956 resultados para Bearing currents
Resumo:
Induction motors are widely used in industry, and they are generally considered very reliable. They often have a critical role in industrial processes, and their failure can lead to significant losses as a result of shutdown times. Typical failures of induction motors can be classified into stator, rotor, and bearing failures. One of the reasons for a bearing damage and eventually a bearing failure is bearing currents. Bearing currents in induction motors can be divided into two main categories; classical bearing currents and inverter-induced bearing currents. A bearing damage caused by bearing currents results, for instance, from electrical discharges that take place through the lubricant film between the raceways of the inner and the outer ring and the rolling elements of a bearing. This phenomenon can be considered similar to the one of electrical discharge machining, where material is removed by a series of rapidly recurring electrical arcing discharges between an electrode and a workpiece. This thesis concentrates on bearing currents with a special reference to bearing current detection in induction motors. A bearing current detection method based on radio frequency impulse reception and detection is studied. The thesis describes how a motor can work as a “spark gap” transmitter and discusses a discharge in a bearing as a source of radio frequency impulse. It is shown that a discharge, occurring due to bearing currents, can be detected at a distance of several meters from the motor. The issues of interference, detection, and location techniques are discussed. The applicability of the method is shown with a series of measurements with a specially constructed test motor and an unmodified frequency-converter-driven motor. The radio frequency method studied provides a nonintrusive method to detect harmful bearing currents in the drive system. If bearing current mitigation techniques are applied, their effectiveness can be immediately verified with the proposed method. The method also gives a tool to estimate the harmfulness of the bearing currents by making it possible to detect and locate individual discharges inside the bearings of electric motors.
Resumo:
The most common reason for a low-voltage induction motor breakdown is a bearing failure. Along with the increasing popularity of modern frequency converters, bearing failures have become the most important motor fault type. Conditions in which bearing currents are likely to occur are generated as a side effect of fast du/dt switching transients. Once present, different types of bearing currents can accelerate the mechanical wear of bearings by causing deformation of metal parts in the bearing and degradation of the lubricating oil properties.The bearing current phenomena are well known, and several bearing current measurement and mitigation methods have been proposed. Nevertheless, in order to develop more feasible methods to measure and mitigate bearing currents, better knowledge of the phenomena is required. When mechanical wear is caused by bearing currents, the resulting aging impact has to be monitored and dealt with. Moreover, because of the stepwise aging mechanism, periodically executed condition monitoring measurements have been found ineffective. Thus, there is a need for feasible bearing current measurement methods that can be applied in parallel with the normal operation of series production drive systems. In order to reach the objectives of feasibility and applicability, nonintrusive measurement methods are preferred. In this doctoral dissertation, the characteristics and conditions of bearings that are related to the occurrence of different kinds of bearing currents are studied. Further, the study introduces some nonintrusive radio-frequency-signal-based approaches to detect and measure parameters that are associated with the accelerated bearing wear caused by bearing currents.
Resumo:
The work aims to analyze the possibilities of utilizing old crane driving AC induction motors in modern pulse-width-modulated variable frequency drives. Bearing currents and voltage stresses are the two main problems associated with modern IGBT inverters, and they may cause premature failure of an old induction motor. The origins of these two problems are studied. An analysis of the mechanism of bearing failure is proposed. Certain types of bearing currents are considered in detail. The most effective and economical means are chosen for bearing currents mitigation. Transient phenomena of cables and mechanism of over voltages occurring at motor terminals are studied in the work. The weakest places of the stator winding insulation system are shown and recommendations are given considering the mitigation of voltage stresses. Only the most appropriate and cost effective preventative methods are chosen for old motor drives. Rewinding of old motors is also considered.
Resumo:
Power electronic converter drives use, for the sake of high efficiency, pulse-width modulation that results in sequences of high-voltage high-frequency steep-edged pulses. Such a signal contains a set of high harmonics not required for control purposes. Harmonics cause reflections in the cable between the motor and the inverter leading to faster winding insulation ageing. Bearing failures and problems with electromagnetic compatibility may also result. Electrical du/dt filters provide an effective solution to problems caused by pulse-width modulation, thereby increasing the performance and service life of the electrical machines. It is shown that RLC filters effectively decrease the reflection phenomena in the cable. Improved (simple, but effective) solutions are found for both differential- and common-mode signals; these solutions use a galvanic connection between the RLC filter star point and the converter DC link. Foil chokes and film capacitors are among the most widely used components in high-power applications. In actual applications they can be placed in different parts of the cabinet. This fact complicates the arrangement of the cabinet and decreases the reliability of the system. In addition, the inductances of connection wires may prevent filtration at high frequencies. This thesis introduces a new hybrid LC filter that uses a natural capacitance between the turns of the foil choke based on integration of an auxiliary layer into it. The main idea of the hybrid LC filter results from the fact that both the foil choke and the film capacitors have the same roll structure. Moreover, the capacitance between the turns (“intra capacitance”) of the foil inductors is the reason for the deterioration of their properties at high frequencies. It is shown that the proposed filter has a natural cancellation of the intra capacitance. A hybrid LC filter may contain two or more foil layers isolated from each other and coiled on a core. The core material can be iron or even air as in the filter considered in this work. One of the foils, called the main foil, can be placed between the inverter and the motor cable. Other ones, called auxiliary foils, may be connected in star to create differential-mode noise paths, and then coupled to the DC link midpoint to guarantee a traveling path, especially for the common-mode currents. This way, there is a remarkable capacitance between the main foil and the auxiliary foil. Investigations showed that such a system can be described by a simple equivalent LC filter in a wide range of frequencies. Because of its simple hybrid construction, the proposed LC filter can be a cost-effective and competitive solution for modern power drives. In the thesis, the application field of the proposed filter is considered and determined. The basics of hybrid LC filter design are developed further. High-frequency behaviour of the proposed filter is analysed by simulations. Finally, the thesis presents experimental data proving that the hybrid LC filter can be used for du/dt of PWM pulses and reduction of common-mode currents.
Resumo:
FPGA- piirit ovat viime vuosina kehittyneet tehokkaammiksi, mutta samalla niiden hinta on laskenut tasolle, jolloin ne ovat vaihtoehto yhä useampiin sovelluksiin. Kandidaatintyöni aiheena oli suunnitella ja mahdollisesti toteuttaa sulautettu laite, joka laskisi signaalissa esiintyvien pulssien lukumäärää. Sitä käytettäisiin mitattaessa kipinöintiä sähkömoottorin laakeroinnissa. Kipinät havaitaan moottorin ulkopuolelta UHF- antennilla. Antennisignaalista poimittavat pulssit ovat hyvin nopeita, joten digitaaliselta logiikalta vaaditaan myös erityistä nopeutta. Tämän takia laitetta lähdettiin toteuttamaan esimerkiksi mikrokontrollerin sijasta FPGA- piirin avulla. Pulssilaskurin toteutus onnistui suhteellisen vaivattomasti FPGAlla, ja sen toimivuutta käytännössä päästiin testaamaan todellisissa olosuhteissa.
Resumo:
Multilevel converters provide an attractive solution to bring the benefits of speed-controlled rotational movement to high-power applications. Therefore, multilevel inverters have attracted wide interest in both the academic community and in the industry for the past two decades. In this doctoral thesis, modulation methods suitable especially for series connected H-bridge multilevel inverters are discussed. A concept of duty cycle modulation is presented and its modification is proposed. These methods are compared with other well-known modulation schemes, such as space-vector pulse width modulation and carrier-based modulation schemes. The advantage of the modified duty-cycle modulation is its algorithmic simplicity. A similar mathematical formulation for the original duty cycle modulation is proposed. The modified duty cycle modulation is shown to produce well-formed phase-to-neutral voltages that have lower total harmonic distortion than the space-vector pulse width modulation and the duty cycle modulation. The space-vector-based solution and the duty cycle modulation, on the other hand, result in a better-quality line-to-line voltage and current waveform. The voltage of the DC links in the modules of the series-connected H-bridge inverter are shown to fluctuate while they are under load. The fluctuation causes inaccuracies in the voltage production, which may result in a failure of the flux estimator in the controller. An extension for upper-level modulation schemes, which changes the switching instants of the inverter so that the output voltage meets the reference voltage accurately regardless of the DC link voltages, is proposed. The method is shown to reduce the error to a very low level when a sufficient switching frequency is used. An appropriate way to organize the switching instants of the multilevel inverter is to make only one-level steps at a time. This causes restrictions on the dynamical features of the modulation schemes. The produced voltage vector cannot be rotated several tens of degrees in a single switching period without violating the above-mentioned one-level-step rule. The dynamical capabilities of multilevel inverters are analyzed in this doctoral thesis, and it is shown that the multilevel inverters are capable of operating even in dynamically demanding metal industry applications. In addition to the discussion on modulation schemes, an overvoltage in multilevel converter drives caused by cable reflection is addressed. The voltage reflection phenomenon in drives with long feeder cables causes premature insulation deterioration and also affects the commonmode voltage, which is one of the main reasons for bearing currents. Bearing currents, on the other hand, cause fluting in the bearings, which results in premature bearing failure. The reflection phenomenon is traditionally prevented by filtering, but in this thesis, a modulationbased filterless method to mitigate the overvoltage in multilevel drives is proposed. Moreover, the mitigation method can be implemented as an extension for upper-level modulation schemes. The method exploits the oscillations caused by two consecutive voltage edges so that the sum of the oscillations results in a mitigated peak of the overvoltage. The applicability of the method is verified by simulations together with experiments with a full-scale prototype.
Resumo:
Diplomityössä on esitelty ja tutkittu laakerivirtailmiötä sähkökoneissa. Työn pääpaino on suurissa kestomagneettitahtikoneissa, joissa niin sanotut kiertävät laakerivirrat ovat dominoivia. Työssä on lisäksi tarkasteltu staattorin segmentoinnin aiheuttamia matalataajuisia kiertovirtoja. Laakerivirran ja akselijännitteen ehkäisyyn on esitetty sekä testattu mahdollisia ratkaisuja.
Resumo:
Tämä kandityön aihe liittyy LUT Energialla lukuvuonna 2012 – 2013 käynnissä olevaan tutkimukseen, jossa tutkitaan sähkömoottorin laakerivirtojen syntyä. Tätä tutkimusta varten tarvittiin sähkömoottorin etäohjausjärjestelmä, jonka avulla tutkimuksessa käytettävän sähkömoottorin käyttäytymistä voitaisiin tutkia erilaisien käyttöprofiileiden funktiona. Tässä kandityössä suunnitellaan ja toteutetaan edellä kuvattu järjestelmä. Toteutuksessa hyödynnetään nykyaikaista automaatiotekniikkaa, joka yhdessä Ethernet-lähiverkkotekniikan kanssa mahdollistaa etäohjauksen. Valmiin etäohjausjärjestelmän avulla käyttäjä pystyy sekä käynnistämään että sammuttamaan sähkömoottorin, ja määrittämään käyttöprofiilin ON- ja OFF-tilojen ajalliset kestot sekä käyntinopeudet.
Resumo:
A proposta deste trabalho é apresentar uma nova metodologia para determinação experimental das capacitancias parasitas do motor de indução trifásico de rotor em gaiola. As capacitancias parasitas fazem parte do circuito equivalente do motor para estudos de interferência eletromagnética causada no motor de indução em modo comum quando ele for acionado por inversor controlado por modulação por largura de pulsos (MLP). Os procedimentos propostos para o desenvolvimento deste novo método consistem em: a) determinação dos parâmetros do circuito equivalente do motor de indução trifásico, em regime permanente, através de ensaio em laboratório; b) estabelecer configurações de ligações entre o inversor MLP e o motor para medições das grandezas de interesse que são as seguintes: tensões de modo comum e de eixo, correntes de fuga e de eixo, através de circuito de medição desenvolvido para este fim; c) calcular os valores das capacitancias parasitas entre estator e carcaça do motor; estator e rotor; rotor e carcaça e de rolamento utilizando a expressão matemática da definição de capacitancia; d) utilizar o software Pspice para simular o sistema motor de indução trifásico, alimentado por inversor MLP, com os circuitos equivalentes em baixas e altas frequências; e) obter as formas de onda características do fenômeno de modo comum.
Resumo:
Active magnetic bearing is a type of bearing which uses magnetic field to levitate the rotor. These bearings require continuous control of the currents in electromagnets and data from position of the rotor and the measured current from electromagnets. Because of this different identification methods can be implemented with no additional hardware. In this thesis the focus was to implement and test identification methods for active magnetic bearing system and to update the rotor model. Magnetic center calibration is a method used to locate the magnetic center of the rotor. Rotor model identification is an identification method used to identify the rotor model. Rotor model update is a method used to update the rotor model based on identification data. These methods were implemented and tested with a real machine where rotor was levitated with active magnetic bearings and the functionality of the methods was ensured. Methods were developed with further extension in mind and also with the possibility to apply them for different machines with ease.
Resumo:
Evidence for the Chesapeake Bay Crater as the source for New Jersey continental margin ejecta is provided by fine-grained tektites and coarse-grained unmelted ejecta. The Upper Eocene ejecta deposit, now demonstrated to be part of the North American strewn field, occurs on the New Jersey continental margin at Ocean Drilling Program (ODP) Sites 904 and 903. The mineralogy, major oxide composition of the ejecta materials, and biostratigraphic age of the enclosing sediments link the origin of these ejecta to the recently recognized Chesapeake Bay impact crater, located only 330 km away. Sediments associated with the ejecta provide information about the dynamics of impact events. The 35-cm-thick ejecta-bearing layer can be subdivided into three subunits that indicate a sequence of events. Bottom subunit III documents sediment failure and deposition of gravel-sized fragments, middle subunit II records deposition of abundant sand-sized ejecta by gravity settling, and upper subunit I contains a 12-cm-thick sedimentary deposit containing rare silt-sized tektites and evidence of waning currents. These events are interpreted by linking sediment deposition to seismic ground motion and subsequent tsunami waves triggered by both the Chesapeake Bay impact and slope failures.
Resumo:
Cystic fibrosis (CF), a disorder of electrolyte transport manifest in the lungs, pancreas, sweat duct, and vas deferens, is caused by mutations in the CF transmembrane conductance regulator (CFTR). The CFTR protein has been shown to function as a cAMP-activated chloride channel and also regulates a separate protein, the outwardly rectifying chloride channel (ORCC). To determine the consequence of disease-producing mutations upon these functions, mutant CFTR was transiently expressed in Xenopus oocytes and in human airway epithelial cells lacking functional CFTR. Both G551D, a mutation that causes severe lung disease, and A455E, a mutation associated with mild lung disease, altered but did not abolish CFTR's function as a chloride channel in Xenopus oocytes. Airway epithelial cells transfected with CFTR bearing either A455E or G551D had levels of chloride conductance significantly greater than those of mock-transfected and lower than those of wild-type CFTR-transfected cells, as measured by chloride efflux. A combination of channel blockers and analysis of current-voltage relationships were used to dissect the contribution of CFTR and the ORCC to whole cell currents of transfected cells. While CFTR bearing either mutation could function as a chloride channel, only CFTR bearing A455E retained the function of regulating the ORCC. These results indicate that CF mutations can affect CFTR functions differently and suggest that severity of pulmonary disease may be more closely associated with the regulatory rather than chloride channel function of CFTR.
Resumo:
"Schedule of some British patents bearing on polyphase and alternating-current motors," p. 483-488.
Resumo:
An unfavorable denture-bearing area could compromise denture retention and stability, limit mastication, and possibly alter masticatory motion. The purpose of this study was to evaluate the masticatory movements of denture wearers with normal and resorbed denture-bearing areas. Completely edentulous participants who received new complete dentures were selected and divided into 2 groups (n=15) according to the condition of their denture-bearing areas as classified by the Kapur method: a normal group (control) (mean age, 65.9 ± 7.8 years) and a resorbed group (mean age, 70.2 ± 7.6 years). Masticatory motion was recorded and analyzed with a kinesiographic device. The patients masticated peanuts and Optocal. The masticatory movements evaluated were the durations of opening, closing, and occlusion; duration of the masticatory cycle; maximum velocities and angles of opening and closing; total masticatory area; and amplitudes of the masticatory cycle. The data were analyzed by 2-way ANOVA and the Tukey honestly significant difference post hoc test (α=.05). The group with a resorbed denture-bearing area had a smaller total masticatory area in the frontal plane and shorter horizontal masticatory amplitude than the group with normal denture-bearing area (P<.05). Denture wearers with resorbed denture-bearing areas showed reduced jaw motion during mastication.
Resumo:
The structure of probability currents is studied for the dynamical network after consecutive contraction on two-state, nonequilibrium lattice systems. This procedure allows us to investigate the transition rates between configurations on small clusters and highlights some relevant effects of lattice symmetries on the elementary transitions that are responsible for entropy production. A method is suggested to estimate the entropy production for different levels of approximations (cluster sizes) as demonstrated in the two-dimensional contact process with mutation.