, including Simultaneous Location and Mapping (SLAM), in order to get a 3D colored map which can be used in different tasks. We show that an additional problem arises: 2D cameras information is different when lighting conditions change. So when we merge 3D point clouds from two different views, several points in a given neighborhood could have different color information. A new method for color fusion is presented, obtaining correct colored maps. The system will be tested by applying it to 3D reconstruction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Paper submitted to the 43rd International Symposium on Robotics (ISR2012), Taipei, Taiwan, Aug. 29-31, 2012.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Monitoring body temperature is essential in veterinary care as minor variations may indicate dysfunction. Rectal temperature is widely used as a proxy for body temperature, but measuring it requires special equipment, training or restraining, and it potentially stresses animals. Infrared thermography is an alternative that reduces handling stress, is safer for technicians and works well for untrained animals. This study analysed thermal reference points in five marine mammal species: bottlenose dolphin (Tursiops truncatus); beluga whale (Delphinapterus leucas); Patagonian sea lion (Otaria flavescens); harbour seal (Phoca vitulina); and Pacific walrus (Odobenus rosmarus divergens). RESULTS The thermogram analysis revealed that the internal blowhole mucosa temperature is the most reliable indicator of body temperature in cetaceans. The temperatures taken during voluntary breathing with a camera held perpendicularly were practically identical to the rectal temperature in bottlenose dolphins and were only 1 °C lower than the rectal temperature in beluga whales. In pinnipeds, eye temperature appears the best parameter for temperature control. In these animals, the average times required for temperatures to stabilise after hauling out, and the average steady-state temperature values, differed according to species: Patagonian sea lions, 10 min, 31.13 °C; harbour seals, 10 min, 32.27 °C; Pacific walruses, 5 min, 29.93 °C. CONCLUSIONS The best thermographic and most stable reference points for monitoring body temperature in marine mammals are open blowhole in cetaceans and eyes in pinnipeds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intermittent fasting (IF) is an often-used intervention to decrease body mass. In male Sprague-Dawley rats, 24 hour cycles of IF result in light caloric restriction, reduced body mass gain, and significant decreases in the efficiency of energy conversion. Here, we study the metabolic effects of IF in order to uncover mechanisms involved in this lower energy conversion efficiency. After 3 weeks, IF animals displayed overeating during fed periods and lower body mass, accompanied by alterations in energy-related tissue mass. The lower efficiency of energy use was not due to uncoupling of muscle mitochondria. Enhanced lipid oxidation was observed during fasting days, whereas fed days were accompanied by higher metabolic rates. Furthermore, an increased expression of orexigenic neurotransmitters AGRP and NPY in the hypothalamus of IF animals was found, even on feeding days, which could explain the overeating pattern. Together, these effects provide a mechanistic explanation for the lower efficiency of energy conversion observed. Overall, we find that IF promotes changes in hypothalamic function that explain differences in body mass and caloric intake.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare variations in bone mineral density (BMD) and body composition (BC) in depot-medroxyprogesterone acetate (DMPA) users and nonusers after providing counselling on healthy lifestyle habits. An exploratory study in which women aged 18 to 40 years participated: 29 new DMPA users and 25 new non-hormonal contraceptive users. All participants were advised on healthy lifestyle habits: sun exposure, walking and calcium intake. BMD and BC were assessed at baseline and 12 months later. Statistical analysis included the Mann-Whitney test or Student's t-test followed by multiple linear regression analysis. Compared to the controls, DMPA users had lower BMD at vertebrae L1 and L4 after 12 months of use. They also had a mean increase of 2 kg in total fat mass and an increase of 2.2% in body fat compared to the non-hormonal contraceptive users. BMD loss at L1 was less pronounced in DMPA users with a calcium intake ≥ 1 g/day compared to DMPA users with a lower calcium intake. DMPA use was apparently associated with lower BMD and an increase in fat mass at 12 months of use. Calcium intake ≥ 1 g/day attenuates BMD loss in DMPA users. Counselling on healthy lifestyle habits failed to achieve its aims.