526 resultados para Bioscience


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To make full use of research data, the bioscience community needs to adopt technologies and reward mechanisms that support interoperability and promote the growth of an open 'data commoning' culture. Here we describe the prerequisites for data commoning and present an established and growing ecosystem of solutions using the shared 'Investigation-Study-Assay' framework to support that vision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report produced by Iowa Department of Economic Development

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS: We did a randomised, single-blind, non-inferiority trial with minimum exclusion criteria at nine hospitals in Switzerland. We randomly assigned (1:1) patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes undergoing percutaneous coronary intervention to treatment with biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Randomisation was via a central web-based system and stratified by centre and presence of ST segment elevation myocardial infarction. Patients and outcome assessors were masked to treatment allocation, but treating physicians were not. The primary endpoint, target lesion failure, was a composite of cardiac death, target vessel myocardial infarction, and clinically-indicated target lesion revascularisation at 12 months. A margin of 3·5% was defined for non-inferiority of the biodegradable polymer sirolimus-eluting stent compared with the durable polymer everolimus-eluting stent. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT01443104. FINDINGS: Between Feb 24, 2012, and May 22, 2013, we randomly assigned 2119 patients with 3139 lesions to treatment with sirolimus-eluting stents (1063 patients, 1594 lesions) or everolimus-eluting stents (1056 patients, 1545 lesions). 407 (19%) patients presented with ST-segment elevation myocardial infarction. Target lesion failure with biodegradable polymer sirolimus-eluting stents (69 cases; 6·5%) was non-inferior to durable polymer everolimus-eluting stents (70 cases; 6·6%) at 12 months (absolute risk difference -0·14%, upper limit of one-sided 95% CI 1·97%, p for non-inferiority <0·0004). No significant differences were noted in rates of definite stent thrombosis (9 [0·9%] vs 4 [0·4%], rate ratio [RR] 2·26, 95% CI 0·70-7·33, p=0·16). In pre-specified stratified analyses of the primary endpoint, biodegradable polymer sirolimus-eluting stents were associated with improved outcome compared with durable polymer everolimus-eluting stents in the subgroup of patients with ST-segment elevation myocardial infarction (7 [3·3%] vs 17 [8·7%], RR 0·38, 95% CI 0·16-0·91, p=0·024, p for interaction=0·014). INTERPRETATION: In a patient population with minimum exclusion criteria and high adherence to dual antiplatelet therapy, biodegradable polymer sirolimus-eluting stents were non-inferior to durable polymer everolimus-eluting stents for the combined safety and efficacy outcome target lesion failure at 12 months. The noted benefit in the subgroup of patients with ST-segment elevation myocardial infarction needs further study. FUNDING: Clinical Trials Unit, University of Bern, and Biotronik, Bülach, Switzerland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Professional development opportunities are offered piecemeal to K-12 teachers in Iowa through Area Education Agencies (AEAs), Regents’ institutions, community colleges, private colleges, private corporations, and out-of-state institutions (often online). Compiling a comprehensive list of in-service and pre-service opportunities for primary and secondary public school educators is not feasible for a variety of reasons. However, this report briefly summarizes most of the bioscience-related options for professional development available for K-12 educators this summer and over the past year.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Biodegradable polymers for release of antiproliferative drugs from metallic drug-eluting stents aim to improve long-term vascular healing and efficacy. We designed a large scale clinical trial to compare a novel thin strut, cobalt-chromium drug-eluting stent with silicon carbide-coating releasing sirolimus from a biodegradable polymer (O-SES, Orsiro; Biotronik, Bülach, Switzerland) with the durable polymer-based Xience Prime/Xpedition everolimus-eluting stent (EES) (Xience Prime/Xpedition stent, Abbott Vascular, IL) in an all-comers patient population. DESIGN: The multicenter BIOSCIENCE trial (NCT01443104) randomly assigned 2,119 patients to treatment with biodegradable polymer sirolimus-eluting stents (SES) or durable polymer EES at 9 sites in Switzerland. Patients with chronic stable coronary artery disease or acute coronary syndromes, including non-ST-elevation and ST-elevation myocardial infarction, were eligible for the trial if they had at least 1 lesion with a diameter stenosis >50% appropriate for coronary stent implantation. The primary end point target lesion failure (TLF) is a composite of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization within 12 months. Assuming a TLF rate of 8% at 12 months in both treatment arms and accepting 3.5% as a margin for noninferiority, inclusion of 2,060 patients would provide more than 80% power to detect noninferiority of the biodegradable polymer SES compared with the durable polymer EES at a 1-sided type I error of 0.05. Clinical follow-up will be continued through 5 years. CONCLUSION: The BIOSCIENCE trial will determine whether the biodegradable polymer SES is noninferior to the durable polymer EES with respect to TLF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Global environmental changes threaten ecosystems and cause significant alterations to the supply of ecosystem services that are vital for human well-being. We provide an assessment of the potential impacts of climate change on European diversity of vertebrates and their associated pest control services. We modeled the distributions of the species that provide this service using ensembles of forecasts from bioclimatic envelope models and then used their results to generate maps of potential species richness among vertebrate providers of pest control services. We assessed how potential richness of pest control providers would change according to different climate and greenhouse emissions scenarios. We found that potential richness of pest control providers was likely to face substantial reductions, especially in southern European countries that had economies highly dependent on agricultural yields. In much of central and northern Europe, where countries had their economies less dependent on agriculture, climate change was likely to benefit pest control providers

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The 3rd International Conference on High Pressure Bioscience and Biotechnology was held in the city of Rio de Janeiro from September 27 to September 30, 2004. The meeting, promoted by the International Association of High Pressure Bioscience and Biotechnology (IAHPBB), congregated top scientists and researchers from all over the world. In common, they shared the use of hydrostatic pressure for research, technical development, or industrial applications. The meeting consisted of invited lectures, contributed papers and a well-attended poster session. Very exciting discussions were held inside and outside the sessions, and the goals of discussing state-of-the-art data and establishing working collaborations and co-operations were fully attained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Much attention has been given to financial conflicts of interest (COI) in bioscience research. Yet to date, surprisingly little attention has focused on other COIs that arise in supervisor-student relations. We examine a spectrum of related situations, ranging from standard graduate supervision through to dual relationships sometimes found in research with commercial potential. We illustrate some of the less-obvious factors that can bias supervisory judgment, and situate financial COI along a spectrum of forces that are deserving of recognition. We conclude by providing two sets of recommendations: one for individual supervisors, and the other for institutions and policy-makers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This resource consists of freely available images contributed by academics, researchers, Learned Societies, industry and individuals with rights cleared for educational purposes. Users are able to search for images based on keywords or browse within a wide range of bioscience subject areas. Images are then 'downloadable' along with informative descriptive text provided by the contributor. All images undergo a validation process by Centre for Bioscience staff with good subject knowledge. ImageBank also offers reviews of, and links to existing bioscience image databases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the main features of a program written to perform electronic marking of quantitative or simple text questions. One of the main benefits is that it can check answers for being consistent with earlier errors, so can cope with a range of numerical questions. We summarise our experience of using it in a statistics course taught to 200 bioscience students.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bioscience Horizons (BH)commenced publication in 2008 and features research papers and reviews written by graduating UK bioscience students. The journal is run by a consortium of UK universities (the Universities of Nottingham, Reading, Leeds and Chester) in association with Oxford University Press. Its submissions encompass the full range of subjects taught by UK bioscience departments, ranging from agronomy to zoology and including animal behaviour, cancer research, environmental biology, microbial sciences, molecular biology, pharmacolgy, primatology, taxonomy and other areas. BH receives manuscripts from recent graduates (with a bachelor of science or equivalent first degree) describing research carried out during their undergraduate studies, usually as a final-year research project. All submissions undergo expert review and have to meet strict criteria for scientific excellence and originality. Articles are written by a single author and published with the agreement of the graduate's home university department. The journal has an ISSN number and is open-access; articles are freely 'cite-able' contributions to the bioscience research literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fieldwork is an important and often enjoyable part of learning in Bioscience degree courses, however it is unclear how the recent reforms to Higher Education (HE) may impact the future funding of outdoor learning. This paper reports on the findings from a recent survey of 30 HE Bioscience practitioners from across the UK. Their current level of fieldwork provision and factors affecting this provision in the future were explored. The data showed that the level of fieldwork had remained similar over the past five years and this was set to remain so over the next academic year and also into the next five years (when it may even increase). Funding of fieldwork was under review in most institutions due to the increase in student tuition fees and it was found that in some cases the cost of compulsory fieldwork will be subsumed within the overall course fee. Many influencing factors were discussed, but the most frequently raised topics were that of the development of employability skills during fieldwork and its importance in attracting and retaining students. Both topics are high on the agenda of HE institutions going forward into the new funding model, suggesting that fieldwork will remain a central part of the Bioscience curriculum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Biodegradable polymers for release of antiproliferative drugs from metallic drug-eluting stents (DES) aim to improve long-term vascular healing and efficacy. We designed a large scale clinical trial to compare a novel thin strut, cobalt chromium DES with silicon carbide coating releasing sirolimus from a biodegradable polymer (Orsiro, O-SES) with the durable polymer-based Xience Prime everolimus-eluting stent (X-EES) in an all-comers patient population. Design The multicenter BIOSCIENCE trial (NCT01443104) randomly assigned 2,119 patients to treatment with biodegradable polymer SES or durable polymer EES at 9 sites in Switzerland. Patients with chronic stable coronary artery disease or acute coronary syndromes, including non-ST-elevation and ST-elevation myocardial infarction, were eligible for the trial if they had at least one lesion with a diameter stenosis >50% appropriate for coronary stent implantation. The primary endpoint target lesion failure (TLF) is a composite of cardiac death, target-vessel myocardial infarction, and clinically-driven target lesion revascularization within 12 months. Assuming a TLF rate of 8% at 12 months in both treatment arms and accepting 3.5% as a margin for non-inferiority, inclusion of 2,060 patients would provide 80% power to detect non-inferiority of the biodegradable polymer SES compared with the durable polymer EES at a one-sided type I error of 0.05. Clinical follow-up will be continued through five years. Conclusion The BIOSCIENCE trial will determine whether the biodegradable polymer SES is non-inferior to the durable polymer EES with respect to TLF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-blind, non-inferiority trial with minimum exclusion criteria at nine hospitals in Switzerland. We randomly assigned (1:1) patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes undergoing percutaneous coronary intervention to treatment with biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Randomisation was via a central web-based system and stratified by centre and presence of ST segment elevation myocardial infarction. Patients and outcome assessors were masked to treatment allocation, but treating physicians were not. The primary endpoint, target lesion failure, was a composite of cardiac death, target vessel myocardial infarction, and clinically-indicated target lesion revascularisation at 12 months. A margin of 3·5% was defined for non-inferiority of the biodegradable polymer sirolimus-eluting stent compared with the durable polymer everolimus-eluting stent. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT01443104. FINDINGS Between Feb 24, 2012, and May 22, 2013, we randomly assigned 2119 patients with 3139 lesions to treatment with sirolimus-eluting stents (1063 patients, 1594 lesions) or everolimus-eluting stents (1056 patients, 1545 lesions). 407 (19%) patients presented with ST-segment elevation myocardial infarction. Target lesion failure with biodegradable polymer sirolimus-eluting stents (69 cases; 6·5%) was non-inferior to durable polymer everolimus-eluting stents (70 cases; 6·6%) at 12 months (absolute risk difference -0·14%, upper limit of one-sided 95% CI 1·97%, p for non-inferiority <0·0004). No significant differences were noted in rates of definite stent thrombosis (9 [0·9%] vs 4 [0·4%], rate ratio [RR] 2·26, 95% CI 0·70-7·33, p=0·16). In pre-specified stratified analyses of the primary endpoint, biodegradable polymer sirolimus-eluting stents were associated with improved outcome compared with durable polymer everolimus-eluting stents in the subgroup of patients with ST-segment elevation myocardial infarction (7 [3·3%] vs 17 [8·7%], RR 0·38, 95% CI 0·16-0·91, p=0·024, p for interaction=0·014). INTERPRETATION In a patient population with minimum exclusion criteria and high adherence to dual antiplatelet therapy, biodegradable polymer sirolimus-eluting stents were non-inferior to durable polymer everolimus-eluting stents for the combined safety and efficacy outcome target lesion failure at 12 months. The noted benefit in the subgroup of patients with ST-segment elevation myocardial infarction needs further study. FUNDING Clinical Trials Unit, University of Bern, and Biotronik, Bülach, Switzerland.