978 resultados para Body Surface Area


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The objective of the study was to assess the bioequivalence of two tablet formulations of capecitabine and to explore the effect of age, gender, body surface area and creatinine clearance on the systemic exposure to capecitabine and its metabolites. Methods: The study was designed as an open, randomized two-way crossover trial. A single oral dose of 2000 mg capecitabine was administered on two separate days to 25 patients with solid tumors. On one day, the patients received four 500-mg tablets of formulation B (test formulation) and on the other day, four 500-mg tablets of formulation A (reference formulation). The washout period between the two administrations was between 2 and 8 days. After each administration, serial blood and urine samples were collected for up to 12 and 24 h, respectively. Unchanged capecitabine and its metabolites were determined in plasma using LC/MS-MS and in urine by NMRS. Results: Based on the primary pharmacokinetic parameter, AUC(0-∞) of 5'-DFUR, equivalence was concluded for the two formulations, since the 90% confidence interval of the estimate of formulation B relative to formulation A of 97% to 107% was within the acceptance region 80% to 125%. There was no clinically significant difference between the t(max) for the two formulations (median 2.1 versus 2.0 h). The estimate for C(max) was 111% for formulation B compared to formulation A and the 90% confidence interval of 95% to 136% was within the reference region 70% to 143%. Overall, these results suggest no relevant difference between the two formulations regarding the extent to which 5'-DFUR reached the systemic circulation and the rate at which 5'-DFUR appeared in the systemic circulation. The overall urinary excretions were 86.0% and 86.5% of the dose, respectively, and the proportion recovered as each metabolite was similar for the two formulations. The majority of the dose was excreted as FBAL (61.5% and 60.3%), all other chemical species making a minor contribution. Univariate and multivariate regression analysis to explore the influence of age, gender, body surface area and creatinine clearance on the log-transformed pharmacokinetic parameters AUC(0-∞) and C(max) of capecitabine and its metabolites revealed no clinically significant effects. The only statistically significant results were obtained for AUC(0-∞) and C(max) of intact drug and for C(max) of FBAL, which were higher in females than in males. Conclusion: The bioavailability of 5'-DFUR in the systemic circulation was practically identical after administration of the two tablet formulations. Therefore, the two formulations can be regarded as bioequivalent. The variables investigated (age, gender, body surface area, and creatinine clearance) had no clinically significant effect on the pharmacokinetics of capecitabine or its metabolites.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Peak flow rate data (Q(max)) are important for diagnosis of lower urinary tract obstruction. However, the lack of uroflowmetry studies in children, makes their interpretation difficult. With this aim, we studied 167 boys classified in four groups according to their age (G1 : n = 48, 6-7 years; G2 : n = 43, 8-9 years; G3 : n = 37, 10-11 years; G4: n = 39, 12-14 years). We studied in all children, weight, height, body surface area, peak flow rate (Q(max) and the correspondant urinary volume (Vol). Means and standard deviations of Q(max) (ml/sec) were : 15 +/- 5 (G1), 15 +/- 5 (G2), 17 +/- 5 (G3) and 22 +/- 7 (G4) respectively. Corresponding urinary volumes (Vol) (mean standard deviation - in ml) were : G1 = 123 +/- 75; G2 = 122 +/- 79; G3 = 158 +/- 96 and G4 = 162 +/- 101. We found a significant correlation (p < 0,01) between Q(max) and Vol in groups G2, G3 and G4; and between Q(max) and height in groups G1 and G4.The authors demonstrated a positive correlation between maximum flow and voided volume, and an increase of Q(max) with age.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Peak flow rate data (Qmax) are important for diagnosis of lower urinary tract obstruction. However, the lack of uroflowmetry studies in children, makes their interpretation difficult. With this aim, we studied 167 boys classified in four groups according to their age (G1: n = 48, 6-7 years; G2: n = 43, 8-9 years; G3: n = 37, 10-11 years; G4: n = 39, 12-14 years). We studied in all children, weight, height, body surface area, peak flow rate (Qmax) and the correspondant urinary volume (Vol). Means and standard deviations of Qmax (ml/sec) were: 15 +/- 5 (G1), 15 +/- 5 (G2), 17 +/- 5 (G3) and 22 +/- 7 (G4) respectively. Corresponding urinary volumes (Vol) (mean standard deviation-in ml) were: G1 = 123 +/- 75; G2 = 122 +/- 79; G3 = 158 +/- 96 and G4 = 162 +/- 101. We found a significant correlation (p < 0,01) between Qmax and Vol in groups G2, G3 and G4; and between Qmax and height in groups G1 and G4. The authors demonstrated a positive correlation between maximum flow and voided volume, and an increase of Qmax with age.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effects of particulate matter on environment and public health have been widely studied in recent years. A number of studies in the medical field have tried to identify the specific effect on human health of particulate exposure, but agreement amongst these studies on the relative importance of the particles’ size and its origin with respect to health effects is still lacking. Nevertheless, air quality standards are moving, as the epidemiological attention, towards greater focus on the smaller particles. Current air quality standards only regulate the mass of particulate matter less than 10 μm in aerodynamic diameter (PM10) and less than 2.5 μm (PM2.5). The most reliable method used in measuring Total Suspended Particles (TSP), PM10, PM2.5 and PM1 is the gravimetric method since it directly measures PM concentration, guaranteeing an effective traceability to international standards. This technique however, neglects the possibility to correlate short term intra-day variations of atmospheric parameters that can influence ambient particle concentration and size distribution (emission strengths of particle sources, temperature, relative humidity, wind direction and speed and mixing height) as well as human activity patterns that may also vary over time periods considerably shorter than 24 hours. A continuous method to measure the number size distribution and total number concentration in the range 0.014 – 20 μm is the tandem system constituted by a Scanning Mobility Particle Sizer (SMPS) and an Aerodynamic Particle Sizer (APS). In this paper, an uncertainty budget model of the measurement of airborne particle number, surface area and mass size distributions is proposed and applied for several typical aerosol size distributions. The estimation of such an uncertainty budget presents several difficulties due to i) the complexity of the measurement chain, ii) the fact that SMPS and APS can properly guarantee the traceability to the International System of Measurements only in terms of number concentration. In fact, the surface area and mass concentration must be estimated on the basis of separately determined average density and particle morphology. Keywords: SMPS-APS tandem system, gravimetric reference method, uncertainty budget, ultrafine particles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to quantify exposure to particles emitted by wood-fired ovens in pizzerias. Overall, 15 microenvironments were chosen and analyzed in a 14-month experimental campaign. Particle number concentration and distribution were measured simultaneously using a Condensation Particle Counter (CPC), a Scanning Mobility Particle Sizer (SMPS), an Aerodynamic Particle Sizer (APS). The surface area and mass distributions and concentrations, as well as the estimation of lung deposition surface area and PM1 were evaluated using the SMPS-APS system with dosimetric models, by taking into account the presence of aggregates on the basis of the Idealized Aggregate (IA) theory. The fraction of inhaled particles deposited in the respiratory system and different fractions of particulate matter were also measured by means of a Nanoparticle Surface Area Monitor (NSAM) and a photometer (DustTrak DRX), respectively. In this way, supplementary data were obtained during the monitoring of trends inside the pizzerias. We found that surface area and PM1 particle concentrations in pizzerias can be very high, especially when compared to other critical microenvironments, such as the transport hubs. During pizza cooking under normal ventilation conditions, concentrations were found up to 74, 70 and 23 times higher than background levels for number, surface area and PM1, respectively. A key parameter is the oven shape factor, defined as the ratio between the size of the face opening in respect

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to develop a reliable technique for measuring the area of a curved surface from an axial computed tomography (CT) scan and to apply this clinically in the measurement of articular cartilage surface area in acetabular fractures. The method used was a triangulation algorithm. In order to determine the accuracy of the technique, areas of hemispheres of known size were measured to give the percentage error in area measurement. Seven such hemispheres were machined into a Perspex block and their area measured geometrically, and also from CT scans by means of the triangulation algorithm. Scans of 1, 2 and 4 mm slice thickness and separation were used. The error varied with slice thickness and hemisphere diameter. It was shown that the 2 mm slice thickness provides the most accurate area measurement, while 1 mm cuts overestimate and 4 mm cuts underestimate the area. For a hemisphere diameter of 5 cm, which is of similar size to the acetabulum, the error was -11.2% for 4 mm cuts, +4.2% for 2 mm cuts and + 5.1% for 1 mm cuts. As expected, area measurement was more accurate for larger hemispheres. This method can be applied clinically to quantify acetabular fractures by measuring the percentage area of intact articular cartilage. In the case of both column fractures, the percentage area of secondary congruence can be determined. This technique of quantifying acetabular fractures has a potential clinical application as a prognostic factor and an indication for surgery in the long term.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Synthetic goethite and thermally treated goethite at different temperatures were used to remove phosphate from sewage. The effect of annealing temperature on phosphate removal over time was investigated. X-ray diffraction(XRD), transmission electron microscopy (TEM), N2 adsorption and desorption (BET), and infrared emission spectrum (FT-IES) were utilized to characterize the phase, morphology, specific surface area, pore distribution, and the surface groups of samples. The results show that annealed products of goethite at temperatures over 250 °C are hematite with the similar morphology as the original goethite with different hydroxyl groups and surface area. Increasing temperature causes the decrease in hydroxyl groups, consequential increase in surface area at first and then experiences a decrease (14.8–110.4–12.6 m2/g) and the subsequent formation of nanoscale pores. The variation rate of hydroxyl groups and surface area based on FT-IES and BET, respectively, are used to evaluate the effect of annealing temperature on phosphate removal. By using all of the characterization techniques, it is concluded that the changes of phosphate removal basically result from the total variation rate between hydroxyl groups and surface area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The surface area of inhaled particles deposited in the alveolar region, as reported by the TSI nanoparticle surface area monitor (NSAM), was compared with the corresponding value estimated by a TSI scanning mobility particle sizer (SMPS) for a range of environmentally relevant aerosols, including petrol emissions, ETS, laser printer emissions, cooking emissions and ambient aerosols. The SMPS values were based on a mobility size distribution assuming spherical particles using the appropriate size-dependent alveolar-deposition factors provided by the ICRP. In most cases, the two instruments showed good linear agreement. With petrol emissions and ETS, the linearity extended to over 103 μm2 cm-3. With printer emissions, there was good linearity up to about 300 μm2 cm-3 while the NSAM increasingly overestimated the surface area at higher concentrations. The presence of a nucleation event in ambient air caused the NSAM to over-estimate the surface area by a factor of 2. We summarize these results and conclude that the maximum number concentration up to which the NSAM is accurate clearly depends on the type of aerosol being sampled and provide guidance for the use of the instrument.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is considerable scientific interest in personal exposure to ultrafine particles. Owing to their small size, these particles are able to penetrate deep into the lungs, where they may cause adverse respiratory, pulmonary and cardiovascular health effects. This article presents Bayesian hierarchical models for estimating and comparing inhaled particle surface area in the lung.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this paper is to determine the suitability of solely stationary measurements for exposure assessment and management applications. For this purpose, quantified inhaled particle surface area (IPSA) doses using both stationary and personal particle exposure monitors were evaluated and compared.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nanoporous structures with high active surface areas are critical for a variety of applications. Here, we present a general templateless strategy to produce such porous structures by controlled aggregation of nanostructured subunits and apply the principles for synthesizing nanoporous Pt for electrocatalytic oxidation of methanol. The nature of the aggregate produced is controlled by tuning the electrostatic interaction between surfactant-free nanoparticles in the solution phase. When the repulsive force between the particles is very large, the particles are stabilized in the solution while instantaneous aggregation leading to fractal-like structures results when the repulsive force is very low. Controlling the repulsive interaction to an optimum, intermediate value results in the formation of compact structures with very large surface areas. In the case of Pt, nanoporous clusters with an extremely high specific surface area (39 m(2)/g) and high activity for methanol oxidation have been produced. Preliminary investigations indicate that the method is general and can be easily extended to produce nanoporous structures of many inorganic materials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prediction of thermodynamic parameters of protein-protein and antigen-antibody complex formation from high resolution structural parameters has recently received much attention, since an understanding of the contributions of different fundamental processes like hydrophobic interactions, hydrogen bonding, salt bridge formation, solvent reorganization etc. to the overall thermodynamic parameters and their relations with the structural parameters would lead to rational drug design. Using the results of the dissolution of hydrocarbons and other model compounds the changes in heat capacity (DeltaCp), enthalpy (DeltaH) and entropy (DeltaS) have been empirically correlated with the polar and apolar surface areas buried during the process of protein folding/unfolding and protein-ligand complex formation. In this regard, the polar and apolar surfaces removed from the solvent in a protein-ligand complex have been calculated from the experimentally observed values of changes in heat capacity (DeltaCp) and enthalpy (DeltaH) for protein-ligand complexes for which accurate thermodynamic and high resolution structural data are available, and the results have been compared with the x-ray crystallographic observations. Analyses of the available results show poor correlation between the thermodynamic and structural parameters. Probable reasons for this discrepancy are mostly related with the reorganization of water accompanying the reaction which is indeed proven by the analyses of the energetics of the binding of the wheat germ agglutinin to oligosaccharides.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the studies was to improve the diagnostic capability of electrocardiography (ECG) in detecting myocardial ischemic injury with a future goal of an automatic screening and monitoring method for ischemic heart disease. The method of choice was body surface potential mapping (BSPM), containing numerous leads, with intention to find the optimal recording sites and optimal ECG variables for ischemia and myocardial infarction (MI) diagnostics. The studies included 144 patients with prior MI, 79 patients with evolving ischemia, 42 patients with left ventricular hypertrophy (LVH), and 84 healthy controls. Study I examined the depolarization wave in prior MI with respect to MI location. Studies II-V examined the depolarization and repolarization waves in prior MI detection with respect to the Minnesota code, Q-wave status, and study V also with respect to MI location. In study VI the depolarization and repolarization variables were examined in 79 patients in the face of evolving myocardial ischemia and ischemic injury. When analyzed from a single lead at any recording site the results revealed superiority of the repolarization variables over the depolarization variables and over the conventional 12-lead ECG methods, both in the detection of prior MI and evolving ischemic injury. The QT integral, covering both depolarization and repolarization, appeared indifferent to the Q-wave status, the time elapsed from MI, or the MI or ischemia location. In the face of evolving ischemic injury the performance of the QT integral was not hampered even by underlying LVH. The examined depolarization and repolarization variables were effective when recorded in a single site, in contrast to the conventional 12-lead ECG criteria. The inverse spatial correlation of the depolarization and depolarization waves in myocardial ischemia and injury could be reduced into the QT integral variable recorded in a single site on the left flank. In conclusion, the QT integral variable, detectable in a single lead, with optimal recording site on the left flank, was able to detect prior MI and evolving ischemic injury more effectively than the conventional ECG markers. The QT integral, in a single-lead or a small number of leads, offers potential for automated screening of ischemic heart disease, acute ischemia monitoring and therapeutic decision-guiding as well as risk stratification.