1000 resultados para Blood typing
Resumo:
In medical emergency situations, when a patient needs a blood transfusion, the universal blood type O is administered. This procedure may lead to the depletion of stock reserves of O blood. Nowadays, there is no commercial equipment capable of determining the patient's blood type in situ, in a fast and reliable process. Human blood typing is usually performed through the manual test, which involves a macroscopic observation and interpretation of the results by an analyst. This test, despite of having a fast response time, may lead to human errors, which sometimes can be fatal to the patient. This paper presents the development of an automatic mechatronic prototype for determining human blood typing (ABO and Rh systems) through image processing techniques. The prototype design takes into account the characteristics of reliability of analysis, portability, and response time allowing the system to be used in emergency situations. The developed prototype performs blood and reagents mixture acquires the resultant image and processes the data (based on image processing techniques) to determine the sample blood type. It was tested in a laboratory, using cataloged samples of blood types, provided by the Portuguese Institute of Blood and Transplantation. Hereafter, it is expected to test and validate the prototype in clinical environments.
Resumo:
Blood typing is a crucial step before any blood transfusion. However, sometimes in emergency situations there is no time to determine the blood of the patient beforehand. In this cases, O negative blood type is administered, which has a lesser incompatibility risk to the patient. Nowadays, the gold standard blood typing devices cannot be used in emergency situations due to their high response time (about 30 minutes). This paper reports a blood typing device that determines the ABO and Rh human phenotypes. This device is fast (response time 5 min), low-cost, and portable. Characteristics that make it suitable to be used in emergency situations, contributing to a higher efficiency and quality in healthcare.
Resumo:
The authors investigated the relationship between dermatophytosis and ABO blood groups through blood typing, identification of isolated dermatophytes and specific cellular immune response of 40 individuals carriers of this mycosis. They verified that the fungus Trichophyton rubrum, isolated from 54.5% of the patients, was more frequent in individuals belonging to blood group A. The cellular immune response, evaluated through the trichophytin antigen, was positive in 25% of the studied patients; the presence of immediate reactions (30 minutes) was verified in 35%. The blood group distribution among patients with dermatophytosis and control groups was, respectively: 47.5% X 36% in group A, 40% X 50% in group O, 12.5% X 11% in group B. Even though the authors have found a higher number of patients belonging to blood group A infected by T. rubrum, these results suggest that there is no statistical evidence that these individuals are more susceptible to dermatophytosis.
Resumo:
The study of canine immunohematology is very important for veterinary transfusion medicine. The objective of this study was to determine the DEA blood type frequencies in a purebred canine blood donor population from Porto Alegre, RS, Brazil. One hundred clinically healthy purebred dogs were chosen, 20 dogs from each breed (Great Dane, Rottweiler, Golden Retriever, German Shepherd and Argentine Dogo). Blood samples were taken in ACD-A tubes and the MSU hemagglutination tube test (MI, USA) was used to determine the blood types. The studied population presented general frequencies of 61% for DEA 1.1, 22% for DEA 1.2, 7% for DEA 3, 100% for DEA 4, 9% for DEA 5 and 16% for DEA 7. A significant association was found between breeds and certain combinations of blood types in this population. The results are in agreement with the literature since most part of the canine population studied was positive for DEA 1.1, the most antigenic blood type in dogs. Differences were found among the studied breeds and those should be considered when selecting a blood donor. The knowledge of blood types frequencies and their combinations in different canine populations, including different breeds, is important because it shows the particularities of each group, helps to keep a data bank of local frequencies and minimizes the risks of transfusion reactions.
Resumo:
Os autores investigaram a relao entre dermatofitose e grupo sanguneo ABO atravs da tipagem sangunea, identificao do dermatfito isolado e resposta imune celular especfica de 40 indivduos portadores desta micose. Verificaram que o fungo Trichophyton rubrum foi isolado em 54,5% dos pacientes, sendo mais frequente em indivduos pertencentes ao grupo sanguneo A. A resposta imune celular, avaliada atravs do antgeno tricofitina, foi positiva em 25% dos pacientes estudados; a presena de reaes imediatas (30 min) foi verificada em 35%. A distribuio dos grupos sanguneos entre pacientes com dermatofitose e grupo controle foi a seguinte: 47,5% x 36% grupo A, 40% x 50% grupo O, 12,5% x 11% grupo B. Embora os autores tenham encontrado um nmero maior de pacientes pertencentes ao grupo sanguneo A e infectados pelo T. rubrum, no obtiveram evidncia estatstica de que esses indivduos sejam mais suscetveis as dermatofitoses.
Resumo:
Os avanos na rea da Medicina transfucional, nomeadamente a descoberta de nova informao sobre os grupos sanguneos de vrias espcies, a introduo rotineira da tipificao sangunea e das provas de compatibilidade eritrocitria, o estudo das reaces transfusionais adversas, o despiste de doenas infeciosas no dador e a aplicao da terapia por componentes, tm contribudo para aumentar a segurana da transfuso sangunea em Medicina Veterinria e, por consequncia, a sua utilizao cada vez mais frequente. O presente trabalho constitudo por trs objectivos: perspectivar a medicina transfusional em Portugal atravs da anlise dos resultados de um inqurito, dirigido aos CAMV, nomeadamente sobre o uso da terapia por componentes, as principais indicaes de transfuso e a ocorrncia de reaces transfusionais; caracterizar a populao de gatos e ces receptores de transfuses sanguneas, com enfoque na prevalncia dos diferentes grupos sanguneos, na indicao para a realizao da transfuso e tipo de produto administrado; determinar a ocorrncia de reaces transfusionais atravs da monotorizao do doente antes, durante e aps a administrao das transfuses. No presente estudo, 86% dos Centros de Atendimento Mdico Veterinrio (CAMV) inquiridos recorrem transfuso sangunea como terapia complementar. Destes, 54.7% utiliza sangue total e produtos do sangue, 41.3% apenas sangue total e 4% apenas produtos do sangue. Os produtos do sangue mais utilizados so o concentrado de glbulos vermelhos e o plasma fresco congelado (34.2% e 31.6% respectivamente). A anemia constitui o principal motivo para a realizao de transfuses sanguneas e a hipertermia a reaco transfusional mais frequente. Relativamente caracterizao da populao de ces e gatos que receberam transfuso sangunea conclui-se que 77.8% dos ces pertenciam ao grupo DEA 1.1 negativo e 22.2% ao grupo DEA 1.1 positivo. Todos os gatos includos neste estudo pertenciam ao grupo sanguneo A. A anemia por hemorragia foi a indicao predominante para a administrao de sangue nos ces (54.3%). Nos gatos a anemia por no produo de eritrcitos prevalece (60%). No que respeita s reaces transfusionais, das 61 transfuses realizadas apenas se registou uma dispneia num gato.
Resumo:
Background: In human medicine, transfusion of ABO-mismatched platelets has been associated with shortened platelet survival and refractoriness to platelet transfusion because of expression of certain blood group antigens on platelets. It remains unknown if canine platelets express dog erythrocyte antigens (DEAs). Objective: The aim of this study was to develop a flow cytometric assay for DEA 1.1 and determine whether DEA 1.1 is present on canine platelets.Methods: Blood was collected from 172 clinically healthy dogs. Platelets and erythrocytes from each dog were tested for DEA 1.1 by flow cytometry using anti-DEA 1.1 blood-typing sera. Erythrocytes from each dog were also assessed for DEA 1.1 using a standard tube-typing test (T1) and using a second tube method (T2), if the flow cytometric and T1 results differed.Results: Using flow cytometry, DEA 1.1 was detected on erythrocytes of all 110 dogs shown by T1 or T2 testing to be DEA 1.1-positive. Initial results of the T1 test had a diagnostic accuracy of 93% (160 correct/ 172 tests). The frequency of erythrocyte DEA 1.1 positivity in previously untyped dogs (n = 118) was 56%. DEA 1.1 expression was not detected on platelets from DEA 1.1-positive dogs.Conclusions: Flow cytometry was a reliable method for detection of DEA 1.1 on canine erythrocytes. The absence of DEA 1.1 on platelets from DEA 1.1-positive dogs suggests that their platelets do not express DEA 1.1 and will not induce production of anti-DEA 1.1 antibodies that might lead to platelet refractoriness or reactions to a subsequent transfusion of DEA 1.1positive erythrocytes.
Resumo:
Ps-graduao em Pesquisa e Desenvolvimento (Biotecnologia Mdica) - FMB
ALTERNATING CURRENT DIELECTROPHORETIC MANIPULATION OF ERYTHROCYTES IN MEDICAL MICRODEVICE TECHNOLOGY
Resumo:
Medical microdevices have gained popularity in the past few decades because they allow the medical laboratory to be taken out into the field and for disease diagnostics to happen with a smaller sample volume, at a lower cost and much faster. Blood is the human body's most readily available and informative diagnostic fluid because of the wealth of information it provides about the body's general health including enzymatic, proteomic and immunological states. The purpose of this project is to optimize operating conditions and study ABO-Rh erythrocytes dielectrophoretic responses to alternating current electric signals. The end goal of this project is the creation of a relatively inexpensive microfluidic device, which can be used for the ABO-Rh typing of a blood sample. This dissertation presents results showing how blood samples of a known ABO- Rh blood type exhibit differing behavior to the same electrical stimulus based on their blood type. The first panel of donors and experiments, presented in Chapter 4 occurred when a sample of known blood type was injected into a microdevice with a T-shaped electrode configuration and the erythorcytes were found to rupture at a rate specific to their ABO-Rh blood type. The second set of experiments, presented in Chapter 5, were originally published in Electrophoresis in 20111. Novel in this work was the discovery that treatment of human erythrocytes with -galactosidase successfully removed ABO surface antigens such that native A and B blood no longer agglutinated with the proper antibodies. This work was performed in a medium of conductivity 0.9S/m which is close to the measured conductivity of pooled plasma (~1.1S/m). The ability to perform dielectrophoresis experiments at physiological conductivities conditions is advantageous for future portable devices because the device/instrument would not need to store dilution buffers. The final results of this project, presented in Chapter 6, explore the entire dielectrophoretic spectra of the ABO-Rh erythrocytes including the cross-over frequency and the magnitudes of the positive or negative dielectrophoretic response. These were completed at lower medium conductivities of 0.1S/m and 0.01-0.04S/m. These results show that by using the sweep function built into the Agilent alternating current generator it is possible to explore how a single group of blood cells will react to rapid changes in frequency and will provide the user with curve that can be matched the theoretical dielectrophoretic response curves. As a whole this project shows that it is possible to distinguish human erythrocytes by their ABO-Rh blood type via three different dielectrophoretic methods. This work builds on the foundation of that it is possible to distinguish healthy from infected cells2-7, similar cell types1,7-14 and other work regarding the dielectrophoresis of human erythrocytes1,10,11. This work has implications in both medical diagnostics and future dielectrophoretic work because it has shown that ABO-Rh blood type is now a factor, which must be identified when working with a human blood sample. It also shows that the creation of a microfluidic device that subjects human erythrocytes to a dielectrophoretic impulse and then exports an ABO-Rh blood type is a near future possibility.
Resumo:
Yeasts of the genus Candida have been recognized as important microorganisms responsible for nosocomial fungemia. Six blood-stream and two intravenous central catheter C. albicans strains were isolated from eight patients and studied by electrophoretic karyotyping of chromosomal DNA by pulsed-field gel electrophoresis. Seven chromosomal DNA profiles were identified. Two patients showed isolates with the same profile, suggesting nosocomial transmission. Karyotyping of C. albicans revealed an excellent discriminatory power among the isolates and may therefore be useful in the study of nosocomial candidemia.
Resumo:
SUMMARYIntroduction: The majority of nosocomial fungal infections are caused by Candida spp. where C. albicans is the species most commonly identified. Molecular methods are important tools for assessing the origin of the yeasts isolated in hospitals.Methods: This is a study on the genetic profifiles of 39 nosocomial clinical isolates of C. albicans using two typing methods: random amplifified polymorphic DNA (RAPD) and microsatellite, two different primers for each technique were used.Results: RAPD provided 10 and 11 different profiles with values for SAB of 0.84 0.126 and 0.88 0.08 for primers M2 and P4, respectively. Microsatellite using two markers, CDC3 and HIS3, allowed the observation of six and seven different alleles, respectively, with combined discriminatory power of 0.91.Conclusions: Although genetic variability is clear, it was possible to identify high similarity, suggesting a common origin for at least a part of isolates. It is important to emphasize that common origin was proven from yeasts isolated from colonization (urine, catheter or endotracheal secretions) and blood culture from the same patient, indicating that the candidemia must have started from a site of colonization. The combination of RAPD and microsatellite provides a quick and efficient analysis for investigation of similarity among nosocomial isolates of C. albicans.
Resumo:
This study had the objective of to analyze the demographic and bacteriologic data of 32 hospitalized newborns in an neonatal intensive care unit of a public maternity hospital in Rio de Janeiro city, Brazil, seized by Pseudomonas aeruginosa sepsis during a period ranged from July 1997 to July 1999, and to determine the antimicrobial resistance percentage, serotypes and pulsed field gel electrophoresis (PFGE) patterns of 32 strains isolated during this period. The study group presented mean age of 12.5 days, with higher prevalence of hospital infection in males (59.4%) and vaginal delivery (81.2%), than females (40.6%) and cesarean delivery (18.8%), respectively. In this group, 20 (62.5%) patients received antimicrobials before positive blood cultures presentation. A total of 87.5% of the patients were premature, 62.5% presented very low birth weight and 40.6% had asphyxia. We detected high antimicrobial resistance percentage to b-lactams, chloramphenicol, trimethoprim/sulfamethoxazole and tetracycline among the isolated strains. All isolated strains were classified as multi-drug resistant. Most strains presented serotype O11 while PFGE analysis revealed seven distinct clones with isolation predominance of a single clone (75%) isolated from July 1997 to June 1998.
Resumo:
Methicillin-resistant Staphylococcus remains a severe public health problem worldwide. This research was intended to identify the presence of methicillin-resistant coagulase-negative staphylococci clones and their staphylococcal cassette chromosome mec (SCCmec)-type isolate from patients with haematologic diseases presenting bacterial infections who were treated at the Blood Bank of the state of Amazonas in Brazil. Phenotypic and genotypic tests, such as SCCmec types and multilocus sequence typing (MLST), were developed to detect and characterise methicillin-resistant isolates. A total of 26 Gram-positive bacteria were isolated, such as: Staphylococcus epidermidis (8/27), Staphylococcus intermedius (4/27) and Staphylococcus aureus (4/27). Ten methicillin-resistant staphylococcal isolates were identified. MLST revealed three different sequence types: S. aureus ST243, S. epidermidis ST2 and a new clone of S. epidermidis, ST365. These findings reinforce the potential of dissemination presented by multi-resistant Staphylococcus and they suggest the introduction of monitoring actions to reduce the spread of pathogenic clonal lineages of S. aureus and S. epidermidis to avoid hospital infections and mortality risks.
Resumo:
Mycobacterium avium is an important pathogen among immunodeficient patients, especially patients with AIDS. The natural history of this disease is unclear. Several environmental sources have been implicated as the origin of this infection. Polyclonal infection with this species is observed, challenging the understanding of its pathogenesis and treatment. In the present study 45 M. avium strains were recovered from 39 patients admitted to a reference hospital between 1996 and 1998. Species identification was performed using a species-specific nucleic acid hybridization test (AccuProbe) from Gen-Probe. Strains were genotyped using IS1245 restriction fragment length polymorphism typing. Blood was the main source of the organism. In one patient with disseminated disease, M. avium could be recovered more than once from potentially sterile sites. Strains isolated from this patient had different genotypes, indicating that the infection was polyclonal. Four patient clones were characterized in this population, the largest clone being detected in eight patients. This finding points to a common-source transmission of the organism.
Resumo:
In order to detect several new HLA-A class I alleles that have been described since 1998, the original PCR-RFLP method developed to identify the 78 alleles recognized at that time at high resolution level was adapted by us for low and medium resolution levels using a nested PCR-RFLP approach. The results obtained from blood samples of 23 subjects using both the PCR-RFLP method and a commercial kit (MicroSSP1A, One Lambda Inc.) showed an agreement higher than 95%. The PCR-RFLP adapted method was effective in low and medium resolution histocompatibility evaluations.