990 resultados para Blue values, mean


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Public values are moving from a research concern to policy discourse and management practice. There are, though, different readings of what public values actually mean. Reflection suggests two distinct strands of thinking: a generative strand that sees public value emerging from processes of public debate; and an institutional interpretation that views public values as the attributes of government producers. Neither perspective seems to offer a persuasive account of how the public gains from strengthened public values. Key propositions on values are generated from comparison of influential texts. A provisional framework is presented of the values base of public institutions and the loosely coupled public propositions flowing from these values. Value propositions issue from different governing contexts, which are grouped into policy frames that then compete with other problem frames for citizens’ cognitive resources. Vital democratic commitments to pluralism require public values to be distributed in competition with other, respected, frames.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL) on contrast sensitivity and blue-on-yellow perimetry. METHODS: This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes) received aspherical intraocular lens in one eye and spherical intraocular lens in the fellow eye; and 27 patients (54 eyes) received ultraviolet and blue light filter (yellow tinted) IOL implantation in one eye and acrylic ultraviolet filter IOL in the fellow eye. The primary outcome measures were contrast sensitivity and blue-on-yellow perimetry values (mean deviation [MD] and pattern standard deviation [PSD]) investigated two years after surgery. The results were compared intra-individually. RESULTS: There was a statistically significant between-group (aspherical and spherical intraocular lens) difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. There were no between-group significant differences (yellow tinted and clear intraocular lens) under photopic or mesopic conditions. There was no statistically significant difference between all intraocular lens in MD or PSD. CONCLUSION: Contrast sensitivity was better under mesopic conditions with aspherical intraocular lens. Blue-on-yellow perimetry did not appear to be affected by aspherical or yellow tinted intraocular lens. Further studies with a larger sample should be carried out to confirm or not that hypotheses.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background Skin temperature assessment is a promising modality for early detection of diabetic foot problems, but its diagnostic value has not been studied. Our aims were to investigate the diagnostic value of different cutoff skin temperature values for detecting diabetes-related foot complications such as ulceration, infection, and Charcot foot and to determine urgency of treatment in case of diagnosed infection or a red-hot swollen foot. Materials and Methods The plantar foot surfaces of 54 patients with diabetes visiting the outpatient foot clinic were imaged with an infrared camera. Nine patients had complications requiring immediate treatment, 25 patients had complications requiring non-immediate treatment, and 20 patients had no complications requiring treatment. Average pixel temperature was calculated for six predefined spots and for the whole foot. We calculated the area under the receiver operating characteristic curve for different cutoff skin temperature values using clinical assessment as reference and defined the sensitivity and specificity for the most optimal cutoff temperature value. Mean temperature difference between feet was analyzed using the Kruskal–Wallis tests. Results The most optimal cutoff skin temperature value for detection of diabetes-related foot complications was a 2.2°C difference between contralateral spots (sensitivity, 76%; specificity, 40%). The most optimal cutoff skin temperature value for determining urgency of treatment was a 1.35°C difference between the mean temperature of the left and right foot (sensitivity, 89%; specificity, 78%). Conclusions Detection of diabetes-related foot complications based on local skin temperature assessment is hindered by low diagnostic values. Mean temperature difference between two feet may be an adequate marker for determining urgency of treatment.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

With a focus on white marlin (Tetrapturus albidus), a concurrent electronic tagging and larval sampling effort was conducted in the vicinity of Mona Passage (off southeast Hispaniola), Dominican Republic, during April and May 2003. Objectives were 1) to characterize the horizontal and vertical movement of adults captured from the area by using pop-up satellite archival tags (PSATs); and 2) by means of larval sampling, to investigate whether fish were reproducing. Trolling from a sportfishing vessel yielded eight adult white marlin and one blue marlin (Makaira nigricans); PSAT tags were deployed on all but one of these individuals. The exception was a female white marlin that was unsuitable for tagging because of injury; the reproductive state of its ovaries was examined histologically. Seven of the PSATs reported data summaries for water depth, temperature, and light levels measured every minute for periods ranging from 28 to 40 days. Displacement of marlin from the location of release to the point of tag pop-up ranged from 3l.6 to 267.7 nautical miles (nmi) and a mean displacement was 3.4 nmi per day for white marlin. White and blue marlin mean daily displacements appeared constrained compared to the results of other marlin PSAT tagging studies. White marlin ovarian sections contained postovulatory follicles and final maturation-stage oocytes, which indicated recent and imminent spawning. Neuston tows (n=23) yielded 18 istiophorid larvae: eight were white marlin, four were blue marlin, and six could not be identified to species. We speculate that the constrained movement patterns of adults may be linked to reproductive activity for both marlin species, and, if true, these movement patterns may have several implications for management. Protection of the potentially important white marlin spawning ground near Mona Passage seems warranted, at least until further studies can be conducted on the temporal and spatial extent of reproduction and associated adult movement.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose Transient changes in corneal topography associated with soft and conventional or reverse geometry rigid contact lens wear have been well documented; however, only a few studies have examined the influence of scleral contact lens wear upon the cornea. Therefore, in this study, we examined the influence of modern miniscleral contact lenses, which land entirely on the sclera and overlying tissues, upon anterior corneal curvature and optics. Methods Anterior corneal topography and elevation data were acquired using Scheimpflug imaging (Pentacam HR, Oculus) immediately prior to and following 8 hours of miniscleral contact lens wear in 15 young healthy adults (mean age 22 ± 3 years, 8 East Asian, 7 Caucasian) with normal corneae. Corneal diurnal variations were accounted for using data collected on a dedicated measurement day without contact lens wear. Corneal clearance was quantified using an optical coherence tomographer (RS-3000, Nidek) following lens insertion and after 8 hours of lens wear. Results Although corneal clearance was maintained throughout the 8 hour lens wear period, significant corneal flattening (up to 0.08 ± 0.04 mm) was observed, primarily in the superior mid-peripheral cornea, which resulted in a slight increase in against-the-rule corneal astigmatism (mean +0.02/-0.15 x 94 for an 8 mm diameter). Higher order aberration terms of horizontal coma, vertical coma and spherical aberration all underwent significant changes for an 8 mm corneal diameter (p ≤ 0.01), which typically resulted in a decrease in RMS error values (mean change in total higher order RMS -0.035 ± 0.046 µm for an 8 mm diameter). There was no association between the magnitude of change in central or mid-peripheral corneal clearance during lens wear and the observed changes in corneal curvature (p > 0.05). However, Asian participants displayed a significantly greater reduction in corneal clearance (p = 0.04) and greater superior-nasal corneal flattening compared to Caucasians (p = 0.048). Conclusions Miniscleral contact lenses that vault the cornea induce significant changes in anterior corneal surface topography and higher order aberrations following 8 hours of lens wear. The region of greatest corneal flattening was observed in the superior-nasal mid-periphery, more so in Asian participants. Practitioners should be aware that corneal measurements obtained following miniscleral lens removal may mask underlying corneal steepening.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Indicator inks, previously shown to be capable of rapidly assessing photocatalytic activity via a novel photo-reductive mechanism, were simply applied via an aerosol spray onto commercially available pieces of Activ (TM) self-cleaning glass. Ink layers could be applied with high evenness of spread, with as little deviation as 5% upon UV-visible spectroscopic assessment of 25 equally distributed positions over a 10 cm x 10 cm glass cut. The inks were comprised of either a resazurin (Rz) or dichloroindophenol (DCIP) redox dye with a glycerol sacrificial electron donor in an aqueous hydroxyethyl cellulose (HEC) polymer media. The photo-reduction reaction under UVA light of a single spot was monitored by UV-vis spectroscopy and digital images attained from a flat-bed scanner in tandem for both inks. The photo-reduction of Rz ink underwent a two-step kinetic process, whereby the blue redox dye was initially reduced to a pink intermediate resorufin (Rf) and subsequently reduced to a bleached form of the dye. In contrast, a simple one-step kinetic process was observed for the reduction of the light blue redox dye DCIP to its bleached intermediates. Changes in red-green-blue colour extracted from digital images of the inks were inversely proportional to the changes seen at corresponding wavelengths via UV-visible absorption spectroscopy and wholly indicative of the reaction kinetics. The photocatalytic activity areas of cuts of Activ (TM) glass, 10 cm x 10 cm in size, were assessed using both Rz and DCIP indicator inks evenly sprayed over the films: firstly using UVA lamp light to activate the underlying Activ (TM) film (1.75 mW cm(-2)) and secondly under solar conditions (2.06 +/- 0.14 mW cm(-2)). The photo-reduction reactions were monitored solely by flat-bed digital scanning. Red-green-blue values of a generated 14 x 14 grid (196 positions) that covered the entire area of each film image were extracted using a Custom-built program entitled RGB Extractor(C). A homogenous degradation over the 196 positions analysed for both Rz (Red colour deviation = 19% UVA, 8% Solar: Green colour deviation = 17% UVA, 12% Solar) and DCIP (Red colour deviation = 22% UVA, 16% Solar) inks was seen in both UVA and solar experiments, demonstrating the consistency of the self-cleaning titania layer on Activ (TM). The method presented provides a good solution for the high-throughput photocatalytic screening of a number of homogenous photocatalytically active materials simultaneously or numerous positions on a single film; both useful in assessing the homogeneity of a film or determining the best combination of reaction components to produce the optimum performance photocatalytic film. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An intelligent ink, previously shown to be capable of rapidly assessing photocatalytic activity, was simply applied via a felt-pen onto a commercially available piece of Activ (TM) self-cleaning glass. The ink, comprising of redox dye resazurin and the sacrificial electron donor glycerol within an aqueous hydroxy ethyl cellulose (HEC) polymer media, was photocatalytically degraded in a two-step process. The key initial stage was the photo-reductive conversion of resazurin to resorufin, whereby a colour change from blue to pink occurred. The latter stage was the subsequent photo-reduction of the resorufin, where a slower change from pink to colourless was seen. Red and green components of red-green-blue colour extracted from flat-bed scanner digital images of resazurin ink coated photocatalytic films at intervals during the photocatalysis reaction were inversely proportional to the changes seen via UV-visible absorption spectroscopy and indicative of reaction kinetics. A 3 x 3 grid of intelligent ink was drawn onto a piece of Activ (TM) and a glass blank. The photocatalysis reaction was monitored solely by flat-bed digital scanning. Red-green-blue values of respective positions on the grid were extracted using a custom-built program entitled RGB Extractor (c). The program was capable of extracting a number of 5 x 5 pixel averages of red-green-blue components simultaneously. Allocation of merely three coordinates allowed for the automatic generation of a grid, with scroll-bars controlling the number of positions to be extracted on the grid formed. No significant change in red and green components for any position on the glass blank was observed; however, the Activ (TM) film displayed a homogenous photo-reduction of the dye, reaching maxima in red and minima in green components in 23 +/- 3 and 14 +/- 2 min, respectively. A compositionally graded N-doped titania film synthesised in house via a combinatorial APCVD reaction was also photocatalytically tested by this method where 247 positions on a 13 x 19 grid were simultaneously analysed. The dramatic variation in photocatalysis observed was rapidly quantified for all positions (2-3 hours) allowing for correlations to be made between thicknesses and N : Ti% compositions attained from Swanepoel and WDX analysis, respectively. N incorporation within this system was found to be detrimental to film activity for the photocatalysis reaction of intelligent ink under 365 nm light.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Studies investigating the association between glycated hemoglobin (HbA) level and mortality risk in diabetic patients receiving hemodialysis have shown conflicting results. 
Study Design: We conducted a systematic review and meta-analysis using MEDLINE, EMBASE, Web of Science, and the Cochrane Library. 
Setting & Population: Diabetic patients on maintenance hemodialysis therapy. 
Selection Criteria for Studies: Observational studies or randomized controlled trials investigating the association between HbA values and mortality risk. Study authors were asked to provide anonymized individual patient data or reanalyze results according to a standard template. 
Predictor: Single measurement or mean HbA values. Mean HbA values were calculated using all individual-patient HbA values during the follow-up period of contributing studies. 
Outcome: HR for mortality risk. 
Results: 10 studies (83,684 participants) were included: 9 observational studies and one secondary analysis of a randomized trial. After adjustment for confounders, patients with baseline HbA levels =8.5% (=69 mmol/mol) had increased mortality (7 studies; HR, 1.14; 95% CI, 1.09-1.19) compared with patients with HbA levels of 6.5%-7.4% (48-57 mmol/mol). Likewise, patients with a mean HbA value =8.5% also had a higher adjusted risk of mortality (6 studies; HR,1.29; 95% CI, 1.23-1.35). There was a small but nonsignificant increase in mortality associated with mean HbA levels =5.4% (=36 mmol/mol; 6 studies; HR, 1.09; 95% CI, 0.89-1.34). Sensitivity analyses in incident (=90 days of hemodialysis) and prevalent patients (>90 days of hemodialysis) showed a similar pattern. In incident patients, mean HbA levels =5.4% also were associated with increased mortality risk (4 studies; HR, 1.29; 95% CI, 1.23-1.35). 
Limitations: Observational study data and inability to adjust for diabetes type in all studies. 
Conclusions: Despite concerns about the utility of HbA measurement in hemodialysis patients, high levels (=8.5%) are associated with increased mortality risk. Very low HbA levels (=5.4%) also may be associated with increased mortality risk. 

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This contribution describes the optimization of chlorine extraction from silicate samples by pyrohydrolysis prior to the precise determination of Cl stable-isotope compositions (637 Cl) by gas source, dual inlet Isotope Ratio Mass Spectrometry (IRMS) on CH(3)Clg. The complete method was checked on three international reference materials for Cl-content and two laboratory glass standards. Whole procedure blanks are lower than 0. 5 mu mol, corresponding to less than 10 wt.% of most of the sample chloride analysed. In the absence of international chlorine isotope rock, we report here Cl extracted compared to accepted Cl contents and reproducibilities on Cl and delta Cl-37 measurements for the standard rocks. After extraction, the Cl contents of the three international references compared within error with the accepted values (mean yield = 94 +/-10%) with reproducibilities better than 12% (10). The laboratory glass standards - andesite SO100DS92 and phonolite S9(2) - were used specifically to test the effect of chloride amount on the measurements. They gave Cl extraction yields of 100 +/-6% (1 sigma-; n = 15) and 105 +/- 8% (1 sigma-; n = 7), respectively, with delta Cl-37 values of -0.51 0.14%o and -0.39 0.17%o (1g). In summary, for silicate samples with Cl contents between 39 and 9042 ppm, the Pyrohydrolysis/HPLC method leads to overall CI extraction yields of 100 8%, reproducibilities on Cl contents of 7% and on delta Cl-37 measurements of 0.12%o (all 1 sigma). The method was further applied to ten silicate rocks of various mineralogy and chemistry (meteorite, fresh MORB glasses, altered basalts and setpentinized peridotites) chosen for their large range of Cl contents (70-2156 ppm) and their geological significance. delta Cl-37 values range between -2.33 and -0.50%o. These strictly negative values contrast with the large range and mainly positive values previously reported for comparable silicate samples and shown here to be affected by analytical problems. Thus we propose a preliminary, revised terrestrial CI cycle, mainly dominated by negative and zero delta Cl-37 values. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Measurements of weighted dietary intakes and plasma determinations of albumin, iron, zinc, ascorbic acid and TIBC were carried out on twenty female multiple sclerosis patients in a long-stay hospital for disabled people. The group included ten patients with a recent history of pressure sores, closely matched with ten patients without pressure sores. Mean daily intake of carbohydrate was found to be higher in the non-pressure sore group whilst intake of zinc was lower in this group. Intakes of all other nutrients were comparable between the two groups. For both groups, intakes of energy, folate, vitamin D, iron and zinc were less than recommended values. Mean plasma levels of albumin and iron were towards the lower limit of the normal range, whilst that for zinc was considerably less than the normal range. Plasma TIBC was slightly above the normal range. Levels of plasma iron and zinc were significantly lower in the pressure sore group. The data indicate that severely disabled hospitalized patients with multiple sclerosis may be at risk of poor nutritional status. The results suggest that in the presence of pressure sores, there are increased requirements for specific nutrients, notably zinc and iron. Consideration is given to the possible value of supplementation of these individuals.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The static and cyclic assays are common to test materials in structures.. For cycling assays to assess the fatigue behavior of the material and thereby obtain the S-N curves and these are used to construct the diagrams of living constant. However, these diagrams, when constructed with small amounts of S-N curves underestimate or overestimate the actual behavior of the composite, there is increasing need for more testing to obtain more accurate results. Therewith, , a way of reducing costs is the statistical analysis of the fatigue behavior. The aim of this research was evaluate the probabilistic fatigue behavior of composite materials. The research was conducted in three parts. The first part consists of associating the equation of probability Weilbull equations commonly used in modeling of composite materials S-N curve, namely the exponential equation and power law and their generalizations. The second part was used the results obtained by the equation which best represents the S-N curves of probability and trained a network to the modular 5% failure. In the third part, we carried out a comparative study of the results obtained using the nonlinear model by parts (PNL) with the results of a modular network architecture (MN) in the analysis of fatigue behavior. For this we used a database of ten materials obtained from the literature to assess the ability of generalization of the modular network as well as its robustness. From the results it was found that the power law of probability generalized probabilistic behavior better represents the fatigue and composites that although the generalization ability of the MN that was not robust training with 5% failure rate, but for values mean the MN showed more accurate results than the PNL model

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Neste artigo discute-se o trabalho com valores em Educação Ambiental, o que exige uma fundamentação e posicionamento adequados. Diante do impasse entre posições relativistas e universalistas para a educação em valores, aponta-se para a necessidade de explicitar nossa posição e ação em favor dos valores ambientalmente desejáveis, considerando que as questões envolvidas com o meio ambiente dizem respeito à vida e à sobrevivência de todos os seres do planeta. Estes valores podem ser identificados junto aos princípios presentes no Tratado de educação global para sociedades sustentáveis e responsabilidade global, apresentado pela sociedade civil na ECO-92. Por fim, ressalta-se a necessidade de se desenvolverem estratégias educativas que envolvam as dimensões aqui denominadas de cognição, afetividade e ação, resultando em um trabalho abrangente, que amplie as possibilidades de o indivíduo apreender, de maneira mais efetiva, um dado valor, tendo, então, melhores condições de construí-lo em sua vida.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: This study evaluated the surface hardness of a resin cement (RelyX ARC) photoactivated through indirect composite resin (Cristobal) disks of different thicknesses using either a light- emitting diode (LED) or quartz tungsten halogen (QTH) light source. Material and Methods: Eighteen resin cement specimens were prepared and divided into 6 groups according to the type of curing unit and the thickness of resin disks interposed between the cement surface and light source. Three indentations (50 g for 15 s) were performed on the top and bottom surface of each specimen and a mean Vickers hardness number (VHN) was calculated for each specimen. The data were analyzed using two-way ANOVA and Tukey-Kramer test was used for post-hoc pairwise comparisons. Results: Increased indirect resin disk thickness resulted in decreased mean VHN values. Mean VHN values for the top surfaces of the resin cement specimens ranged from 23.2 to 46.1 (QTH) and 32.3 to 41.7 (LED). The LED curing light source produced higher hardness values compared to the QTH light source for 2- and 3-mm-thick indirect resin disks. The differences were clinically, but not statistically significant. Increased indirect resin disk thickness also resulted in decreased mean VHN values for the bottom surfaces of the resin cement: 5.8 to 19.1 (QTH) and 7.5 to 32.0 (LED). For the bottom surfaces, a statistically significant interaction was also found between the type of curing light source and the indirect resin disk thickness. Conclusions: Mean surface hardness values of resin cement specimens decreased with the increase of indirect resin disk thickness. The LED curing light source generally produced higher surface hardness values.