974 resultados para Blood gas analysis
Resumo:
BACKGROUND AND PURPOSE: A right-to-left shunt can be identified by contrast transcranial Doppler ultrasonography (c-TCD) at rest and/or after a Valsalva maneuver (VM) or by arterial blood gas (ABG) measurement. We assessed the influence of controlled strain pressures and durations during VM on the right-to-left passage of microbubbles, on which depends the shunt classification by c-TCD, and correlated it with the right-to-left shunt evaluation by ABG measurements in stroke patients with patent foramen ovale (PFO). METHODS: We evaluated 40 stroke patients with transesophageal echocardiography-documented PFO. The microbubbles were recorded with TCD at rest and after 4 different VM conditions with controlled duration and target strain pressures (duration in seconds and pressure in cm H2O, respectively): V5-20, V10-20, V5-40, and V10-40. The ABG analysis was performed after pure oxygen breathing in 34 patients, and the shunt was calculated as percentage of cardiac output. RESULTS: Among all VM conditions, V5-40 and V10-40 yielded the greatest median number of microbubbles (84 and 95, respectively; P<0.01). A significantly larger number of microbubbles were detected in V5-40 than in V5-20 (P<0.001) and in V10-40 than in V10-20 (P<0.01). ABG was not sensitive enough to detect a shunt in 31 patients. CONCLUSIONS: The increase of VM expiratory pressure magnifies the number of microbubbles irrespective of the strain duration. Because the right-to-left shunt classification in PFO is based on the number of microbubbles, a controlled VM pressure is advised for a reproducible shunt assessment. The ABG measurement is not sensitive enough for shunt assessment in stroke patients with PFO.
Resumo:
PURPOSE: Resuscitated cardiac arrest (CA) patients typically receive therapeutic hypothermia, but arterial blood gases (ABGs) are often assessed after adjustment to 37°C (alpha-stat) instead of actual body temperature (pH-stat). We sought to compare alpha-stat and pH-stat assessment of Pao2 and Paco2 in such patients. MATERIALS AND METHODS: Using ABG data obtained during the first 24 hours of intensive care unit admission, we determined the impact of measured alpha vs calculated pH-stat on Pao2 and Paco2 on patient classification and outcomes for CA patients. RESULTS: We assessed 1013 ABGs from 120 CA patients with a median age of patients 66 years (interquartile range, 50-76). Median alpha-stat Pao2 changed from 122 (95-156) to 107 (82-143) mm Hg with pH-stat and median Paco2 from 39 (34-46) to 35 (30-41) mm Hg (both P < .001). Using the categories of hyperoxemia, normoxemia, and hypoxemia, pH-stat estimation of Pao2 reclassified approximately 20% of patients. Using the categories of hypercapnia, normocapnia, and hypocapnia, pH stat estimation of Paco2 reclassified approximately 40% of patients. The mortality of patients in different Pao2 and Paco2 categories was similar for pH-stat and alpha-stat. CONCLUSIONS: Using the pH-stat method, fewer resuscitated CA patients admitted to intensive care unit were classified as hyperoxemic or hypercapnic compared with alpha-stat. These findings suggest an impact of ABG assessment methodology on Pao2, Paco2, and patient classification but not on associated outcomes.
Resumo:
BACKGROUND AND OBJECTIVE: Arterial base excess and lactate levels are key parameters in the assessment of critically ill patients. The use of venous blood gas analysis may be of clinical interest when no arterial blood is available initially. METHODS: Twenty-four pigs underwent progressive normovolaemic haemodilution and subsequent progressive haemorrhage until the death of the animal. Base excess and lactate levels were determined from arterial and central venous blood after each step. In addition, base excess was calculated by the Van Slyke equation modified by Zander (BE(z)). Continuous variables were summarized as mean +/- SD and represent all measurements (n = 195). RESULTS: Base excess according to National Committee for Clinical Laboratory Standards for arterial blood was 2.27 +/- 4.12 versus 2.48 +/- 4.33 mmol(-l) for central venous blood (P = 0.099) with a strong correlation (r(2) = 0.960, P < 0.001). Standard deviation of the differences between these parameters (SD-DIFBE) did not increase (P = 0.355) during haemorrhage as compared with haemodilution. Arterial lactate was 2.66 +/- 3.23 versus 2.71 +/- 2.80 mmol(-l) in central venous blood (P = 0.330) with a strong correlation (r(2) = 0.983, P < 0.001). SD-DIFLAC increased (P < 0.001) during haemorrhage. BE(z) for central venous blood was 2.22 +/- 4.62 mmol(-l) (P = 0.006 versus arterial base excess according to National Committee for Clinical Laboratory Standards) with strong correlation (r(2) = 0.942, P < 0.001). SD-DIFBE(z)/base excess increased (P < 0.024) during haemorrhage. CONCLUSION: Central venous blood gas analysis is a good predictor for base excess and lactate in arterial blood in steady-state conditions. However, the variation between arterial and central venous lactate increases during haemorrhage. The modification of the Van Slyke equation by Zander did not improve the agreement between central venous and arterial base excess.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
In a surfactant-depletion model of lung injury, tidal recruitment of atelectasis and changes in shunt fraction lead to large Pao2 oscillations. We investigated the effect of these oscillations on conventional arterial blood gas (ABG) results using different sampling techniques in ventilated rabbits. In each rabbit, 5 different ventilator settings were studied, 2 before saline lavage injury and 3 after lavage injury. Ventilator settings were altered according to 5 different goals for the amplitude and mean value of brachiocephalic Pao2 oscillations, as guided by a fast responding intraarterial probe. ABG collection was timed to obtain the sample at the peak or trough of the Pao2 oscillations, or over several respiratory cycles. Before lung injury, oscillations were small and sample timing did not influence Pao2. After saline lavage, when Po2 fluctuations measured by the indwelling arterial Po2 probe confirmed tidal recruitment, Pao2 by ABG was significantly higher at peak (295 +/- 130 mm Hg) compared with trough (74 +/- 15 mm Hg) or mean (125 +/- 75 mm Hg). In early, mild lung injury after saline lavage, Pao2 can vary markedly during the respiratory cycle. When atelectasis is recruited with each breath, interpretation of changes in shunt fraction, based on conventional ABG analysis, should account for potentially large respiratory variations in arterial Po2.
Resumo:
The aim was to provide reference data for blood gas/acid-base status and electrolytes for non-anesthetized Amazon parrots (Amazona aestiva). Thirty-five adult parrots from Tietê ecologic park were utilized. Arterial blood (0.3ml) samples were anaerobically collected from the superficial ulnar artery in heparinized (sodium heparin) 1-ml plastic syringes. The samples were immediately analyzed through a portable analyzer (i-STAT*, Abbot, Illinois, USA) with cartridges (EG7+). These data were grouped in such a way as to present both mean and standard deviation: body weight (360±37g), respiratory rate (82±33 b/m), temperature (41.8±0.6°C), hydrogen potential (7.452±0.048), carbon dioxide partial pressure (22.1±4.0mmHg), oxygen partial pressure (98.1±7.6mmHg), base excess (-7.9±3.1), plasma concentration of bicarbonate ions (14.8±2.8mmol/L), oxygen saturation (96.2±1.1%), plasma concentration of sodium (147.4±2.2mmol/L), plasma concentration of potassium (3.5±0.53mmol/L), plasma concentration of calcium (0.8±0.28mmol/L), hematocrit (38.7±6.2%) and concentration of hemoglobin (13.2±2.1g/dl). This study led us to conclude that, although the results obtained showed hypocapnia and low values of bicarbonate and base excess, when compared to other avian species, these data are very similar. Besides, in spite of the equipment being approved only for human beings, it was considered simple and very useful in the analysis of avian blood samples. By using this equipment we were able to provide references data for non-anaesthetized Amazon parrots.
Resumo:
Hematological status in rainbow trout, Salmo gairdneri, was examined in relation to eight combinations of three environmental fa ctors; temperature (5°, 20°C), oxygen availability «35%, >70% saturation) and photoperiod (16L:8D, 8L:16D) and evaluated by 3-factor analysis of variance. Hemog l obin and hematocrit , indicators of oxygenc arrying capacity increased significantly at the higher temperature, following exposure to hypoxia and in relation to reduced light period. Significant variations in mean corpuscular hemoglobin concentration were not detected. The effects of temperature and oxygen availability were more pronounced than that of photoperiod which was generally masked. Although oxygen availability and photoperiod did not interact with temperature, the interaction of the former fac tors was significant. Elec trophoresis revealed twelve hemoglobin isomorphs. Relative concentration changes were found in re lation to the factors c onsidered with temperature>hypoxia>photoperiod. Howeve r , in terms of absolute concentration, effects were hypoxia>temperature>photoperiod. Photoperiod effects were again masked by temperature and (or) hypoxia. Red cell +2 l eve ls of [CI ] and [Mg ], critical elements in the hemoglobin-oxygen affinity regulating system, were also significantly altered. Red cell CI +2 was influenced only by temperature ; Mg by temper ature and oxygen. No photoperiod influence on either ions was observed. Under nominal 'summer' conditions, these changes point to the likelihood of increases in oxygen-c arrying c apac ity coupled with low Hb-02 affinity adjustments which would be expected to increase oxygen delivery rates to their more rapidly metabolising tissues.
Resumo:
Avaliou-se a pressão intra-ocular (PIO) e estimaram-se as correlações entre PIO e pressão de dióxido de carbono (PaCO2) e pH arterial de cinco caracarás (Caracara plancus), anestesiados com isofluorano (ISO) ou sevofluorano (SEV). Valores basais da PIO foram aferidos em ambos os olhos (M0). Cateterizou-se previamente a artéria braquial para obtenção de parâmetros hemogasométricos e cardiorrespiratórios. Anestesia foi induzida com ISO a 5V% e mantida por 40 minutos com 2,5V%. PIO e amostras de sangue foram avaliadas em diferentes momentos até o final do procedimento. Após recuperação, uma segunda anestesia foi realizada com SEV a 6% e mantida com 3,5%. Os parâmetros foram aferidos nos mesmos momentos estabelecidos previamente. A PIO decresceu significativamente (P=0,012) de M0 em todos os momentos e não houve diferença estatística entre ISO e SEV. Correlações significativas entre PIO e PaCO2 e entre PIO e pH sangüíneo foram observadas apenas para a anestesia com SEV. O pH sangüíneo decresceu paralelamente a PIO, enquanto a PaCO2 aumentou, em carcarás anestesiados com isofluorano e sevofluorano.
Resumo:
Objective To compare results reported for blood gas partial pressures, electrolyte concentrations, and Hct in venous blood samples collected from cattle, horses, and sheep and analyzed by use of a portable clinical analyzer (PCA) and reference analyzer (RA).Animals-Clinically normal animals (24 cattle, 22 horses, and 22 sheep).Procedures-pH; Pco(2); Po(2); total carbon dioxide concentration; oxygen saturation; base excess; concentrations of HCO(3)(-), Na(+), K(+), and ionized calcium; Hct; and hemoglobin concentration were determined with a PCA. Results were compared with those obtained for the same blood sample with an RA. Bias (mean difference) and variability (95% confidence interval) were determined for all data reported. Data were also subjected to analyses by Deming regression and Pearson correlation.Results-Analysis of Bland-Altman plots revealed good agreement between results obtained with the PCA and those obtained with the RA for pH and total carbon dioxide concentration in cattle, K(+) concentration in horses and sheep, and base excess in horses. Except for Na(+) concentration and Hct in horses and sheep, correlation was good or excellent for most variables reported.Conclusions and Clinical Relevance-Data from blood gas and electrolyte analyses obtained by use of the PCA can be used to evaluate the health status of cattle, horses, and sheep. Furthermore, the handheld PCA device may have a great advantage over the RA device as a result of the ability to analyze blood samples on farms that may be located far from urban centers. (Am J Vet Res 2010;71:515-521)
Resumo:
This study aimed to standardize signs and diagnostic criteria of respiratory function in newborn puppies delivered normally or after dystocia and caesarean operation. A total of 48 neonates were allocated into groups: eutocia (n = 20), dystocia (n = 8), caesarean (c)-section (n = 20). Neonatal health was assessed using the Apgar score and body temperature was determined at 0, 5 and 60 min after delivery. Venous blood gases (pO(2) and SO(2)) was measured immediately and 60 min after delivery, and a thoracic radiograph was made between 0 and 5 min of life. The c-section group had significantly lower Apgar scores at birth and 5 min. Hypothermia was present at 5 min in the eutocia and c-section groups, and at 60 min in all groups. The eutocia group had an irregular respiratory pattern in 78% of puppies at birth, 27.7% at 5 min and 21% at 60 min compared with 87.5%, 62.5% and 12.5% of the pups in the dystocia group where there was irregular respiratory rhythm, moderate to intense respiratory sounds with agonic episodes. The c-section group had respiratory alterations in 70%, 45% and 16% of puppies at 0, 5 and 60 min, respectively. Radiographic abnormalities were present in 17% of the pups in the eutocia group, 25% of the pups in the dystocia group and 30% of the pups in the c-section group, respectively. The c-section group had significantly lower SO(2) values at 60 min than at birth. All puppies had hypoxaemia, but a significant decrease was observed in the c-section group. Newborn puppies had tissue hypoxia and irregular respiratory pattern at birth. Caesarean-section puppies had lower vitality; however, all developed satisfactory Apgar scores at 5 min of life, regardless of the obstetric condition.
Resumo:
The development of the new TOGA (titration and off-gas analysis) sensor for the detailed study of biological processes in wastewater treatment systems is outlined. The main innovation of the sensor is the amalgamation of titrimetric and off-gas measurement techniques. The resulting measured signals are: hydrogen ion production rate (HPR), oxygen transfer rate (OTR), nitrogen transfer rate (NTR), and carbon dioxide transfer rate (CTR). While OTR and NTR are applicable to aerobic and anoxic conditions, respectively, HPR and CTR are useful signals under all of the conditions found in biological wastewater treatment systems, namely, aerobic, anoxic and anaerobic. The sensor is therefore a powerful tool for studying the key biological processes under all these conditions. A major benefit from the integration of the titrimetric and off-gas analysis methods is that the acid/base buffering systems, in particular the bicarbonate system, are properly accounted for. Experimental data resulting from the TOGA sensor in aerobic, anoxic, and anaerobic conditions demonstrates the strength of the new sensor. In the aerobic environment, carbon oxidation (using acetate as an example carbon source) and nitrification are studied. Both the carbon and ammonia removal rates measured by the sensor compare very well with those obtained from off-line chemical analysis. Further, the aerobic acetate removal process is examined at a fundamental level using the metabolic pathway and stoichiometry established in the literature, whereby the rate of formation of storage products is identified. Under anoxic conditions, the denitrification process is monitored and, again, the measured rate of nitrogen gas transfer (NTR) matches well with the removal of the oxidised nitrogen compounds (measured chemically). In the anaerobic environment, the enhanced biological phosphorus process was investigated. In this case, the measured sensor signals (HPR and CTR) resulting from acetate uptake were used to determine the ratio of the rates of carbon dioxide production by competing groups of microorganisms, which consequently is a measure of the activity of these organisms. The sensor involves the use of expensive equipment such as a mass spectrometer and requires special gases to operate, thus incurring significant capital and operational costs. This makes the sensor more an advanced laboratory tool than an on-line sensor. (C) 2003 Wiley Periodicals, Inc.
Resumo:
The two steps of nitrification, namely the oxidation of ammonia to nitrite and nitrite to nitrate, often need to be considered separately in process studies. For a detailed examination, it is desirable to monitor the two-step sequence using online measurements. In this paper, the use of online titrimetric and off-gas analysis (TOGA) methods for the examination of the process is presented. Using the known reaction stoichiometry, combination of the measured signals (rates of hydrogen ion production, oxygen uptake and carbon dioxide transfer) allows the determination of the three key process rates, namely the ammonia consumption rate, the nitrite accumulation rate and the nitrate production rate. Individual reaction rates determined with the TOGA sensor under a number of operation conditions are presented. The rates calculated directly from the measured signals are compared with those obtained from offline liquid sample analysis. Statistical analysis confirms that the results from the two approaches match well. This result could not have been guaranteed using alternative online methods. As a case study, the influences of pH and dissolved oxygen (DO) on nitrite accumulation are tested using the proposed method. It is shown that nitrite accumulation decreased with increasing DO and pH. Possible reasons for these observations are discussed. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
The European Prospective Investigation into Cancer and nutrition (EPIC) is a long-term, multi-centric prospective study in Europe investigating the relationships between cancer and nutrition. This study has served as a basis for a number of Genome-Wide Association Studies (GWAS) and other types of genetic analyses. Over a period of 5 years, 52,256 EPIC DNA samples have been extracted using an automated DNA extraction platform. Here we have evaluated the pre-analytical factors affecting DNA yield, including anthropometric, epidemiological and technical factors such as center of subject recruitment, age, gender, body-mass index, disease case or control status, tobacco consumption, number of aliquots of buffy coat used for DNA extraction, extraction machine or procedure, DNA quantification method, degree of haemolysis and variations in the timing of sample processing. We show that the largest significant variations in DNA yield were observed with degree of haemolysis and with center of subject recruitment. Age, gender, body-mass index, cancer case or control status and tobacco consumption also significantly impacted DNA yield. Feedback from laboratories which have analyzed DNA with different SNP genotyping technologies demonstrate that the vast majority of samples (approximately 88%) performed adequately in different types of assays. To our knowledge this study is the largest to date to evaluate the sources of pre-analytical variations in DNA extracted from peripheral leucocytes. The results provide a strong evidence-based rationale for standardized recommendations on blood collection and processing protocols for large-scale genetic studies.
Resumo:
The Earlobe Arterialized Blood Collector® is a minimally invasive system able to perform arterialized capillary blood gas analysis from the earlobe (EL). A prospective validation study was performed in 55 critical ill patients. Sampling failure rate was high (53.6%). Risk factors were age > 65 years, diabetes, vasoactive drug therapy and noradrenaline (NA) doses above 0.22 μg / kg / min. Multivariate analysis showed age > 65 years was the only factor independently associated with failure. Concordance analysis with arterial blood gases and Bland-Altman agreement evaluation were insufficient for validating the new system for all gasometrical variables.