910 resultados para Bland and Altman method
Resumo:
Purpose: Revolutionary endovascular treatments are on the verge of being available for management of ascending aortic diseases. Morphometric measurements of the ascending aorta have already been done with ECG-gated MDCT to help such therapeutic development. However the reliability of these measurements remains unknown. The objective of this work was to compare the intraobserver and interobserver variability of CAD (computer aided diagnosis) versus manual measurements in the ascending aorta. Methods and materials: Twenty-six consecutive patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters at mid-distance between the brachiocephalic artery and the aortic valve were obtained automatically with a commercially available CAD and manually by two observers separately. Both observers repeated the measurements during a different session at least one month after the first measurements. Intraclass coefficients as well the Bland and Altman method were used for comparison between measurements. Two-paired t-test was used to determine the significance of intraobserver and interobserver differences (alpha = 0.05). Results: There is a significant difference between CAD and manual measurements in the maximum diameter (p = 0.004) for the first observer, whereas the difference was significant for minimum diameter between the second observer and the CAD (p <0.001). Interobserver variability showed a weak agreement when measurements were done manually. Intraobserver variability was lower with the CAD compared to the manual measurements (limits of variability: from -0.7 to 0.9 mm for the former and from -1.2 to 1.3 mm for the latter). Conclusion: In order to improve reproductibility of measurements whenever needed, pre- and post-therapeutic management of the ascending aorta may benefit from follow-up done by a unique observer with the help of CAD.
Resumo:
Purpose: Recently morphometric measurements of the ascending aorta have been done with ECG-gated MDCT to help the development of future endovascular therapies (TCT) [1]. However, the variability of these measurements remains unknown. It will be interesting to know the impact of CAD (computer aided diagnosis) with automated segmentation of the vessel and automatic measurements of diameter on the management of ascending aorta aneurysms. Methods and Materials: Thirty patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters were obtained automatically with a commercially available CAD and semi-manually by two observers separately. The CAD algorithms segment the iv-enhanced lumen of the ascending aorta into perpendicular planes along the centreline. The CAD then determines the largest and the smallest diameters. Both observers repeated the automatic measurements and the semimanual measurements during a different session at least one month after the first measurements. The Bland and Altman method was used to study the inter/intraobserver variability. A Wilcoxon signed-rank test was also used to analyse differences between observers. Results: Interobserver variability for semi-manual measurements between the first and second observers was between 1.2 to 1.0 mm for maximal and minimal diameter, respectively. Intraobserver variability of each observer ranged from 0.8 to 1.2 mm, the lowest variability being produced by the more experienced observer. CAD variability could be as low as 0.3 mm, showing that it can perform better than human observers. However, when used in nonoptimal conditions (streak artefacts from contrast in the superior vena cava or weak lumen enhancement), CAD has a variability that can be as high as 0.9 mm, reaching variability of semi-manual measurements. Furthermore, there were significant differences between both observers for maximal and minimal diameter measurements (p<0.001). There was also a significant difference between the first observer and CAD for maximal diameter measurements with the former underestimating the diameter compared to the latter (p<0.001). As for minimal diameters, they were higher when measured by the second observer than when measured by CAD (p<0.001). Neither the difference of mean minimal diameter between the first observer and CAD nor the difference of mean maximal diameter between the second observer and CAD was significant (p=0.20 and 0.06, respectively). Conclusion: CAD algorithms can lessen the variability of diameter measurements in the follow-up of ascending aorta aneurysms. Nevertheless, in non-optimal conditions, it may be necessary to correct manually the measurements. Improvements of the algorithms will help to avoid such a situation.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
PURPOSE: We determined and compared urethral pressure measurements using air charged and microtip catheters in a prospective, single-blind, randomized trial. MATERIALS AND METHODS: A consecutive series of 64 women referred for urodynamic investigation underwent sequential urethral pressure measurements using an air charged and a microtip catheter in randomized order. Patients were blinded to the type and sequence of catheter used. Agreement between the 2 catheter systems was assessed using the Bland and Altman 95% limits of agreement method. RESULTS: Intraclass correlation coefficients of air charged and microtip catheters for maximum urethral closure pressure at rest were 0.97 and 0.93, and for functional profile length they were 0.9 and 0.78, respectively. Pearson's correlation coefficients and Lin's concordance coefficients of air charged and microtip catheters were r = 0.82 and rho = 0.79 for maximum urethral closure pressure at rest, and r = 0.73 and rho = 0.7 for functional profile length, respectively. When applying the Bland and Altman method, air charged catheters gave higher readings than microtip catheters for maximum urethral closure pressure at rest (mean difference 7.5 cm H(2)O) and functional profile length (mean difference 1.8 mm). There were wide 95% limits of agreement for differences in maximum urethral closure pressure at rest (-24.1 to 39 cm H(2)O) and functional profile length (-7.7 to 11.3 mm). CONCLUSIONS: For urethral pressure measurement the air charged catheter is at least as reliable as the microtip catheter and it generally gives higher readings. However, air charged and microtip catheters cannot be used interchangeably for clinical purposes because of insufficient agreement. Hence, clinicians should be aware that air charged and microtip catheters may yield completely different results, and these differences should be acknowledged during clinical decision making.
Resumo:
The aim of this study was to compare the performance of the DIAGNOdent 2095 with visual examination for occlusal caries detection in permanent and primary molars. The sample comprised 148 permanent human molars and 179 primary human molars. The samples were measured and visually examined three times by two examiners. After measurement, the teeth were histologically prepared and assessed for caries extension. Sensitivity, specificity, accuracy and area under the receiver operating characteristics (ROC) curve were calculated. Intra-class correlation (ICC), unweighted kappa and the Bland and Altman method were used to assess inter- and intra-examiner reproducibility. DIAGNOdent showed higher specificity and lower sensitivity than did visual examination. The ICC values indicated an excellent agreement between the examinations. Kappa values varied from good to excellent for DIAGNOdent but from poor to good for visual examination. In conclusion, the DIAGNOdent may be a useful adjunct to conventional methods for occlusal caries detection.
Resumo:
QUESTION UNDER STUDY: Purpose was to validate accuracy and reliability of automated oscillometric ankle-brachial (ABI) measurement prospectively against the current gold standard of Doppler-assisted ABI determination. METHODS: Oscillometric ABI was measured in 50 consecutive patients with peripheral arterial disease (n = 100 limbs, mean age 65 +/- 6 years, 31 men, 19 diabetics) after both high and low ABI had been determined conventionally by Doppler under standardised conditions. Correlation was assessed by linear regression and Pearson product moment correlation. Degree of inter-modality agreement was quantified by use of Bland and Altman method. RESULTS: Oscillometry was performed significantly faster than Doppler-assisted ABI (3.9 +/- 1.3 vs 11.4 +/- 3.8 minutes, P <0.001). Mean readings were 0.62 +/- 0.25, 0.70 +/- 0.22 and 0.63 +/- 0.39 for low, high and oscillometric ABI, respectively. Correlation between oscillometry and Doppler ABI was good overall (r = 0.76 for both low and high ABI) and excellent in oligo-symptomatic, non-diabetic patients (r = 0.81; 0.07 +/- 0.23); it was, however, limited in diabetic patients and in patients with critical limb ischaemia. In general, oscillometric ABI readings were slightly higher (+0.06), but linear regression analysis showed that correlation was sustained over the whole range of measurements. CONCLUSIONS: Results of automated oscillometric ABI determination correlated well with Doppler-assisted measurements and could be obtained in shorter time. Agreement was particularly high in oligo-symptomatic non-diabetic patients.
Resumo:
Regular physical activity (PA) decreases mortality risk in survivors of breast and colorectal cancer. Such impacts of exercise have prompted initiatives designed both to promote and adequately monitor PA in cancer survivors. This study examines the validity of 2 widely used self-report methods for PA determination, the International Physical Activity Questionnaire short version (IPAQ-SF) and Global Physical Activity Questionnaire (GPAQ). Both instruments were compared with the triaxial accelerometry (Actigraph) method as an objective reference standard. Study participants were 204 cancer survivors (both sexes, aged 18-79 years). Compared with accelerometry, both questionnaires significantly overestimated PA levels (across all intensities) and underestimated physical inactivity levels. No differences were detected between the 2 questionnaires except for a shorter inactivity time estimated by GPAQ (p=0.001). The Bland and Altman method confirmed that both questionnaires overestimated all PA levels. Receiver operating characteristic (ROC) analysis classified IPAQ and GPAQ as fair and poor predictors, respectively, of the proportions of survivors fulfilling international PA recommendations (≥150 min·week-1 of moderate-vigorous PA). IPAQ-SF showed a higher sensitivity but lower specificity than GPAQ. Our data do not support the use of IPAQ-SF or GPAQ to determine PA or inactivity levels in cancer survivors.
Resumo:
BACKGROUND: In acute respiratory failure, arterial blood gas analysis (ABG) is used to diagnose hypercapnia. Once non-invasive ventilation (NIV) is initiated, ABG should at least be repeated within 1 h to assess PaCO2 response to treatment in order to help detect NIV failure. The main aim of this study was to assess whether measuring end-tidal CO2 (EtCO2) with a dedicated naso-buccal sensor during NIV could predict PaCO2 variation and/or PaCO2 absolute values. The additional aim was to assess whether active or passive prolonged expiratory maneuvers could improve the agreement between expiratory CO2 and PaCO2. METHODS: This is a prospective study in adult patients suffering from acute hypercapnic respiratory failure (PaCO2 ≥ 45 mmHg) treated with NIV. EtCO2 and expiratory CO2 values during active and passive expiratory maneuvers were measured using a dedicated naso-buccal sensor and compared to concomitant PaCO2 values. The agreement between two consecutive values of EtCO2 (delta EtCO2) and two consecutive values of PaCO2 (delta PaCO2) and between PaCO2 and concomitant expiratory CO2 values was assessed using the Bland and Altman method adjusted for the effects of repeated measurements. RESULTS: Fifty-four datasets from a population of 11 patients (8 COPD and 3 non-COPD patients), were included in the analysis. PaCO2 values ranged from 39 to 80 mmHg, and EtCO2 from 12 to 68 mmHg. In the observed agreement between delta EtCO2 and deltaPaCO2, bias was -0.3 mmHg, and limits of agreement were -17.8 and 17.2 mmHg. In agreement between PaCO2 and EtCO2, bias was 14.7 mmHg, and limits of agreement were -6.6 and 36.1 mmHg. Adding active and passive expiration maneuvers did not improve PaCO2 prediction. CONCLUSIONS: During NIV delivered for acute hypercapnic respiratory failure, measuring EtCO2 using a dedicating naso-buccal sensor was inaccurate to predict both PaCO2 and PaCO2 variations over time. Active and passive expiration maneuvers did not improve PaCO2 prediction. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01489150.
Resumo:
Objective To determine overall, test–retest and inter-rater reliability of posture indices among persons with idiopathic scoliosis. Design A reliability study using two raters and two test sessions. Setting Tertiary care paediatric centre. Participants Seventy participants aged between 10 and 20 years with different types of idiopathic scoliosis (Cobb angle 15 to 60°) were recruited from the scoliosis clinic. Main outcome measures Based on the XY co-ordinates of natural reference points (e.g. eyes) as well as markers placed on several anatomical landmarks, 32 angular and linear posture indices taken from digital photographs in the standing position were calculated from a specially developed software program. Generalisability theory served to estimate the reliability and standard error of measurement (SEM) for the overall, test–retest and inter-rater designs. Bland and Altman's method was also used to document agreement between sessions and raters. Results In the random design, dependability coefficients demonstrated a moderate level of reliability for six posture indices (ϕ = 0.51 to 0.72) and a good level of reliability for 26 posture indices out of 32 (ϕ ≥ 0.79). Error attributable to marker placement was negligible for most indices. Limits of agreement and SEM values were larger for shoulder protraction, trunk list, Q angle, cervical lordosis and scoliosis angles. The most reproducible indices were waist angles and knee valgus and varus. Conclusions Posture can be assessed in a global fashion from photographs in persons with idiopathic scoliosis. Despite the good reliability of marker placement, other studies are needed to minimise measurement errors in order to provide a suitable tool for monitoring change in posture over time.
Resumo:
Objetivo: evaluar la reproducibilidad prueba-reprueba y el nivel de acuerdo entre mediciones de las pruebas 30 seg (30-s) Arm Curl y 30-s Chair Stand en una muestra de adultos mayores de Bucaramanga. Materiales y métodos: se realizó un estudio de evaluación de tecnologías diagnósticas. Ambas pruebas fueron administradas en dos oportunidades por el mismo evaluador a 111 adultos mayores de 59 años (70,4 ± 7,3), con un intervalo de 4 a 8 días. En el análisis se determinó la reproducibilidad prueba-reprueba mediante el coeficiente de correlación intraclase, CCI= 2,1 con sus respectivos intervalos de confianza de 95% (IC 95%). El nivel de acuerdo se estableció mediante el método de Bland y Altman. Resultados: la reproducibilidad prueba-reprueba para el 30-s Arm Curl test fue muy buena, con un CCI= 0,88 y para el 30-s Chair Stand test fue buena,con un CCI= 0,78. Así, el acuerdo fue muy bueno para las dos pruebas de resistencia muscular. Los límites de acuerdo de 95% estuvieron entre -3,8 y 3,2 repeticiones para la prueba 30-s ChairStand y entre -3,1 y 2,8 repeticiones para la prueba 30-s Arm Curl. Conclusión: las pruebas 30-s Arm Curl y 30-s Chair Stand tienen buena reproducibilidad y nivel de acuerdo para evaluar resistencia muscular en adultos mayores funcionalmente independientes.
Resumo:
Background: Dietary assessment methods are important tools for nutrition research. Online dietary assessment tools have the potential to become invaluable methods of assessing dietary intake because, compared with traditional methods, they have many advantages including the automatic storage of input data and the immediate generation of nutritional outputs. Objective: The aim of this study was to develop an online food frequency questionnaire (FFQ) for dietary data collection in the “Food4Me” study and to compare this with the validated European Prospective Investigation of Cancer (EPIC) Norfolk printed FFQ. Methods: The Food4Me FFQ used in this analysis was developed to consist of 157 food items. Standardized color photographs were incorporated in the development of the Food4Me FFQ to facilitate accurate quantification of the portion size of each food item. Participants were recruited in two centers (Dublin, Ireland and Reading, United Kingdom) and each received the online Food4Me FFQ and the printed EPIC-Norfolk FFQ in random order. Participants completed the Food4Me FFQ online and, for most food items, participants were requested to choose their usual serving size among seven possibilities from a range of portion size pictures. The level of agreement between the two methods was evaluated for both nutrient and food group intakes using the Bland and Altman method and classification into quartiles of daily intake. Correlations were calculated for nutrient and food group intakes. Results: A total of 113 participants were recruited with a mean age of 30 (SD 10) years (40.7% male, 46/113; 59.3%, 67/113 female). Cross-classification into exact plus adjacent quartiles ranged from 77% to 97% at the nutrient level and 77% to 99% at the food group level. Agreement at the nutrient level was highest for alcohol (97%) and lowest for percent energy from polyunsaturated fatty acids (77%). Crude unadjusted correlations for nutrients ranged between .43 and .86. Agreement at the food group level was highest for “other fruits” (eg, apples, pears, oranges) and lowest for “cakes, pastries, and buns”. For food groups, correlations ranged between .41 and .90. Conclusions: The results demonstrate that the online Food4Me FFQ has good agreement with the validated printed EPIC-Norfolk FFQ for assessing both nutrient and food group intakes, rendering it a useful tool for ranking individuals based on nutrient and food group intakes.
Resumo:
OBJECTIVE: The aim of this study was to determine the influence of polyvinyl chloride (PVC) wrapping on the performance of two laser fluorescence devices (LF and LFpen) by assessing tooth occlusal surfaces. BACKGROUND DATA: Protection of their tips may influence LF measurements. To date there are no studies evaluating the influence of this protection on the performance of the LFpen on permanent teeth, or comparing it to the original LF device. MATERIALS AND METHODS: One hundred nineteen permanent molars were assessed by two experienced dentists using the LF and the LFpen devices, both with and without PVC wrapping. The teeth were histologically prepared and assessed for caries extension. RESULTS: The LF values with and without PVC wrapping were significantly different. For both LF devices, the sensitivity and accuracy were lower when the PVC wrapping was used. The specificity was statistically significantly higher for the LFpen with PVC. No difference was found between the areas under the ROC curves with and without PVC wrapping. The ICC showed excellent interexaminer agreement. The Bland and Altman method showed a range between the upper and the lower limits of agreement of 63.4 and 57.8 units for the LF device, and 49.4 and 74.2 for the LFpen device, with and without PVC wrapping, respectively. CONCLUSIONS: We found an influence of the PVC wrapping on the performance of the LF and LFpen devices. However, since its influence on detection of occlusal caries lesions is considered for, the use of one PVC layer is suggested to avoid cross-contamination in clinical practice.
Resumo:
Background: CO2 monitoring is recommended for thoracic telescopic procedures and for spontaneous breathing general anesthesia in children. During flexible bronchoscopy (FB) in children, the various currently available methods of CO2 measurements are limited. The CO2 falls and increases have been reported in FB but it is unknown whether airway lesions predispose to CO2 change. The aim of this study was to describe and validate endoscopic intratracheal CO2 measurements in children undergoing FB under spontaneously breathing GA. Methods: Endtidal CO2 (PECO2) measurements at the start (Start-CO2) and end (End-CO2) of FB on 100 consecutive children were performed using a newly designed endoscopic intratracheal method. To validate the method blood gas sampling was simultaneously performed in 28 children and results analyzed using the Bland and Altman method, intraclass correlation and 95% range for repeatability. Results: End-CO2 and CO2-change (End-CO2 minus Start-CO2) were significantly different in children with airway lesions (CO2 change: no lesion = 3 mmHg, extrathoracic airway lesion = 4.5, intrathoracic airway lesion = 8, P = 0.038). There was no significant difference in Start-CO2 values among the groups. CO2-change in those aged > 12 months was similar to those >12 months. Intratracheal CO2 measurements were comparable with arterial blood values in the Bland and Altman plots. The intraclass correlation was 0.69 and 95% range for repeatability was 3.7-4.17 mmHg. Conclusions: Midtracheal PECO2 provides a useful estimate of PaCO2 for monitoring the respiratory status of children undergoing FB. The presence of airway lesions rather than age is associated with significant increased PCO2 rise.
Resumo:
OBJECTIVE: To assess the accuracy of a semiautomated 3D volume reconstruction method for organ volume measurement by postmortem MRI. METHODS: This prospective study was approved by the institutional review board and the infants' parents gave their consent. Postmortem MRI was performed in 16 infants (1 month to 1 year of age) at 1.5 T within 48 h of their sudden death. Virtual organ volumes were estimated using the Myrian software. Real volumes were recorded at autopsy by water displacement. The agreement between virtual and real volumes was quantified following the Bland and Altman's method. RESULTS: There was a good agreement between virtual and real volumes for brain (mean difference: -0.03% (-13.6 to +7.1)), liver (+8.3% (-9.6 to +26.2)) and lungs (+5.5% (-26.6 to +37.6)). For kidneys, spleen and thymus, the MRI/autopsy volume ratio was close to 1 (kidney: 0.87±0.1; spleen: 0.99±0.17; thymus: 0.94±0.25), but with a less good agreement. For heart, the MRI/real volume ratio was 1.29±0.76, possibly due to the presence of residual blood within the heart. The virtual volumes of adrenal glands were significantly underestimated (p=0.04), possibly due to their very small size during the first year of life. The percentage of interobserver and intraobserver variation was lower or equal to 10%, but for thymus (15.9% and 12.6%, respectively) and adrenal glands (69% and 25.9%). CONCLUSIONS: Virtual volumetry may provide significant information concerning the macroscopic features of the main organs and help pathologists in sampling organs that are more likely to yield histological findings.
Resumo:
The use of the flow vs time relationship obtained with the nasal prongs of the AutoSetä (AS) system (diagnosis mode) has been proposed to detect apneas and hypopneas in patients with reasonable nasal patency. Our aim was to compare the accuracy of AS to that of a computerized polysomnographic (PSG) system. The study was conducted on 56 individuals (45 men) with clinical characteristics of obstructive sleep apnea (OSA). Their mean (± SD) age was 44.6 ± 12 years and their body mass index was 31.3 ± 7 kg/m2. Data were submitted to parametric analysis to determine the agreement between methods and the intraclass correlation coefficient was calculated. The Student t-test and Bland and Altman plots were also used. Twelve patients had an apnea-hypopnea index (AHI) <10 in bed and 20 had values >40. The mean (± SD) AHI PSG index of 37.6 (28.8) was significantly lower (P = 0.0003) than AHI AS (41.8 (25.3)), but there was a high intraclass correlation coefficient (0.93), with 0.016 variance. For a threshold of AHI of 20, AS showed 73.0% accuracy, 97% sensitivity and 60% specificity, with positive and negative predictive values of 78% and 93%, respectively. Sensitivity, specificity and negative predictive values increased in parallel to the increase in AHI threshold for detecting OSA. However, when the differences of AHI PSG-AS were plotted against their means, the limits of agreement between the methods (95% of the differences) were +13 and -22, showing the discrepancy between the AHI values obtained with PSG and AS. Finally, cubic regression analysis was used to better predict the result of AHI PSG as a function of the method proposed, i.e., AHI AS. We conclude that, despite these differences, AHI measured by AutoSetä can be useful for the assessment of patients with high pre-test clinical probability of OSA, for whom standard PSG is not possible as an initial step in diagnosis.