51 resultados para Bioabsorbable
Resumo:
OBJECTIVES: This study assessed the bone density gain and its relationship with the periodontal clinical parameters in a case series of a regenerative therapy procedure. MATERIAL AND METHODS: Using a split-mouth study design, 10 pairs of infrabony defects from 15 patients were treated with a pool of bovine bone morphogenetic proteins associated with collagen membrane (test sites) or collagen membrane only (control sites). The periodontal healing was clinically and radiographically monitored for six months. Standardized pre-surgical and 6-month postoperative radiographs were digitized for digital subtraction analysis, which showed relative bone density gain in both groups of 0.034 ± 0.423 and 0.105 ± 0.423 in the test and control group, respectively (p>0.05). RESULTS: As regards the area size of bone density change, the influence of the therapy was detected in 2.5 mm² in the test group and 2 mm² in the control group (p>0.05). Additionally, no correlation was observed between the favorable clinical results and the bone density gain measured by digital subtraction radiography (p>0.05). CONCLUSIONS: The findings of this study suggest that the clinical benefit of the regenerative therapy observed did not come with significant bone density gains. Long-term evaluation may lead to a different conclusions.
Resumo:
Aims: Surgical staple line dehiscence usually leads to severe complications. Several techniques and materials have been used to reinforce this stapling and thus reduce the related complications. The objective was to compare safety of two types of anastomotic reinforcement in open gastric bypass. Methods: A prospective, randomized study comparing an extraluminal suture, fibrin glue, and a nonpermanent buttressing material, Seamguard (R), for staple line reinforcement. Fibrin glue was excluded from the study and analysis after two leaks, requiring surgical reintervention, antibiotic therapy, and prolonged patient hospitalization. Results: Twenty patients were assigned to the suture and Seamguard reinforcement groups. The groups were similar in terms of preoperative characteristics. No staple line dehiscence occurred in the two groups, whereas two cases of dehiscence occurred in the fibrin glue group. No mortality occurred and surgical time was statistically similar for both techniques. Seamguard made the surgery more expensive. Conclusion: In our service, staple line reinforcement in open bariatric surgery with oversewing or Seamguard was considered to be safe. Seamguard application was considered to be easier than oversewing, but more expensive.
Resumo:
Chitosan biocompatibility and biodegradability properties make this biopolymer promising for the development of advanced internal fixation devices for orthopedic applications. This work presents a detailed study on the production and characterization of three dimensional (3D) dense, non-porous, chitosan-based structures, with the ability to be processed in different shapes, and also with high strength and stiffness. Such features are crucial for the application of such 3D structures as bioabsorbable implantable devices. The influence of chitosan's molecular weight and the addition of one plasticizer (glycerol) on 3D dense chitosan-based products' biomechanical properties were explored. Several specimens were produced and in vitro studies were performed in order to assess the cytotoxicity of these specimens and their physical behavior throughout the enzymatic degradation experiments. The results point out that glycerol does not impact on cytotoxicity and has a high impact in improving mechanical properties, both elasticity and compressive strength. In addition, human mesenchymal stem/stromal cells (MSC) were used as an ex-vivo model to study cell adhesion and proliferation on these structures, showing promising results with fold increase values in total cell number similar to the ones obtained in standard cell culture flasks. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
The aim of this study was to compare clinical and radiological outcome of lateral condyle fracture of the elbow in children treated with bioabsorbable or metallic material. From January 2008 to December 2009, 16 children with similar fractures and ages were grouped according to the fixation material used. Children were seen at 3, 6, and 12 months and more than 4 years (mean 51.8 months) postoperatively. The clinical results were compared using the Mayo Elbow Performance Score (MEPS). Radiographic studies of the fractured and opposite elbow were assessed at last follow-up control. Twelve children had a sufficient followup and could be included in the study. Seven could be included in the traditional group and 5 in the bioabsorbable group. At 12 months, the MEPS was 100 for every child in both groups. Asymptomatic bony radiolucent visible tracks and heterotopic ossifications were noted in both groups. There were no significant differences in terms of clinical and radiological outcome between the two groups. The use of bioabsorbable pins or screws is a reasonable alternative to the traditional use of metallic materials for the treatment of lateral condyle fracture of the elbow in children.
Resumo:
Les fractures du condyle externe de l'enfant sont un traumatisme relativement fréquent qui survient le plus souvent chez l'enfant entre 5 et 15 ans. Elles sont classées en 3 grades : le grade 1 sans déplacement qui peuvent être traitées conservativement et les grades 2 (déplacées) et 3 (disloquées) qui nécessitent une prise en charge chirurgicale par réduction ouverte et embrochage. Le traitement traditionnel de ces fractures consistent en la mise en place de broches/vis métalliques qui doivent être retirées quelques semaines plus tard lors d'une seconde intervention. Depuis les années 90, des matériaux bio-résorbables à base d'acide polyglycoliques sont apparus en chirurgie orthopédique et traumatologique. En raison de la survenue de complications telles que réactions inflammatoires, formation de séromes ou ostéolyse, l'utilisation du matériel conventionnel a été préférée. Cependant, depuis quelques années, de nouveaux matériaux en acide polylactique sont apparus sur le marché. La période de résorption étant beaucoup plus lente, ces matériaux induisent des réactions beaucoup plus faibles, sans conséquences cliniques relevées jusqu'à présent. Chez l'adulte, de récentes études ont prouvés l'efficacité et l'absence d'effets secondaires liés à ces matériaux. Par contre, chez l'enfant, peu d'études à moyen terme ont été réalisées et l'impact sur l'os en croissance est peu connu, même si pour l'heure aucune conséquence clinique n'a été relevée. Dans le cadre de notre étude, nous avons comparé 2 groupes d'enfants traités pour des fractures du condyle externe du coude. Le premier groupe traité par du matériel conventionnel et le second par matériel résorbable. Les enfants ont tous étés suivis de manière très étroite durant la première année et la récupération clinique est similaire pour les 2 groupes. A 4 ans du traumatisme, les résultats fonctionnels sont identiques pour les 2 groupes et aucune complication liée au matériel résorbable n'a été mise en évidence. Par ailleurs, à 1 et 4 ans, les clichés radiologiques montrent l'absence de lésions liées au matériel résorbable. En conclusion, dans le cadre de notre travail nous avons pu montrer l'efficacité des matériaux résorbables dans la prise en charge des fractures du condyle externe du coude chez l'enfant. Ces matériaux permettent d'optimiser la prise en charge de ce type de fracture en prévenant un risque opératoire et anesthésique liés à une seconde intervention nécessaire au retrait du matériel d'ostéosynthèse conventionnel. Par ailleurs le coût lié à la prise en charge globale de ce type de fracture est moindre lors de l'utilisation de matériel résorbable.
Resumo:
Abstract: Osteomyelitis is responsible for high treatment costs, long hospital stays, and results in substantial morbidity. Treatment with surgical debridement and antibiotic-impregnated Polymethylmetacrylate (PMMA) beads is the standard of care, providing high local but low serum antibiotic concentrations, thereby avoiding systemic toxicity. However, for several reasons, the beads require surgical removal. Alternative antibiotic delivery systems should improve the treatment of bone infection, actively encourage bone healing and require no additional surgery for removal. We investigated the activity of gentamicin-loaded bioabsorbable beads against different microorganisms (Staphylococcus epidermidis, S. aureus, Escherichia coli, Enterococcus faecalis, Candida albicans) commonly causing surgical site bone infection, by microcalorimetry. Calcium sulphate beads containing gentamicin were incubated in microcalorimetry ampoules containing different concentrations of the corresponding microorganism. Growth medium with each germ and unloaded beads was used as positive control, growth medium with loaded beads alone as negative control. Bacterial growth-related heat production at 37 °C was measured for 24 h. Cultures without gentamicin-loaded beads produced heat-flow peaks corresponding to the exponential growth of the corresponding microorganisms in nutrient-rich medium. In contrast, cultures with gentamicin-loaded beads completely suppressed heat production during 24 h, demonstrating their antibiotic activity. Gentamicin-loaded beads effectively inhibited growth of susceptible microorganisms, under the described in vitro conditions.
Resumo:
Grâce à la prophylaxie antibiotique per-opératoire, à l'amélioration des techniques chirurgicales et au flux laminaire dans les blocs opératoires le taux d'infections postopératoires a pu être diminué dans les interventions chirurgicales orthopédiques. Il stagne néanmoins à environ 0,5- 2% dans les fractures fermées ainsi que dans les interventions orthopédiques électives, et peut monter jusqu'à 30% dans les fractures ouvertes stade III. L'ostéomyelite et la pseudarthrose infectée, qui peuvent en découler, sont responsables de séjours hospitaliers prolongés, engendrent des coûts de traitement élevés, et conduisent souvent à une morbidité substantielle. Le traitement de l'ostéomyelite combine le débridement chirurgical et l'administration d'antibiotiques. Cependant l'administration systémique d'antibiotiques à hautes doses est problématique en raison de leur toxicité systémique et de leur faible pénétration dans les tissus ischémiques et nécrotiques, souvent présents dans l'ostéomyelite. Pour ces raisons, le traitement standard actuel consiste, après débridement chirurgical, en la mise en place de billes de Polyrnéthylmétacrylate (PMMA) imprégnées d'antibiotique, qui fournissent des concentrations locales élevées mais systémiques basses. Malheureusement, ces billes doivent être enlevées une fois l'infection guérie, ce qui nécessite une nouvelle intervention chirurgicale. Des systèmes de libération antibiotique alternatifs devraient non seulement guérir l'infection osseuse, mais également encourager activement la consolidation osseuse et ne pas nécessiter de nouvelle chirurgie pour leur ablation. Nous avons investigué l'activité de billes résorbables chargées en gentamicine contre différents microorganismes (Staphylococcus epidermidis, Staphylococcus aureus, Escherichia coli, Enterococcus faecalis, Candida albicans), des germes communément responsables d'infections osseuses, par microcalorimétrie, une méthode novice basée sur la mesure de la chaleur produite par des microorganismes qui se répliquent dans une culture. Des billes composées essentiellement de sulfate de calcium et chargées en gentamicine ont été incubées dans des ampoules microcalorimétriques contenant différentes concentrations du germe correspondant. Les bouillons de culture avec chaque germe et billes non-chargées ont été utilisés comme contrôle positif, le bouillon de culture avec bille chargée mais sans germe comme contrôle négatif. La production de chaleur provenant de la croissance bactérienne à 37°C a été mesurée pendant 24 heures. Les cultures ne contenant pas de billes chargées en gentamicine ont. produit des pics de chaleur équivalents à la croissance exponentielle du microorganisme correspondant en milieu riche. Par contre, les germes susceptibles à la gentamicine incubés avec les billes chargées ont complètement supprimé leur production de chaleur pendant 24 heures, démontrant ainsi l'activité antibiotique des billes chargées en gentamicine contre ces germes. Les billes résorbables chargées en gentamicine inhibent donc de façon effective la croissance des germes susceptibles sous les conditions in vitro décrites. Des études sur animaux sont maintenant nécessaires pour déterminer la cinétique d'élution et l'effet antimicrobien de la gentamicine sous conditions in vivo. Finalement des études cliniques devront démontrer que l'utilisation de ces billes est effectivement une bonne option thérapeutique dans le traitement des infections osseuses.
Resumo:
BACKGROUND: Compromised growth after operation remains a significant problem in the cardiovascular field. Some benefit of absorbable suture materials has been demonstrated for arterial anastomoses. However, for the low-pressure zone, few data are available. METHODS: To assess growth in high- versus low-pressure zones we transected the abdominal aorta (high-pressure zone) as well as the inferior vena cava (low-pressure zone) in 10 young mongrel dogs using for reanastomosis 7-0 nonabsorbable versus absorbable running sutures in random order. RESULTS: All animals survived and were evaluated over 12 months including body weight (gain, 212% +/- 45% for nonabsorbable versus 218% +/- 8% for absorbable; not significant), angiography, and, after elective sacrifice, detailed studies of aorta and vena cava. Systematic complication of angiographic data at 12 months showed at the suture level an area of 13.8 mm2 for nonabsorbable versus 24.3 +/- 14.4 mm2 for absorbable sutures in the high-pressure zone as compared with 12.9 +/- 4.9 mm2 for nonabsorbable versus 25.3 +/- 15.4 mm2 for absorbable sutures in the low-pressure zone. Residual lumen, calculated as a function of the area above and below the suture, accounted for 35% +/- 10% for nonabsorbable versus 92% +/- 12% for absorbable sutures (p < 0.001) in the high-pressure zone as compared with 37% +/- 13% for nonabsorbable versus 75% +/- 15% for absorbable sutures (p < 0.003) in the low-pressure zone (high versus low, not significant). Poststenotic dilatation accounted for 199% +/- 22% for nonabsorbable versus 126% +/- 43% for absorbable sutures (p < 0.01) in the high-pressure zone. In the low-pressure zone, poststenotic dilatation remained below the inflow area, and the residual poststenotic lumen accounted for 52% +/- 14% for nonabsorbable versus 77% +/- 16% for absorbable sutures (p < 0.004). Macroscopic, light, and scanning electron microscopic studies confirmed different growth patterns in high- versus low-pressure zones. CONCLUSIONS: Aortic narrowing resulted in poststenotic dilatation and unrestricted outflow path (hourglass-type stenosis). Caval narrowing was followed by restriction of poststenotic outflow path (funnel-type stenosis). Absorbable suture material allows for superior growth in both high- and low-pressure zones.
Resumo:
Vero cells, a cell line established from the kidney of the African green monkey (Cercopithecus aethiops), were cultured in F-10 Ham medium supplemented with 10% fetal calf serum at 37°C on membranes of poly(L-lactic acid) (PLLA), poly(hydroxybutyrate-co-hydroxyvalerate) (PHBV) and their blends in different proportions (100/0, 60/40, 50/50, 40/60, and 0/100). The present study evaluated morphology of cells grown on different polymeric substrates after 24 h of culture by scanning electron microscopy. Cell adhesion was also analyzed after 2 h of inoculation. For cell growth evaluation, the cells were maintained in culture for 48, 120, 240, and 360 h. For cytochemical study, the cells were cultured for 120 or 240 h, fixed, processed for histological analysis, and stained with Toluidine blue, pH 4.0, and Xylidine ponceau, pH 2.5. Our results showed that cell adhesion was better when 60/40 and 50/50 blends were used although cells were able to grow and proliferate on all blends tested. When using PLLA/PHBV (50/50) slightly flattened cells were observed on porous and smooth areas. PLLA/PHBV (40/60) blends presented flattened cells on smooth areas. PLLA/PHBV (0/100), which presented no pores, also supported spreading cells interconnected by thin filaments. Histological sections showed that cells grew as a confluent monolayer on different substrates. Cytochemical analysis showed basophilic cells, indicating a large amount of RNA and proteins. Hence, we detected changes in cell morphology induced by alterations in blend proportions. This suggests that the cells changed their differentiation pattern when on various PLLA/PHBV blend surfaces.
Resumo:
A retrospective study was performed on the use of bioabsorbable pins in the fixation of osteochondral fractures (OCFs) after traumatic patellar dislocation in children. Eighteen children (13 females, 5 males) aged 11 to 15 years (mean age 13.1 years) with osteochondral fracture (OCF) of the knee joint were treated at the authors' institution. Followup ranged from 22 months to 5 years. Diagnosis was verified by X-ray and magnetic resonance imaging (MRI) of the knee and patella. In seven patients the osteochondral fragment was detached from the patella and in 11 it was detached from the lateral femoral condyle. All patients were subjected to open reduction and fixation of the lesion with bioabsorbable pins. Postoperatively, the knee was immobilized in a cast and all patients were mobilized applying a standardized protocol. Bone consolidation was successful in 17 of the 18 patients. Bioabsorbable pins reliably fix OCF in children and adolescents, demonstrating a high incidence of consolidation of the detached osteochondral fragment in short- and middle-term followup without requiring further operative procedures.
Resumo:
BACKGROUND: This study compared bone regeneration following guided bone regeneration with two bioabsorbable collagen membranes in saddle-type bone defects in dog mandibles. METHODS: Three standardized defects were created, filled with bone chips and deproteinized bovine bone mineral (DBBM), and covered by three different methods: control = no membrane; test 1 = collagen membrane; and test 2 = cross-linked collagen membrane (CCM). Each side of the mandible was allocated to one of two healing periods (8 or 16 weeks). The histomorphometric analysis assessed the percentage of bone, soft tissue, and DBBM in the regenerate; the absolute area in square millimeters of the bone regenerate; and the distance in millimeters from the bottom of the defect to the highest point of the regenerate. RESULTS: In the 8-week healing group, two dehiscences occurred with CCM. After 8 weeks, all treatment modalities showed no significant differences in the percentage of bone regenerate. After 16 weeks, the percentage of bone had increased for all treatment modalities without significant differences. For all groups, the defect fill height increased between weeks 8 and 16. The CCM group showed a statistically significant (P = 0.0202) increase over time and the highest value of all treatment modalities after 16 weeks of healing, CONCLUSIONS: The CCM showed a limited beneficial effect on bone regeneration in membrane-protected defects in dog mandibles when healing was uneventful. The observed premature membrane exposures resulted in severely compromised amounts of bone regenerate. This increased complication rate with CCM requires a more detailed preclinical and clinical examination before any clinical recommendations can be made.
Resumo:
BACKGROUND: Coronary stents improve immediate and late results of balloon angioplasty by tacking up dissections and preventing wall recoil. These goals are achieved within weeks after angioplasty, but with current technology stents permanently remain in the artery, with many limitations including the need for long-term antiplatelet treatment to avoid thrombosis. We report a prospective multicentre clinical trial of coronary implantations of absorbable magnesium stents. METHODS: We enrolled 63 patients (44 men; mean age 61.3 [SD 9.5 years]) in eight centres with single de novo lesions in a native coronary artery in a multicentre, non-randomised prospective study. Follow-up included coronary angiography and intravascular ultrasound at 4 months and clinical assessment at 6 months and 12 months. The primary endpoint was cardiac death, non-fatal myocardial infarction, or clinically driven target lesion revascularisation at 4 months FINDINGS: 71 stents, 10-15 mm in length and 3.0-3.5 mm in diameter, were successfully implanted after pre-dilatation in 63 patients. Diameter stenosis was reduced from 61.5 (SD 13.1%) to 12.6 (5.6%) with an acute gain of 1.41 mm (0.46 mm) and in-stent late loss of 1.08 mm (0.49 mm). The ischaemia-driven target lesion revascularisation rate was 23.8% after 4 months, and the overall target lesion revascularisation rate was 45% after 1 year. No myocardial infarction, subacute or late thrombosis, or death occurred. Angiography at 4 months showed an increased diameter stenosis of 48.4 (17.0%). After serial intravascular ultrasound examinations, only small remnants of the original struts were visible, well embedded into the intima. Neointimal growth and negative remodelling were the main operating mechanisms of restenosis. INTERPRETATION: This study shows that biodegradable magnesium stents can achieve an immediate angiographic result similar to the result of other metal stents and can be safely degraded after 4 months. Modifications of stent characteristics with prolonged degradation and drug elution are currently in development.
Resumo:
AIM: In 2001 a prototype of a gun to apply bioabsorbable tacks in cranio-facial surgery has been developed. METHODS: From May 2001 to May 2002 this device has been used in the University Hospital of Innsbruck (Austria) for different cranioplasty procedures, in 34 children, showing its reliability for cranio-facial bone fixation. The children were affected by isolated craniosynostosis or by syndromical synostosis (Apert, Crouzon) and in a case of benign tumor of the parietal skull vault. The range of age, at the time of surgery, was between 3 months and 204 months of age. Bone segments were fixed using self-reinforced polylactide plates and tacks. RESULTS: Firm fixation was obtained intra-operatively and the operative time was reduced about 25-30 minutes as compared to use of plates and screws. This device has just one limitation in its own spring force: sometimes the bone thinner than 1 mm has been broken applying the tacks. CONCLUSION: After the first-year's experience it is possible to confirm that this device reduces, in selected cases, operative time, blood loss, risk of infection and, as a result, the costs.
Resumo:
OBJECTIVES: This study aimed to evaluate the degradation rate and long-term vascular responses to the absorbable metal stent (AMS). BACKGROUND: The AMS demonstrated feasibility and safety at 4 months in human coronary arteries. METHODS: The PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting) was a prospective, multicenter clinical trial of 63 patients with coronary artery disease who underwent AMS implantation. Angiography and intravascular ultrasound (IVUS) were conducted immediately after AMS deployment and at 4 months. Eight patients who did not require repeat revascularization at 4 months underwent late angiographic and IVUS follow-up from 12 to 28 months. RESULTS: The AMS was well-expanded upon deployment without immediate recoil. The major contributors for restenosis as detected by IVUS at 4 months were: decrease of external elastic membrane volume (42%), extra-stent neointima (13%), and intra-stent neointima (45%). From 4 months to late follow-up, paired IVUS analysis demonstrated complete stent degradation with durability of the 4-month IVUS indexes. The neointima was reduced by 3.6 +/- 5.2 mm(3), with an increase in the stent cross sectional area of 0.5 +/- 1.0 mm(2) (p = NS). The median in-stent minimal lumen diameter was increased from 1.87 to 2.17 mm at long-term follow-up. The median angiographic late loss was reduced from 0.62 to 0.40 mm by quantitative coronary angiography from 4 months to late follow-up. CONCLUSIONS: Intravascular ultrasound imaging supports the safety profile of AMS with degradation at 4 months and maintains durability of the results without any early or late adverse findings. Slower degradation is warranted to provide sufficient radial force to improve long-term patency rates of the AMS.