983 resultados para Blood -- Circulation, Artificial
Resumo:
Until recently, the low-abundance (LA) range of the serum proteome was an unexplored reservoir of diagnostic information. Today it is increasingly appreciated that a diagnostic goldmine of LA biomarkers resides in the blood stream in complexed association with more abundant higher molecular weight carrier proteins such as albumin and immunoglobulins. As we now look to the possibility of harvesting these LA biomarkers more efficiently through engineered nano-scale particles, mathematical approaches are needed in order to reveal the mechanisms by which blood carrier proteins act as molecular 'mops' for LA diagnostic cargo, and the functional relationships between bound LA biomarker concentrations and other variables of interest such as biomarker intravasation and clearance rates and protein half-lives in the bloodstream. Here we show, by simple mathematical modeling, how the relative abundance of large carrier proteins and their longer half-lives in the bloodstream work together to amplify the total blood concentration of these tiny biomarkers. The analysis further suggests that alterations in the production of biomarkers lead to gradual rather than immediate changes in biomarker levels in the blood circulation. The model analysis also points to the characteristics of artificial nano-particles that would render them more efficient harvesters of tumor biomarkers in the circulation, opening up possibilities for the early detection of curable disease, rather than simply better detection of advanced disease.
Resumo:
The clinical importance of pulsatility is a recurring topic of debate in mechanical circulatory support. Lack of pulsatility has been identified as a possible factor responsible for adverse events and has also demonstrated a role in myocardial perfusion and cardiac recovery. A commonly used method for restoring pulsatility with rotodynamic blood pumps (RBPs) is to modulate the speed profile, synchronized to the cardiac cycle. This introduces additional parameters that influence the (un)loading of the heart, including the timing (phase shift) between the native cardiac cycle and the pump pulses, and the amplitude of speed modulation. In this study, the impact of these parameters upon the heart-RBP interaction was examined in terms of the pressure head-flow (HQ) diagram. The measurements were conducted using a rotodynamic Deltastream DP2 pump in a validated hybrid mock circulation with baroreflex function. The pump was operated with a sinusoidal speed profile, synchronized to the native cardiac cycle. The simulated ventriculo-aortic cannulation showed that the level of (un)loading and the shape of the HQ loops strongly depend on the phase shift. The HQ loops displayed characteristic shapes depending on the phase shift. Increased contribution of native contraction (increased ventricular stroke work [WS ]) resulted in a broadening of the loops. It was found that the previously described linear relationship between WS and the area of the HQ loop for constant pump speeds becomes a family of linear relationships, whose slope depends on the phase shift.
Resumo:
The shortage of donor hearts for patients with end stage heart failure has accelerated the development of ventricular assist devices (VAD) that act as a replacement heart. Mechanical devices involving pulsatile, axial and centrifugal devices have been proposed. Recent clinical developments indicate that centrifugal devices are not only beneficial for bridge to transplantation applications, but may also aid myocardial recovery. The results of a recent study have shown that patients who received a VAD have extended lives and improved quality of life compared to recipients of drug therapy. Unfortunately 25% of these patients develop right heart failure syndrome, sepsis and multi-organ failure. It was reported that 17% of patients initially receiving an LVAD later required a right ventricular assist device (RVAD). Hence, current research focus is in the development of a bi-ventricular assist device (BVAD). Current BVAD technology is either too bulky or necessitates having to implant two pumps working independently. The latter requires two different controllers for each pump leading to the potential complication of uneven flow dynamics and the requirements for a large amount of body space. This paper illustrates the combination of the LVAD and RVAD as one complete device to augment the function of both the left and right cardiac chambers with double impellers. The proposed device has two impellers rotating in counter directions, hence eliminating the necessity of the body muscles and tubing/heart connection to restrain the pump. The device will also have two separate chambers with independent rotating impeller for the left and right chambers. A problem with centrifugal impellers is the fluid stagnation underneath the impeller. This leads to thrombosis and blood clots.This paper presents the design, construction and location of washout hole to prevent thrombus for a Bi-VAD centrifugal pump. Results using CFD will be used to illustrate the superiority of our design concept in terms of preventing thrombus formation and hemolysis.
Resumo:
Major problems with the treatment of osteomyelitis are associated with poor antibiotic distribution at the site of infection due to limited blood circulation to the skeletal tissue. Improved treatment procedures have been used in drug delivery systems that include bioceramics and natural and synthetic polymers. This work reports the development of anionic collagen:hydroxyapatite composite paste for sustained antibiotic release. Antibiotic release by the composite was characterized by two steps. In the first, 15.0 +/- 4.9% was released in the first 5 h (n = 53) by a normal Fick diffusion mechanism. In the second step, only 16.8 +/- 2.2% was released after 7 days. In conclusion, hydroxyapatite:anionic collagen composite can be an efficient support for sustained antibiotic release in the treatment of osteomyelitis because most of the antibiotic release may be associated with composite bioresorption, thus permitting antibiotic release throughout the healing process. Hydroxyapatite:anionic collagen paste showed good biocompatibility associated with bone tissue growth with material still being observed after 60 days from the time of implants.
Resumo:
The localization of peroxidase activity in different cell regions is used as a criterion for classifying the stage of maturity of mammalian mononuclear phagocytes, with a positive peroxidase reaction indicating the presence of monoblasts, promonocytes, monocytes, and macrophages. Peroxidase activity was observed ultrastructurally in the circulating blood of pacu fish (Piaractus mesopotamicus), identifying monoblasts, promonocytes, monocytes, and macrophages. These observations suggest that differentiation of mononuclear phagocytes occurs in the blood circulation of fish, whereas in mammals, monoblasts and promonocytes are detected in bone marrow, with only monocytes detected in circulating blood and differentiation into macrophages occurring in other body compartments.
Resumo:
The localization of peroxidase activity in different cell regions is used as a criterion for the classification of the stage of maturation of mammalian mononuclear phagocytes with a positive peroxidase reaction indicating the presence of monoblasts, promonocytes, monocytes and macrophages. In this study it was evaluated the peroxidase activity of blood mononuclear phagocytes of this turtle detected at different stages of differentiation. The present observations suggest that, in turtles, the differentiation of mononuclear phagocytes occur in the blood circulation, in contrast to animals, where only are monocytes in circulating blood and macrophage differentiation occurs in other body compartments. © 2007 Sociedad Chilena de Anatomía.
Resumo:
Os objetos do trabalho foram: 1) realizar a ecobiometria do concepto para acompanhar o crescimento fetal e determinar a idade gestacional em Cebus apella; 2) descrever o momento em que os órgãos do feto são observados; 3) realizar a sexagem fetal; 4) avaliar o fluxo sanguíneo das artérias uterinas (AU) e umbilical (Aum), mensurando os índices de resistividade (IR) e pulsatilidade (IP); 5) observar a presença ou ausência da incisura protodiastólica (IPD) e do componente diastólico nas ondas de fluxo sanguíneo das AU e Aum, respectivamente, durante a gestação em C. apella. Seis fêmeas adultas da espécie C. apella foram selecionadas e, posteriormente, condicionadas para os procedimentos de colpocitologia ou contenção química. Para o monitoramento do ciclo reprodutivo das fêmeas e crescimento folicular, foram realizados exames colpocitológicos e ultrassonografia (US), respectivamente, para a escolha do melhor dia da monta natural ou inseminação artificial. Vinte dias após a cópula ou inseminação, era realizado o diagnóstico da gestação por meio da US. O dia de cada exame em relação ao parto foi contado em retrospecto (nascimento = dia 0). Os exames ultrassonográficos foram feitos nos dias -133, -113, -83, -53, -21 e -1 antes do parto. A US bidimensional em modo B foi utilizada para mensurar o saco gestacional do dia - 133 até -113; os diâmetros biparietal, fronto-occiptal, circunferência da cabeça e circunferência abdominal do dia -113 a -1; e comprimento do fêmur do dia -53 até -23, mostrando o aumento desses parâmetros com o avanço da gestação. O coração e o estômago começaram a ser visualizados no dia -113 e, os demais órgãos e a sexagem no dia -83. O Triplex Doppler foi empregado para avaliar o fluxo sanguíneo durante o período gestacional, mostrando uma diminuição nos IR e IP das AU e Aum, do dia -133 a -1, bem como observar o desaparecimento da IPD (dia -1) e aparecimento do componente diastólico (dia -53) na onda de fluxo sanguíneo das AU e Aum, respectivamente. Entre os dias -113 a -1, a média da freqüência cardíaca fetal, obtida pelo Triplex Doppler, foi de 189 ± 2,43 bpm. O presente trabalho permitiu determinar a idade gestacional, avaliar o crescimento anatômico do feto, descrever o momento em que os órgãos são visualizados e realizar a sexagem em C. apella. Constatou-se, também, que o fluxo sanguíneo das AU e Aum são importantes parâmetros para avaliar a vitalidade fetal em C. apella.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Abstract Background While it is well known that bradykinin B2 agonists increase plasma protein extravasation (PPE) in brain tumors, the bradykinin B1 agonists tested thus far are unable to produce this effect. Here we examine the effect of the selective B1 agonist bradykinin (BK) Sar-[D-Phe8]des-Arg9BK (SAR), a compound resistant to enzymatic degradation with prolonged activity on PPE in the blood circulation in the C6 rat glioma model. Results SAR administration significantly enhanced PPE in C6 rat brain glioma compared to saline or BK (p < 0.01). Pre-administration of the bradykinin B1 antagonist [Leu8]-des-Arg (100 nmol/Kg) blocked the SAR-induced PPE in the tumor area. Conclusions Our data suggest that the B1 receptor modulates PPE in the blood tumor barrier of C6 glioma. A possible role for the use of SAR in the chemotherapy of gliomas deserves further study.
Resumo:
In this study, the effect of time derivatives of flow rate and rotational speed was investigated on the mathematical modeling of a rotary blood pump (RBP). The basic model estimates the pressure head of the pump as a dependent variable using measured flow and speed as predictive variables. Performance of the model was evaluated by adding time derivative terms for flow and speed. First, to create a realistic working condition, the Levitronix CentriMag RBP was implanted in a sheep. All parameters from the model were physically measured and digitally acquired over a wide range of conditions, including pulsatile speed. Second, a statistical analysis of the different variables (flow, speed, and their time derivatives) based on multiple regression analysis was performed to determine the significant variables for pressure head estimation. Finally, different mathematical models were used to show the effect of time derivative terms on the performance of the models. In order to evaluate how well the estimated pressure head using different models fits the measured pressure head, root mean square error and correlation coefficient were used. The results indicate that inclusion of time derivatives of flow and speed can improve model accuracy, but only minimally.